Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.0 L+₹2.1 L (6.57%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹36.7 L+₹4.8 L (15.2%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹39.5 L+₹7.6 L (23.9%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹47.0 L+₹15.1 L (47.4%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹85,250
Closing Date
24 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR MAINTENANCE OF US SECURITY LIGHT AND ALLIED WORKS INCLUDING DAILY MAINTENANCE OF SECURITY LIGHTS UNDER GE WEST BAREILLY
2020_MES_372741_1
8864/E8
Open Tender
Civil Works
Item Rate
335 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORYSCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRM
SCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹85,250
Yes
28 Oct 2020
28 Aug 2020
29 Sept 2020
28 Aug 2020
24 Sept 2020
10 Sept 2020
28 Aug 2020 - 9 Sept 2020
60 days
Amount
Dismantling of SVL / MVL/ MH / LED/FTL light fittings of any capacity from existing poles / buildings of any height/type including re-fixing after repair/replacment of unserviceable parts such as FTL/lamps / ballasts / ignitors / holder/starter/ bipin holder etc and making the fitting functional by replacing minor parts such as nuts,bolts PVC connector complete all as specified and directed. Notes:- (a) Spares shall be measured & paid separately as given here-in-after. (b) Contractor shall provide minimum 2 Electrician and 2 helper to carry out the repair / Maint work of security lights in day shift (900 Hrs-1700 Hrs) and they have to report AGE E/M-I yard for daily assingment/task (c) Contractor shall provide all tools and plants and minor spares such as Ladder minor nuts bolts, jumper wire, insulation tape etc required for doing the job related with electric supply including mobile phones for communication and will be fully responsible for safety and security of their man. ( d) In case non reporting of required staff in AGE E/M yard the recovery shall be made @ Rs 1000/= per day .
Supply only ignitor suitable for 70 / 150 / 250 / 400 Watts HPSV lamps of make Bajaj Cat No. BJIGN HPSV or equivalent model in Crompton greaves, Philips complete all as specified and directed.
Supply only HPSV Lamp 70 Watts suitable for HPSV fitting of make Bajaj or equivalent model in Crompton greaves, Philips complete all as specified and directed.
Supply only HPSV Lamp 150 Watts complete all as specified and directed. Make - Crompton, Bajaj, Philips.
Supply only HPSV Lamp 250 Watts complete all as specified and directed. Make - Crompton, Bajaj, Philips.
Supply only MH Lamp 150 Watts complete all as specified and directed. Make - Crompton, Bajaj, Philips.
Supply only MH Lamp 250 Watts complete all as specified and directed. Make - Crompton, Bajaj, Philips.
Supply and fixing in replacement electronic ballast (choke) suitable for 2 x 14 watt T-5 lamp complete all as specified and directed. Make : Bajaj/GE/ Phillips/CG/Havells/Surya/Wipro.
Supply only electronic ballast (choke) suitable for 2 x 24 watt T-5 lamp complete all as specified and directed. Make : Bajaj/GE/ Phillips/CG/Havells/Surya/Wipro.
Supply only HPSV copper ballast 70 Watts of make Bajaj Cat No. BJOS 70 SV/MH or equivalent model in Crompton greaves, Philips complete all as specified and directed.
Supply only HPSV copper ballast 150 Watts of make Bajaj Cat No. BJOS 150 SV/MH or equivalent model in Crompton greaves, Philips complete all as specified and directed.
Supply only HPSV copper ballast 250 Watts of make Bajaj Cat No. BJOS 250 SV/MH or equivalent model in Crompton greaves, Philips complete all as specified and directed.
Supply only lamp holder screw type suitable for 70 / 150 / 250 / 400 Watts HPSV / HPMV lamp fittings complete all as specified and directed. Make - Crompton greaves, Bajaj, Philips.
Supply only bipin holder suitable for fluorescent tube light fittings 4x24 watt and 4x14 Watts complete all as specified and directed. Make - Crompton, Bajaj, Philips.
Supply only T-5 flourecent tube rod 1x14watt suitable for Energy conservation T5 lamp road way lighting luminaries .
Supply only T-5 flourecent tube rod 1x24watt suitable for Energy conservation T5 lamp road way lighting luminaries .
Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for 30 watt to 50 watt LED light for existing complete all as specified and directed.
Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for 60 watt to 72 watt of epoxy powder coated hsg complete all as specified and directed.
Supply only of Integral LED street light driver, enclosed with glass cover frame suitable for 90 watt LED light existing complete all as specified and directed.
Supply only of Integral LED street light module with complete PCB and LED bulb suitable for 30/50 W LED street light for existing complete all as specified and directed.
Supply only of Integral LED street light module with complete PCB and LED bulb suitable for 65/72 W LED street light for existing make and model complete all as specified and directed.
Supply only of Integral LED street light module with complete PCB and LED bulb suitable for 90/100 W LED street light for existing make and model complete all as specified and directed.
Supply only cable two core PVC insulated and unsheathed multistranded aluminium conductor of size 2.50 Sqmm complete all as specified and directed.
Supply and fixing MCBs TPN 63 Amps,415 Volts 16 KA all as specified and directed.
Supply and fixing MCBs SPN 32/40 Amps,220 Volts 10 KA all as specified and directed.
Supply and fixing MCBs single pole 6-32 Amps 10 KA ,220 Volts all as specified and directed.
Supply and fixing powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 36Watt
Supply and fixing powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 45Watt
Supply and fixing powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 60Watt
Supply and fixing powder coated pressure die cast aluminium compact LED street light fitting heat resistance toughened glass with lens suitable for 72Watt.
Supply and fix in repairs loop-in loop-out box of size 20x15x15cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on top with provision of aluminium busbar of size 25 x 2mm - 2 Nos fixed on insulator and MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc
Supply and fix in repairs loop-in loop-out box of size 20x30x15cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on top with provision of aluminium busbar of size 25 x 2mm - 4 Nos fixed on insulator and one MCB of capacity 6 Amps complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc
Supply and fixing powder coated pressure die cast aluminium compact LED flood light Lumos heat resistance toughened glass suitable for 100 Watt..
Supply and fixing street light bracket made out of 40 mm dia GI pipe light grade of length upto 1.2 mtr bent to shape required with and including 2 Nos, 50 x 6 mm MS flat iron clamps with nuts, bolts, washer etc and applying one coat of aluminium paint to clamps including dismantling of old brackets complete all as specified and directed.
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 12KW IP, single phase ,max load 12KW Manufactured by KAKATIYA ENERGY SYSTEMS LTD HYDERABAD or equivalent of other make complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 3KW IP, single phase ,max load 12KW Manufactured by KAKATIYA ENERGY SYSTEMS LTD HYDERABAD or equivalent of other make complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor
Supply ,fixing ,commisioning and testing of Nature timer switch control Street Lights complete with MCB, Power and Panel duly complete with wiring Model : SWADEEP-02EC 12KW3P, three phase ,max load 12KW Manufactured by KAKATIYA ENERGY SYSTEMS LTD HYDERABAD or equivalent of other make complete all as specified and directed. Note :- CA No & date of installations shall be painted/marked on all timer switch provided by the contractor
Taking down PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch any size complete all as specified and directed.
S&F 1100 Volts grade heavy duty cable one twin core, flat or circular 6 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. Make Havells/ Polycab.
S&F 1100 Volts grade heavy duty cable one twin core, flat or circular 10 Sqmm PVC insulated aluminium stranded conductor served with inner sheathing of PVC tapes and overall PVC sheathed in service connection from pole to Main Switch complete all as specified and directed. Make Havells/ Polycab.
Taking out old unserviceable Old LT cable any type and size from trenches or fixed on poles or through pipes/walls/laid under roads/paths/ drains/culverts complete all as specified and directed.
Excavation in trenches n. exc. 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
Laying old bricks,removed from item no.45 for protection of under ground cable complete all as specified and directed.
Making horizontal bore hole under road of 50 mm bore size at the depth not less than 1 mtr below ground level for passing of LT underground cable complete all as specified and directed.
S & F in replacement GI pipe light grade 40 mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
S & F in replacement GI pipe light grade 50 mm bore for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified & directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I - 1988 with aluminum conductor 1100 Volts grade of cross sectional area 10 Sqmm , 2 core in ducts or on walls laid in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty, conforming to IS - 7098 Part I - 1988 with aluminum conductor 1100 Volts grade of cross sectional area 16 Sqmm , 4 core in ducts or on walls laid in trenches encased in GI pipe fixed to walls / laid under roads / drains / paths / culverts etc complete all as specified and directed.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines / HT over head lines conductor upto 3 mtr from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. Note :- (a). The trees branches etc will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO / DEO and they will be responsible to lift the wood. (b). Prooning of all tree branches in one tree shall be measured as one Job. c). Contractor will employ sufficient labour to complete the job with in time as directed. (d). Contractor will be responsible for any type of mis-happening / accident while prooning the trees. (e). Contractor supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f). The contractor will provide proper tools and safety devices to his staff for prooning of trees.
Dismantling of LT PCC/steel tubular pole of any size and discription incl coping, foundation etc
Supply and fixing of micro prismatic reftective sheet, min 2.5 cm wide, with adhesive base for dirtectly fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as directed.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31 09 mtrs long Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.
All as per srl item No.55 here-in-before but PCC 1:3:6 type C-2 as in foundation of stays and coping of poles.
Opening the binding wire from pin /shackleinsulator on steel pole of any height for re-stretching the ACSR conductor , after re-restretching without kinks & bends, binding the pin /shackle insulator with appropriate size of aluminium binding wire complete all specified & directed by Engineer-in- charge. Note: (i) The above work includes clearing /prooning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
Opening the binding wire from 'J' hook or opening nut, bolts,of cross arms on steel /pole of any height for re-stretching the galvanised iron earth wire any size, after re-restretching without kinks & bends, binding the 'J' hook with appropriate size of aluminium binding wire or fixing with appropriate size of nut,bolts,washers complete all specified & directed by Engineer-in- charge. Note: (i) Cost of binding wire,nut,bolts and washers deemed to be included in the quoted rate, No extra amount will be paid.
Taking down & Supply & fixing in replacement shackle type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators.
Taking down & Supply & fixing in replacement pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade, including removal of existing insulators.
Taking down & Supply, fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed.
Supplying,drawing and fixing in replacement of contineous GI earh wire/guard/cradles of 4mm dia including GI binding wire 1.63 mm and GI eye hook on LT poles incl taking down old rusted GI wire all as specified and directed.
Cleaning and preparation of old painted surface of old painted surface of LT steel tubular pole complete and painting with one coat of aluminium paint including channels/brackets,street light brackets.cross arms and making Red & white strips with synthetic enamelled paint of 30cm height,each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enamelled paint after making circular base with black synthetic enamelled paint and applying two coat of white wash on PCC coping complete all as specified
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI wire 4mm dia with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge.
Supply & fixing in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 02 mm dia aluminium binding wire all as specified & directed by the Engineer-in-charge.
Notes:-
M/S HINA ELECTRICALS
Ishtiaq and Sons
VINYAK TRADERS
SANJEEV ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .