Shri S.S. Bhattacharyya
Dy. general Manager (E/M), Contracts and Procurement, Kameng Hydro Electric Project, NEEPCO, Kimi, West Kameng, Arunachal Pradesh
Maintenance of 132/33 kV Transmission Lines and Operation and Maintenance of indoor sub-station of Kameng HEP, NEEPCO, Kimi, Arunachal pradesh
2021_NEEPC_84461_1
KaHEP/EMG/08
Open Tender
AMC/ Maintenance Contracts
Tender cum Auction
1095 days
Kameng Hydro Electric Project, NEEPCO, Kimi, Aruna
As per bid document
2 documents required · 2 mandatory
₹10,000
Yes
Kameng Hydro Electric Project
Exempted
9 Mar 2022
10 Aug 2021
14 Sept 2021
10 Aug 2021
13 Sept 2021
11 Aug 2021
11 Aug 2021 - 29 Aug 2021
Amount
MAINTENANCE OF 132 & 33 KV TRANSMISSION LINES
Maintenance of 132 KV S/C transmission line (Charged at 33 KV) from Khuppi 132/33 kv sub-station to Kimi 33/11 kv sub-station. Line Length: 7 km approx. (Support structures: Lattice type structures, Conductor: 3ph-4wire, ACSR Panther, Configuration: triangular). (This scope of work may be reduced from the date of taking over of the transmission line by Deptt. of Power, Govt. of Arunachal Pradesh. As such, this scope will be under reduced scope as and when required basis)
Maintenance of 33 KV S/C sub-transmission line from Khuppi 132/33 kv sub-station to Tenga Dam site 33/11 kv sub-station. 4 km approx. (Support structures: Tubular steel poles, Conductor: 3ph-3wire, ACSR Dog, Configuration: Horizontal/Triangular).
Operation and Maintenance of Construction Power at Kameng HEP : Bichom Sub-group
2x2.5 MVA 33/11 kv Bichom S/S
33/11 kv Indoor S/S and associated equipment at Bichom: Equipment under maintenance: 2 Nos. 2.5 MVA, 3-ph 33/11 kV Bichom Indoor Sub-station: 1 No. 125 KVA, 11/.4 kV SST, 4 Nos. 33 kV indoor Breaker Panels (With 36 kV SF6 CB, LA etc.), 12 Nos. 11kV Indoor Breaker Panels (With 12kV VCB, LA etc.), associated Controls & Relay Panels, Power & Control cable & other associated equipment/materials.
33 kV S/C Pole mounted Transmission Line from 33/11 kv Tenga Dam indoor sub-station to 33/11 kv Bichom indoor sub-station. Length 16 km approx. (Support structures: Tubular steel poles, Conductor: 3ph-3wire, ACSR Dog, Configuration: Horizontal/Triangular).
Equipment under maintenance at Bichom: 1 No. 1 MVA, 3-ph 11/0.4 kV transformer and 2 Nos. 630 KVA 11/0.4 kV transformers at Bichom including the GOAB arrangements and LA etc. power & control cable & other associated equipment/materials.
Operation and Maintenance of Construction Power at Kameng HEP: Tenga Dam Sub-group (this work will be under reduced scope as and when required
2x2.5 MVA 33/11 kv Tenga Dam S/S
33/11 kv Indoor S/S and associated equipment at Tenga Dam site: Equipment under maintenance: 2 Nos. 2.5 MVA, 3ph 33/11kV transformers, 1 No. 125 KVA, 11/0.4 kV SST, 4 Nos. 33kV indoor Breaker Panels (with 36 kV SF6 CB, LA etc.), 12 Nos. 11kV Indoor Breaker Panels (with 12 kV VCB, LA etc.), associated Control & Relay Panels, Power & Control cable & other associated equipment/materials.
11 kV S/C sub-transmission Lines from 33/11 kv Tenga Dam Indoor S/S to different load centers: Length: Total 0.5 kms. approx. (2 nos. of feeders). (Support structures: Tubular steel poles, Conductor: 3ph-3wire, ACSR Rabbit, Configuration: Horizontal/Triangular).
2 Nos. 630 KVA, 3-ph 11/0.4 kV transformers at Tenga Dam site including the GOAB/DO arrangements and LA etc. Power & control cable & other associated equipment/materials
Operation and Maintenance of Construction Power at Kameng HEP: Kimi Sub-group
2x2.5 MVA 33/11 kv Kimi S/S
33/11 kv Indoor S/S and associated equipment at Kimi: Equipment under maintenance: 2 Nos. 2.5 MVA, 3ph 33/11kV transformers, 1 No. 125 KVA, 11/0.4 kV SST, 4 Nos. 33kV indoor Breaker Panels (with 36kV SF6 CB, LA etc.), 12 Nos. 11kV Indoor Breaker Panels (with 12kV VCB, LA etc.), associated Control & Relay Panels, Power & Control cable & other associated equipment/materials.
11 kv S/C sub-transmission lines from 33/11 kv Kimi Indoor S/S to different load centers: Length total 8 km approx. (3 nos. feeders). (Support structures: Tubular steel poles, Conductor: 3ph-3wire, ACSR Dog/Rabbit, Configuration: Horizontal/Triangular).
Equipment under maintenance at Kimi: 2 nos. 1 MVA 3-ph 11/0.4 kV Transformer & 4 nos. 630 kVA 11/0.433 kV Transformers at Kimi and 1 no. 630 kva 33/0.4 kv transformer at Kimi including the GOAB arrangements and LA etc., power & control cable & other associated equipment/materials
Bidder Name
Amount in Words
mega electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .