Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 CrAccepted-AOC | ₹11.0 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹11.2 CrRejected-Finance FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹11.2 Cr | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹11.7 CrRejected-Finance | ₹11.7 Cr | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹11.8 CrRejected-Finance | ₹11.8 Cr | L4 | Rejected-Finance Not lowest bidder |
| 5 | L5₹12.1 CrRejected-Finance | ₹12.1 Cr | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹11.2 Cr
EMD Value
₹8.8 L
Closing Date
9 Jun 2020, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
Chief Engineer Navy Military Engineer Services Station Road Visakhapatnam 530004
DEMOLITION OLD WARD ROOM P39B RECONSTRUCTION OF NEW ADMINISTRATIONBUILDING AT INS SATAVAHANA V
2020_MES_324858_1
CE(NAVY)/VIZ/TOKEN NO 10 OF 2018-2019
Open Tender
Civil Works
605 days
Visakhapatnam
As per NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer(P)(N)
₹8.8 L
Yes
Chief Engineer Navy Visakhapatnam
3 Aug 2020
14 Feb 2020
10 Jun 2020
14 Feb 2020
9 Jun 2020
14 Mar 2020
6 Mar 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XV: NOTE: Schedule "A" Part – I to Part – XIV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Buildings and Structures", for the Lumpsum price of Rs. 4,00,00,000.00 inserted by MES as listed in Schedule "A" Part – I on Serial Page No. 35[R]
Lumpsum price worked out by the contractor for " [SITE CLEARANCE , EARTHWORK AND EXCAVATION]", for the Lumpsum price of Rs. 46,73,47.45 inserted by MES as listed in Schedule "A" Part – II on Serial Page No. 37
Lumpsum price worked out by the contractor for " PILE FOUNDATION", for the Lumpsum price of Rs. 1,60,20,837.42 inserted by MES as listed in Schedule "A" Part – III on Serial Page No. 39[R]
Lumpsum price worked out by the contractor for " INTERNAL WATER SUPPLY", for the Lumpsum price of Rs. 12,45,68.90 inserted by MES as listed in Schedule "A" Part – VI on Serial Page No. 41
Lumpsum price worked out by the contractor for "[INTERNAL ELECTRIC SUPPLY ]", for the Lumpsum price of Rs. 11,75,046.60 inserted by MES as listed in Schedule "A" Part – V on Serial Page No. 44[R]
Lumpsum price worked out by the contractor for "[EXTERNAL WATER SUPPLY]", for the Lumpsum price of Rs. 2,00,654.40 inserted by MES as listed in Schedule "A" Part – VI on Serial Page No. 46
Lumpsum price worked out by the contractor for " [EXTERNAL ELECTRIC SUPPLY]", for the Lumpsum price of Rs. 16,50,629.40 inserted by MES as listed in Schedule "A" Part – VII on Serial Page No.48
Lumpsum price worked out by the contractor for "[ROAD, PATH AND CULVERT] ", for the Lumpsum price of Rs. 15,36,742.28 inserted by MES as listed in Schedule "A" Part – VIII on Serial Page No.52[R]
Lumpsum price worked out by the contractor for " [SEWAGE DISPOSAL]", for the Lumpsum price of Rs.2,05,505.30 inserted by MES as listed in Schedule "A" Part – IX on Serial Page No.55
Lumpsum price worked out by the contractor for "[AREA DRAINAGE]", for the Lumpsum price of Rs.6,44,316.80 inserted by MES as listed in Schedule "A" Part – X on Serial Page No. 58
Lumpsum price worked out by the contractor for "[RAIN WATER HARVESTING]", for the Lumpsum price of Rs.71,968.48 inserted by MES as listed in Schedule "A" Part – XI on Serial Page No. 60
Lumpsum price worked out by the contractor for "[LIGHTING PROTECTION]", for the Lumpsum price of Rs.68,053.60 inserted by MES as listed in Schedule "A" Part – XII on Serial Page No. 62
Lumpsum price worked out by the contractor for "[FIRE FIGHTING AND FIRE ALARM]", for the Lumpsum price of Rs.37,99,383.10 inserted by MES as listed in Schedule "A" Part – XIII on Serial Page No. 68
Lumpsum price worked out by the contractor for "[ARBORICULTURE]", for the Lumpsum price of Rs.1,15,603.00 inserted by MES as listed in Schedule "A" Part – XIV on Serial Page No. 69
Schedule "A" Part - XV MISCELLANEOUS ITEMS FOR PILE FOUNDATION, INTERNAL WATER SUPPLY, INTERNAL ELECTRIC SUPPLY, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIC SUPPLY, FIRE FIGHTING AND FIRE ALARM, ROAD, PATH AND CULVERT , LIGHTING PROTECTION, WATER COOLERS, DG SET, LIFTS, AVIATION LIGHTS, AIR CONDITIONING, PVC CONDUITS, ARBORICULTURE, COMPREHENSIVE MAINTANCE OF LIFT (TO BE QUOTED BY THE TENDERER)
PILE FOUNDATION
Boring for bored cast-in-site piles 600mm dia in any strata except SDR/hard rock and getting out and disposal of spoil out side MD land using Hydrailic system of boring method complete all as specified and as directed.
Boring for bored cast-in-site piles 450mm dia in any strata except hard rock and getting out and disposal of spoil out side MD land using Hydrailic system of boring method complete all as specified and as directed.
Boring for bored cast-in-site piles 600mm dia in SDR/soft rock and getting out and disposal of spoil out side MD land using Hydrailic system of boring method complete all as specified and as directed.
Boring for bored cast-in-site piles 450mm dia in SDR/soft rock and getting out and disposal of spoil out side MD land using Hydrailic system of boring method complete all as specified and as directed.
Carrying out intial load test on 600mm dia pile as per IS 2911 part IV complete all as specified and as directed.
Carrying out intial load test on 450mm dia pile as per IS 2911 part IV complete all as specified and as directed.
Carrying out routine load test on 600mm dia pile as per IS 2911 part IV complete all as specified and as directed.
Carrying out routine load test on 450mm dia pile as per IS 2911 part IV complete all as specified and as directed.
Carrying out pull out test cast in situ piles 600mm dia pile as per IS complete all as specified and as directed.
Carrying out pull out test cast in situ piles 450mm dia pile as per IS complete all as specified and as directed.
Carrying out lateral load test cast in situ piles 600mm dia pile as per IS complete all as specified and as directed.
Carrying out lateral load test cast in situ piles 450mm dia pile as per IS complete all as specified and as directed.
Carrying out low strain integrity test on bored cast in situ piles including analysing the result as per ASTM D 5882 and as directed by Engg-in-Charge.
INTERNAL WATER SUPPLY
Health faucet, cast copper alloy, chromium plated fancy type for 15mm bore including stainless steel flexible hose of 1.2m and wall hook complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY
Supply & Fix energy efficient LED light fitting with tube 20 watt, 230V surface mounted LED batten type with extruded polycorbonate body and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Bajaj
Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and earth work in any type soil, PCC 1:2:4 type B-2 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe connected upto DBs, and suitable C.I top cover with handle, funnel, strainer, charcoal and testing on completion all as specified and directed. Note- Rate quoted deemed to be included excavation and earth work in any type of soil with PCC type B2 in pad and pit complete all as specefied and directed. (For TPN 4 way DB's)
Supply & Fix energy efficient LED light fitting with tube 10 watt, 230V surface mounted LED batten type with extruded polycorbonate body and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply & Fix energy efficient LED down lighting ceiling light fitting 18 watt, integral round shape, 230V with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Suppy & fixing energy efficient ultra modern designed architectural LED luminaire which provides soft light and glare free symmetrical illumination 36watt, 230V, ceiling light recess mounting type including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply & Fix energy efficient LED mirror light fitting with tube 5 watt, 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply & Fix LED lamp 7 watt for batten holder.
Supply & Fix LED building security light fitting energy saving and environmental friendly long life made up of pressure die cast aluminium hosing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 including electronic driver pre wired with 1.5 sqmm copper conductor cable upto connector including 2Mtr long GI tubing medium grade 40mm dia bend to shape fire brackets fixing on wall with suitable clamps complete all as specified and as directed.
Supply & Fix ceiling fans AC single phase 230V of size 1200mm sweep with complete set with fixtures, 5 Star rating, metalic body comple all as specified and as directed.
Supply & Fix exhaust fans 300 mm sweep or nearest size, plastic body, complete with louvers suitable for operation on 230V AC, 50Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc comple all as specified and as directed.
Supply & Fix exhaust fans 380 mm sweep or nearest size, metal body, complete with louvers suitable for operation on 230V AC, 50Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc comple all as specified and as directed.
Supply & Fix Vertical on load MCCB TPN DB 4 way 415V, 50Hz double door, IP 43 protection with 200A rated bus bar for provision as incommer and MCBs for outgoing circuits complete, fill empty with blanks, making good the making good the distrubered surfaces etc comple all as specified and as directed.
Supply & Fix Telephone jack with shutter, RJ45 including GI box, inner and cover plates comple all as specified and as directed.
EXTERNAL WATER SUPPLY
Cutting existing steel tubing of 150/200 dia for alterations or additions necessarily done in position without taking down, dewatering for inserting flanged sockets, 'Tee' with reducer to 80 mm, etc for tapping all as specified and directed.
Masonry valve chamber 750 x 750 x 750 for valve including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type C1 coping 50 x50x6 mm angle iron 6 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as specified and as directed.
Supply, install, testing and commissioning of Monoblock pump set with minimum ratings as 7.5 HP, 44 Mtr Head, 4.7 LPS centrifugal pump set with delivery size of 80 mm bore, 415 Volts, 50 Hz, AC 3 Phase supply, electric driven, inclusive of pressure guage along with cabling by Copper cables from starter to Pump set with cable tray and PCC foundation. all as specified and directed .
Supply and fix Star delta starter of 7.5 HP capacity with all connection all as directed.
EXTERNAL ELECTRICAL SUPPLY
Supply & Fix and testing of Integral LED street light Luminaire 72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing all as specified and directed.
Loop in Loop out thermosplastic cable junction boxes of size 250 x 250 x 100 mm made out of 1.6 mm thick MS Sheet comprising with MCB SP 4 A and 4 Porcelain terminals as bus terminals for cable with necessary fixing arrangemets with cable glands, etc preparing the surface and appling two coats of synetic enamel paint over a coat of primer etc all as directed. (for Security Lights)
Supply and fix time switches 415 V threePhase of 20 Amp rating with contactor Fitted inside steel enclosure (for street Lights control) all as specified and as directed
Supply and fix wall mounted/ floor mounted 4 pole MCCB 400 Amp,50 KA breaking capacity microprosssor release adjustable type, with Encloser made up of CRCA sheet of 2 mm thick front door operated, weather and water proof with necessary locking arrangements along with lugs, cable glands of suitable size for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting cables and the nuts/ bolts etc used are to be made of rust proof material complete with powder coating, necessary internal electric connection as required with LED indicating lamps for each phase all as directed.(to be fixed in Substation of SAU)
Suppy fixing and testing of LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and nutral, four wire LT AC, 50 Hz 415 V 600 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:
Incoming:
a) LT 440 volts 3 phase, 4 wire 50 cycles, 50kA, microprosssor release ,Adjustable type MCCB of 400 Amp rated complete with overload protection, microprocessing released display type - 01 Nos.
Outgoing:
b) LT 440 volts 3 phase, 4 wire 50 cycles, 35/36kA, microprosssor release ,Adjustable type MCCB of 315 Amp rated complete with overload protection, microprocessing released display type - 2 Nos (for bldg panel and spare)
c) LT 440 volts 3 phase, 4 wire 50 cycles, 35 kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no-volt thermal based release. - 03 Nos (for APFC,DG AMF Panel and spare)
d) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases-03 Nos
e) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, THD along with connected CTs.
Suppy fixing and testing of LT Panel board made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Copper bus bar of 500 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following: (bldg panel)
Incoming:
a) LT 440 volts 3 phase, 4 wire 50 cycles, 50kA, Adjustable type MCCB of 315 Amp rated complete with overload protection, microprocessor release type - 01 Nos.
Outgoing:
b) LT 440 volts 3 phase, 4 wire 50 cycles, 36 kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, microprocessing released display type.- 07 Nos. (for bldg and spare)
c) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases-01 Nos
d) Multifunctional Panel Meter digital type for measuring Volts and Current, along with connected CTs.
Suppy fixing and testing of LT Panel board made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Copper bus bar of 200 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (DG supply standby Panel)
Incoming:
a) LT 440 volts 3 phase, 4 wire 50 cycles, 35/36 KA, Adjustable type MCCB of 125 Amp rated complete with overload protection, microprocessing released - 01 Nos.
Outgoing:
b) LT 440 volts 3 phase, 4 wire 50 cycles, 25 kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, microprocessing released - 02 Nos. (Lift Panel and spare)
c) LT 440 volts 3 phase, 4 wire 50 cycles, 25 kA, Adjustable type MCCB of 32 Amp rated complete with overload protection - 02 Nos. ( for terrace tank and spare)
d)MCCB AC 3 Phase 415 V, 50Hz 4 pole 25 A capactiy 15/16 KA with Adjustable type (for street light, Spare) - 01 Nos
e) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases-03 Nos
f) Panel Meter digital type for measuring Volts, Current, Hz, pf, along with connected CTs.(Make:Schinder / L&T)
Material and Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 X 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel using galvanised iron strip 32×6mm and 50 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipe as earthing leadall as shown in electrical plate No. 03 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed.
Galvanised iron strip of size 32 x 6mm with saddles and fixing screws etc for roof/wall complete all as specified.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and as directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size all as specified and as directed.
Supply and fix sheet metal encloser ,provision of fixing incoming and out going cables with bus bar for cable connection tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 150 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For lift machine room) Incomming:- (a) MCCB 100 Amps,25 KA - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TP - 04 Nos(01 for each lift + 01 Spare) (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
FIRE FIGHTING AND FIRE ALARM
Supply laying and testing of Ductile Iron pipe with double flanged centrifugally cast(spun) class K-9 of 150mm dia pipe conforming to IS-8329 including provision of fittings, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning all as specified and directed.
Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 36 m head, 450 LPM discharge with minimum pressure of 2.0 kg/sqcm along with starter panel all as specified and directed.(for sprinkler system)
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and as directeed.
Supply and fix GI cable tray with cover for fixing XLPE cable from duty room to terrace for siren and at various places to accommodate the cables for MCPs, panel etc of size not less than 75x38 mm with necessary bends,angles,supports for fixing,etc all as specified and as directed
Cutting existing ring main of 150 mm dia for tapping and including insertion of 'Tee of 150x150x150 mm' without taking down, dewatering including all acessories as required etc for tapping of ring main all as specified and directed.
ROAD, PATH AND CULVERT
Concrete bed to 600mm drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in 1:3:6
Concrete bed to 450mm drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in 1:3:6
LIGHTING PROTECTION
Earthing complete with galvanized earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts checknuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 50 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe for watering all as specified and directed and tested on completion.
WATER COOLERS
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour with stainless steel body all as specified and directed.
Supply fix and testing of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 kVA all as specified and directed.
DG SET
Supply Instal and commissiong Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 82.5 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-
(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design
(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.
(A) Alternator :- Standard design alternator rated at 82.5 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722
i) Insualation class - 'H‘
ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by
accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under
i)Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump
vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan
Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display.
xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine
xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling
xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms xv) Fuel Tank :- Fuel Tank of capcaity to suit Daily 12 hours run service fuel tank made out of 2mm thick (14G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base in side the accoustic enclosure.
xvi) MS pipe line to and from the fuel tank to the DG Set
C) AMF Panel :- Factory made inbuilt type control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 82.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc
g) Annuciation with indication lamps for : (i) Low lub oil pressure.
(ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low voltage
Controls :- a) Load on Indication b) Load off indication c) Engine start push button d) Engine stop push button e) Fault accept / reset push button
f) Battary Charger : (i) Transformer (ii) Rectifier
D) Accoustic Enclosure:- Manufactured by OEM suitable for 82.5 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board
(iii) The generating set battaries and control panel should be inside the enclosure. (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick
c) Sound Insulation :- As per OEM Norms vi) The accoustic should be composite in construction and fully assembled integral unit
vii) The batteries should be placed inside the enclosure the DG Set. viii) The fuel tank is to be located inside dg set
ix) The DG Set should be provided with external Emergency stop push button x) The enclosure should be suitably illuminated by LED Lamp fittings. xi) The noise level should be 75 dba at 1m under free field conditions.
xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade
E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 2. 4 x 0.8 m for placing of DG Set complete all as specified and directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 X 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel using galvanised iron strip 32×6mm and 50 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipe as earthing leadall as shown in electrical plate No. 03 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed.
LIFTS
Design supply, install testing & commissioning 13passengers lift (884 kg) speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS14665, suitable to serve G+5 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified and directed.The lift shall be provided with and including the following
Battery operated emergency light(LED ceiling type) alarm (speaker for emergency alarm system) and stop button in car with rechargeable arrangement of battery.
Two sleek circular light fitting false ceiling d) One sleek circular PVC heavy duty fan in false ceiling
Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one more and top covering with PVC flooring complete.
Non stop button/independent operation
Overloading warning indicator visual type
Front landing door of stainless steel moon roc finish operation with minimum time of 10 seconds and up to a maximum time of 30 seconds
Car size shall be in confimity with IS-3534-1976 and body to be stainless steel of 16 gauge moonrock finish with stainles steel hand rail 38 mm hairline finish.
Set of there in number limit switches at bootom and top most position of lift hosit way as specified in lift IS
Specification plate with complete details
Continous earthing for machine and equipments
Wire rope of adequate size as per relevent IS and as per manufacturer specification
Other standard features and fittings like guide rails,sheaves, counter weights with guards, buffers gear unit breakes, control panel, locks governer, car operational pnel, power control and trailing cables complete as specified
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip size 32mm X 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, but using galvanised iron strip 32x6mm as earthing lead complete all as specified and as directed by the Engineer-in-Charge.
AVIATION LIGHTS
Aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements all as specified and as directed. Make : Bajaj Cat NO. BGAB302 LED
Cable PVC insulated FRLS PVC Armoured 2.5 sqmm 3 core cable multi stranded conductor laid in ground fixed to wall all as specified and as directed.
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor Fitted inside steel enclosure
AIR CONDITIONING
Supply and install,testing wall mounted split units Indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with latest Inverter Technology of capacity 2 TR all as specified and directed.
Supply and install,testing wall mounted split units Indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with latest Inverter Technology of capacity 1.5 TR all as specified and directed.
Supply and fix Metal clad 20 Amps 2P+E all as specified and directed.
PVC CONDUITS
Supply and fix Rigid non-metallic PVC conduit of size 25 mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in wall or clamped on wall all as specified and as directed.
Telephone socket/jack with shutter, Modular Type, one Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS sheet, Modular type Base/ Grid Frame & cover Frame complete all as specified and as directed.
TV/ Socket / outlet, Deluxe, Modular Type, one modular including suitable Modular Type pressed Metal Flush Box made out of 2 mm thick MS sheet, Modular type Base/ Grid frame & cover frame complete all as specified and as directed.
ARBORICULTURE
Supply and planting carpet grass by piece turfing including preparation of ground upto 30cm deep and filing soft soil, cow dung and watering and removal of soil outside MD land etc complete. Note: Loose soil and cow dung will measured separately.
Supply and planitation of crotons and hedges, including preparation of ground to required depth and filling of good earth, cow dung and watering etc, complete all as specified and as directed by the Engineer-in-Charge.
Suply and plantation of Ashoka plants height of plant not less than 45cm above ground level including preparation of ground upto 60cm deep and filling of good earth, cow dung, vermi compost and watering etc, complete all as specified and as directed by the Engineer-in-Charge.
Supply and plantation of Palm tress including preparation of ground upto 30cm deep and filling of good earth, cow dung, vermi compost and watering etc, complete all as specified and as directed by the Engineer-in-Charge.
Supply of best quility loose (Sweet earth) for planatation complete as per gardening practice and all as specified and as directed by the Engineer-in-Charge.
Supply of approved Manure (Cow dung) complete as per gardening practice and all as specified and as directed by the Engineer-in-Charge.
Supply of vermi compost of best quality complete as per gardening practice and all as specified and as directed by the Engineer-in-Charge.
PHASE-II: COMPREHENSIVE MAINTANCE OF LIFT FIRST YEAR AFTER EXPIRY OF DEFECT LIABILITY PERIOD.
PHASE-III:COMPREHENSIVE MAINTANCE OF LIFT SECOND YEAR AFTER EXPIRY OF DEFECT LIABILITY PERIOD.
PHASE-IV:COMPREHENSIVE MAINTANCE OF LIFT THIRD YEAR AFTER EXPIRY OF DEFECT LIABILITY PERIOD.
Note for SL No: 171.00 to 176.00:- Comprehensive maintenace consists of preventive and breakdown services including replacement of minor consumables like topping of gear oils/grease/door reollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performence once in a year complete and rate quoted by the tenderer includes the above 03 nos Lifts
(ii) Preventive maintance consists of carrying out routine check by skilled personnel as specified in Paticular specifications and as recommned by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart.
(iii) Breakdown maintance consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur diring the operation.
(iv) Fortnightly, quarterly maintaince registers shall be maintained and signed by the site engineer and contractor
(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carriedout as and when directed by Engr -in-Charge.
MURALI KRISHNA ASSOCIATES
B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED
S V S ENTERPRISES
SVS PROJECTS
k.ramakrishnarao and co
anjaliinfratech
BHARATSHAH CONSTRUCTION CO
K KUMAR RAJA PROJECTS P LIMITED
Sowrya Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid