| Sl No | Description | Qty | Unit | M/S Abdul soleh L1 | M/S Goma Electric and Electronics L3 | M/S MANZOOR AHMAD L4 | M/S ANAYAT ALI L5 | M/S MOHD HASSAN L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00SITC of | ||||||||
| 1.01 | 11/0.433kV, 3-phase 250 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for63kVA or higher kVA with LV Cable Box having detachable Aluminiumratings) , and Gland plate | 1 | No | 4,50,000 ₹4,50,000 Lowest | 7,50,000 ₹7,50,000 | 8,00,000 ₹8,00,000 | 8,50,000 ₹8,50,000 | 7,50,000 ₹7,50,000 |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type | 2 | Set | 5,000 ₹10,000 | 4,000 ₹8,000 Lowest | 8,000 ₹16,000 | 9,500 ₹19,000 | 5,000 ₹10,000 |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type | 3 | Set | 15,000 ₹45,000 | 13,000 ₹39,000 | 8,000 ₹24,000 | 10,500 ₹31,500 | 6,000 ₹18,000 Lowest |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 2 | Set | 7,000 ₹14,000 | 5,000 ₹10,000 Lowest | 8,000 ₹16,000 | 7,500 ₹15,000 | 5,000 ₹10,000 Lowest |
| 1.05 | 95 mm²( or 70 mm² (2Ckt)/ 150 mm²( or 95 mm² (2Ckt)/300mm²( or 185 mm² (2Ckt) Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type | 44 | Mtr | 500 ₹22,000 | 250 ₹11,000 | 200 ₹8,800 Lowest | 550 ₹24,200 | 200 ₹8,800 Lowest |
| 1.06 | 9 Mtr. Long Pole,ST-410 SP33) | 2 | Nos | 22,500 ₹45,000 | 18,000 ₹36,000 | 20,000 ₹40,000 | 23,000 ₹46,000 | 17,000 ₹34,000 Lowest |
| 1.07 | 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm | 6 | Nos | 900 ₹5,400 | 1,000 ₹6,000 | 800 ₹4,800 | 900 ₹5,400 | 500 ₹3,000 Lowest |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 300 | Kgs | 200 ₹60,000 | 130 ₹39,000 Lowest | 190 ₹57,000 | 180 ₹54,000 | 200 ₹60,000 |
| 1.09 | Galvinized Nuts and Bolts. | 12 | Kgs | 140 ₹1,680 | 130 ₹1,560 Lowest | 200 ₹2,400 | 160 ₹1,920 | 200 ₹2,400 |
Tender Value
Refer Docs
EMD Value
₹46,200
Closing Date
1 Sept 2025, 1:00 pmClosed
Executive Engineer
baroo Kargil
Supply, Installation, testing and commissioning for Creation of sub- stations along with HT/LT network for providing Power supply to court complex Drass Kargil
2025_PDNRE_17316_1
E NIT 63 OF 2025-26
Open Tender
Electrical Works
Turn-key
30 days
Kargil District
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Account No 0096010200000064 IFSC Code JAKA0KARGIL)
₹46,200
11 Sept 2025
25 Aug 2025
1 Sept 2025
25 Aug 2025
1 Sept 2025
29 Aug 2025
Amount
SITC of
11/0.433kV, 3-phase 250 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound upto 200kVA, Copperwound for63kVA or higher kVA with LV Cable Box having detachable Aluminiumratings) , and Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
95 mm²( or 70 mm² (2Ckt)/ 150 mm²( or 95 mm² (2Ckt)/300mm²( or 185 mm² (2Ckt) Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
LT Distribution Box for 250 kVA DTR with MCCB for incomer & SFU's for Outgoing Circuits
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
8Mtr. Long Pole( ST-410 SP15)
50 mm LT AB Cable 3x50+1x16+1x35 mm sq XLPE 1.1 KC,3+1C
16 KN Polymer Shackle/Pin Insulator
Cement bottoming 1:2:4 mix as per REC standards .45cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp suitable for 33KV Pin & Disc insulators
30 mm² ACSR Conductor
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
11 kv tri vector Meter with suitable type CT (oil emersed)
M/S MOHD HASSAN (BID ID -168995)
M/S Goma Electric and Electronics (BID ID -168994)
M/S MANZOOR AHMAD (BID ID -169002)
M/S ANAYAT ALI (BID ID -169006)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .