Loading…
Loading…
Tender Value
₹27.3 L
EMD Value
₹54,600
Closing Date
29 Sept 2026, 11:00 am2d left
EXECUTIVE ENGINEER
ELECTRICAL DIVISION HPPWD PALAMPUR
Sh Providing installation , testing and commissioning of addressable fire alarm and PA system therein).
2026_PWD_144077_2
Electrical Division HPPWD Palampur
Open Tender
Electrical Works
Percentage
Bhanjraru
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
₹54,600
23 Sept 2026
23 Sept 2026
29 Sept 2026
23 Sept 2026
29 Sept 2026
23 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable Main Fire Alarm Control Panel with 2 Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Ouputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have seamless integration with EVAC certified Public Address System and shall be complete with all accessories, UL-FM/EN54-VDS Listed Certification.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST. | 1 | Each | 2,12,153 | ₹2,12,153 |
| 1.01 | Make: Schrack Honeywell (Notifire) / JC/IFC Series | - | - | - | - |
| 2 | Supply, Installation, Testing and Commissioning of Active and networkable repeater panel with 4x20 character LCD display complete system function keys for programming and control like system reset, alarm acknowledgement, alarm silence, trouble acknowledgement etc. Shall be UL-FM/EN54-VDS Listed Certification.The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST. | 1 | Each | 97,362 | ₹97,362 |
| 2.01 | Make: Schrack Honeywell (Notifire) / JC/IFC Series | - | - | - | - |
| 3 | Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL-FM/EN54-VDS Listed Certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) . The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST. | 188 | Each | 3,123 | ₹5,87,124 |
| 3.01 | Make: Schrack Honeywell (Notifire) / JC/IFC Series | - | - | - | - |
| 4 | Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL-FM/EN54-VDS Listed Certification.. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) . The rate is including octroi, royality, malkana toll tax and other taxes imposed by the Government but excluding GST. | 5 | Each | 2,867 | ₹14,335 |
| 4.01 | Make: Schrack Honeywell (Notifire) / JC/IFC Series | - | - | - | - |
| 5 | Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL-FM/EN54-VDS Listed Certification. | 11 | Each | 3,881 | ₹42,691 |
| 5.01 | Make: Schrack Honeywell (Notifire) / JC/IFC Series | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
FireChamba.pdf
Tender Documents • 3.87 MB
BOQ_214243.xls
BOQ • 0.32 MB
DECLARATION.pdf
Additional Documents • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .