Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | MS FORWARD BUILDERS E 32/10/KKD L1₹32.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹36.6 L+₹3.7 L (11.2%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹66.9 L+₹34.0 L (103.1%)Rejected-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L3 | Rejected-AOC Higher bid value | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to not enlisted in appropriate category |
Tender Value
₹48.9 L
EMD Value
₹97,840
Closing Date
22 Apr 2024, 6:00 pmClosed
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
REPAIR / MAINT OF VARIOUS SUMMER APPLIANCES, COOLING APPLIANCES, AC PLANT AND ALLIED WORKS UNDER GE PANAGARH
2024_MES_647126_1
8909/E8
Open Tender
Air-Conditioner
Item Rate
365 days
PANAGARH
Pls refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹97,840
Yes
15 Jun 2024
19 Mar 2024
30 Apr 2024
19 Mar 2024
22 Apr 2024
3 Apr 2024
Amount
AIR CONDITIONER (Existing Make of AC to be repaired :- LG / VOLTAS / Godrej / Samsung / Lloyyd / Blue Star)
Taking down window type Air Conditioner of 1.0 TR/1.5 TR / 2.0 TR, cleaning completely of cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water and refixing at same location with complete testing, complete all as specified and directed.
Dismantling covers of out-door and in-door units of split type Air Conditioner of capacity 1.0TR/1.5TR/2.0TR, cleaning completely the condenser coil and cooling coil initially with hand blower, spraying with soap water solution and finally clean with clear water, re-fixing the covers in same position, complete all as specified and directed.
Carrying out pressure leak test by Nitrogen gas pressure for detecting leak in condensing unit refrigerant pipe and repairing the leak by welding or brazing of condensing unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging as per existing and and transporting & carrying out T&P required at site for the following capacity of ACs, water coolers, refrigerators & deepfreezers, complete all as specified and directed. (Note : The rate under mentioned items included for transpotation of AC to & from work shop as approved by Engr-in-Charge.)
Window type AC of capacity up to 2.0 TR
Split type AC of capacity up to 2.0 TR
Refrigerator of capacity 175 ltrs to 420 ltr
Water cooler of capacity 40 Ltr to 150 ltrs
Deepfreezer of capacity upto 410 ltrs
Taking out of condensing coil fan motor from the AC unit, dismantling, cutting burnt coils, cleaning and rewinding using provision of new 1st quality super enameled copper wire of existing size and gauge including replacement of bush with new bush (front and rear) made out of gun metal and reassembling all accessories and testing, complete all as specified and directed for the following :-
Window type AC of capacity 1.0 TR/1.5TR/2.0 TR
Split type AC of capacity 1.0 TR/1.5TR/2.0 TR
Water cooler of capacity 40 Ltr to 150 ltrs
Deepfreezer of capacity upto 410 ltrs
Refrigerator of capacity 220 ltrs to 420 ltr
Repair to split / window type AC of defects such as indoor unit water leakage, slow cooling of air conditioner, noisy compressor, corrosion of wire and terminals, adjustment of PCB indicator, electrical control failures, clogged drain water pipe, cleaning the air filters with suitable method, tightening of loose wire, nuts, bolts & washers, oiling, greasing, welding / bracing, setting of grill / alignment & knobs, provision of thermocol for air tightening etc. by opening of AC's & re-fixing to make it fully functional in all respect and handing over the report duly signed by the users by name to concerned JE, complete all as specified and directed. [Note : (a) S&F of spare parts, if any, shall be measured and paid separately under following item Nos. 1.16 to 1.39 . (b) The rate under mentioned items included for transpotation of any type of ACs to & from work shop as approved by Engr-in-Charge.]
S&F Running capacitor 50 mfd
S&F Running Capacitor 4/6 mfd
S&F Coppr capillary Tube as per existing size
S&F Filter strainer
S&F Air filter made of plastic frame and nylon net
S&F indoor unit Temparature censor for split type AC
S&F outdoor unit temparature censor for split type AC
S&F Running capacitor 50 Mfd + 6 Mfd up to 2 ton split type AC
S&F Blower motor for window/Split Type AC upto 2 Ton capacity as per existing
S&F Remote suitable for window/Split AC
S&F Front grill for window AC as per existing
S&F PCB Board for Window/split type AC
S&F PCB Board for Dual type inverter split AC
S&F Rubber bushing for blower motor
S&F Swing motor for split type AC of capacity 1.0 TR/1.5TR/2.0TR
S&F Display assembly for spilit type AC
S&F Sensor for Indoor unit
S&F Copper tube cooling/condensor coil 5/8 inch with proper insulation
S&F Copper tube cooling/condensor coil 1/2 inch with proper insulation
S&F Copper tube cooling/condensor coil 1/4 inch with proper insulation
S&F Fan blade set as per existing
S&F Fan motor 1/5 HP, single phase, 240 volts (as per existing)
S&F Fan capacitor of capacity 3/4/5 mfd, 230 volt, ISI marked
S&F Pencil battery for ACs remotes of size AAA, 1.5 V (Set of two)
Repairing of compressor terminals of any type of ACs including other components of compressor, complete all as specified and directed.
Repairing of PCB board (Componemts like transistor, diode etc) for any type of split/window AC, complete all as specified and directed.
Shifting of split type AC (Indoor/Outdoor unit) any capacity including replacement of MS stand/angle iron breaket/hanger (Set of 2) for outdoor units and electric connection/ pipe line connection (suction and discharge line), testing and fully functional of unit, complete all as specified and directed. (Note : S&F of Spare parts shall be measured and paid separately under appropriate items.)
S&F in repairs sealed unit Compressor rotary type for window/split AC upto 1.5 Ton capacity as per OEM recommended, complete all as specified and directed.
S&F in repairs sealed unit Compressor rotary type for window/split AC upto 2.0 Ton capacity as per OEM recommended, complete all as specified and directed.
S&F in repairs flexible drain pipe for split type AC, complete all as specified and directed.
M&L in repairs wiring kit and connector etc. and replacement of defective wiring of any make by Window/Split AC, complete all as specified and directed.
S&F in repairs for MS stand/angle iron bracket of outdoor unit of split type ACs of 1.5TR/2.0 TR capacity including grouting nuts & bolts on wall/floor for fixing/hanging for out door unit and electric connection/ pipe line connection (suction and discharge line), testing and fully functional of unit, complete all as specified and directed.
M&L for opening/cutting hole in brick/puf wall sutable for window type AC 1.5/2 Ton and making good disturbed surface area complete with cement plaster and masonary work reqd at site and made air tight to opening with the thermocoal material all round the window AC etc., complete all as specified and directed.
S&F in repairs MCB, SP, 240 v, 32 Amps, 'C' series, complete all as specified and directed.
S&F in repairs MCB, SPN 240 v, 32 Amps, 'C' series, complete all as specified and directed.
S&F in repairs copper condensor for split type AC of capacity upto 2.0 TR, complete all as specified and directed. Make : As per existing.
S&F in repairs PVC insulated flexible multistranded copper conductor nominal area 1.5 Sqmm, round type 3 core cable, complete all as specified and directed.
S&F in repairs PVC insulated flexible multistranded copper conductor nominal area 2.5 Sqmm, round type 3 core cable, complete all as specified and directed.
S&F in repairs PVC insulated flexible multistranded copper conductor nominal area 4.0 Sqmm, round type 3 core cable, complete all as specified and directed.
WATER COOLER (Existing Make of Water Cooler to be repaired :- Voltas / Blue Star / Godrej / Lloyyd / Samsung / LG)
Repairs to water cooler 40/80/120 ltr capacity by removing dust with suitable method, cleaning the water tank inlet and outlets including leak proofing / repairing of storage tank, necessary repairs to wiring of the water cooler unit (i.e. internal wiring connection to compressor, condenser motor etc.), supply and replacement of damaged hinges, nuts, bolts clamps, washers, screws, tightening the loose parts, servicing of condenser motor by oiling, greasing, required welding / bracing to the any parts of water cooler, repairs to chromium plated drain tray, replacement of worn out mounting rubber bushes of condenser motor / compressor, setting of thermostat, relay, knobs, checking of any leakage, scrap out rust & dust from body of water cooler, checking the actual fault & make it fully functional in all respect & handing over the report duly signed by the users by name to concerned JE (E/M), complete all as specified and directed. [Note : (a) S&F of Spare parts, if any, shall be measured and paid separately under Item Nos 2.02 to 2.18 . (b) The rate under mentioned items included for transpotation of water cooler to & from work shop as approved by Engr-in-Charge.]
S&F push type tap copper alloy chromium plated 15 mm bore for water cooler
S&F rubber lining for top cover gasket (upto 3 metre long for water cooler
S&F starting relay suitable for 5/8 HP motor for water cooler
S&F starting capacitor 60/80 mfd or 40/60 mfd for water cooler
S&F thermostat, single phase, 240 volts Make : as per existing
S&F float valve of size 15 mm dia, Brass rod with fly nut screwed complete as per existing.
S&F over load protector, single phase, 240 volts
S&F copper Capilary tube as per existing size and length
S&F blower motor, 1 phase, 240 volts as per existing.
S&F running capacitor 15 mfd, 240 volts
S&F running capacitor 10 mfd, 240 volts
S&F fan blade assembly as per existing
S&F drain stainless steel tray with drain elbow and connector as per existing size.
S&F PVC hose connection pipe both ends having brass coupling threaded for 15mm bore
S&F PVC drain hose pipe of size 32mm dia as per existing length (upto 2 metre)
S&F fan motor (copper wound) as per existing capacity upto 150 Ltrs
S&F copper wound compressor upto 1/3 HP or suitable for existing.
REFRIGERATOR (Existing Make of Refrigerator to be repaired :- Blue Star / Godrej / Lloyyd / Samsung / Voltas / LG / Whirlpool)
Repairs to Refrigerator 165/210/215/300/340/420 ltr capacity by removing dust with suitable method, cleaning the water tank inlet and outlets including leak proofing / repairing of storage tank, necessary repairs to wiring of the refrigerator unit (i.e. internal wiring connection to compressor, condenser motor etc.), supply and replacement of damaged hinges, nuts, bolts clamps, washers, screws, tightening the loose parts, servicing of condenser motor by oiling, greasing, required welding / bracing to the any parts of refrigerator, repairs to chromium plated drain tray, replacement of worn out mounting rubber bushes of condenser motor / compressor, setting of thermostat, relay, knobs, checking of any leakage, scrap out rust & dust from body of refrigerator, checking the actual fault & make it fully functional in all respect & handing over the report duly signed by the users by name to concerned JE (E/M), complete all as specified and directed. [Note : (a) S&F Spare parts, if any, shall be measured and paid separately under appropriate items. (b) The rate under mentioned items included for transpotation of refrigerator to & from work shop as approved by Engr-in-Charge.]
S&F copper Condencor coil for upto 340 Ltrs cap
S&F Pin/Thread type lamp holder
S&F bulb LED 2 watt (Pin/Thread type)
S&F PVC moulded Ice tray
S&F Relay with overload protector for 165 to 210 ltr
S&F Thermostat for auto defrost
S&F Capillary tube (copper) as per existing
S&F PVC Chill tray as per existng size upto 420 Ltr capacity
S&F Ice Chamber complete up to 420 Ltr as per existing size
S&F PVC Vegetable box up to 420 Ltr as per existing size
S&F Bimetal with tharmo fuse for double door refrigerator upto 420 Ltr capacity
S&F Frost free fan motor upto 420 ltr capacity
S&F Timer for refrigerator upto 420 Ltr capacity
S&F Relay 1/6 HP as per existing upto 420 Ltr capacity
S&F Over load protector 1/6 HP as per existing
S&F Door megnatic gasket for upto 420 Ltrs capacity
S&F Push type light switch 5 Amps, 240 volts upto 420 Ltrs capacity
S&F cooling coil for upto 420 ltrs capacity as per existing
S&F Fan motor of capacity 1/5 HP 1 phase, 240 Volts Make:-As per existing.
S&F Copper wound compressor as per existing upto 215 Ltrs. Make : As per existing.
S&F Copper wound compressor as per existing upto 300 Ltrs to 420 ltr. Make : As per existing.
S&F PCB board for refrigerator any capacity as per existing.
S&F in repairs for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 Amps 240 volt, complete all as specified and directed.
Supply and charging of refrigerant gas R-22 upto sufficient pressure for compressor of 1.5/2.0 Ton Split/window AC including connected works like pressure testing with nitrogen before filling of refrigerant gas including cutting of copper tubing and brazing & refixing in position, complete all as specified and directed.
Supply and charging of refrigerant gas R-32 upto sufficient pressure for compressor of 1.5/2.0 Ton Split/window AC including connected works like pressure testing with nitrogen before filling of refrigerant gas including cutting of copper tubing and brazing & refixing in position, complete all as specified and directed.
Supply and charging of refrigerant gas R-134A upto sufficient pressure for compressor of water cooler/Deep fridger including connected works like pressure testing with nitrogen before filling of refrigerant gas including cutting of copper tubing and brazing & refixing in position, complete all as specified and directed.
Supply and charging of refrigerant gas R-410 upto sufficient pressure for compressor of 1.5/2.0 Ton Split/window AC including connected works like pressure testing with nitrogen before filling of refrigerant gas including cutting of copper tubing and brazing & refixing in position, complete all as specified and directed.
Supply and charging of refrigerant gas R-600 upto sufficient pressure for compressor of Refrigerator including connected works like pressure testing with nitrogen before filling of refrigerant gas including cutting of copper tubing and brazing & refixing in position, complete all as specified and directed.
Repairs to Voltage stabilizer of any capacity/make, attendending these at site to asses the actual fault after opening of voltage stabillizer including dismantling, servicing and repairing/replacement of worn out spare parts as required (like all cable connections, PVC connector, indicator lamp, cutout, complete parts along with testing commissioning to make it fully functional in all respect including trasportation from site to workshop and back and handing over the report duly signed by the user by name to concern JE for the following capacity, complete all as specified and directed. (Note : S&F of Spare parts, if any, shall be measured and paid separately under Item Nos . 3.35 to 3.43.)
Upto 3 KVA capacity
4 KVA capacity
5 KVA capacity
Replacement of following spare parts for upto 3 KVA capacity stabalizers:-
S&F Relay set (set of two)
S&F PCB ( Printed circuit board)
S&F LED digital display for voltage measured
S&F transformer unit
Replacement of following spare parts for 4 KVA to 5 KVA capacity stabilizers :-
S&F Relay set (set of two)
S&F PCB (Printed circuit board)
S&F LED digital display for voltage measured
S&F transformer unit
WASHING MACHINE
Repairs to washing machine of any capacity/make, attendending these at site to asses the actual fault after opening of washing mecine and fixing only spares as required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE, complete all as specified and directed. [Note : (a) S&F of Spare parts, if any, shall be measured and paid separately under appropriate items. (b) The rate under mentioned items included for transpotation of washing mechine to & from work shop as approved by Engr-in-Charge.]
S&F PCB Board for washing machine of capacity upto 7 Kg.
S&F Electric motor for washing machine of capacity upto 7 Kg.
S&F water pump for washing machine of capacity upto 7 Kg.
S&F water removing pump & motor for washing mechine of capacity upto 7 Kg.
S&F rubber valve with sring and connecting accessories for washing mechine of capacity upto 7 Kg.
DEEP FREEZER (Existing Make of Deep Freezer to be repaired :- Blue Star / Samsung / LG / Voltas)
Repairs to deep freezer of any capacity/make, attendending these at site to asses the actual fault after opening of deep freezer and fixing only spares as required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE, complete all as specified and directed. [Note : (a) S&F of Spare parts, if any, shall be measured and paid separately under Item Nos. 5.02 to 5.07 . (b) The rate under mentioned items included for transpotation of deep freezer to & from work shop as approved by Engr-in-Charge.]
S&F Over load relay as per existing capacity.
S&F Fan motor with blades set 4" size, as per existing.
S&F Fan motor with blades set 6" size, as per existing.
S&F Thermostate as per existing cpacity.
S&F Filter (Stainer) as per existing capaity.
S&F Copper wound compressor 1/3 HP or as per existing upto 300 Ltrs.
GEYSER (Existing Make of Geyser to be repaired :- Bajaj / Havellls / Crompton Greaves)
Repairs to Geyser of 50/25 lrs capacity, attendending these at site to asses the actual fault after opening of Geyser including taking down and dismantling, servicing and fixing of worn out spare parts as required including testing to make it fully functional in all respect including trasportation from site to workshop and back icluding fixing its existing position and handing over the report duly signed by the user by name to concern JE, complete all as specified and directed. (Note : S&F of Spare parts, if any, shall be measured and paid separately under Item Nos. 6.02 to 6.13 .)
S&F apparatus plate match to the existing one with rubber gasket suitable for 25/50 ltrs geyser, complete all as specified and directed.
S&F steel inner container (As per sample) for 25 ltrs geyser including rubber gasket, complete all as specified and directed.
S&F puf insulation suitable for geyser, complete all as specified and directed.
S&F heating element triangular type of 1.5/2.0 kw 230 volt including connecion and testing, complete all as specified and directed.
S&F heating element round type of 1.5/2.0 kw 230 volt including connecion and testing, complete all as specified and directed.
S&F thermostat with reseter short type matching to exist one including all connection, testing etc., complete all as specified and directed.
S&F thermostat with reseter long type matching to exist one including all connection, testing etc., complete all as specified and directed.
S&F PVC Connection pipe steel wire braided 15 mm dia, 450 mm long (one pair, i.e. 02 Nos) with two Nos brass chromium plated union alongwith Hexagonal nuts adoptor, rubber washer etc., complete all as specified and directed.
S&F PVC Connection pipe steel wire braided 15 mm dia, 600 mm long (one pair, i.e. 02 Nos) with two Nos brass chromium plated union alongwith Hexagonal nuts adoptor, rubber washer etc., complete all as specified and directed.
S&F metal safety valve or as per existing for geysers, complete all as specified and directed.
S&F LED indicators lamp Red (As per sample), round / rectangular type, complete all as specified and directed.
S&F LED indicators lamp Green (As per sample), round / rectangular type, complete all as specified and directed.
S&F in repairs stop valve cast copper chromium plated, high pressure capstan head suitable for 15 mm bore, complete all as specified and directed.
S&F in repairs MS clamp with anchor nut, bolt, washer (As per sample) including drilling for geyser, complete all as specified and directed.
M&L for paiting of rusted geyser including scraping, brushing down old paint by emery paper and apply two coats of white synthtic enamal paint using spray machine incluing writing SM/MES No on geyser by black synthetic enamal pant, complete all as specified and directed.
Shifting including fixing at any location of Geyser 25 ltr capacity includng set of anchor nuts & bolts, complete all as specified and directed.
S&F in repairs wiring for circuit/submain wiring including earth wire with the following size of FRLSH PVC insulated copper conductor, single core cable in surface as required 2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire with & including suitable size of PVC casing caping / conduit, complete all as specified and directed. (Note : Two run plus one run of cable and PVC casing caping / conduit considered as One RM.)
S&F in repairs wiring for circuit/submain wiring including earth wire with the following size of FRLSH PVC insulated copper conductor, single core cable in surface as required 2 x 4.0 sqmm + 1 x 4.0 sqmm earth wire with & including suitable size of PVC casing caping / conduit, complete all as specified and directed. (Note : Two run plus one run of cable and PVC Casing caping / conduit considered as One RM.)
S&F in repairs switch socket combination 5 in 1, 6 pin, (5/16 Amps) flush type 240V controlled by one switch, complete all as specified and directed.
S&F in repairs of plug top 5 Amps capacity, 3 pin, 240 volts, complete all as specified and directed.
S&F in repairs of Plug top 15 Amps capacity, 3 pin, 240 volts, complete all as specified and directed.
CENTRAL TYPE AC PLANT 50 TR CAPACITY (3 x 25 TR) (Existing Make of Plant to be repaired :- VOLTAS)
M&L for preventive and comprehensive maintenance of Central AC Chiller Plant of Capacity 3 x 25 TR strictly through OEM i.e. M/s Voltas for the plant and equipment of Model No. ACWCDSQ26DPMN 2 X 1P 25. The scope of work is as under :- (a) Checking and rectification if required for abnormal noise, vibration, leakage of refrigerant, oil etc. (b) Topping up of system with refrigerant and oil replace dehydrators etc. (c) Checking of operation of oil heater, motor protector, flow switch, loading unloading etc. (d) Checking of control valve. (e) Attend breakdown calls as and when required, investigation of system, locate defect and rectify the same as soon as posible. (f) All the maintenance /servicing work should be done in such a way so that the equipment /unit can be used for its optimum performance. (g) Adjustment in the system to achive required temprature and RH level. (h) Cleaning of all type of air filter. (l) Cleaning of diffuser, grills, damper etc if required. (m) Servicing, cleanning of evaporators, expansion valve, water cooled condenser, oil cooler, oil pipe, oil filter, refrigerant piping, refrigerant filter & solenoid valve etc.
Notes for Item No. 7.01 : (a) Scope of work also include supply of material like timer, chiller in/out sensor, filter drier and solenoid coil during AMC. (b) Comprehensive maintenance is to be carried out by OEM i.e. M/s Voltas only. The contractor has submit MOU of the plant from OEM and it will be essential requirement and will be submitted to GE / Engr-in-Charge before execution of work. Necessary fitness certificate after maintenance to be produced by contractor from OEM for claiming the payment. (c) Quoted rate deemed to be included for 3 x 25 TR capacity plant complete system is considered one job. (d) Job will be done every three month apart upto cmpletion of CA prevision and If any defect has occurred within the period, the contractor shall be responsible to redone job with own cost.
Taking out electric driven induction motor of capacity 3 HP/2.25 KW for cooling tower with disconnecting all electric connection and transporting to workshop for repair including servicing of motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including greasing, oiling reassembling, transporting upto site, re-installaion and testing & painting of the motor including replacement of following worn-out parts like bearings, connector etc., complete all as specified and directed.
Taking out electric driven induction motor of capacity 20 HP/15 KW for chilled water with disconnecting all electric connection and transporting to workshop for repair including servicing of motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including greasing, oiling reassembling, transporting upto site, re-installaion and testing & painting of the motor including replacement of following worn-out parts like bearings, connector etc., complete all as specified and directed.
Taking out electric driven induction motor of capacity 10 HP/7.5 KW for condenser water with disconnecting all electric connection and transporting to workshop for repair including servicing of motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including gressing, oiling reassembling, transporting upto site, re-installaion and testing & painting of the motor including replacement of following worn-out parts like bearings, connector etc., complete all as specified and directed.
Taking out electric driven induction motor of capacity 15 HP/11 KW for hot water with disconnecting all electric connection and transporting to workshop for repair including servicing of motor, re-winding of burn motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including greasing, oiling reassembling, transporting upto site, re-installaion and testing & painting of the motor including replacement of following worn-out parts like bearings, connector etc., complete all as specified and directed.
Taking down defective condensor water pump of suction/delivery 80/65 mm, head 25m capacity, coupled with motor cap 10HP, 1450 rpm, after disconnecting all mechanical & electrical Connections, cleaning all parts incl impeller including replacement of worm out parts like bush/bearing, gland packing, greasing and servicing/overhauling etc. complete and installed the same incl testing, complete all as specified and directed. (Note : The rate under mentioned items included for transpotation of pump set from site to work shop and back at site.)
Taking down Defective Chiller water pump of suction/delivery 80/65 mm, head 25m capacity, coupled with motor cap 20 HP, 1450 rpm, after disconnecting all mechanical & electrical Connections, cleaning all parts incl impeller including replacement of worn out parts like bush/bearing, gland packing, greasing and servicing/overhauling etc. complete and installed the same incl testing, complete all as specified and directed. (Note : The rate under mentioned items included for transpotation of pump set from site to work shop and back at site.)
Taking down Defective hot water pump of suction/delivery 80/65 mm, head 25m capacity, coupled with motor cap 15 HP, 1450 rpm, after disconnecting all mechanical & electrical Connections, cleaning all parts incl impeller including replacement of worn out parts like bush/bearing, gland packing, greasing and servicing/overhauling etc. complete and installed the same incl testing, complete all as specified and directed. (Note : The rate under mentioned items included for transpotation of pump set from site to work shop and back at site.)
Taking down Defective cooling tower water pump of suction/delivery 25/40 mm, head 25m capacity, coupled with motor cap 3 HP, 1450 rpm, after disconnecting all mechanical & electrical Connections, cleaning all parts incl impeller including replacement of worn out parts like bush/bearing, gland packing, greasing and servicing/overhauling etc. complete and installed the same incl testing, complete all as specified and directed. (Note : The rate under mentioned items included for transpotation of pump set from site to work shop and back at site.)
Comprehensive maintenance including servicing of indoor type panel for chiller units of AC plant, replacement of any worn out items (i.e.same size of copper conductor for wiring, fuses, any capacity contractor, 4 pole MCB, SMPS, CT, Connectors, lugs etc. if reqd.) including testing to make it fully functional in all respect, complete all as specified and directed. [Note : (a) Spare sparts shall be measured and paid seperately as S&F only under respective items of BOQ. (b) Wiring for copper conductor, Lugs, connector etc are deemed to be included in quoted rate. (c) Comprehensive maintenance is to be carried out by OEM i.e. M/s Voltas only. The contractor has submit MOU of the plant from OEM and it will be essential requirement and will be submitted to GE / Engr-in-Charge before execution of work. Necessary fitness certificate after maintenance to be produced by contractor from OEM for claiming the payment.]
S&F in repairs fuses as per OEM recommended.
S&F in repairs contractor as per OEM recommended.
S&F in repairs SMPS (Input 100 to 270 volts & output DC 24 volts) as per OEM recommended.
S&F in repairs MCB 4pole 63 Amps, 415 Volts, 'C' series comlete all as specified and directed.
S&F in repairs CT (As per sample), ratio 100/5 /200/5 amps complete all as specified and directed.
S&F in repairs Contactor TP, AC3, type MNX 32 as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs Contactor TP, AC3, type MNX 25 as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs Contactor TP, AC3, type MNX 9 as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs Contactor TP, AC3, type MNX 12 as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs thermal over load relay 9 to 14 A as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs thermal over load relay 4 to 6.5 A as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs thermal over load relay 2.5 to 4 A as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs timer, 240 volt, 50 Hz, AC as approved and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs PVC Cooling tower fills of size (600 x 300 x 150)mm, sheet thickness 0.2-1.0 mm of colour blue/green as approved and suitable for CENTRAL AC PLANT Cooling tower, complete all as specified and directed.
S&F in repairs MCCB, 4P, 630 Amps, 36 KA, thermal magnetic release and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs MCCB, 4P, 100 Amps, 16 KA, thermal magnetic release and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
Taking out unserviceable digital Ammeter, supply & fixing digital Ammeter of similar range of size 96mmx96mm", 3 phase, 415 volt, AC, suitable for the LT Panel board including electrical connection with suitable size of copper wire, complete all as specified and directed.
Taking out unserviceable digital Voltmeter, supply & fixing digital Voltmeter of similar range of size 96mmx96mm", 3 phase, 415 volt, AC, suitable for the LT Panel board including electrical connection with suitable size of copper wire, complete all as specified and directed.
S&F in repairs push button (start-stop) switch and suitable for LT Panel of Central AC Plant, complete all as specified and directed.
S&F in repairs MCB SP 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection, complete all as specified and directed.
S&F in repairs MCCB, 3P, 63 Amps, 16 KA, thermal magnetic release and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
S&F in repairs MCCB, 3P, 16 Amps, 16 KA, thermal magnetic release and suitable for LT Panel of CENTRAL AC PLANT, complete all as specified and directed.
Dismantling, cleaning, Overhauling, servicing and maintenance of AHU unit including cleanning of filters after disconnecting all mechanical & electrical Connections etc. and testing, complete all as specified and directed.
S&F in repairs Rotary switch with handles, 100 Amps, 415 volts, open execution type TPN suitable for DIN fuse link, complete all as specified and directed.
S&F in repairs Rotary switch with handles, 63 Amps, 415 volts, open execution type TPN suitable for DIN fuse link, complete all as specified and directed.
S&F in repairs of butterfly valve of size 100 mm dia, complete all as specified and directed.
S&F in repairs of filter stainer (Refrigerent line) as per suitable to existing line OEM recommanded, complete all as specified and directed.
S&F in repairs of HP / LP cut out as per existing capacity, complete all as specified and directed.
S&F in repairs of water pressure gauge of existing range, complete all as specified and directed.
Descaling for AC Plant (each unit ie 1 x 25 TR) of copper tube and pipe line of cooling coil as per site requirement, complete all as specified and directed.
Descaling AC Plant (each unit ie 1 x 25 TR) of copper tube and pipe line of condensing coil as per site requirement, complete all as specified and directed.
Supply, installation, testing and commissioning in repairs of digital display controller with thermister sensor for main chiller unit panel (Model: TM172PDG28R of make Schnerder or Equivelent Model/make) as per existing and required to make it fully functional in all respect, complete all as specified and directed. (Note : To Produce company original test certificate before payment as per approved make.)
Supply, installation, testing and commissioning in repairs of scroll compressor (Model: SZ185S4RC of make Denfoss or Equivelent Model/make) as per existng, 3 Phase, 415 Volts and required to make it fully functional in all respect, complete all as specified and directed. (Note : To Produce company original test certificate before payment as per approved make.)
M&L for disconnecting of electric connection and mechanical items of existing compressor including inlet or outlet copper pipes by cutting/brazing and rimming etc for rectification of faults of compressor by carrying out compressor pressure test/leakage test and its efficiency. After carrying out compression test, the necessary repair / overhauling of compressor as per OEM recommandation and reinstallation of compressor as per existing one including vaccuming of entire system , connection of electric connection, mechanical items of existing compressor including inlet or outlet copper pipes. After completion of connection filling of refrigerent gas (R-407C) in required qty, complete all as specified and directed. [Note : Refrigerent gas (R-407C) shall be paid separately.]
M&L Nitrogen gas pressure testing by pressurising upto 300 psi of the complete system of each unit (1 x 25 TR) to find out the leakage & maintaining pressure for required time and rectifying leakages in the system, vaccumising complete system of central A/C plant with double stage vaccum pump of 2kg/Sq cm vaccum pressure, complete all as specified and directed.
M&L for charging refrigeration gas R-407C for central AC plant for commissioning, complete all as specified and directed.
Repairs, inspecton, servcing, repairing, replacement in repairs worn out following spare parts as per existing (like MCB TP, LED Indicator light with holder, fuses unit, CTs,LED display, Push switch, ON/OFF switch etc) of hot water generator panel including internal wiring, and required to make it fully functional in all respect complete, complete all as specified and directed. (Note : S&F of Spare sparts, if any, shall be measured and paid seperately under Item No. 7.51 to 7.56 .)
S&F MCB TP 63 Amops, 415 volts.
S&F LED Indicater light with holder complete.
S&F CT (As per sample), ratio 100/5 amps.
S&F LED display as per OEM recommandation.
S&F Push switch for panel.
S&F ON/OFF switch for panel.
M&L in repairs for inspecton, servcing, repairing repacement of worm out spare sparts as per existing item of AHU panel and required to make it fully functional in all respect, complete all as specified and directed.
Supply, installation, testing and commissioning in repairs of AHU Room LED Display unit as per existng and required to make it fully functional in all respect, complete all as specified and directed.
Supply, installation, testing and commissioning in repairs of AC Plant room LED Display unit as per existng and required to make it fully functional in all respect, complete all as specified and directed.
Supply, installation, testing and commissioning in repairs of Temp & RH LED indicator as per existng for AC Plant and required to make it fully functional in all respect, complete all as specified and directed.
M/S BISWAS AND KUNDU CONSTRUCTION
M/S Ali Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .