Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.4 CrAccepted-AOC FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹8.4 Cr | 1 | Accepted-AOC Being Lowest Bidder |
| 2 | 2₹8.8 Cr+₹39.6 L (4.69%)Rejected-Finance | ₹8.8 Cr+₹39.6 L (4.69%) | 2 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹8.4 Cr
EMD Value
₹7.4 L
Closing Date
26 Nov 2020, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
Provision of Deficient Office Accommodation for CWE, Visakhapatnam
2020_MES_380508_1
82062 / E8
Open Tender
Civil Works
Lump-sum
1640 days
Visakhapatnam
Class S
Category a i
10 documents required · 10 mandatory
₹3,000
Garrison Engineer Naval Depot
₹7.4 L
Yes
23 Dec 2020
25 Sept 2020
3 Dec 2020
25 Sept 2020
26 Nov 2020
12 Nov 2020
25 Sept 2020 - 10 Oct 2020
Amount
Schedule "A" Part – I to Schedule "A" Part – XIII: Note: Schedule "A" Part – I to Part – XIII are reprised by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "Buildings & Structures", as listed in Schedule "A" Part – I on Serial Page No. 29 [R].
Lumpsum price worked out by the contractor for "Site Clearance / Area Development / Earthwork Excavation", as listed in Schedule "A" Part – II on Serial Page No. 30 [R].
Lumpsum price worked out by the contractor for "Road / Path / Hardstanding", as listed in Schedule "A" Part – III on Serial Page No. 33 [R].
Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – IV on Serial Page No. 35 [R].
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – V on Serial Page No. 37 [R].
Lumpsum price worked out by the contractor for "Arboriculture", as listed in Schedule "A" Part – VI on Serial Page No. 38 [R].
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – VII on Serial Page No. 40 [R].
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – VIII on Serial Page No. 42 [R].
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – IX on Serial Page No. 43 [R].
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – X on Serial Page No. 47 [R].
Lumpsum price worked out by the contractor for "Lightening Protection", as listed in Schedule "A" Part – XI on Serial Page No. 48 [R].
Lumpsum price worked out by the contractor for "Fire Fighting System", as listed in Schedule "A" Part – XII on Serial Page No. 52 [R].
Lumpsum price worked out by the contractor for "Fire Alarm System", as listed in Schedule "A" Part – XIII on Serial Page No. 53 [R].
Schedule "A" Part – XIV: [Miscellaneous Items] [Arboriculture, Internal Water Supply, Internal Electrification, External Water Supply, External Electrification, Lightening Protection, Fire Fighting System, Fire Alarm System, DG Set and Lifts]:
Supply, plantation and developing of Korean / Mexican Carpet Grass including necessary earthwork excavation to a depth not exceeding 30cm in any type of soil, removing the Weeds, Roots and Vegetation, filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. and applying Soil Pesticide, transplanting of Carpet Grass including cost of Good Earth, Manure, Pesticides, Grass etc. complete all as specified and as directed.
Supply, plantation and developing of Ashoka Plant [height of plant not less than 1.20m above ground level and of age 6 Months] with proportional girth, evergreen species including preparation of ground up to 0.45m deep and of size 450 X 450mm and filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. complete all as specified and as directed.
Supply, plantation and developing of Royal Palm Plant [height of plant not less than 1.20m above ground level and of age 6 Months] with proportional girth, evergreen species including preparation of ground up to 0.45m deep and of size 450 X 450mm and filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. complete all as specified and as directed.
Supply, plantation and developing of Hedging [Crotons] of 300mm wide and 300mm height with hedge plants as approved by GE, evergreen species including preparation of ground up to 0.40m deep and of width 0.40m and filling of Good Earth [Without Moorum content] and having suitable pH and EC as recommended for Saline Water conditions [3 Parts], Manure such as Cow Dung, Vermi-Compost, Polydol Dust Neem Cake and Organic Manure etc. [1 Part] and watering etc. and applying Soil Pesticide, transplanting of Hedge Plants including cost of Good Earth, Manure, Pesticides, Hedge Plants etc. complete all as specified and as directed.
Note for Serial Item No. 14, 15, 16 & 17: [a] Good Earth shall be well sieved to pass 90% through IS sieve of 10mm size, free from stone rubbish like lumps, stones and other foreign materials suitable for gardening. The soil shall be fresh from quarry. The colour of soil generally be red and as directed by Engineer-in-Charge. [b] Manure shall be well decayed, well dried, well powdered, without clabs and free from stones, dried grass and rubbish materials. The colour of manure shall be black and shall be screened at site using IS designation 4.75 Sieve. [c] Rate quoted is deemed to be including the cost of Removal of excavated material [Soil] to a distance exceeding 250m and not exceeding 500 m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.
S & F 25mm dia Garden Sprinkler Valve Swivel type Brass Body, ISI marked, screwed both ends for iron pipe complete all as specified and as directed.
S & F Angle Cock, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterfly handle for iron pipe etc. complete all as per Jaquar Catalogue No. CON-059KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified and as directed.
S & F Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as per Jaquar Catalogue No. CON-011KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified and as directed.
S & F Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type, Short Body with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-047KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified and as directed.
S & F Health Faucet with 1 m long flexible tube, wall hook, non return valve complete as per Jaquar Catalogue No. ALD-CHR-585 or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified and as directed.
S & F Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as per Jaquar Catalogue No. CON-041KN or its equivalent in Marc / Kohler / Cera / Parryware / Grohe / Crabtree / Blue Star & Silver Shine complete all as specified.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Modular Type Pressed Metal Flush Box made out of 2mm thick GI Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified and as directed.
All as per Serial Item No. 24 above but for One Light Point controlled by Two Nos. of, Two way Switches complete all as specified and as directed.
All as per Serial Item No. 24 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 24 above but one 3 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
S & F Surface & wall mounted Energy efficient LED Tube Light Fitting, of not less than 1800 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Surface & wall mounted Energy efficient LED Round Light Fitting, of not less than 900 Lumens output, 5700 K of cool white, with extruded aluminium / CRCA housing and robust construction with necessary acrylic diffuser & integrated electronic driver, all accessories internally prewired and connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 2' X 2' Grid False Ceiling of not less than 3600 Lumens output, 5700 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient Sleek LED Mirror Light Fitting of not less than 500 Lumens, Surface / Recess mounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Energy efficient, Low Noise, Ceiling Fan, 1200mm Sweep, BEE 5 Star Rated, with BLDC Motor, Copper Wound, 350 RPM, with Double Ball Bearing, Conforming to IS - 373, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50Hz, of approved colour including Down Rod, Canopies, 3 Nos. Blades, Shackles, Safety Rope, Hanging Clamps, Bushes and having P.F >0.94, Service Value >6.5, Air Delivery >215 CMM, Power Consumption less than 35 Watt, THD less than 5% with speed control by Electronic Regulator including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F Exhaust Fan, 380mm Sweep, 1400 RPM, Metal Body, Heavy Duty, with Double Ball Bearing, Conforming to IS - 2312, ISI Marked, suitable for operation on Single Phase, 240 Volts, AC, 50 Hz, including Louvers Shutter / Grill, BEE 5 Star Rated and of approved colour including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed.
S & F MCB DB, TPN, 4 Way, 415 Volts, Vertical, with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed.
S & F MCB, SP, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, SPN, 6 to 32 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCB, TPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
S & F MCCB, FP, 125 Amps, 25 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 5 runs of 6 Sq.mm & one run of 32 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit
S & F Power Socket, 20 Amps with 2 Pole and Earth Plug & Socket for incorporating SP MCB complete including One MCB, SP, 20 Amps, B Curve, 240 Volts, 4 Modules, Modular Type Pressed Metal Flush Box and Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches & Sockets etc. complete all as specified and as directed.
S & F Energy efficient & Long life Building Security Light Luminaire, of not less than 3000 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S & F Wireless Call Bell system including One Number Push Button Transmitter and One Number Wireless Door Bell and necessary Batteries suitable for operating up to a distance of 50 Metres complete all as specified and as directed.
S & F Engaged & Free Light unit comprising of Two Nos. of PVC B22 Holder and 2 Nos. of 0.5 Watt LED Bulb of Colour Red & Green fixed in a Polycorbonate Cover Plate including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed.
S & F Heavy duty PVC Conduit, 25 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified
S & F Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drawing Coaxial TV Cable or Telephone Cable or LAN Cable etc. complete all as specified
S & F Telephone Socket / Jack with Shutter, RJ-11, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
S & F TV Socket / Outlet, Co-Axial, Deluxe, Modular Type, One Module including suitable Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet, Modular type Base / Grid Frame & Cover Frame complete all as specified and as directed.
Design, Manufacture, Supply, Installation, Testing and Commissioning of 11 kV / 0.433 kV, 400 kVA Factory Assembled, Factory Tested ready to install and connections type Compact Substation / Unitised Substation / Compact Substation with an outdoor enclosure, equipped with 400 kVA Cast Resin Dry type Transformer, 4 Way, 11 kV Ring Main Unit [SF6 Gas Insulated Switchgear] consisting of 2 Nos, 630A at 11 kV Fault Making Load Breaking Switch with mechanical interlock between Two Load Breaking Switches & 02 Nos Tee-Off as SF6 Gas insulated Vacuum Circuit Breaker and with 1600 Amps, Air Circuit Breaker as secondary side control complete with HT Cable interconnection in between Transformer and RMU and suitable sized Copper Busbar between Transformer and LV Incoming Main Switchgear-ACB for full load output current of the transformer and Internal earthing connections by GI Strips all as a single transport unit complete all as specified as detailed below: [a] Makes: Compact Sub-Station including Transformer and all HT & LT Switch Gears shall be of make BHEL / ABB / Siemens / Andrew Yule / Schneider / Crompton Greaves. Transformer and all HT & LT Switch Gears shall be same make as of Compact Sub-Station.
[b] Enclosure: Outdoor type enclosure having modular construction with 2mm thick Galvanized Sheet Steel in Corrugated / Louvered design type wall design for better heat dissipation and providing robust construction. The degree of protection for HT & LT switchgear compartment shall be IP54 & degree of protection of transformer compartment of the enclosure shall be minimum IP34. The enclosure exterior shall be painted with polyurethane paint / epoxy powder coated of 80 Microns thick and tropicalised to Indian weather conditions. Each compartment shall be provided with the door and pad locking arrangement. Doors of transformer compartment are fitted with Arc reflectors from the inside for providing better safety. The Compartment illumination lamp with door-operated switch shall be provided for each compartment. Structure of the substation shall be able to withstand the gross weight of all equipment. The Compact Substation shall be provided with lifting beams and hooks for easy installation at site and it shall be possible to transport the equipment along with Transformer, RMU & LT Panel from one site to another. Dimensions of enclosure shall be as per the components required and mentioned in BoQ. Final drawing shall be got approved from Accepting Officer. – 1 Nos.
[c] HT Switchgear [Inside Compact Sub-Station]: Four way 11KV, 630 Amps, 21 kA / 3 Sec Non-Extensible Ring Main Unit / Compact Switchgear with Copper Busbar, consisting of 630 Amps, Two Numbers [As incomer] fixed Manual Fault Making / Load Break Switches & Two Numbers Fixed Manual SF6 insulated Vacuum Circuit Breakers [As Outgoing] in SF6 Gas insulated sealed for life minimum 2mm thick AISI 441 Grade stainless steel tank with IP 67 degree of protection with Air Insulated Metering Module, castle lock interlock shall be provided between two incomers such way that only one incomer shall switch on at any given point of time, One Number fault passage indicator shall be provided for each Load Break Switch with 1 NO + 1 NC Contact, One Number manometer shall be provided for outgoing feeders, One set of 80/1A, 2.5 VA, Class 1.0 for metering & One set of 80 / 1A, 2.5 VA, CL 5P 10 Current Transformers shall be provided, One number of Digital Multifunction Meter with RS 485 Port shall be provided for VCB Feeders, One Set of 11 kV / RT3 / 110 / RT3, Class 1.0, 50 kVA PTs shall be provided in Metering Module. Vacuum Circuit Breakers shall be with self-powered micro processor based Numerial Over Current and Earth Fault Relay having Charged Open / Closing Mechanism, On / Off Indicators, Mechanical Operation Counters etc. Interconnection between RMU and Transformer shall be using suitable Aluminium unarmoured 11 KV [UE] 1 X 3 Core X 95 Sq.mm or 3 X 1 Core X 95 Sq.mm XLPE cable. Incomer / outgoing Load Break Switches shall be suitable for termination of 1 Run of 3 Core X 300 Sq.mm aluminium armoured XLPE Cable.
[d] Transformer [Inside Compact Sub-Station]: 400 KVA, 11KV / 433V, 3 Phase, 50 Hz, DYn11, Air Natural Cooling Cast Resin Dry Type, Double Copper Wound, CRGO Core type Transformer with Off Circuit Tap Links of range +5% to –5% in steps of 2.5% on HT side of transformer with WTI Scanner with Alarm and Trip Contact, with Class "F" Insulation, having Primary Voltage [HT] 11 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 11 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180 [Part - I] with latest amendments and with Energy Efficiency of "Level 2" – 1 Nos. Losses shall be as per ECBC.
[e] LV Switchgear [Inside Compact Sub-Station]: 415 Volts, indoor LV Panel with Aluminium Busbars [100% for Phase & 50% for neutral, fabricated using 2 mm thick CRCA Sheet Steel, Ingress Protection IP4X, Compartmentalised complete with internal wiring consisting of following: [i] Incomer: ACB, 630 Amps, FP, 50 KA, 415 Volts, 3 Phase, 50 Hz, Fixed Manual type with Microprocessor based O/L, S/C, E/F Release – 1 Nos [ii] Metering for Incomer: Digital Multifunction Meter with A, V, KW, KWH, PF, Class 1.0 with Port – 1 Nos, LT Metering CT’s, 630 / 1A, Cast Resin Type, Class - 0.5 – 1 Set, R, Y, B, ON, OFF, Trip LED Indicating Lamps – 1 Set, Control MCB, SP, 6 Amps – As required [iii] Outgoing: MCCB, 630 Amps, TPN, 50 KA, 415 Volts, 3P, 50 Hz, Fixed Manual type adjustable with Microprocessor based Thermal magnetic O/L, S/C & E/F release – 3 Nos. [iv] Metering for Outgoing: Digital Multifunction Meter with A, V, KW, KWH, PF, Class 0.5 with Port for each outgoing feeder, LT Metering CT’s, 600 / 1A, Cast Resin Type, Class - 0.5 – 1 Set, R, Y, B, ON, OFF, Trip LED Indicating Lamps – 1 Set, Control MCB, 6A, SP – As required [v] Outgoing MCCBs of LT Switchgear shall be suitable for termination of 2 Runs X 3½ Core X 300 Sq.mm aluminium armoured Cable. Qty - 6 Nos.
[f] Compact Substation shall be outdoor Plinth Mounted Type. The rate quoted is deemed to be including the cost of Erection, Commissioning of Compact Substation and Civil work such as Construction of foundation with Concrete / Brick masonry with plastering for the installation of Compact Substation of required size including trench for the cabling work etc. complete in all respect as directed by the GE. However the bidder shall furnish the foundation details for approval of GE before executing the work. [g] Compact Substation shall be complete with the internal interconnections & Earthing [GI] and extending of earth bar of Neutral and body terminals to the frame of the Compact Substation for connecting to the earth pits. [h] The bidder shall assemble the Compact substation at factory and no assembly of the same shall be allowed at site. Bidder shall be responsible for Installation & commissioning Compact substation. Technical data sheet of the Transformer, HV / LV Switchgear, Relay etc. shall be submitted to GE for approval before placing the supply order. [i] The equipments should be SCADA compatible in future by providing motor in future. [j] The bidder shall supply suitable & required no. of HT & LT Cable termination kits along with Compact Substation for HT & LT Cable terminations. [k] The Design for Internal Arc Fault shall be tested for 20KA for 1 Second as per IEC 1330/62271-202.
[l] Pre-Dispatch Inspection: Bidder shall offer for pre-dispatch inspection at OEM works. Only after the equipments are cleared by the department in writing, the bidder can dispatch the equipment. Routine tests shall be conducted and original test certificates shall be submitted at the time of Pre-Dispatch Inspection. [m] Commissioning Spares: Additional commissioning spares such as Digital Multifunction Meter – 1 Nos, Indication lamps – 3 Nos, Protection Relay – 1 Nos, Spring Charging Handles – 2 Nos and Panel Keys – 2 Nos shall be provided by the bidder. [n] Suppressors or other protection devices shall be provided, if required as per schedule of quantities, wherever the sub-station installation is likely to interfere during the operation with any other electric or electronic equipment. [o] All fittings, unit assemblies accessories, hardware foundation bolts, terminals blocks for connections, cable glands and miscellaneous materials and accessories of items of work which are useful and necessary for efficient assembly and working of the equipment shall be deemed to have been included within the scope of the work in the tender and within the overall details for complete item whether they have been specifically mentioned or not. [p] Supplying and fixing MV Danger Notice Plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. [q] Supplying and fixing HT Danger Notice Plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. 2 Each
Incoming: [a] MCCB, 400 Amps, 4 Pole, 36 KA with thermal magnetic release with rotary handle. [b] CBCT [c] Earth Leakage Relay [d] Over Voltage and Under Voltage Relay [e] Phase Indicating LED Lamps. [RYB] [f] Control Fuse Base with 2 Amps HRC Link [g] 6 Stage APFC Relay [h] Timer [i] Aux Contractor [j] Exhaust Fan
Outgoing: [a] [1 X 50 + 3 X 25 + 2 X 12.5] Capacitor Bank - 06 Nos [b] MCCB, 400 Amps, 4 Pole, 36 KA [c] Suitable KVAR MPP Heavy Duty Capacitor Cylinder Type, 415 Volts. [d] Suitable KVAR Capacitor duty contractor [e] Indicating LED Lamp. [ON/OFF] [f] Push Button. [Start/ Stop] [g] Control Fuse Base with 2 Amps HRC Link.
S & F Energy efficient & Long life Street Light Luminaire, of not less than 4500 Lumens output, 5700 K with Pressure Die Cast Aluminium Housing, IP66 protection, heat resistant glass cover, high power LEDs as light source, electronic driver including GI Bracket made out of 32 mm bore GI Tube, Medium Grade of size not exceeding 1.50 m in length and bent to shape required and fixed with 2 Nos of Pole fitting Clamps made out of MS Flat of size 50 X 6mm, bolts, nuts, washers and painting with two coats of aluminium paint over a coat of primer red oxide zinc chrome primer and connecting up with three core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm complete all as specified and as directed. Note: Light fitting shall be of PF>0.95
S & F Factory made FRP loop-in-loop-out box of size 250 X 200 X 105mm including MCB, SP, 6 Amps, B Curve, 240 Volts [1 Nos] and one number heavy duty Four Way Connector for incomer and outgoing cable, suitable for Pole mounting and fixed with clamps made out of 40 X 3mm flat iron with suitable nuts, bolts, gland lugs etc duly painted with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete of make Sintex or Hansu or Hensel or Schneider complete all as specified and as directed
S & F TimeLite Distribution Boards, TimeLite, 20 Amps, Single Pole, 230 Volts, Digital Time Switch, 24 Hours, with MCB, 32 Amps, TPN, Out door type, weather and vermin proof made out of 3.00mm thick CRCA Sheet duly painted with synthetic enamel paint with locking arrangement comprising of One Number Timer Switch, 24 Hours Operation, Accuracy: Quartz Time Base ±1 per day suitable for street light operation and duly fixed on pole with clamps / grouting on ground complete all as specified and as directed
M & L for Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including HDPE Pipe, 150mm bore, 0.4 Mpa working pressure complete all specified and as directed. Note: The horizontal directional drilling machine boring shall be minimum shot length of 100m horizontal length in a single span and depth shall not be less than 1.20m. The unit rate quoted is deemed to be inclusive for earth work as required at site for boring at starting and termination ends complete all as directed.
M & L for Cable Route Indicator made of CI disc 100mm dia, 6mm thick with inscription of HT Cable / 11000 Volts fixed to MS angle of size 40 X 40 X 6mm, 750mm long with bolts & nuts, duly grouted in PCC, 1:3:6, Type C1 complete including necessary excavation and earth work all as specified and as directed.
S & F Integral LED Aviation Light comprising of aluminium housing with polycarbonate enclosure including standard fixing arrangements and connecting up complete all as specified and as approved. Note: Light fitting shall be of PF>0.95
Supply, lay, test and commissioning of 3 Core, 2.50 Sq.mm, PVC Insulated and PVC sheathed, heavy duty cable, ISI marked with Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked including heavy duty PVC Conduit, 20 mm dia including all accessories, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
M & L for cutting the existing GI pipe line 80mm dia and inserting GI Tee of 80 X 80 X 80 mm for making new branch connecting of GI Pipe 80mm dia including necessary fittings, excavation, returning, filling and depositing excavated material to a distance not exceeding 50m complete all as specified and as directed
M & L for Construction of Valve Chamber of size 900 X 900 X 900 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified and shown on drawing CEDD / TD / 119, Sheet No. 1 / 1 dated 20 August 1983, revised up to 21 September 1992.
Supply, installation, testing and commissioning of Water Cooler of 40 Litres Cooling Capacity and 80 Litres Storage Capacity, Fully Stainless Steel, Electric driven, Single Phase, 230 Volts of make Voltas or Blue Star or Usha or Godrej complete all as specified and as directed
S & F Electronic wall mounted time delay Voltage stabilizer of 2 KVA Capacity, Automatic Operation, for input variation of 170 Volts to 250 Volts with stabilised voltage of 230 Volts with accuracy of ± 2.5% complete all as specified and as directed Make: V Guard / Servo / Kee Line
Supplying and laying 150 mm bore Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" with both side Flanged ends conforming to IS - 8329 in standard lengths with inside Cement Mortar Lining and Black Bitumen external coating and including necessary DI Specials as required complete all as specified and as directed.
Supply, installation, testing and commissioning of Fire Pump Diesel Engine driven, Horizontal end Suction, centrifugal type confirming to IS – 12469 with CI Casing, Bronze Impeller and Stainless Steel Shaft mounted on heavy duty bearings Suitable for continuous operation with Range of Operation 0 % to 150 % of rated capacity for 440 Volts, 3 Phase, 50 Hz AC Supply, 1800 RPM, 70m Head, 1620 LPM discharge with pressure of 3.5 KG / Sq.cm including 2 Nos of 12 Volts, 180 AH Batteries and PCC 1:2:4, Type B1 as in Foundation complete all as specified and as directed.
Supply, installation, testing and commissioning of Fire Pump Electrically driven, Horizontal end Suction, centrifugal type confirming to IS – 12469 with CI Casing, Bronze Impeller and Stainless Steel Shaft mounted on heavy duty bearings Suitable for continuous operation with Range of Operation 0 % to 150 % of rated capacity for 440 Volts, 3 Phase, 50 Hz AC Supply, 2900 RPM, 1620 LPM discharge at 70m Head, with pressure of 3.5 KG / Sq.cm including PCC 1:2:4, Type B1 as in Foundation complete all as specified and as directed.
Supply, installation, testing and commissioning of Jockey Pump, Horizontal end suction, Centrifugal type Confirming to IS – 12469 with CI Casing, Bronze Impeller and Stainless Steel Shaft mounted on heavy duty bearings suitable for automatic operation with non–over loading power characteristics for frequent Start / Stop operations suitable for 440 Volts, 3 Phase, 50 Hz, AC Supply, 180 LPM Discharge at 70 m Head with pressure of 7.0 KG / Sq.cm complete all as specified and as directed.
Supply, installation, testing and commissioning of Booster Pumps for 440 Volts, 3 Phase, 50 Hz confirming to IS – 12469 with CI Casing, Bronze impeller and Stainless Steel Shaft mounted on heavy duty bearings suitable for 30m Head, 900 LPM discharge with pressure of 2.0 KG / Sq.cm complete all as specified and as directed.
S & F Foot Valve, Cast Iron Body, 150mm bore with Flanged ends of any pattern with Bypass Arrangement and Confirming to IS – 4038, ISI Marked including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
S & F Foot Valve, Cast Iron Body, 80mm bore with Flanged ends of any pattern with Bypass Arrangement and Confirming to IS – 4038, ISI Marked including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
Supply, lay, test and commissioning of 2 Core, 1.50 Sq.mm, Armoured Multistranded Copper Conductor Cable, 1100 Volts, FRLS Grade, conforming to IS - 1554 and ISI Marked including heavy duty PVC Conduit, 20 mm dia including all accessories, laying in walls / roof / false ceiling / floor / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
S & F Fire Extinguisher CO2, of Capacity 3 KGs, ISI Marked complete all as specified and as directed.
S & F Fire Extinguisher ABC type, of Capacity 4 KGs, ISI Marked complete all as specified and as directed.
Supply Install Test and commissioning of Silent Diesel Engine driven Generating Set of Capacity 40 KVA / 32 KW, 415 Volts, Three Phase, 4 Wire, Engine as per IS – 10001 / 10002 and Alternator as per IS – 13364 complete with relay panel for automatic starting on main failure, control panel having meters, sound proof canopy as per relevant IS and foundation etc. including following: [Make: Kirloskar Green / Cummins / Ashok Leyland / Greaves Cotton] A. ENGINE: Direct Injection, Water / Air Cooled Engine, 2 Cylinder, in-line, 4 Stroke, rated at 1500 RPM, conforming to BS – 5514 and having following specifications: [i] In- line fuel pump with Electronic Governor for 40 KVA. [ii] Turbocharger [iii] Stainless Steel Exhaust Flexible Coupling and Exhaust Pipe duly insulated with Glass Fire Wool and Plain GI Sheet Cladding & extended outside the building. [iv] Silencer [v] Radiator [vi] Coolant Inhibitor [vii] Plate type Lub Oil Cooler [viii] Spin-On-Filters-Coolant, Fuel, Fuel & Lub Oil [ix] Dry type, Heavy Duty, Replaceable Paper Element Air Cleaner with Restriction Indicator [x] Flywheel Housing and Flywheel to suit Single Bearing Alternator [xi] Electrical Starter Motor [xii] Battery Charging Alternator [xiii] 1x12 Volts Batteries, 88 AH Capacity with multistranded copper cable for connecting leads and terminals [xiv] First fill of Lub Oil.
B. ALTERNATOR: [i] Self Excited & Self Regulated [ii] Voltage Regulation ± 1 % [iii] Class H Insulation [iv] Salient Pole Revolving Field [v] Digital Automatic Voltage Regulator [Part of PCC 1301] [vi] Standard Enclosure IP-23 [vii] Telephone Interference Factor: 50 [viii] Total Harmonic Factor: Better than 2% [ix] Supplying power to variable electrical load for unlimited hours. Prime power [PRP] is in accordance with ISO 8528. 10% over load capacity for one hour every 12 Hours of operation and will be suitable for tropical condition.
D. FUEL TANK: [i] Fuel Tank of suitable capacity for minimum 12 Hours run with provision for Supply and Return Lines, Level Indicator, Drain Valve, Cleaning Cover Vent Pipe & Locking Device. [ii] MS Fuel Pipeline from Fuel Tank to FIP of suitable size. [iii] Fuel Tank shall be mounted / located outside the cubicle with suitable mounting with angle iron supports. E. ACOUSTIC ENCLOSURE: [i] Designed to meet stringent MOEF / CPCB norms 75 dBA @ 1 m at 75% load under free field conditions. [ii] Air Inlet Louvers shall be designed to operate at rated load even at 50°C Air Inlet Temperature. [iii] Cubicle shall be powder coated for long lasting service life and super finish with UV Resistant Powder Coating and shall withstand extreme environment. Stain Steel hardware shall be used. [iv] Insulation Material shall meet / conform to IS – 8183 Specifications for better sound attenuation [v] Provision of Genset Controller for Engine & Alternator. F. ACCESSORIES: [i] Periodical Maintenance Tools as per Manufacture [ii] Operational, Spare Parts, & Installation Guidelines and Catalogue.
NOTE: Rate quoted is also deemed to be including the following: [i] Provision of 200mm thick PCC 1:1½:3, Type A1, using 20mm graded stone aggregate Foundation over 200mm thick PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 200mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick complete as per manufacturer's instructions with Anti-Vibration Mounting Pads as per manufacturer’s guidelines including necessary earthwork excavation, return filling, removal surplus soil and applying two coats of Cement Based paint over a coat of Alkali Resistant Primer complete etc. complete all as directed. [ii] Testing of DG Set shall be carried out by the IEM in presence of the OEM Representative. [iii] Artificial load i.e. strip heaters of suitable capacity and Diesel required for testing shall be made available during test by the contractor. [iv] Extended terminals with tinned copper has to be provided for terminating the incoming & out going cable with suitable lugs for ACB’s / MCCB's if required. [v] U/G cable shall be laid / connected to DG Set Cubicle Panel to AMF Control Panel [Changeover Panel] all as specified and as directed [vi] Provision of cable gland & Aluminium lugs of suitable size for terminating the cable at both ends.
Supply, install, testing & commissioning passengers lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 HZ supply confirming to IS - 14665, suitable to serve 13 Passengers [884 KGs] 5 Floors i.e. G + 4 upper floors with AC VVVF drive regenerative type [closed loop] & automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive [electric motor driven mechanism], sliding stainless steel doors, with moon rock finish of 16 gauge with view glass panel automatic rescue device [ARD] system, 3D infra red sensor in full height of door & built in announcing system without hand set [04 Nos., one each in Car, Machine room & near Ground floor landing door] complete all as specified Inclusive Equipment / Machinery Earthing of GI Plate 600x600x6mm by using aluminium strip 32x6 of size as per SSR specifications up to Earth pit & Equipment. Dimension of lift well and distance between floor to floor shall be all as shown on drawings. Note: The lift shall be provided with and including the following: [a] Fireman Switch [b] Automatic rescue device during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. [c] Battery operated emergency light [CFL Ceiling Fitting] alarm [speaker for emergency alarm system to be fixed] and stop button in car with reachable arrangement for battery. [d] Suitable Nos LED light fitting in false ceiling [e] One Sleek Circular, Heavy Duty Fan shall be fixed in the ceiling.
[e] Provision of false ceiling with 7 watt LED lights and 12mm [minimum] granite flooring for lift car over suitable thickness of aluminium chequered sheet. [f] Nonstop button/independent operation. [g] Over load warning indicator visual type [h] Front landing door of stainless steel moon rock finish, operations with a minimum time of 10 sec and up to a maximum time of 30 seconds. [i] Car size shall be in conformity with IS 14665 and body to be stainless steel of 16 gauge moon rock finish with stainless steel hand rail. [j] Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. [k] Stainless steel hand rail 38mm hairline finish. [l] Specification plate [m] Continuous earthing for machine and equipment [n] Wire rope of adequate size as per relevant IS and as per manufacturers specification. [o] Other standard fixtures and fittings like rails, sheaves, counter weights with guards, buffers, gear unit, brackets, control panel, power control and trailing cables complete all as per latest IS specifications. [p] Lift design, specifications, drawings, manufacturers instructions shall be got approval from Accepting Officer before placing order for procurement. [q] Car Door & Landing Door opening in Moon rock finish [16 Gauge thick] with vision panel of size 200 X 1200mm with toughened glass of 8mm thick.
PHASE – II [Schedule "A" Part – XV]: Maintenance of Arboriculture Works during Defect Liability Period [i.e. 24 Months],
Maintenance of Arboriculture / Plants / Grass as provided under Serial Item No. 14, 15, 16 & 17 of BoQ by weeding, hosing, saucer melding once in every 15 days, planting new Plants / Grass in place of dead Plants / Grass of same species and height without any extra cost to the department and as directed complete during Defect Liability Period complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading / spraying organic manure, chemical fertilisers, pesticides to the required extent complete all as specified and as directed.
PHASE – III [Schedule "A" Part – XVI]: Comprehensive Maintenance of Passenger Lift as Provided Under This Contract as per Serial Item No. 81 of This BoQ/Schedule "A" Part – XIV for Three Years After Successful Completion of Defect Liability Period of Work under Phase – I]:
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 13 Passengers [884 KGs] Capacity, serving G+4 Floors, all as specified under Serial Item No. 52 of BoQ / Schedule "A" for First Year after expiry of Defects Liability Period complete and all as specified in Particular Specifications and as directed by Engineer-in-Charge.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 13 Passengers [884 KGs] Capacity, serving G+4 Floors, all as specified under Serial Item No. 52 of BoQ / Schedule "A" for Second Year after expiry of Defects Liability Period complete and all as specified in Particular Specifications and as directed by Engineer-in-Charge.
M & L for Comprehensive Maintenance of Electrically Operated Passenger Lifts of 13 Passengers [884 KGs] Capacity, serving G+4 Floors, all as specified under Serial Item No. 52 of BoQ / Schedule "A" for Third Year after expiry of Defects Liability Period complete and all as specified in Particular Specifications and as directed by Engineer-in-Charge.
[e] The rate quoted shall be deemed to be inclusive of testing of each lift by Licensed Lift Inspector of Government of Andhra Pradesh once in Contract Period for worthiness of the Lift in respect of safety. Certificate issued by the Licensed Lift Inspector shall be submitted to the Engineer-in-Charge and a copy of Certificate shall be displayed in all Lift Cabins as directed by Engineer-in-Charge. [f] Emergency Light and necessary tools shall be available in a tool box in the shift for smooth functioning of lifts. [g] Conveyance and communication system like mobile phone etc. shall be provided by the contractor to all Lift Mechanics and Helpers. [h] The contractor shall abide by the latest Labour Rules and Minimum Wages Act.
[i] Wages paid by the contractor to the persons employed shall not be less than the minimum wages fixed by State / Central Government from time to time whichever is higher. The contractor shall also insure the workmen employed on the job. [j] The contractor is responsible for Insurance, EPF, ESI, Gratuity, Bonus, Labour Welfare Cess etc., as applicable and shall be paid to the Workmen as per existing Labour Rules / Acts / Regulations and rate quoted shall be deemed to be included for the same. [k] INSURANCE AND DRESS CODE: The contractor shall provide the workmen with Dark Blue Colour uniform with labels showing the Name of Firm and the Designation and "GE [U-II] [V]" printed on them along with protective clothing. The contractor shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. [l] The contractor shall be responsible for all Accidents / Injuries happening to the workmen. Any accident causing Minor / Fatal Injury, Partial Disability due to any untoward incident or non-adherence to Safety and IE Regulations or fault in maintaining of Lifts System / Safety Mechanism or on account of any mishandling / wrong operation / lack of knowledge of safety precautions or on account of any circumstances beyond his/their control, the contractor shall be solely responsible for settling all claims of compensation to the deceased, failing which department will have a right to recover any sum indicated / claimed by Labour Commissioner / Court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Contractor shall provide first aid boxes to meet any emergency situations.
[m] The contractor shall carryout the comprehensive maintenance of the lifts catered under subject work through the Original Equipment Manufacturer of that lift or from their accredited / authorised agencies only. The lowest bidder shall submit MoU from the Original Equipment Manufacturer of the Lift or from their accredited / authorised agencies to provide technical support, trained persons for maintenance & testing and spares before commencement of the work to GE. The spares shall be of the make as per existing or as per the OEM. [n] MINIMUM MANPOWER TO BE EMPLOYED: The contractor shall be required to employ the One Lift Mechanic per Shift of 08 Hours from 0900 Hours to 1700 Hours and shall report to Office of AGE [E/M] for day to day maintenance and efficient operation of Lifts:
P NAIDU
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .