Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC | ₹18.4 L Quoted ₹20.0 L | L1 | Accepted-AOC Over all rates are reasonable and lowest. |
| 2 | L2₹21.6 LRejected-Finance THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | ₹21.6 L | L2 | Rejected-Finance Over all rates are higher than L-1. |
| 3 | L3₹22.5 LRejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | ₹22.5 L | L3 | Rejected-Finance Over all rates are higher than L-1. |
| 4 | L4₹23.7 LRejected-Finance | ₹23.7 L | L4 | Rejected-Finance Over all rates are higher than L-1. |
| 5 | L5₹25.0 LRejected-Finance | ₹25.0 L | L5 | Rejected-Finance Over all rates are higher than L-1. |
| Sl No | Description | Qty | Unit | Ishtiaq and Sons L4 | VINYAK TRADERS L6 | PRATEEK ENTERPRISES L7 | S S ELECTRICALS L2 | D K THUKRAL AND SONS L3 | LEEJA ENTERPRISES L1 | M/S SAJJAD HUSSAIN CONTRACTOR L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. | 515.16 | Cum | 200 ₹1.0 L | 150 ₹77,274 | 130 ₹66,970.80 | 60 ₹30,909.60 | 90 ₹46,364.40 | 40 ₹20,606.40 | 50 ₹25,758 |
| 2.00 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. | 258.63 | Cum | 100 ₹25,863 | 50 ₹12,931.50 | 40 ₹10,345.20 | 30 ₹7,758.90 | 20 ₹5,172.60 | 30 ₹7,758.90 | 30 ₹7,758.90 |
| 3.00 | Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 256.53 | Cum | 75 ₹19,239.75 | 50 ₹12,826.50 | 40 ₹10,261.20 | 20 ₹5,130.60 | 20 ₹5,130.60 | 40 ₹10,261.20 | 30 ₹7,695.90 |
| 4.00 | M&L Local sand dry, filling in trenches around under ground cable complete all as specified and directed. | 206.06 | Cum | 500 ₹1.0 L | 300 ₹61,818 | 800 ₹1.6 L | 500 ₹1.0 L | 350 ₹72,121 | 150 ₹30,909 | 150 ₹30,909 |
| 5.00 | M&L for providing of new sub class 'B' Bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed. | 15.26 | Per 1000 Nos | 4,000 ₹61,040 | 4,000 ₹61,040 | 5,000 ₹76,300 | 2,500 ₹38,150 | 2,500 ₹38,150 | 1,500 ₹22,890 | 1,800 ₹27,468 |
| 6.00 | Laying only old bricks complete all as specified and directed. | 10.18 | Per 1000 Nos | 500 ₹5,090 | 1,000 ₹10,180 | 2,000 ₹20,360 | 500 ₹5,090 | 500 ₹5,090 | 1 ₹10.18 | 150 ₹1,527 |
| 7.00 | S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed.
40 mm bore | 30 | RM | 270 ₹8,100 | 200 ₹6,000 | 350 ₹10,500 | 100 ₹3,000 | 160 ₹4,800 | 50 ₹1,500 | 150 ₹4,500 |
| 8.00 | S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed.
50 mm bore | 36 | RM | 325 ₹11,700 | 300 ₹10,800 | 450 ₹16,200 | 100 ₹3,600 | 175 ₹6,300 | 50 ₹1,800 | 200 ₹7,200 |
| 9.00 | S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed.
80 mm bore | 24 | RM | 400 ₹9,600 | 400 ₹9,600 | 600 ₹14,400 | 300 ₹7,200 | 225 ₹5,400 | 80 ₹1,920 | 250 ₹6,000 |
| 10.00 | Taking out old unserviceable LT Cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts complete all as specified and directed. | 3,180 | RM | 10 ₹31,800 | 20 ₹63,600 | 5 ₹15,900 | 5 ₹15,900 | 5 ₹15,900 | 2 ₹6,360 | 5 ₹15,900 |
Updated dates
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Dec 2025, 6:00 pmClosed
GE (WEST) BAREILLY
GE (WEST) BAREILLY
MAINT/REPAIR/ REPLACEMENT OF LT CABLE DISTRIBUTION SYSTEM AND ALLIED WORKS OF WEST AREA UNDER GE (WEST) BAREILLY.
2025_MES_742056_1
8293/C/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (WEST) BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST) BAREILLY
₹70,000
Yes
30 Jan 2026
28 Nov 2025
27 Dec 2025
28 Nov 2025
25 Dec 2025
13 Dec 2025
Amount
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L Local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' Bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Laying only old bricks complete all as specified and directed.
S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed. 40 mm bore
S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed. 50 mm bore
S&F in replacement GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc of following sizes complete all as specified & directed. 80 mm bore
Taking out old unserviceable LT Cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I -1988 with aluminum conductor 1100 Volts of following sizes / grade laid in ducts or on walls, in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed. 10 Sqmm 2 core
All as Per Srl Item No 11 above but 16 Sqmm 4 core
All as Per Srl Item No 11 above but 25 Sqmm 4 core
All as Per Srl Item No 11 above but 35 Sqmm 3.5 core
All as Per Srl Item No 11 above but 50 Sqmm 3.5 core
All as Per Srl Item No 11 above but 95 Sqmm 3.5 core
All as Per Srl Item No 11 above but 150 Sqmm 3.5 core
All as Per Srl Item No 11 above but 185 Sqmm 3.5 core
All as Per Srl Item No 11 above but 240 Sqmm 3.5 core
All as Per Srl Item No 11 above but 400 Sqmm 3.5 core
Relaying only serviceable LT UG Cable obtained from exsting of any size and discription including necessary cable lugs. ( All relevent items like excavation, earth work, sand cushionning, bricks etc shall be measured seperatly under respective item of Sch.)
S&F Heat shrinkable straight through Jointing Kit suitable for 1100 volts grade XLPE insulated stranded aluminium conductor cable including testing on completion complete all as specified and directed by the Engr-in-Charge for the following size of cables :- 10 Sqmm to 16 sqmm 4 core
All as Per Srl Item No 22 above but 25 Sqmm to 50 sqmm 3.5/4 core
All as Per Srl Item No 22 above but 70 sqmm to 150 sqmm, 3.5 core
All as Per Srl Item No 22 above but 185 sqmm to 240 sqmm, 3.5 core
All as Per Srl Item No 22 above but 300 sqmm to 400 sqmm, 3.5 core
M&L in repairs of of MCB, TPN, 40 Amp, C - Curve 415 Volts, 50 Hz, Complete all as specified and directed.
M&L in repairs of of MCB, TPN, 63 Amp, C - Curve 415 Volts, 50 Hz, Complete all as specified and directed.
M&L in repairs of of MCB, SP, 6-32 Amp, C - Curve, 240 Volts, 50 Hz, Complete all as specified and directed.
S&F in repairs of MCCB 4 Pole, 415 V, 630 Amps with Microprocessor based release breaking capacity 50 KA, Ics=100% of Icu with copper spreader complete all as specified and directed.
S&F in repairs of MCCB 4 Pole, 415 V, 400 Amps with Microprocessor based release breaking capacity 36 KA, Ics=100% of Icu with copper spreader complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, 250 Amps with Microprocessor based release breaking capacity 36 KA, Ics=100% of Icu with copper spreader complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, 160 Amps with Microprocessor based release breaking capacity 36 KA, Ics=100% of Icu with copper spreader complete all as specified and directed
S&F in repairs of MCCB 4 Pole, 415 V, 200 Amps with adjustable type, breaking capacity 36 KA, Ics=100% of Icu with Copper spreader complete all as specified and directed
M&L PCC 1:4:8 type D2 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Taking out carefully interlocking paver block, of any size or shape and re-laying in the same position after removing all vegetation, algae, grass etc., laid in proper slope and gradient over sand cushioning, complete all as specified and directed.
Supply and fixing Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 80 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material including dismantling of existing tiles complete all as specified and directed.
M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with GI wire 4.00 dia connected with nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 25mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge.
M&L in replacement Earthing complete with Galvanised iron earth plate electrode 600mm x 600mm x 6mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected with galvanised earthing strip of size 25mm x 4mm by means of nuts, bots, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not esceeding 50 Mtr etc all as shown on electrical plate No.3 of MES Schedule Part-I complete including taking down and testing on completion complete all as specified and as directed by the Engineer-in-Charge.
M&L in repairs of Earth continuity conductor or main earthing lead 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire including taking down unserviceable Strip, complete all as specified and as directed.
M&L in repairs for Galvanized Iron Strip of size 25 x 4.00 mm fixed to wall or on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.including taking down old unserviceable strip complete all as specified and as directed by Engineer-in-Charge.
M&L for cleaning and preparation of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets, street light brackets, cross arms and making Black/Red/Yellow & white strips with synthetic enamelled paint of 30cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified and directed by Engr-in-charge.
Dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 mtr complete all as specified and directed.
Dismantling insulators any type any size from LT poles all as specified and directed by Engineer -in-Charge.
M&L for Pin type , porcelain, vitreous, white, borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height, 65 mm dia.
Dismantling of ACSR from the poles all as specified and directed by Engineer -in-Charge.
M&L Aluminium conductor, steel reinforced incl stringing in position all as specified and directed by Engineer -in-Charge.
S&F in repairs of PVC LT OH line spacer for 5 wires complete all as specified and directed.
S&F in repairs of PVC LT OH line spacer for 4 wires complete all as specified and directed.
S&F in repairs of PVC LT OH line spacer for 3 wires complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
S&F in repair 1100 Volts grade heavy duty cable, flat or circular PVC insulated aluminium stranded conductor of following sizes served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. 6 sqmm twin core
All as Per Srl Item No 52 above but 10 sqmm twin core
M&L in replacement fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6 mm duly wraped with RYB sleeves and fixed on porcelain insulators TPN type out door weather/vermin proof with both way opening with locking arrangement duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser 2 mm thick with one No incommer MCCB 160 Amp 25 KA incl making connection /thimbles complete all as sepcified and directed
All as per srl item 54.00 above here-in-before but of size 600 mm x 600 mm x 300 mm and without MCCB and bus bar rating 400 amp complete all as specified and directed.
M&L in replacement for Aluminium bus bar of Size 50 x 6mm with colour code & porcelain insulator suitable for 3 phase 4 wire system complete all as specified and directed.
M&L in replacement for Copper bus bar of Size 25 x 4mm with colour code & porcelain insulator suitable for 3 phase 4 wire system complete all as specified and directed.
M&L in repairs of LED indicator lamp (R,Y,B,G) including taking down old Unserviceable indicator lamps complete all as specified and directed.
M&L in repairs LED Digital Voltmeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable voltmeter complete all as specified and directed.
M&L in repairs LED Digital Ammeter, class 0.5 accuracy, 3 Phase, 415 Volts, 50 Hz, flush mounting 96mm x 96mm including taking down old unserviceable Ammeter complete all as specified and directed.
Notes:- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
S S ELECTRICALS (BID ID -3499436)
D K THUKRAL AND SONS (BID ID -3501413)
Ishtiaq and Sons (BID ID -3501245)
M/S SAJJAD HUSSAIN CONTRACTOR (BID ID -3507329)
VINYAK TRADERS (BID ID -3505651)
PRATEEK ENTERPRISES (BID ID -3497329)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_830947.xls
BOQ • 0.66 MB
COMPLETETENDER8293.pdf
Tender Documents • 1.39 MB
Download all tender documents and submit your bid