| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.6 L+₹3.2 L (8.58%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹40.7 L+₹3.3 L (8.87%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹42.6 L+₹5.2 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹44.6 L+₹7.2 L (19.2%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹47.8 L
EMD Value
₹95,520
Closing Date
4 May 2024, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361150
Special repairs to CPOs Single Living Accn (Bldg No. P-65) at INS Valsura, Jamnagar
2024_MES_648214_1
8739/VAL/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) Navy Jamnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹95,520
Yes
16 May 2024
28 Mar 2024
6 May 2024
28 Mar 2024
4 May 2024
22 Apr 2024
Amount
Taking down cement plaster of any description on PCC/stone surface/brick surfaces including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (above or below ground level) and removal of entire debris as ordered outside MoD land complete all as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and stacking at site where directed and removal of debris as ordered outside MoD land complete all as specified & as directed.
Dismantling mangalore pattern roofing tiles with ceiling tiles or slate roofing including ridges complete all as specified & as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MoD land complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down chowkat or frame with shutters (including grills, fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0 Sqm each with shutters (without taking off shutters from frame) and refixing in the same opening as ordered after other repair works are carried out complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening as ordered after other repair works are carried out including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as directed.
M&L for post construction Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.
M&L for post construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litres per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same to match with the existing finish complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
M&L for reinforced cement concrete 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork and scaffolding complete all as specified and as directed. Note : Reinforcement shall be measured and paid for separately.
Supply only Integral Water Proofing Compound (ISI Marked).
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
Cutting chases in brick/ stone wall, pinning in, making good to facing where required and plastering in CM 1:4 to ends of edges of landing, steps, cills, lintels etc and cutting chases not exceeding 10 cm girth for concealed water tubing and similar works and making good cutting as per its original specfication complete all as directed.
M&L for cutting holes in brick/stone walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as required including making good as per its original specification without any extra cost, exc. half brick but not exc. one brick thick (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall).
M&L for Second class hard wood battens spaced at 30cm centre to centre, clean sawn, cross sectional area exceeding 15 sqcm but not exc 25 sqcm, including taking down old unserviceable/ decayed battens, complete all as specified and as directed.
Dismantling carefully existing serviceable second class hard wood battens of cross sectional area exceeding 15 sqcm but not exc 25 sqcm spaced at 30cm centre to centre, clean sawn, and re-fixing the same at old or new position spaced at 30cm centre to centre, complete all as specified and as directed.
S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.
S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.
S&F factory made 35 mm thick second class hard wood glazed and skeleton door shutter open rebated and prepared to receive glass, guage etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (a), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats, complete all as specified and as directed.
S&F factory made 30 mm thick second class hard wood glazed and skeleton window shutter open rebated and prepared to receive glass, guage etc edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (b), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats complete all as specified and as directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window / Ceosetory windows & other Frames/ Chowkhat of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/sqmm, modules of elasticity 900 N/sqmm and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: MS hold fast/ lugs/ SS dash fasteners shall be measured and paid for separately.
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer -In- Charge. Note: Stainless steel butt hinges and necessary SS screws shall be measured and paid for separately.
S&F 200 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 125 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 75 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 100 mm size stainless steel butt hinges (ISI Marked), medium weight.
S&F 200mm size extruded aluminium alloy handles (ISI Marked), fabricated type, anodised and fixed.
S&F 150mm size extruded aluminium alloy handles (ISI Marked), fabricated type, anodised and fixed.
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F mild steel 300mm ordinary rat tail rod pattern spring including roller and roller plate, complete all as specified & as directed.
S&F gate and shutter, hooks and eyes, aluminium plate type II, 125 mm size.
S&F 70mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door as directed. Note :- Door stopper shall be conforming to the sample kept in GE’s office.
S&F XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
S&F in repairs XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
S&F in repairs stainless steel drapery rod of 25mm dia (in lengths as directed) with & including stainless steel decorative SS bulb type finial at both ends / SS end socket and pair of stainless steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-410 W (Gde E-250) quality-A complete all as specified and as directed.
S&F plain mild steel wire 4.00 mm dia, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc. as directed (each line of wire to be measured) complete all as directed and as specified.
S&F GI chicken wire mesh cut to size made to shape as ordered including fixed to walls with nails for receiving the plaster complete all as directed. Note : Weight of GI chicken wire mesh shall be 250 to 300 gm/Sqm.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames and shutters for doors, windows and ventilators with one or more rebates including joining cleat for fixing, anodised aluminium snap on beading, neoprene gasket, powder coated aluminium handles of suitable size, etc. complete all as specified and as directed.
S&F aluminium powder coated grill 8mm thick 75x75mm diagonal spacing, fixed with necessary H/F/C channel etc complete all as specified and as directed. Notes : (i) Aluminium powder coated grill shall be fixed with windows with all fittings as directed by Engineer-in-Charge. (ii) Powder coating of colour as directed.
S&F stainless steel (Grade-316) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dah fasteners, stainless steel bolts etc, of required size for gate with suitable arrangement as per approval of Engineer-in-Charge. (for payment purpose only weight of stainless steel members shall be considered exclusing accessories such as nuts, bolts, faterners etc).
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets and S&F new 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including MS powder coated (white) snap Grid of size 605x605 mm frame work using 24mm x 32mm x 0.7mm main ‘Tee’ runner to be interlocked, 24mm x 32mm x 0.70mm cross ‘Tee’ and 24mm x 32mm x 0.70mm angles fixed to wall for ceiling including necessary supporting hanger with 4 mm dia GI wire (upto 3.5m long adjustable) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 24x7mm size 60mm long for securing frame work to ceiling suspended @ 1200mm centre to centre both way with PVC rawl plug with & including 6mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer’s instructions, with & including painting the ceiling board with two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer on ceiling with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of false ceiling work including testing on completion as ordered complete all as specified & as directed.
S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and as directed.
All as per item No. 53 here-in-above, but except sheeting. Note : Roofing sheets obtained serviceable from serial item No 6 here-in-above shall be used under this item.
S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
M&L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry including cutting holes through tiling for pipes and making good the disturbed surface to its original specification complete all as specified and as directed.
All as per item No. 56 here-in-above, but except roof tiles. Note : Roofing tiles obtained serviceable from serial item No 7 here-in-above shall be used under this item.
M&L for Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed.
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
M&L for average 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in levelling course, floors, padding over roof, etc complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
M&L for 18 to 20 mm thick Marble (best quality) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of Marble over & including 20mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for 16 to 18 mm thick granite slab (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for rendering 20mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work of walls mixed with WPC @ minimum 2% by weight of cement or as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on ceiling complete all as specified & as directed.
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.
Taking down or up damaged/ old GI pipe of 15 mm bore and S&F new 15 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Taking down or up damaged/ old GI pipe of 20 mm bore and S&F new 20 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Taking down or up damaged/ old GI pipe of 25 mm bore and S&F new 25 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
S&F in repairs 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm, fixed to wall/ ceilings or in floors etc. complete all as directed.
S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe or brass ferrule of 25 mm bore and fixed (minimum weight 455 gms) complete all as specified and as directed..
S&F in repairs 15 mm bore two way bib tap fancy type, brass, chromium plated with flange and aerator, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6512 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs health faucet brass chromium plated with wall hook and 1 metre SS braided rubber hose pipe and wall hook mounted type complete all as specified and as directed. Make: Prayag Cat No. BEA-85 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed. Make: Prayag Cat No. 6510 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs chromium plated 100mm over head ABS shower round with 225mm SS Arms & Flange, swivel joints fixing to steel pipes etc complete all as directed. Make : Prayag Cat No BS-65 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repair CP brass soap dish including fixing with brass screws complete all as specified & as directed. Make : Prayag Cat No BA-45 or equivalent in makes mentioned in Appendix 'B' here-in-after
S&F in repairs 15 mm bore, brass, chromium plated, wall mixer with L bend and one for shower rose, screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe complete all as directed. Make: Prayag Cat No. 7375 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore, brass, chromium plated, central hole WHB mixer W/O pop up for hot and cold water mixing, screwed for iron pipe complete all as directed. Make: Prayag Cat No. 6850 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 50cm long between flanges complete all as directed. Make : Prayag Cat No BA-01 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs CP Brass toilet paper holder with flap guard complete all as specified and as directed. Make: Cat Part No BA-08 of Prayag or equivalent in makes mentioned in Appendix ‘B’ here-in-after.
S&F in repairs grating square 140 mm size of stainless steel and fixed complete all as specified & as directed.
S&F in repairs PVC connections 15mm dia, 600mm long with PTMT nuts & washers at both ends.
S&F in repairs PVC flexible waste pipe for 32mm dia waste coupling complete all as specified and as directed
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in floors/ fixed to walls, complete all as specified & as directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 75mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F PVC (SWR) Vent cowl 75mm bore size fixed complete all as directed.
S&F PVC (SWR) Vent cowl 110mm bore size fixed complete all as directed.
S&F in repairs PVC (SWR) floor trap plain with grating including jointing with solvent cement, diameter of outlet 75mm, complete all as specified & as directed.
S&F in repairs PVC (SWR) gully trap 125/110 mm including jonting the same with solvent cement complete all as specified & as directed.
S&F in repairs vitreous china oval shape counter sunk wash hand basin (white) of size 560mm x 470mm x 190mm with & including 32 mm dia PVC waste pipe and 32mm chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed complete all as specified & as directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, complete all as specified & as directed.
S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified and as directed.
Dismantling of existing any type & any capacity water storage tank fixed in any description and S&F new 500 litres capacity (white colour) virgin food grade Plastic rectangular water storage tank with closed top for Loft with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed. Make : Sintex 'Loft' or equivalent in makes mentioned in Appendix 'B' here-in-after.
M&L for providing and laying water proofing treatment on roofs of slabs / sunken floors consisting of & including the following :- (a) After preparation of surfaces, apply first layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic Polymer TAPCRETE P 151 of CICO Chemicals @ 0.253 kg/sqm. (b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with Acrylic Polymer TAPCRETE P 151 of CICO Chemicals and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment shall be taken upto 30 cm on parapet / side wall and tucked into groove in parapet / side wall all around. (d) Provide oil bound bituminous primer @ 0.30 Kg/Sqm and provide minimum 3mm thick plain APP based modified polymeric water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 150 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed. Notes : (i) The work shall be carried out only through specialised agency approved by GE. (ii) The net area of water proofing treatment shall be measured without any extra allowance for laps. (iii) Equivalent product of Fosroc / Dr. Fixit / Pidilite / Sika shall be allowed as per approval of GE.
M&L for application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR latex per bag of cement {Compressive strength after 28 days ≥ 40 N/sqmm (According to ASTM C109)} in small patch work over column/ beams/ ceilings / walls surfaces 20 to 30mm thick in two layers over a coat of bonding agent like Nitobond SBR (1 ltr SBR + 3 Kg cement) applied as per manufacturer’s instructions for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Note :- SBR latex chemical shall be measured and paid for separately as ‘Supply only’.
Supply only SBR latex chemical of Make Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian as approved by GE.
E&M Items: Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new PVC modular box, terminal plates with all accessories, concealed PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including top cover modular plates, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
All as per serial item No. 122 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
All as per serial item No. 122 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 122 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed.
S&F in repairs modular switch, single pole, one way, 16 Amp, 1 module with all accessories complete all as directed.
S&F in repairs modular socket 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs modular socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs modular bell push 6A, one way, 1 module with all accessories complete all as directed.
S&F in repairs bell, Ding Dong/Multi music type, 240 Volt AC supply complete all as directed.
S&F in repairs modular type TV socket outlet modular type, 1 module complete.
S&F in repairs modular type RJ 11 Telephone socket, 1 module complete.
S&F in repairs 20 mm dia rigid non-metallic PVC conduit (heavy duty, ISI marked) exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends, etc and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
M&L for metal flush boxes concealed for mounting TV /Telephone socket etc including logic modular plates and surrounds of suitable size including dismantling existing box.
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
Taking down existing light fitting of any description & fixed in any position and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No.LGLZ01X020XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fitting of any description & fixed in any position and S&F new 10 Watt wall mounted 2 ft glaze LED batten, CCT 6500K, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No. LGLZ01X010XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fittings in aluminium pressure die cast housing with toughened glass cover (IP 66 protection), having CCT 5700K and Sytem lumen efficacy >120 Lm / W, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed over & including mounting bracket made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed. Make: Jaquar Cat No. LSRT01S045XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep with service value 6.00 BEE 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1.5 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint including taking down existing old ceiling fan and depositing to MES store yard complete all as specified and as directed. Make: Bajaj Model No. ENERGOS 28 1200 MM GLOSSY WHITE CF (Without Remote) or equivalent in makes mentioned in Appendix 'B' here-in-after. Notes :- (i) The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates. (ii) Old Ceiling Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
S&F in repair modular step type fan regulator 120 W, 2 module, AC, 230V, electronic complete all as specified and as directed.
S&F 250mm sweep, PVC body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter venti Air and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard complete all as directed by Engineer-in-Charge. Make: Bajaj Maxima DLX 250 mm White Dom EX fan or equivalent in makes mentioned in Appendix 'B' here-in-after. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.
S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one Single Pole MCB 20 Amps, 'C' Curve complete all as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, VTPN, TPN, Vertical, 4 Way, flush mounted & surface mounting, suitable for fixing 3 Pole / 4 Pole MCCBs & MCBs, 415 Volts with 200 Amps rated bus bar, DB fitted with bus bar neutral links blank plates, fitted with and including MCCB, 4 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal Magnetic Protection - 01 No., complete all as specified and as directed. Make of DB :- Legrand Cat No. 5077 50 or equivalent in makes mentioned in Appendix 'B' here-in-after. Make of MCCB :- Legrand Cat No. 4200 55 or equivalent in makes mentioned in Appendix 'B' here-in-after. Note : (i) Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) Quoted rates shall be inclusive of DB & MCCB as above. (iii) DB & MCCB of same make shall be provided.
S&F in repair MCCB, 4 Pole, 125 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal Magnetic Protection, connecting with proper size link set at incoming and outgoing cable end with cable connections complete all as directed. Make: Legrand Cat Part No. 4200 96 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
S&F in repairs MCB SPN 40 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply and laying/fixing 50 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
JAMNAGAR ELECTRIC AND MACHINERY CO
1R K Traders
Dhangot Brothers
Magnus Enterprise
SohanandCompany
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .