Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹33.8 LAccepted-AOC NIL | L-1 | Accepted-AOC Being L1 | |
| 2 | L-2₹37.8 L+₹3.1 L (9.04%)Rejected-Finance GAIRKATA ROAD WARD NO 03 PO PS DHUPGURI DIST JALPAIGURI W B PIN 735210 | JALPAIGURI | WEST BENGAL | 735210 | L-2 | Rejected-Finance Being other than L1 | |
| 3 | L-3₹41.8 L+₹7.1 L (20.5%)Rejected-Finance P O BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | L-3 | Rejected-Finance Being other than L1 | |
| 4 | L-4₹43.0 L+₹8.4 L (24.1%)Rejected-Finance | L-4 | Rejected-Finance Being other than L1 | |
| 5 | L-5₹44.0 L+₹9.4 L (27.1%)Rejected-Finance 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L-5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | SHRI PRADEEP PARIK L1 | BBKundu L3 | ANIL KUMAR GUPTA L5 | flexpro construction company L4 | R K AGARWAL L7 | Samir Kumar Dey L8 | M/S MOHAN KUMAR BANSAL L6 | BIG BEN ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing complete all as specified and as directed. | 29 | Each | 35 ₹1,015 | 29 ₹841 | 66 ₹1,914 | 55 ₹1,595 | 65.5 ₹1,899.5 | 62 ₹1,798 | 68 ₹1,972 | 18 ₹522 Lowest |
| 2.00 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing complete all as specified and as directed | 593 | RM | 8 ₹4,744 Lowest | 9 ₹5,337 | 34 ₹20,162 | 25.5 ₹15,121.5 | 33 ₹19,569 | 35 ₹20,755 | 35 ₹20,755 | 8 ₹4,744 Lowest |
| 3.00 | S & F MCB TPN 415 volts suitable for fixing in MCB DB of capacity 16 to 32 amps complete all as specified and directed. | 9 | Each | 2,250 ₹20,250 Lowest | 2,309 ₹20,781 | 2,355 ₹21,195 | 2,340.5 ₹21,064.5 | 2,355 ₹21,195 | 2,350 ₹21,150 | 2,366 ₹21,294 | 2,290 ₹20,610 |
| 4.00 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one all as specified and directed. | 18 | Each | 2,450 ₹44,100 | 2,409 ₹43,362 Lowest | 2,484 ₹44,712 | 2,460 ₹44,280 | 2,480.5 ₹44,649 | 2,500 ₹45,000 | 2,480 ₹44,640 | 2,430 ₹43,740 |
| 5.00 | S&F MCB, Single pole & neutral,32 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed. | 27 | Each | 880 ₹23,760 Lowest | 959 ₹25,893 | 1,111 ₹29,997 | 975 ₹26,325 | 1,010 ₹27,270 | 1,000 ₹27,000 | 1,123 ₹30,321 | 925 ₹24,975 |
| 6.00 | S&F in repair MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed. | 9 | Each | 1,280 ₹11,520 Lowest | 1,309 ₹11,781 | 1,344 ₹12,096 | 1,335.5 ₹12,019.5 | 1,350 ₹12,150 | 1,350 ₹12,150 | 1,354 ₹12,186 | 1,292 ₹11,628 |
| 7.00 | S&F in repair MCB, SP, 6 to 32 Amps, 240 volts, ‘C’ curve, 10KA, 240 Volts to be housed in DBs including necessary connection complete including necessary connection complete all as specified and as directed | 68 | Each | 280 ₹19,040 Lowest | 299 ₹20,332 | 316 ₹21,488 | 310.5 ₹21,114 | 317 ₹21,556 | 320 ₹21,760 | 315 ₹21,420 | 296 ₹20,128 |
| 8.00 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one all as specified and directed. | 11 | Each | 2,850 ₹31,350 Lowest | 2,999 ₹32,989 | 3,000 ₹33,000 | 2,945 ₹32,395 | 3,000 ₹33,000 | 3,000 ₹33,000 | 3,000 ₹33,000 | 2,914 ₹32,054 |
| 9.00 | M&L for sub main wiring with 2 run of 10.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 10.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed.
(NOTE : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.
(ii)Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length) | 18 | RM | 430 ₹7,740 | 379 ₹6,822 | 394 ₹7,092 | 390 ₹7,020 | 425 ₹7,650 | 400 ₹7,200 | 394 ₹7,092 | 358 ₹6,444 Lowest |
| 10.00 | All as per item No 09 above but using two run 6.0 Sqmm multistranded copper conductor single core cable with one run 6.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed. | 350 | RM | 380 ₹1,33,000 | 289 ₹1,01,150 | 311 ₹1,08,850 | 295.5 ₹1,03,425 | 315 ₹1,10,250 | 310 ₹1,08,500 | 311 ₹1,08,850 | 272 ₹95,200 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 Nov 2025, 6:00 pmClosed
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR AND MAINTENANCE OF MCB DB, MCCB DB, SUBMAIN WIRING, REPLACEMENT OF BUILDING SECURITY LIGHT, EARTHINGS AT NORTH ZONE MD ACCN AND OTM ACCN AREA AND LT ELECTRICAL DISTRIBUTION SYSTEM AND ALLIED WORKS AT MANOJ PANDEY VIHAR AREA UNDER GE NORTH BINN
2025_MES_732442_1
8701 / 50 / 2025-26 / 08 / E8
Open Tender
Civil Works
Item Rate
270 days
Binnaguri cantonment
D class catg b(i)
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹70,000
Yes
10 Dec 2025
24 Sept 2025
3 Nov 2025
24 Sept 2025
1 Nov 2025
25 Oct 2025
Amount
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing complete all as specified and as directed.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing complete all as specified and as directed
S & F MCB TPN 415 volts suitable for fixing in MCB DB of capacity 16 to 32 amps complete all as specified and directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one all as specified and directed.
S&F MCB, Single pole & neutral,32 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S&F in repair MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S&F in repair MCB, SP, 6 to 32 Amps, 240 volts, ‘C’ curve, 10KA, 240 Volts to be housed in DBs including necessary connection complete including necessary connection complete all as specified and as directed
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/lsolators complete with and including taking down old unsv one all as specified and directed.
M&L for sub main wiring with 2 run of 10.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 10.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed. (NOTE : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’. (ii)Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length)
All as per item No 09 above but using two run 6.0 Sqmm multistranded copper conductor single core cable with one run 6.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed.
All as per item No 09 above but using two run 4.0 Sqmm multistranded copper conductor single core cable with one run 4.00 sqmm multistranded copper conductor single core cable as earth wire complete all as specified and as directed.
Supply and fixing of Sheet metal enclosures with socket two pin and earth plug top and MCB SP-20 Amp 230 volt complete all as specified and directed
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten/ conduit/ gutties/ wooden boards/ switches/ sockets/ regulators/ light fittings etc and seperating the serviceable items like fan regulators and light fittings for re-use under respective items and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
M&L for concealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including MS sunk box, 3mm thick hylum sheet top cover fixed by means of brass machine screw and cap washer including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for one light point controlled by one, one way switch 5/6 amps
All as per item No 14 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No 14 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No 14 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No 14 here in before but for one bell point controlled by one, bell switch 5 Amps
All as per item No 14 here in before but for one light point controlled by one, two way switch 5 Amps
All as per item No 14 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F switch piano flush type 16 amps single pole two way all as specified.
S & F bell push fush type 5 Amp 230 Volt complete all as specified and directed.
S&F socket 2 in 1, 3 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F of socket outlet 2 in 1, 3 Pin 6/16 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F in repair Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable, complete all as specified and directed.
S&F in repair Switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable, complete all as specified and directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S&F in repair modular switch,1 way, 6 Amp of one module complete all as specified and directed.
S&F in repair modular switch ,1way 16 Amp of one module complete all as specified and directed.
S&F Modular socket 6 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and directed.
S&F Modular socket 6/16 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and directed.
S & F in repair modular fan regulator 120W 230 volts AC 50 Hz 2 modules complete all as specified and directed.
S & F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F LED inverter type white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed.
S&F LED inverter type (warm) glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed.
S & F in repair deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 120 mm including taking down existing unserviceable.
S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable.
S&F in repair hylam sheet 3 mm thick white in colour of size 200 mm x 100 mm including taking down existing unserviceable.
S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable.
S&F in repair modular blank plates of 4 Module including taking down existing unserviceable.
S&F in repair modular blank plates of 6 Module including taking down existing unserviceable.
S&F in repair modular blank plates of 8 Module horizonat type including taking down existing unserviceable.
S & F wall mounted 4 feet LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as directed by Engineer-in-Charge.
S & F wall mounted 4 feet LED tube light(Inverter type) fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as directed by Engineer-in-Charge.
S & F round shape LED Surface light light 6 Watt fitting for armstrong/gridceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver ,high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mountintg arrangements, including necessary connection , complete all as directed by Engr-in-Charge.
S & F round shape LED Surface light light 12 Watt fitting for armstrong/gridceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver ,high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mountintg arrangements, including necessary connection , complete all as directed by Engr-in-Charge.
S & F LED color coordinated 5 m RGB strip with light travel function with IR , 40 W of along the surface on wall/ceiling /floor of the open shed and making suitable eletric connection to it all as specified & directed.
M & L for LED garden light 09 Watt made up of high grade unbreakable polycabonate material , IP 65 protection , cone series innovative design with uniformly lit diffuser at the upper portion incl taking out old unsv garden light fittings complete all as specified and directed.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed
S & F Energy saving new generation 9/10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as directed
S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified.
S & F Post top lanterns(Warm) 20 watt LED light fitting ,new generation, energy saving, environmental friendly, longlife with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories intenally prewired including connecting up with three core twisted flexible copper conductor cable up to cealing rose and necessary mounting arrangements, complete all as directed
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified.
Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note : The Excavation and earth work shall be mesured and paid separately under relevant item of Schedule.
Supply, laying, jointing & testing of LT cable in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
All as per ser item No 58 above but of cross sectional area 25 sqmm 4 core
All as per ser item No 58 above but of cross sectional area 70 sqmm 3.5 core
All as per ser item No 58 above but of cross sectional area 120 sqmm 3.5 core
Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pilar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminium lugs complete all as specified and as directed.
Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. Note : The serviceable cable obtained from taking out shall be reused.
M&L in replacement for Heat shrinakable straight through joint for 3.5 / 4 core cable 25sqmm to 50 sqmm and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
M&L in replacement for Heat shrinakable straight through joint for 3.5 / 4 core cable 70 sqmm to 120sqmm and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of size 23cmx12.5cmx7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
Laying only servicable Old bricks obtained after taking out LT cable of any size & type for protection of LT UG cable complete all as specified and as directed.
M & L for horizontal boring suitable upto 80mm steel tubing across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L in replacement of 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
M&L in replacement of 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
Dismantling of old U/S LT feeder pillar box/LT panel including PCC/Brick wks foundation after disconnecting of all elecrical connection complete.
Supply ,fabrication, installation and testing of LT feeder pillar ,out door type factory made ,CPRI Approved, junction box of size 800mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. (a) Copper bus bar of size 600 Amp wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, fabrication, installation, testing and commisioning in replacement of LT 3 Phase 4 wire 450 Volts system, factory made,CPRI Approved, water and vermin proof protection pedestal type feeder pilar box of minimum size 900 mm x 600 mm x 400 mm (overall) of out door type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable hinged door and air ventilation arrangement including provisio of cable looping box of size 700 x 600 x 350 mm . Danger notice plate with letters, figures and conventional skull and bones in signal red and shall be fixed on main door. The pannel shall be omplete painted with Powder Coated paint of approved shade. "U" type gas ket shall be used to make the inner shell completely vermin proof to accomodate incommers/outgoing MCCBs. All interconnection between the main bus bar as well as out going feeders shall be carried out with TPN coppe bus bar of rating not less than 1.5 times the rated capacity of individual out going feeders and should be insulated with heat shreank cable PVC shleaves and shall be mounted on suitable size "F" class insulators. The degree of protection of outer shell of the panel shall be IP-65. A detachable pre drilled gland plate should be used at bottom. All control wire shal be with 2.5 sqmm multi stranded copper conductors and shall be properly brunched, tied, ferruled for proper identification and print with adequate size of lugs complete with and including PCC (1:3:6) type C-2 of size 0.80 m x 0.60 m x 1.05 m depth (45 cm below ground level and 60 cm above ground level) as in foundation in cement mortar 1:6 and plastering the same in cement mortar 1 : 6 finished even and smooth with out using extra cement complete including necessaqry excavation, earth work and including connecting all incoming and outgoing LT UG cables after drawing/ digging out cable from loops in treanches complete all as specified and as directed along with and including comprising of the following accessories : - Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement. (a) Incomming Copper busbar 600 Amps capacity including insulator with nuts & bolts-04 Nos (b) Outgoing Copper busbar 400 Amps capacity including insulator with nuts & bolts-04 Nos (c) MCCB 4 pole, 415 volts, 36 KA breaking capacity adjustable thermal magnetic release with Ics=100% Icu, neutral adjustment 100% of rating 250 amps including all fixing accessories with both ends spreader links . ( Incomming -01 Nos) (d) Iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of FPB for LT -01 No.
M&L for preparation of the old decorated existing external steel surface of feeder pillar boxes/LT panels of any size and description in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopponf required and applying two coats of Asian aspa paint (Mahindra Grade) by using spray painting machine on old prepared surface including marking of Sub Stn No, Feeder No and feeding area/Bldg with applying synthetic enamel paint (1st grade) complete all as specified.
Supply & fixing in repairs/replacement LED indicating RED lamp, including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and directed.
Supply & fixing in repairs LED indicating YELLOW lamp, including necessary connection complete and including taking down / dismantling of old existing unserviceable one all as specified and directed.
Supply & fixing in repairs/replacement LED indicating BLUE lamp, including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and directed.
Supply & fixing in repairs/replacement CT coil 100/5 Amps including necessary connection and including taking down / dismantling of old existing unserviceable one complete all as specified and directed.
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Permises around pole, around panel board along boundaries fencing, removing runnish material from work site and depositing where directed not exc. 100 meter from the starting point complete all as directed.
Dismantling of existing unsv loose/disturbed Aluminum strip/GI Strip/Copper strip/Termination rod of any sizes on roof/down conductor fixed on wooden guities /directly on roof including screws etc complete.
Supply & fixing in repairs/replacement for 32 x 6 mm galvanised iron strip,earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or fixed to poles or roof with saddel and screw current complete all as specified and directed.
Disconnecting electric connection and Taking down of all UG cable from LT Panel/JB of any capacity and model removing of unserviceable spares / accessories for repair/replacement of the same including reconnection of all UG Cable connection with suitable lugs ,nuts & bolts etc. to existing LT Panel/JB and testing complete all as directed. Note:- Suitable Lugs,Nuts & Bolts shall be deemed to be in quoted rate..
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip complete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. complete all as shown in electrical plate of SSR Part I including testing on.
BIG BEN ENTERPRISES (BID ID -3471512)
BBKundu (BID ID -3472341)
flexpro construction company (BID ID -3472656)
ANIL KUMAR GUPTA (BID ID -3472509)
M/S MOHAN KUMAR BANSAL (BID ID -3473475)
R K AGARWAL (BID ID -3473823)
Samir Kumar Dey (BID ID -3473862)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
Tender.pdf
Tender Documents • 1.73 MB
Sch.pdf
Additional Documents • 0.38 MB
BOQ_820080.xls
BOQ • 0.38 MB
Corrigendum.pdf
PDF • 0.51 MB
corrigendum.pdf
PDF • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .