Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹45.6 L+₹1.4 L (3.09%)Rejected-Finance HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | L2 | Rejected-Finance Being not L1. | |
| 3 | L3₹46.4 L+₹2.2 L (4.93%)Rejected-Finance | L3 | Rejected-Finance Being not L1. |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MC Chandigarh
GE (AF) MC Chandigarh
REPAIR TO SOUND INSULATION, ACOUSTIC DOOR IN ETH AT BRD UNDER GE (AF) MC CHANDIGARH
2021_MES_496467_1
GE (AF) MC /CHD-71/2021-2022
Open Tender
Civil Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹96,000
Yes
10 Feb 2022
21 Dec 2021
26 Jan 2022
21 Dec 2021
24 Jan 2022
10 Jan 2022
60 days
Amount
SOUND PANELS FOR ACHIEVING 80 DB OUTSIDE THE TEST ROOM (a) M & L for providing and fixing in position acoustical insulation fixed tightly with studs clips at regular intervals @ 600 c/c on walls/ ceilings/columns/beams etc consisting of 100mm thick fire resistant sound absorptive material ( Resin bonded rock slab of density above 90 Kg/Cum lining in 600 x 600mm panels covered with protective layer of tissue fixed to 22 gauge thick GI frame work ( channel )sections of size 25mm x 50m x 50mm x 25mm @ 600mm c/c verticals members and 1200 c/c horizontal members ) fixed to walls /ceiling/column/beams etc by means of raw plugs/fasteners etc , including all incidental works, tools, tackles etc complete all complete all as specified and directed. (b) providing and fixing of 0.6mm thick powder coated perforated metal liner panel 600mm wide and 25mm depth over acoustic insulation pads, panels, to be erected on clip profile with ribs of panels running vertically, sub grits to be installed horizontally at 1200mm maximum, vertical spacing attached to ribs of interior wall panel with fasteners, including all incidental work, tools, tackles etc the complete assembly to installed at high height in exiting Room complete all as specified and directed. Make of Rockwool :- Roxul-Rockwool (Safe 'n' silent Pro 370) Make of CRCA sheet and perforated steel sheet :- SAIL/TATA
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete and including taking down old plaster complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement and including taking down old plaster complete all as specified and directed.
M&L for preparation of new plastered/concrete surfaces of walls and applying two coats of oil bound distemper over one coat of primer, over 1mm thick birla white putty ( where as required ) white or tinted including necessary scaffolding etc complete all as specified and directed.
M & L for preparation of new plaster suface applying two coat of cement base paint including a base coat of primer surface finished complete all as specified and directed.
Taking down chowkhat or frame exc 1.5 sqm but n.exc 4 sqm each without taking off shutter from the frame complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but exluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for Brick work with fly ash bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and directed.
Material & labour for providing and fixing 65mm thick acoustical doors for the Observation and control room having chowkhat on all the four sides of size 125mmx79mm of 1st class Teakwood. The door is to be fabricated using 100mm x 74mm thick teakwood frame and 12mm MDF board veneer facing and finished with varnish on both side. The door will have insulation with one layer of 30mm th. 96 kg. Cum density rockwool with sound deadening membrane with 1 layer of high density 8 mm thick having density 1300 kg/m3 in one side. The rockwool should be supported with wooden batten of Kail wood frame work minimum 610mm X 610mm to avoid sagging complete all as per manufactureres instructions specified and as directed. (Make of specilized firm:- Earcons/ Hera Design/ Prolad/Himalayan)
Note: 1. Necessary drg for the item of work will be prepared by the contractor and approval will be obtained from GE prior to the execution of work and cost for preparation of drg shall be deemed to be included under quoted rate of item and nothing extra will be admissible on this account. 2. The door will have hydraulic door closer, cross bar door handle and relevant hardware for fabrication and fixing. The door seal shall be of rubber Magnetic type and shall be provided all around. The door is to be attached with door frame with door frame with brass metal hinges having adequate strength to avoid sagging all joints to be sealed with mastic sealant. Handles are to be provided on each leaf of the door. The doors on the auditorim side to be finished using non-light reflective media like carpet of dull laminate/ veneer complete all as per manufacturer's instructions and as directed. (3) Door shall be single leaf side hung or double leaf side hung door depending upon the requirement of ground and size of door opening shall be measured for payment. (4) 02 Nos brass tower bolt 300mm long and 02 Nos brass sliding door bolts 300mm included in quoted rates.
M & L for providing and fixing 12mm and 10mm two laminated bullet proof glass fixed with 25mm air gap in exiting frame using silicon on all the corners along with gasket for complete isolation ,complete all as specified and directed.
M & L for providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc , including welding, grinding, buffing, polishing and making curvature ( where required ) and fitting the same with necessary stainless steel nuts and bolts complete fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc of required size on the top of the floor or the side of waist slab with suitable arrangement complete all as per manufactures’ instructions and complete all as specified and directed.
M&L for 6mm thick Epoxy PU flooring complete all as specified and directed and as per manufacturer's instruction consisting of following steps/Stages. MAKE: CIPY/SIKA/BASF/APURVA/ASIAN (i) SURFACE CLEANING: cleaning of surface free from dust, dirt, moisture & foreign material from the floor by grinding and scrubbing. (ii) M & L for Epoxy polyurethane floor coating consisting of 200 micron thick priming coat, 3800 microns screed coat and 2000 micron thick top coat including necessary preparation of the existing surface all as per the manufacturer’s instructions complete all as specified and as directed . (iii) forming joints 8mm to 40mm average width and 20mm average deep with closed cell polyethylene backup rod of required dia more than width of joint and top 12mm depth primed and sealed with polyurethane based sealing compound including applying masking tape on edges of joints to prevent accidental spillage of sealant and removing the masking tape by mechanical means after application of sealant including cutting out the exiting joints up to the required width /depth using diamond cutter , removing the debris and other foreign materials to a distance exceeding 1.5KM and not exceeding 5.0KM and depositing where directed and cleaning the sides and bottom of joints by using compressed air complete all as specified and as directed.
M & L for 6mm aromatic PU coating over primer , with PU marking paint approved as per manufacturer’s instructions/specifications as in line, dashes, arrows, letters, width or girth exceeding 10cm, marking in yellow/white/red/orange colour as approved by GE complete all as specified and directed.
Taking down carefully of flame proof/normal point wiring (Light, fan, socket or power complete (fittings such as switches, ceiling roses, pendants, regulator, sockets etc) removing from site of work and making good to the disturbed surfaces of walls/floors etc complete all as specified and directed
Taking down ceiling fan after disconnecting electric connection carefully and deposited to MES Store -01 No and for reuse (06Nos) including down rod 24" long complete all as specified and directed.
Taking down valve pull box, fire alarm panel and push button box after disconnecting all the connection carefully and kept at site for re-fixing at designated location complete all as specified and directed.
Taking down pressure indicator after disconnecting all connection carefully and kept at site for re-fixing at designated location complete all as specified and directed.
Taking down carefully ceiling light/flameproof tube light fitting of any wattage and kept at site for re-fixing at designated location complete all as specified and directed.
Material and labour for flame proof point wiring complete with 1.5 sqmm PVC insulated FRLS copper conductor including stove enamelled steel conduits on surface including all flameproof accessories like bends, tees, nipple, junction box, sockets etc and including 1.5 sqmm PVC insulated FRLS copper conductor used as earth wire including making good to the disturbed surface to match with the existing complete all as specified and directed for one light point.
All as per item No 19.00 above but with 2.5 sqmm copper conductor cable complete all as specified for one flameproof socket outlet 16 Amp independent.
M&L for Refixing of flame proof tube light fitting including making connection complete all as specified and directed.
M&L for Refixing of flame proof socket single phase including making connection complete all as specified and directed.
M&L for Refixing of flame proof rotary switch single phase including making connection complete all as specified and directed.
Supply & Fix in repairs flame proof SPN DB 8 way with metal door IP 54 protection fixed MCB SPN 32 Amps 01 No and MCB SP 6 to 32 Amp 06 Nos as per sudhir make complete on pillars with MS clamps etc including electric connections complete all as specified and directed.
Dismantling/taking down carefully split AC of any capacity after disconnecting all the connection and kept at site for refixing complete all as specified and directed.
Refixing of split AC retrieved from item No 25 above including making all connection complete at designated location all as specified and directed.
S&F in repair Sheet metal enclosure with socket plug top and MCB Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
S&F in repair flame proof weather proof ceiling fan 1200 mm sweep with regulator single phase in cast aluminium LM-6 complete all as specified and directed.
Material and labour for point wiring in and including rigid PVC non metallic rigid conduit medium duty of suitable size as per site reqmt including cutting chases for sinking for flush boxes and wiring with 1.5 sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable in and including flush type metal boxes modular type suitable for fixing modular switches, sockets, fan regulators etc with brass screw, cup washer and including PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm as earth wire connected to common earth and earth dolly as per IS specification and as specified for the One light/fan/bell point controlled by one switch complete all as specified and directed..
All as per item No 29 above but for one 3 pin socket outlet 6 Amp on independant board
All as per item No 29 above but with 2.5 sqmm copper conductor cable for one 3 pin socket outlet 16 Amp on independent board
S&F switch modular, 1 module single pole one way 6 Amp complete all as specified and directed.
S&F modular socket outlet 6 Amp , 2 module complete all as specified and directed.
S&F switch modular, 1 module single pole one way 16 Amp complete all as specified and directed.
S&F socket outlet modular 6/16 Amp multipurpose , 2 module complete all as specified and directed.
Supply and fix ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
Taking down LED slim flat panel 36 watt complete all as specified and directed.
S&F in repair LED slim flat panel 36 watt having lumen output more than 3200 lumens suitable for false ceiling of cut out size 2'x2' including making connection complete all as specified and directed.
Refixing of LED slim flat panel 36 watt inlcuding making connection complete all as specified and directed.
Taking down carefully after disconnecting all the electric connections of socket 1 phase/3 phase 28 volts, 36 volts, 115 volts & 230 volts complete with box and kept at site for refixing at designated location all as directed.
Taking down carefully submain wiring single core of size 2.5 sqmm complete all as specified and directed.
Taking down carefully submain wiring single core of size 4 sqmm complete all as specified and directed.
Taking down carefully submain wiring single core of size 16 sqmm complete all as specified and directed.
Refixing of submain wiring single core of size 2.5 sqmm (two run) and 1.5 sqmm (one run) in and including PVC cable tray of size 80mm x 50 mm complete all as specified and directed.
Refixing of submain wiring single core of size 4 sqmm (two run) and 2.5 sqmm (one run) in and including PVC cable tray of size 80mm x 50 mm complete all as specified and directed.
Refixing of submain wiring single core of size 16 sqmm (two run) and 10 sqmm (one run) in and including PVC cable tray of size 80mm x 50 mm complete all as specified and directed.
M & L for Wiring for circuit/submain wiring alongwith earth wire with 2x2.5 sq. mm + 1x 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable on surface as required including PVC cable tray of size 80mm x 50 mm with all accessories like bends, tees, nipple including making good to the disturbed surface to match with the existing complete all as specified and directed.
M & L for Wiring for circuit/submain wiring alongwith earth wire with 2 x 4 sq. mm + 1 x 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface as required including PVC cable tray of size 80mm x 50 mmwith all accessories like bends, tees, nipple including making good to the disturbed surface to match with the existing complete all as specified and directed.
M & L for Wiring for circuit/submain wiring alongwith earth wire with 4 x 16 sq. mm + 2 x 10 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable on surface as required including PVC cable tray of size 80mm x 50 mm with all accessories like bends, tees, nipple including making good to the disturbed surface to match with the existing complete all as specified and directed.
Taking down carefully CO2 nozzle of any size or make and refixing the same after extending the point by using MS pipe of 20/25mm of same make and fitting such as MS socket, bend, nipple complete all as specified and directed.
Taking down carefully smoke detector any type or make and refixing the same at designated location complete all as specified and directed.
Supply & laying in repairs of PVC insulated FR copper conductor 1.5 sqmm 2 core multistranded flexible cable drawing in existing steel conduit complete all as specified and directed. Make : Finolex/Plaza/Havells
Taking down carefully after disconnecting all the electric connections of MCCB Panel and refixing the same at designated location including making all connection complete all as specified and directed
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI wire 4 mm dia as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 15 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc including dismantling old earthing, complete all as directed and specified. Note : The earth value/result must be less than 5 ohms.
Note:- (i) The tenderer are advice to visit the site before quoting their rates with prior approval of Engineer-in-Charge i.e. AGE B&R and AGE E/M. (ii) The liability of contractor that all the repaired/serviced equipments should be made functional for 2 years from date of commencement. (iii) Please note that all the above activity included in quoted rates by the tenderer.
Note:- Amount of credit of Rs. 15395.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
His Construction Company
Bharat Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .