Tender Value
₹2.7 Cr
EMD Value
₹5.3 L
Closing Date
24 Apr 2026, 12:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SRDEEG/SEE
16 conditions · 5 needing a document upload
Contractor should have to be registered with Employee Provident Fund Organization (EPFO). It is mandatory for contractor to submit PF code provided by EPFO with their tender offer. Also each contractor has to submit "UAN" of their worker with their offer and have to mention in tender document. It is mandatory. Otherwise offer will not be considered for further action and your offer will summarily be rejected.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of 'V/N'or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
As per CE/Works/HJP's letter no. ECR-HQ0ENGG(CONT)/0009/2025, dated 18.11.2025 "The balance sheet and all other financial documents attested/certified by the Chartered Accountant (CA) to substantiate fulfillment of Financial Eligibility Criteria should be with UDIN, failing which the offer shall be considered as incomplete and will be summarily rejected without any further reference."
The tenderer shall posses the valid Electrical Contractor's license and Supervisory License issued by any State/Central Govt. licensing board for the required voltage level or above with their tender paper. Tenders without valid electrical contractor's license & Supervisory license will summarily be rejected.
"ELIGIBILITY CRITERIA:- Document required to be submitted in support of Technical Eligibility Criteria: Tenderer should have completed at least one similar single work. The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar nature of works (as defined and approved by competent authority) for "At SEE Divn.:- Provision of 70-30% automatic lighting arrangement on platform of stations in SEE Division" is "Supply erection testing and commissioning of 30% & 70% lighting system by signaling sensoring & automatic load controller unit."
27 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderers whether sole proprietor , a limited company or a partnership firm he/they should submit authentic proof in terms of partnership deed, proprietorship documents etc. along with the tender. If he/they want to act through agent or individual partners should submit a power of attorney duly stamped and authenticated by Notary Public or by Magistrate in favour of specific person whether he/she/they are partners of the firm or any other person specifically authorizing him/her name to submit the tender, sign the agreement , receive money, witness measurements, sign measurement books , compromise, settie, relinquish any claims, preferred by firm and also sign No Claim Certificate and refer all or any disputes arbitration.
Contractor should have to be registered with Employee Provident Fund Organization (EPFO). It is mandatory for contractor to submit PF code provided by EPFO with their tender offer. Also each contractor have to submit "UAN" of their worker with their offer and have to mention in tender document. It is mandatory. Otherwise offer will not be considered for further action and your offer will be summerisely rejected. You are also instructed to submit monthly payment challan to the person/labour engaged for execution of the work having valid UAN no with bill. This is to be followed strictly as per GCC & as per instruction of labour enforcement officer under Govt of India.
Inclusion of 'Letter of Credit' as Mode of Payment in Works Tenders or Service Tenders as per Railway Board's letter no. 2018/CE-I/CT/9 dated 04.06.2016 remarks from Tenderer required.
Eligibility criteria for works tender in respect of partnership firms:-
in case the tenderer is a partnership firm s , the experience, solvency and turn over shall be in the name and style of the firm only.
If the tenderer is a partnership firm, all the partners shall be jointly and severally liable for successful completion of the work and no request for change on the certification of the firm shall be entertained.
During the currency of the contract, no partner of the firm shall be permitted to withdraw from partnership business and in such and event it shall be treated as breach of trust and abandonment of the contract.
JOINT VENTURE will not be permitted for the tenders.
Any Conditional offer will be summarily rejected.
Rates are inclusive of all taxes/GST, license fee, royalty charges etc. legally leviable by State, Central Govt. and/or any other local authority.
Railway Administration reserves the right to change/Alter/Cancel the tender without any notice.
At SEE Divn.:- Provision of 70-30% automatic lighting arrangement on platform of stations in SEE Division.
L-Open-26-27-01Dt02-04-26
L-Open-26-27-01Dt02-04-26
Open
Works - General
180 Days
Saran, Bihar
₹0
₹5.3 L
24 Apr 2026
2 Apr 2026
10 Apr 2026
27 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,67,41,185.2 | ||
| — | 14.00 | — | — | ||
| Supply, installation, testing and commissioning of Intelligent Field Device (IFD) having inbuilt energy metering, Analog Inputs, Digital Inputs, Digital Outputs, GPRS communication /ethernet, LAN, WiFi, etc., display along with filter power circuit having fuses, AC to DC power supply providing adequate DC Supply options (viz.5V/12V/24V etc) with battery back for monitoring and control 30-70% Lighting capable of monitoring & control electrical parameters, sensors parameters with necessary control capability through internet cloud computing along with integration with CRIS Software as per specification. A) IFD (2X2) | — | — | — | 25,58,150 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing and commissioning of Intelligent Field Device (IFD) having inbuilt energy metering, Analog Inputs, Digital Inputs, Digital Outputs, GPRS communication /ethernet, LAN, WiFi,etc., display along with filter power circuit having fuses, AC to DC power supply providing adequate DC Supply options (viz.5V/12V/24V etc) with battery back for monitoring and control 30-70% Lighting capable of monitoring & control electrical parameters, sensors parameters with necessary control capability through internet cloud computing along with integration with CRIS Software as per specification. (B) IFD (4X4) | — | — | — | 10,23,840 | |
| — | 460.00 | — | — | ||
| Supply, installation & commissioning of signal sensor unit 50 MA 24 volt Microprocessor based digital circuit for home starter & track relay. | — | — | — | 1,47,30,580 | |
| — | 62.00 | — | — | ||
| Supply, installation & commissioning of automatic load controller unit 415 V 63 A within built digital circuit with relay 40 A having NO & NC contacts to be fitted parallel across the switch for automatic operation as per direction of engineer in Charge at site/As per typical circuit diagram. | — | — | — | 27,20,436 | |
| — | 7000.00 | — | — | ||
| Supply & laying & wiring of 1.1 KV grade PVC insulated & sheathed single core 1.5 sq.mm 2 stranded copper cable through suitable size PVC rigid conduit HDPE/casing capping not less than 19 mm wide and thickness 1.2 mm with Tee , Bend etc as per direction of engineer in Charge at site . Make of cable Finolex, Havell 's , Anchor , KEI , Goldmedal or approved ISI make. | — | — | — | 3,01,000 | |
| — | 14200.00 | — | — | ||
| Supply & laying & wiring of 1.1 KV grade FRPVC insulated multistrand single core 16 sq.mm electrolyte tic grade annealed copper wire conforming to IS : 694/1990 to be laid through HDPE pipe ( item no. 5 ) as per direction of engineer in Charge at site . Make of Finolex, Goldmedal or approved ISI make. | — | — | — | 32,66,000 | |
| — | 900.00 | — | — | ||
| Supply & laying of HDPE pipe 50 mm dia of pressure rating 5 kgf/sq.cm (pn- 6.0) to be laid along with wall/beam by MS clamp or under the ground by digging the trench of depth one mtr from ground level for protection of cable. Necessary compression socket and short radius compression bend to be provided as per direction of engineer in charge at site, Make - Malhotra , Durga , Finolex , Jindal , Tata. | — | — | — | 1,53,000 | |
| — | 62.00 | — | — | ||
| Supply connection and fixing of SFU TPN 63 A with proper fixing arrangement on the specified location as per direction of engineer in charge at site. Make L& T , Havells, C & S , Standard, HPL, Legrand, Indo Asian , Panasonic or similar reputed make | — | — | — | 3,39,512 | |
| — | 62.00 | — | — | ||
| Supply, installation testing and commissioning of High voltage Protection with integrated circuit for protection of solar devices electrical devices and appliances from high voltage up to 440 volts in the station building of reputed ISO certified make. | — | — | — | 15,25,175.2 | |
| — | 16.00 | — | — | ||
| Supply and Fixing of Relay & Base for Read Back as per Site Requirement. | — | — | — | 12,160 | |
| — | 4.00 | — | — | ||
| Supply and fixing of CT's set (3 Nos.) With enclosure as per Site requirement. | — | — | — | 6,180 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing & commissioning of power contactor single phase 25A/32A/40A with accessories as per site requirement as per specification. | — | — | — | 27,168 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing & commissioning of power contactor single phase 63A/100A with accessories as per site requirement as per specification. | — | — | — | 77,984 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCACS11.pdf
ATTACHMENT
Tender document
ATTACHMENT
I_CT_GCC-
ATTACHMENT
GCCACS1-9.pdf
ATTACHMENT
Advancecorrectionslipno.10.pdf Advance correction slip no 10
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
Advancecorrectionslipno.10.pdf
ATTACHMENT
Tenderdocument70-30lighting2_2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .