BALAKRISHNAN E P
Executive Engineer Minor Irrigation Division B1 Block Civil Station Malappuram 676505
Flood 2019 Electrical restoration works of DG set and Electrical installations due to the flood damages during August 2019 at Pookottumanna RCB RETENDER 2
2021_Irrig_420366_3
EEMI/ET/48/2020-21
Open Tender
Electrical Works
Item Rate
120 days
POOKOTTUMANNA
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,785
Yes
₹20,735
Yes
16 Nov 2021
20 Apr 2021
30 Apr 2021
20 Apr 2021
27 Apr 2021
20 Apr 2021
Amount
1 63 KVA DG SERVICE
Supply and Changing KOEL CARE Premium genuine oil 13 litres CAN
Charges for canopy repairing
Service charges for Diesel Tank
Charges for charging alternator(Repair)
Charges for starter motor repair
Charges for Dismantling/Refitting/Fixing Main alternator
Service charges for Nozzle
charges for FIP service and calibration
service charges for cylinder head
service charges for TURBO CHARGER
Charges for TOP Overhauling
Charges for repairing of main alternator
Charges for loading and unloading
Supply and Changing DIODE SET
Supply and Changing MAIN ALTERNATOR BEARING
Supply and Changing NO Element
Supply and Changing AVR
Supply and Changing ON OFF Switch
Supply and changing suitable MCCB 100A 4 Pole
Supplying and fixing 6 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load
Supply and Changing LLOP Switch
Supply and Changing Interface card 12 V
Supply and Changing KG934 Controller
Supply and Changing K SEALENT(80Ml)
Supply and Changing JOINT BET WATER PUMP
Supply and Changing JOINT FOR ROCKER COVER
Supply and Changing JOINT (OIL SUMP)
Supply and Changing CYLINDER HEAD GASKET(MLS)
Supply and Changing VALVE GUIDE(SEMI FINISH)
Supply and Changing VALVE SEAT INSERT(EXHAUST) SEMI FINISH
Supply and Changing VALVE SEAT INSERT(INLET) SEMI FINISH
Supply and Changing JOINT FOR LUB. OIL HEADER
Supply and Changing INLET AND EXHAUST VALVE PAIR
Supply and Changing VALVE SEAL
Supply and Changing BEARING BIG END 4R 810 STD
Supply and Changing SET OF RINGS
Supply and Changing SET OF WASHERS
Supply and Changing SET OF JOINTS
Supply and Changing JOINT FOR LUB OIL COOLER
Supply and Changing GASKET( FOR EXHAUST MANIFOLD)
Supply and Changing JOINT( FOR INLET MANIFOLD)
Supply and Changing PISTON RING SET
Supply and Changing LUB COIL COOLER (8 PLATES )
Supply and Changing POLY V BELT
Supply and Changing PRIMARY ELEMENT FOR 6M3 AIR CLEANER(2990217219)
Supply and Changing KOEL CARE GENUINE COOLANT PREMIX 10 LITRE CAN
Supply and Changing SECONDARY ELEMENT
Supply and Changing PRIMARY ELEMENT
Supply and Changing SPIN ON FILTER FOR LUBRICATING OIL
Supply and Changing suitable Emergency push button
Supply and Changing Battery 150Ah/12V
Engaging skilled labours for cleaning and clearing vegetations , mud deposit inside the generator and other electrical equipments etc as per the direction of dept officers at site.
Supplying diesel for the testing and trial run of Generator at site for including all cost and conveyance etc complete
2 Restoration of Electrical installations
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly.The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beedingsuitable for 1.60/ 2.00 mm sheet
Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber,suitable size nut & bolt, providng heat shrink sleeves etc. as required.
Supply and providing copper earth bus in the panel board
Supply, conveyance and fixing the following types & current rated control gears & switchgearsconforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.16A -100A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessorbased release with overload setting of 50 - 100% having adjustable OL & SC
Supply, conveyance and fixing the following types & current rated control gears & switchgearsconforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor basedrelease with overload setting of 50 - 100% having adjustable OL & SC
Supply, conveyance and fixing the following types & current rated control gears & switchgearsconforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor basedrelease with overload setting of 50 - 100% having adjustable OL & SC
MCCB AccessoriesSupply and fixing kastel interlock kit up to 250A.
MCCB AccessoriesSupply and fixing one number earth fault Relay up to 125A to 200A with CBCT.
MCCB AccessoriesSupply and fixing auxiliary switch (1 NO + 1 NC) in the existing MCCB of rating up to 630 A.
MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630A MCCB.
MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
Supply and fixing DOL starter for 7.5HP motor with reverse forward facility complete and single phasing preventer
Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required- 2.50 cm, 4 cm or 5 cm height
Reconditioning the existing SDF/Isolator/MCCB(32-63A) and by dismantling from existing panel/enclousure ,cleaning,heating and megger testing and re assembling, giving connection testing…etc…as required
Supply and fixing 2 A( C curve),SP MCB (C curve)(for control wiring protection)
Supply and fitting Digital Multifunction meter to read:W, Wh, PF or VA, Vah, PF or V AR, V ,A Rh, PF - 3 phase accuracy class 0.5 LED
Supply and providing LED indicators for all voltage ranges - Blue Colour
Supply and providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
CURRENT TRANSFORMER - 200/5 A, 15 VA, accuracy class 0.5, Resin Cast Metering CT
Supply & fixing the following Power Capacitors 3 phase delta connected in positon and givingconnection.3 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type suitable for direct connection to motors.
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Controllight point with 6A, plate ceiling rose - Short point
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single controllight point without ceiling rose - Short point
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single controlceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, includingproviding switch board main and continuous earthing with No.14 SWG bare copper,required quantity ofcopper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular typemetal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in theswitch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combinedplug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
Supply & installation of light fittings on 'C/U' shaped flat iron bracket<br>Supply, conveyance, installation,testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet completewith all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copperconductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.as required.1200 mm 1X20W LED Lamp with box type fixture
Supply & installation of light fittings on TW round block<br>Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
Supply and providing the 9W LED lamp in the existing fittings as required
Supply and fixing Backelite batten straight/ angle holder including connection etc. as required
Supply, conveyance, installation, testing and commissioning of LED bulk head fittings IP65 directly onwall including cutting necessary holes, giving connections with the extended orginal wiring, making good the damgaes, colour washing etc as required.(Philips/Bajaj/Havells/Wipro)
Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size,painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps
Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
Supply,conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Airdelivery minimum 210(cubic meter/minute), 300mm down rod , 2 number canopies, shackele kit, Copperwinding, 3 number blades and all remaining accessories including safety pin, nut bolts, washers suitable for 230V/240V single phase AC supply etc. complete as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12way, Double door
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure ofMCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP42/43)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and providing 4 Pole 25A AC1 rating power contactor on suitable size metal enclousure with illuminated flush head push button with LED with 24 hr timer and giving connection as required for switching street lights
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and providing 300X300X10 mm cast iron gully trap with covering at the top of the inspection chamber
Providing and fixing 25 mm X 6 mm G.I. strip earth lead from the test joint to the earth plate
Supplying and laying 25 mm X 3mm copper strip on surface or in recess for connections etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 2X 25 mm X 6 mm G.I. strip test joint for earthing system
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required - 25 x 3 mm brass bolt & nut
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required - 25 x 6 mm brass bolt & nut
Charges for cleaning and checking and heating the terminal box of street light poles
Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated using,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Hiring running charges of light crane for dismantling damaged flood light and fitting with new one on the street light post.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 50 sq mm
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 50 sq mm
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 120 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench77/63 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench90/75 mm or nearest size
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench125/109 mm or nearest size
Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays withperforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness
3 Special overhaulig works of Shutter motor
Dismantling the 6-25 HP motor into stator and rotor, cleaning the the stator and rotor thoroughly using fresh water removing the sand and mud particles from core, coil etc and removing the water and moisture content using and heating the same for 6 days to get required IR value.cleaning the windings, cleaning with petrol, attending minor repairs, retaping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning and greasing the bearings with Lithium base grease, heating and baking the windings, reassembling, test running including scrapping, cleaning and painting with 2 coats of Grey enamel paint.
Supply &changing damaged bearing of 6-25 HP motor of No,equivalent or nearest 6308
Refitting the 6-25 HP motor on base plate, levelling and correcting alignment with the pump coupling the same giving connection, testing and trail run on full load.
4 Miscellaneous items & Charges for Shifting of damaged Generator and dismantled materials
Hiring Mobile Crane for lifting the Generator and placing it on a Truck
conveyance charges for shifting generator.
Hiring Mobile Crane for lifting the Main Panel board and placing it on a Truck
conveyance charges for shifting dismantled materials and accessories from Pookkottumanna RCB site, Nilambur to electrical wing store, Malappuram.
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.
Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required
Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength.
Charges for preparation of scheme for the Electrical Installation for sheet of A3 size.
For additional copies of scheme for the Electrical Installation for sheet of A3 size.
Fee to be paid to KSELB towards scrutiny & inspection/KSEB testing charges etc
KEYAS ELECTRICALS
Bidder Name
KEYAS ELECTRICALS
RAVIKUMAR O
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .