Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 2628 KUCHA CHALAN DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | L1 | Accepted-AOC Selected | |
| 2 | L2₹6.5 L+₹48,509 (8.04%)Rejected-AOC | L2 | Rejected-AOC Selected | |
| 3 | L3₹7.3 L+₹1.2 L (20.5%)Rejected-AOC | L3 | Rejected-AOC Selected | |
| 4 | L4₹7.5 L+₹1.5 L (25.1%)Rejected-AOC 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | L4 | Rejected-AOC Selected | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹8.4 L
EMD Value
₹16,770
Closing Date
7 Feb 2019, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
Pdg. ,Fixing ceiling cassette air conditioner visiting area 2IIND floor replacement outlived/not working STAC installed in Room no.101,102,105,PCA Branch, room No.207 Member P/T, room no. 209 at public grievances commission, M-Block, Vikas Bhawan, ND
2019_PWD_167197_1
260/EE (E)/PWD DHC and ND/Central /2018-19
Open Tender
Electrical Works
Works
30 days
New Delhi.
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹16,770
23 Oct 2020
31 Jan 2019
7 Feb 2019
31 Jan 2019
7 Feb 2019
31 Jan 2019
Amount
Supplying, Installation, Testing & Commissioning of energy efficient cassette type Air Conditioner unit of minimum 2 TR capacity, 6000 k cal/hour complete with outdoor condensing unit & ceiling mounted evaporating unit having cordless remote control with angle iron rod, clamp & fresher type hook for supporting of indoor unit, capable of cooling, filtering & dehumidifying suitable for operation on 230Volts, single phase, AC supply complete with copper refrigeration pipe up to 4 meters length and suitable length of drain pipe with outdoor unit stand etc. as required.
Supplying, installation, testing & commissioning of energy efficient following capacity Split type Air Conditioner unit suitable for operation on 230 Volts, 50Hz, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection with upto 4 meters length refrigerant copper pipe heavy gauge 2"/8" / 3"/8" & 5/8" covered with minimum 10mm thickness insulation including 3 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe and also providing 25mm diameter PVC drain connection including accessories, fixing on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site etc as required. a) 2 TR Capacity
b) 1.5 TR Capacity
Supplying and fixing of Digital display wall mounting type Servo Voltage Stabilizer of following capacity for 2 TR capacity Air-Conditioner unit complete etc as required. (Input 145-280 volts) (Output 195-245 volts) (a) 5 KVA
Providing and fixing of M.S. outdoor, floor/ wall mounting powder coated stand suitable for 2 TR capacity split type Air Conditioner outdoor unit complete etc as required.
Supplying and fixing of 20 Ampers, 240 Volts, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 Ampers "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing & Laying of refrigerant copper piping of size 5/8” & 1/4” diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc as required. (Measurement to be done for quantity after 4 meters, which is included in item no -1and2 a & b)
Supplying and fixing of 3 core, 2.5 sq.mm PVC round sheathed multicore flexible copper conductor cable on surface including connection, testing etc. as required.
Providing & fixing of PVC drain pipe of size 25 mm diameter medium gauge drain pipe with necessary accessories such as Nipple, Reducer, clamp on surface / recess including cutting the wall and making good the same complete etc as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Classic Refrigeration Works
Om Shanti Construction
Shaka Electrical (India)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .