GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
COMPREHENSIVE MAINT OF LT PANELS INCL SWITCHGEARS LT UG CABLE NETWORK AND STREET LIGHTS INCLUDING ALLIED WORK AT SECTOR A UNDER GE UTILITY AMBALA
2024_MES_681683_1
CA NO GE U AMB T 64 OF 2024-25
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
As per tender documents
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹88,000
6 Dec 2024
28 Oct 2024
28 Nov 2024
28 Oct 2024
26 Nov 2024
12 Nov 2024
28 Oct 2024 - 4 Nov 2024
Amount
Rectification of complaints under Haig Line Power House of HT UG/OH electric distribution network by attendng daily complaints including Sunday and holidays for round the clock and making the same serviceable in all respect alongwith replacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc. Quoted rate also include excavation of faulty cable and making seviceable with accessories like joints, Fuse wire for GOD switch complete all as directed to the entire satisfaction of Engineer-in-charge.
Rectification of complaints under Haig line Power House of LT UG /OH electric distribution network, street lights by attendng daily complaints including Sunday and holidays for round the clock and making the same serviceable in all respects alongwith replacement of any major part but including small length of cable (not more than 20 mtr), adhesive tape and other connected minor accessories shall also include visual inspection of OH lines, Earth Resistance of transformer, switch gear, GOD switch etc. Quoted rate also include excavation of faulty cable and making seviceable with accessories of all nature like No light, faulty insulator, broken conductor & cable fault , burnt out MCCB`s, MCBs, isolators, switch fuses, service cables etc upto DB in buildings/OTM complete all as directed to the entire satisfaction of Engineer-in-charge.
Notes for items No 01.00 to 02.00 :- (i) Any complaint left unattended by the electrician will be communicated to the JE in-charge /AGE E/M with reason. No charge will be paid for the complaint till the complaint is resolved. (ii) New material /stores provided for completing the job shall be measured and paid for separately under relevant items of BOQ. (iii) Contractor shall provide all type of T&P of HT/LT network, bamboo ladder, Meggar etc with safety gloves to each electrician for attending the external electric complaints. (iv) Contractor shall provide the complaint register 200 pages – 10 No, complaint book with 100 slips- 20 No. Booklets serially numbered in triplicate. (v) Contractor will provide 03 No. Experienced Electrician having minimum 5 years experience ( 01x three shifts per day) and 03 No. Helper having minimum 2 years experience ( 01 x three shifts per day) including Sundays and Holidays to attend HT Complaints. (vi) Contractor will provide well experienced and well conversant person for lodging the complaint in complaint cell of each power house during working hours from 0900hrs to 1700hrs on all working days including Sunday & all Holidays. (vii) The Contractor will provide insurance cover of minimum Rs 5 lakh per head under IE Rules 2003 and Minimum wages Act. (viii) The Electrician and helper will be interview by JE E/M /Engr-in-charge for verification of experience, character and sound mind and body. (ix) Cost of materials for laying of cables, stretching of OH conductor, burnt out joints, fuse wires, insulator and jumper will be measured and paid separately under relevant items as Material & Labour for. (x) The contractor may have to provided additional resources as per the direction of Engr-in-Charge for speedy disposal of complaints as and when required. If any manpower is absent penal charge @ Rs 1000/- per person will be levied to the contractor. Penal recovery @ Rs 500/- per complaint per hour will be levied to the contractor in case of late attending of complaint after reasonable time or 2 hours whichever is more as decided by Engr-in-Chage / GE
(xi) The scope of work cover all complaints received from above concern power houses will be lodged/docketed/attended/completed. The completion will be rendered on complaint register as well as on docket. Nature of fault may occurs given below :- (a) Blown out fuses (b) Faulty Insulator (c) Loose GOD male & female contact (d) Faulty cable joint (e) O/H conductor broken (f) Broken jumpers (g) Tightening of stay (h) Stretching of broken loose fault conductor and binding on insulators up to 3 span (j) Contractor will provide all the tools such as HT/LT meggar, Insulation Tester, Wrench, Rope, Bamboo ladder, search light and other tools and will maintain them in working condition all the time. (k) Tightening of service connection as preventive maintenance. (l) Proper Uniform shall be provided by the contractor for persons employed on duty as directed by Engr-in-Charge. (m) Tracing fault manually in LT/HT electric lines and underground cable network. (n) AC Complaints like connection / disconnection (o) Fault HT/LT switchgears (p) Switching ON/OFF street lights at appropriate time as directed by JE/Engr-in-Charge. Penal recovery for Rs 100/- per day will be recovered if street light are not put ON/OFF at appropriate time. (q) The area covered under the above power house consists of HT/LT overhead lines. HT/LT underground cables, distribution transformers, HT/LT switch gears, streer lights etc, including HT 11 KV incoming and numbers of outgoing HT feeders for the complete area. (r) Any other electric complaint which is considered essential by the department.
(s) Confirmation on completion of any nature of major complaints will be intimated to JE EM or Engr-in-Charge immediately. (t) The contractor will observe all labour laws as prevalent during the currency of work enacted by Central/State Deptt as well as Labour Commissioner Act. He shall also ensure, payment of minimum wages to the persons employed as per labour laws in vogue. (u) Insurance, Education Qualification and experience cert for the personnel employed on duty shall be submitted to Engr-in-Charge before take over the installation. (v) The contractor will provide the rain coats, gum boot and hand gloves in winter and summer season. (w) Contractor will have no rights to object the work carrying out by other contractor at substation or HT/LT distribution system of the power house area under comprehensive maintenance. However necessary handing taking over the assets will be carried out between the agencies. (x) Contractor will provide vehicle (Electrical 3 wheeler) for attending the complaint under above power house area.
Labour only carry out visual inspection of transformer including minor maintenance like dusting ,tightening of loose connection HT/LV Side and replacement of aluminium terminal and checking of transformer oil level ,top up if required ,checking of silca gel ,heating/replacement of silca gel all as specified and as directed.T&P required for the job is deemed to be included in contract. The record of the same will be submitted in the performa as directed.
Trimming of Tree branches about to touch into OH lines of HT/LT & minimum clearance of 5 Mtr from OH conductors, Proper shut down will be taken and maintained in the register complete all as specified and directed.
Maintenance of sub Station including cleaning In /out of surroundings areas, zeroing of grass in two pole & four pole structure ,loose filling of sand/pebbles as required,operations of GODs ,Measuring of earth resistance of transformer,GODs ,LA & Switchgears ,Records of Earth resistance will be maintained complete all as specified and directed.
Detecting of fault in cable HT/LT with fault locator equipment which is capable to supply as per cable of HT/LT (11 KV/430 Volts) serviceable to cable with Straight through joint of size 95-400 Sqmm, 3 core complete all as specified and directed. Notes: (a) The HT fault which is detected through cable fault locator will only be paid under this item including transportation charges deemed to be included in the quoted rate. (b) Charge of cable fault locator and DG set including transportation charge deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will levied Rs 500/ per hour. (d) Straight through joint , 95 to 400 sqm, 3 core, Labour charges, excavation and making joint deemed to be included in quoted rate.
Material & Labour in replacement for aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm complete all as specified and directed.
Material & Labour in replacement for aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm complete all as specified and directed.
Material & Labour in replacement for aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm complete all as specified and directed.
Supply only chemical (Round up) for remove unwanted vegitation/grass at various locations complete all as specified and directed.
Supply and fixing in replacement of Inverter battery 12 volt, 150 AH, C-10 type, Solar Tubular type complete all as specified and directed. Make: Exide/ Amaron/Luminious
Material & Labour for indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 25-50 Sqmm including taking down old unservicable joint complete all as specified and directed. Make: 3M/ Raychem/ MS Seal/ Denson
Material & Labour for indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm including taking down old unservicable joint complete all as specified and directed.Make: 3M/ Raychem/ MS Seal/ Denson
Material & Labour for indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-185 Sqmm including taking down old unservicable joint complete all as specified and directed.Make: 3M/ Raychem/ MS Seal/ Denson
Material & Labour for indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.50 240-300 Sqmm including taking down old unservicable joint complete all as specified and directed.Make: 3M/ Raychem/ MS Seal/ Denson
Material & Labour for straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4 x 25-50 Sqmm including taking down old unservicable joint complete all as specified and directed.Make: 3M/ Raychem/ MS Seal/ Denson
Material & Labour for straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm including taking down old unservicable joint complete all as specified and directed.Make: 3M/ Raychem/ MS Seal/ Denson
Material & Labour for straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-185 Sqmm including taking down old unservicable joint complete all as specified and directed.Make: 3M/ Raychem/ MS Seal/ Denson
Material & Labour for replacement of old UNSV shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and directed.
Material and labour for replacement of aluminium conductor steel reinforced (ACSR) of size 6/1 x 2.59 (Weasel) and 6/1 x 2.11 (Squirrel) or other existing type conductor ISI marked for LT over head lines on poles including stretching, tightening of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor complete all as specified and directed.
Material & Labour for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 Metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core including taking down existing complete all as specified and directed.
All as per item ser No 21.00 here in before but for 6 sqmm 2 core complete all as specified and directed.
All as per item ser No 21.00 here in before but for 4 sqmm 2 core complete all as specified and directed.
Material & Labour for replacement of MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type with thermal magnetic release complete all as specified and directed.
Material & Labour for replacement MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed.
Material & Labour for replacement of MCCB TPN 200 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed.
Material & Labour for replacement MCCB TPN 100/125 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type complete all as specified and directed.
Material and Labour for danger notice board/plate of 1.6mm thick mild steel sheet , vitreous enameled red colour with letters, figures , and conventional skull and bone in signal white colour and fixed with MS clamps bolts approved size ofr HT 25cmx20 cm including taking down existing complete as specified and directed.
Supply only of Tinned copper fuse wire of size 27/33 S.W.G. for GOD ISI marked complete as specified and directed.
All as per item ser No 29.00 here in before but for 23/24 S.W.G complete all as specified and directed.
Supply only of PVC self adhesive insulation tape of Size .125mm x 25mm x 25 mtr long ISI marked all as specified and directed.
Material & Labour for straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 x 70-120 Sqmm including taking down old unsv HT joint complete all as specified and directed.
All as per item ser No 32.00 here in before but for cable 150-400 sqmm, 3 core complete all as specified and directed.
Material & Labour in replacement for cable end termination jointing kit HT 11 KV grade earthed system (heat shrinkable) outdoor type complete with jointing material suitable for HT XLPE cable 70-120 sqmm 3 core 11 KV grade earthed system as specified and directed. Make: 3M/ Raychem/ MS Seal/ Denson
All as per item ser No 34.00 here in before but for cable 150-400 sqmm, 3 core complete all as specified and directed.
Supply and fix in replacement LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete all as specified and directed.
All as per item ser No 36.00 here in before but for 5 line complete all as specified and directed.
Re-stretching existing/retrieved ACSR conductor on LT /HTpole and binding conductor on insulator properly using new binding wire/jumper wire complete all as specified and directed. Note : (i) Each Run of line conductor shall be measured in Running Metre from pole to pole.
Material & Labour in replacement of steel nuts, bolts, washers of any size required at site as specified and directed .
Material & Labour for preperation of old decorated surfaces of walls chajjas balcony facia etc and applying two coats of exterior emulsion paint complete all as specified and directed.
Material & Labour for prepering old painted steel suraces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as speciied and directed.
Material and labour of Bamboo ladder 24' height (24 steps ) for LT line and 27 ' height (27 steps ) for HT line complete all as specified and directed.
Supply and fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity upto 200 KVA complete all as per specified and directed.
Supply only for loose filling in substations, under poles, under transformers of hard core broken to gauge not exc 63 mm broken stone/boulders incl leveling and spreading lime stone powder under stones complete all as per specified and directed.
Material & Labour for providing plain cement concrete 1:3:6 (using 20 mm grade stone aggregate) as in coping, finished even and fair, including necessary form work complete all as specified and directed.
Material & Labour for for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified including taking down the old unsv cross arms and misc accessories complete all as specified and directed.
Supply only pouring new transformer oil as per IS : 335 (1993) for transformers installed at various site for topping up to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and directed. Note : Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge, Container shall be deposited by the contractor to the deptt, which will be returned after completion of contract.
Labour only in replacement of silica gel 4-6 mesh suitable for transformers breather and protect VCBs, RMUs from moisture at 11 KV stations complete as per site requirement complete all as specified and directed.
Taking down old unsv GOD and Supply, installing, testing and commissioning of air break gang operated triple switch( GOD) outdoor type , vertical mounting type of capacity 200 Amp with drop out fuse consisting 12 insulators ISI marked mechanically operated mounted on insulator and frame work with operating GI rods and mechanical work from ground level with locking arrangement including Godrej pad lock with two keys complete with fuse carrier and HT fuse element having upto 200 Amp rating suitable for HT 11 KV 50 HZ AC supply including necessary electric connection complete all as specified and directed.
Supply, install, testing and commissioning lightening arrestor suitable for HT 11 KV expulsion type 65 KA 11 KV rating including taking down existing complete all as specified and directed.
Material & Labour for surface cleaning of LT steel tubular poles 9 mtrs long including removing rusted particles painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified and directed. Note : (i) The quoted rate shall includes making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge.
Material & Labour for cement base paint for PCC pole 9 mtr including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc incl incl repairing and painting on coping with cement base white paint complete all as specified and directed. Note : (i) The quoted rate shall includes making of numbers on self adhesive stickers on each LT pole as per direction of Engr-in-Charge.
Material and labour in replacement of broken earth pit of size 300x300x300 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result complete all as specified and directed.
Material and labour in repairs of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash complete all as specified and directed.
Supply and fixing in replacement of off load change over switch with sheet steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed.
All as per item ser No 56 here in before but for 200 Amps capacity complete all as specified and directed.
Material and labour for shifting of heavy items upto 5 Ton weight by providing crane/hydra/excavators/tractors/ trolley etc as required at site complete, all as specified and directed.
Supply & Fixing in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket with clamp from juction box to connecter of street light fitting complete all as specified and directed.
Supply & Fixing in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps complete all as specified and as directed.
Supply & Fixing in replacement of extended spreaders link should be installed both side with exisitng/new MCCBs 4P/3P of any capacity with existing LT panels complete all as specified and directed.
Material & Labour for Chemical spray (DC 2.26 contact cleaner) in container of 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum cleanese etc complete all as specified and directed.
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium busbar and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and directed. Make: Havells/Sintex.
Supply and fix in replacement of MCB SP 6-32 Amps, 240 volt,10 KA 'B' curve including all accessories complete all as specified and directed.
Supply and fix in replacement of MCB DP 16-40 Amps, 240 volt,10 KA 'B' curve including all accessories complete all as specified and directed.
Supply and fixing in replacement of single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed.
All as per item ser No 66 here in before but for 2.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in above quoted rates.
Taking down old unserviciable board and supply and fixing of Retro reflective sign board of size 600 x 750 sqmm made of ACP sheet of 3mm thick ACP sheet shall be fixed on MS frame with legs of MS angle section 35mm X 35mm X 4mm grouted in PCC 1:3:6 type C-1, 750mm above the ground level and 600mm below the ground level. The background of board to be provided with red colour, letters and border with white retro reflective tape. Same description shall be mentioned on both sides of ACP sheet complete all as specified and directed. NOTE:- (i) Excavation, earth work, PCC, nuts, bolts, fastners, paint on MS frame and legs shall be included in quoted rates by contractor. (ii) The size of letters and description shall be all as per sample approved by Engr-in-Charge.
Dismantling and taking down security light, street light, hanger light, flood light and high mast lights of any type at any height fittings such as HPSV/HPMV/MH/LED light of 48 Watt/ 60 watt / 70/72 watt/ 90 watt/ 120 watt/ 150 watt/ 200 watt and 300 watt of any make etc. AC 230 volts any wattage from pole/wall roof top/hanger roof including washing/cleaning of perplex cover inspection for location of fault and replacing of defective spare/parts required for smooth functioning, tighting of electric connection complete and assembling and reconnecting all as per site requirment complete all as specified and directed. Note: Defective spare/ part of relevant light fitting shall be measured and paid separately under relevant item as supply only.
Supply only LED electronic driver/adaptor/SPD for 40-60 watt LED security light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 70/72 watt LED security light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 90 watt LED security light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 60-150 watt LED flood light fitting as per existing make complete all as specified and directed.
Supply only LED electronic driver/adaptor/SPD for 200-300 watt LED flood light fitting as per existing make complete all as specified and directed.
Supply & fixing in replacement of Integral LED Flood light Luminaries 150 Watts consisting of suitable number of LEDs and mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens, IP 66 protection suitable for mast light mounting, 5700K, LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV , Confirm the tests from auth labs : LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Note :- PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to flood light shall be measured and paid for separately.
Supply & fixing in replacement of LED street light fitting 90 watts made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded toughened glass having TOP Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 consisting of suitable number of LEDs with sealed toughened glass cover, 5700K, LED efficiency >110 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 140 V-270 V, Power factor> 0.95,mains current 0.270A, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV, better optics for uniform distrubution with multiple LEDs not less than 2 watt each and having optical grade polycarbonate lens with all accessories , suitable for side entry, pole mounting with bracket arm OD 40 mm, recommended mounting height with suitable inground reinforcement is 8 mtrs, Confirm the safety test as per IS 15885 part-2 from auth labs : LM79 & LM 80, incl proper fixing and testing of street lights on 9/11 mtr long steel tubular pole incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as specified and directed. Note :- PVC heavy duty conduit pipe along with 3/1 run of 1.5/2.5 sqmm PVC insulated unsheathed/sheathed copper multistranded conductor from MCB box to street light shall be measured and paid for separately.
Material & Labour for repairing the GOD mechanism pipe and handle lever, etc. by way of welding, greasing including supply and fixing of new male and female contact complete all as specified and directed.
Supply and topping up of Acid Mixture suitable for Lead Acid batteries of capacity 12V / 24V complete all as specified and directed.
Supply & Fixing in replacement heavy duty battery cable lead of copper conductor with copper lugs terminal for the 12V 180 AH maintenance free battery suitable for DG set complete all as specified and directed.
Supply and Fixing self-fusing Ethylene Propylene Rubber(EPR) based high-insulating voltage tape of width not less than 19 mm and thickness not less than 0.75 mm of any length to protect HT/LT XLPE cable from moisture and current leakage complete all as specified and directed .
Supply and Fixing in replacement of breather transparent type suitable for step down distribution transformers of capacity from 200 KVA to 1000 KVA complete all as per specified and directed.
Supply & Fixing in replacement HT discharge rod 11-33 KV FRP type with all accessories complete all as specified and directed .
Supply & Fixing in replacement HT rubber hand gloves 11 KV with electrical insulated latex seamless complete all as specified and directed .
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the LT XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as specified and directed. (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and directed.
Material & Labour for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR part I complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV,Type 1 with peak, size 250mm x 150 mm x 40 mm including taking out existing cable cover of any type complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and directed.
Material and labour for vibratory compactive, precast cement concrete rubber moulded, coloured (except grey colour), interlocking designer paver blocks in Milano shape, comfirming to IS-15658-2006 of 60 mm thickness, M-35 grade, as in path, harding standing, etc laid over and including 25 mm compacted sand cushioning, including 75 mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including surface excavation over area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and removing excavated soil exc. 50 mtr but n. exc. 250 mtr including demolition of existing tiles complete all as specified and directed.
Material & Labour for Brickwork with subclass 'B' brick bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed.
Material & Labour for rendering 15 mm in CM 1:6 thick on fair faces of brick work or concrete surface finished even and fair cement complete all as specified and directed.
Disconnecting & taking out defective underground cables any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and directed.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4.0 core including Al thimbles laid in trenches/on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc complete all as specified and directed. Note : (i) Earth work, sand, bricks removing, returning filling will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per item ser No 95.00 here in before but for 4 core 16 Sqmm
All as per item ser No 95.00 here in before but for 3.5 core 25 Sqmm
All as per item ser No 95.00 here in before but for 3.5 core 35 Sqmm
Supplying and fixing in replacement of light grade galvanised mild steel pipe 50mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers all as specified and directed. Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule.
Dismantling and taking down old UNSV LT panel and Supply, installing, testing & commissioning outdoor type cubical panel board of size 2.0mX1.8mX.75m, outer shell made out of 3.15 mm thick CRCA sheet and 60 to 70% outer doors covered by Perspex sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Copper bus bar of 1000 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :- (a) Air circuit breaker 800Amp 4 pole, 50KA with microprocessor release MDO- 01 Nos (b) MCCB 400 Amps, 50 KA 4 pole 415 Volts AC, adjustable type, (incoming)-03 Nos. (c) MCCB 250 Amp, 415 volt, 4 pole, breaking capacity 25 KA , adjustable type (Outgoing)-02 Nos. (d) MCB TPN 63 Amp, 415 Volts- 01 Nos (e) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (f) Digital multi function meter -01 Nos (g) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates complete all as specified and directed.
Supply only hand held electric brush cutter having min 1000 RPM, with grass trimmer min 7000 RPM with 1200 Watts rear motor and assist handle split shaft with accessories for trimming power houses lawns, substation sorrundings etc. The handles of the cutter must be provided in loop type for easy to operate and move around complete all as specified and directed. Make : Neptune/ Green craft/ Moti garden/ Usha.
Supply only heavy duty PVC body, Rechargeable battery operated double motor pesticide/ chemical high pressure sprayer of 20 ltrs capacity, battery lead acid 12 volt x 12 AH, 4 nozzles, telescopic lance, LED bulb with long wire, on-off trigger with filter, pair of belts, charger, water hose, spray gun etc. with accessories for spraying of pesticide chemical in power houses lawns, substation sorrundings etc. The spray machine must be provided in loop type for easy to operate and move around complete all as specified and directed. Make : Odyssey/ Agri pro/ Hymark.
Note:- Amount of credit of Rs. 100004.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
R. P. Suppliers and Construction Co. (BID ID -3174161)
Gupta Enterprises (BID ID -3169424)
RAJINDER KUMAR AND ASSOCIATES (BID ID -3169461)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .