Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.0 LAccepted-AOC | ₹20.0 L Quoted ₹21.2 L | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER |
| 2 | 2₹22.0 L+₹78,560 (3.70%)Rejected-Finance HOUSE NO 36 93 354 9 INDIRA NAGAR 5 NH 16 KANCHARAPALEM POST VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | ₹22.0 L+₹78,560 (3.70%) | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 3 | 3₹24.9 L+₹3.7 L (17.6%)Rejected-Finance 9 LAXMI NARAYAN PURA RAMPURA UNTI SANGANER JAIPUR RAJASTHAN 302001 | JAIPUR | RAJASTHAN | 302001 | ₹24.9 L+₹3.7 L (17.6%) | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 4 | 4₹25.1 L+₹3.9 L (18.4%)Rejected-Finance | ₹25.1 L+₹3.9 L (18.4%) | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 5 | 5₹30.5 L+₹9.3 L (43.6%)Rejected-Finance | ₹30.5 L+₹9.3 L (43.6%) | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
21 Aug 2021, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE
GARRISON ENGINEER (NAVAL BASE), NAUSENABAUGH, GANDHIGRAM POST 530005
REPAIR AND REPLACEMENT OF INTERNAL ELECTRICAL FITTINGS, FIXTURES, DBS, SUB MAIN WIRING AND MISC E/M WORKS AT HQ UNIT SATAVAHANA, VIRBAHU AND NAVAL DOCKYARD AREA UNDER GE (NB) VISAKHAPATNAM
2021_MES_464314_1
C/8919/E8 / Token 43 of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹84,000
Yes
23 Sept 2021
31 Jul 2021
23 Aug 2021
31 Jul 2021
21 Aug 2021
14 Aug 2021
Amount
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as directed.
Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit not less than 20 mm bore medium grade (ISI marked) concealed / surface fitted type including Flush type metal GI boxes for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases (if any) for concealed wiring including making good the same as per the existing one (iii) Modular white cover plate shall be measured and paid seperately)
All as per item No. 05 above but for One light point controlled by two way switch complete all as specified and as directed.
All as per item No. 05 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 05 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
All as per item No. 05 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistranded FRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F steped type modular fan regulator ,100/120 W, 2 module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F Modular socket outlet 6A/16A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments) complete all as specified and as directed.
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and two run of conduit shall be measured as one length)
S & F Distribution Board, TPN, 6 Way, 415V, Double door with IP 54 protection complete all as specified and as diretced complete all as specified and directed. (Make: Legrand cat part No. 5076 91 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 54 protection complete all as specified and as directed. (Make: Legrand cat part No. 5076 40 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 54 protection complete all as specified and as directed. (Make: Legrand cat part No. 5076 41 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 54 protection complete all as specified and as directed. (Make: Legrand cat part No. 5076 42 or equivalent make as per List of Manufacturer's)
S & F Distribution Board, TPN, 4 way, 415V, Double door with IP 54 protection complete all as specified and as diretced complete all as specified and directed. (Make: Legrand cat part No. 5076 90 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Legrand cat part No. 4085 87 to 95 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts, 10KA, C Curve complete all as specified and as directed (Make: Legrand cat part No. 4086 14 to 17 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Legrand cat part No. 4086 18 to 20 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB, Four Pole, 6-32Amps, 415V Volts, 10KA, C curve complete all as specified and as directed (Make: Legrand cat part No. 4086 91 to 99 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB, TPN 63 Amps, 415 Volts, 10KA, C Curve complete all as specified and as directed (Make : Legrand Cat part No. 4086 81 to 83 or equivelant of make as perList of manufacturer's)
Fixing only serviceable light fittings any type including connecting up complete all as specified and directed (Note: Old serviceable light fittings as obtained from serial Item No 04 here -in-before shall be re-used).
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
S & F Vertical DB double door for provision for four pole MCCB upto 250A incommer 8 way 24 outgoing with IP 43 protection complete all as specified and as directed. (Make : Legrand cat part No. 5077 59 or equivelant of make as per List of manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make : Indo Asian Cat part No. 811122 to 811129 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make : Legrand Cat part No. 4086 18 to 20 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB, Four Pole, 40-63Amps, 415V Volts, 10KA, C curve complete all as specified and as directed (Make : Legrand Cat part No. 4087 00 to 02 or equivelant of make as perList of manufacturer's)
Supply, fixing, commissioning and testing in repairs MCB TP, 40-63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed (Make : Legrand Cat part No. 4086 59 to 61 or equivelant of make as perList of manufacturer's)
S & F in repair Spreaders, 3/4 pole Breakers complete all as specified and as directed. (Make: Indo Asia/ Legrand/Havell's)
S & F in repair Street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
S & F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F in repairs ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 10"x8" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover of size 6"x4" for fixing switches, sockets & regulator etc complete all as specified and as directed.
S & F in repairs Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
Supply and fix in repair fan capacitors of 2.5 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
S & F in repairs stepped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
S & F in repairs Switch socket combination 2 in 1, 5 pin, 6 Amps, flush type, 240 volts complete all as specified and directed.
S & F in repairs Switch socket combination 2 in1, 3 pin, 6 and 16 Amp, flush type, universal complete all as specified and as directed.
S & F in repairs switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed.
S & F in repairs bell push flush type, 6 amp 240 volts, complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F in repairs Modular socket outlet 6A/16A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments) complete all as specified and as directed.
S & F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F in repairs switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed.
S & F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular white cover plate with frame, but 3 module complete all as specified and as directed.
S & F Modular white cover plate with frame, but 4 module complete all as specified and as directed.
S & F Modular white cover plate with frame, but 6 module complete all as specified and as directed.
S & F in repairs modular bell push 6 amp 240 volts1 module,complete all as specified and as directed.
S & F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S & F in repairs MCCB enclosure suitable for MCCB as per site requirement complete all as specified and as directed.
S & F in repairs MCCB 415 Volt 16 KA, 3 Pole, 63 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 03 or equivelant of make as per List of Manufacturer's)
S & F in repairs MCCB 415 Volt 16 KA, 3 Pole, 100 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 05 or equivelant of make as per List of Manufacturer's)
S & F in repairs MCCB 415 Volt 16 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 17 or equivelant of make as per List of Manufacturer's)
S & F in repairs MCCB 415 Volt, 25 KA, 4 Pole, 250 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4202 19 or equivelant of make as per List of Manufacturer's)
S & F in repairs LED Drive 36/40 watts as per site requirement complete all as specified and as directed.
S & F in repairs LED Drive 10/14 watts as per site requirement complete all as specified and as directed
S & F in repairs LED Drive 24/36/40 watts Security lights as per site requirement complete all as specified and as directed
S & F in repairs LED Drive 100 watts for flood light as per site requirement complete all as specified and as directed
S & F in repairs capacitors of 25/36 Mfd suitable for 70/150 / 250watts HPSV/ MH luminaires complete all as specified and as directed. (Make : Bajaj / Phillips / CG)
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.complete all as specified and directed. (Make : C G Cat No. EXTN1LT8-16/20 and equivelant model of make as specified in list of manufacturer).
S & F in repairs Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed.
S & F in repairs Aluminium thimbles/ lugs for suitable size Cable complete all as specified and as directed.
S & F LED tube light batten fittings, T8, 18W with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Bajaj Cat No. BLRB-DB 118 or equivelant of make as per list of manufacturer)
S & F batten LED light fittings 9 watt (1000 Lumens), Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including lamp, fixing accessories and connecting up complete all as specified and directed. (Make : Havell's Cat No. LUMILINEBS9WLED865SPCWH and equivelant model of make as specified in list of manufacturer).
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core including taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core including taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately)
Taking down ceiling fan any sweep from the existing poistion and replacing the defective parts such as shakle & clamps including, rubber bush, bolts, nuts & split pin (Chera Pin), washer etc. for ceiling fan and ensure proper inserting the quarter/ Split pin to hold the nut and bolt on fan downrod at fix position including servicing, oiling, greasing and cleaning properly and re-fixing the ceiling fan of any sweep again at existing position all as specified and as directed .
All asper serial item No. 79 above but for exhaust fan any size complete ditto
Material and Labour for preparation of old metal surfaces of Panel Boards after complete removal of existing painting over 10cm width or girth not otherwise described and applying two coats of enamel paint (1st quality) of simens grey colour over a coat red oxide zinc chrome primer and marking the Qtr No, Panel Board No in front side complete all as specified and directed by engineer in Charge. (Note: Adjoing areas there to properly covered befor painting. Adjoing areas, floor, walls are to cleaned free of paint spillage after painting work. If Paint spill is not cleaned to match with exsting surface a panel recovery @ Rs.200/- per location will be made from payments due to the contractor).
M & L for Repairs to Panel board indoor type sheet metal approximate szie (5 x1.5 x 1.5 Feet's) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauges MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolts in MCBs and proper legging in cable and control wire sheet metal screws metal screws and painting the complete body with two coat of synthetic enamel paint over a coat of Zinc chrome primer and marking the Qtr No, Panel Board No in front side and all as specified and as directed
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
S & F in repairs 150 W, HPSV ballast complete all as specified and as directed. (Make : Bajaj/ Philips / CG/ Havell's)
S & F in repairs 250 W, HPSV/MH ballast complete all as specified and as directed. (Make : Bajaj/ Philips / CG/ Havell's)
S & F in repairs 150 W, HPSV Lamp complete all as specified and as directed. (Make : Bajaj/ Philips / CG/ Havell's)
S & F in repairs 250 W, HPSV Lamp complete all as specified and as directed. (Make : Bajaj/ Philips / CG/ Havell's)
S & F in repairs Ignitor for HPSV/MH luminaires complete all as specified and as directed. (Make : Havells /Bajaj/ Philips / CG)
S & F 2x2 recessed mounting slim panel light fittings, 36 W/3600 Lumens with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: CG Cat No. CCR-127-36-57-SL-NWH or equivelant of make as per list of manufacturer)
SAMPATH ENTERPRISES
M/S REAL POWER SYSTEMS
P Govinda Reddy Infrastructure
M/s Vinayaka Associates
SVG SUPPLIES
RATNA ENTERPRISES
ARCHANA ENGINEERING ENTERPRISES
Mavee Syndicate
Pavan Commercial Company
M/s SURYA INFRA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .