Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹38.7 L+₹7,100 (0.18%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹43.4 L+₹4.8 L (12.4%)Rejected-AOC | L3 | Rejected-AOC OK |
Tender Value
₹45.9 L
EMD Value
₹92,000
Closing Date
13 May 2020, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR MAINT TO LT PANELS AND SWITCH GEARS OF ELECTRIC INSTALLATION AND CONNECTED WORKS UNDER GE WEST BAREILLY
2020_MES_314989_2
8789/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
SCANNED COPY OF ENLISTMENT LETTER IN MES IN RELEVANT CLASS CATEGORYSCANNED COPY OF APPLICATION ON LETTER HEAD OF FIRM
SCAN COPY OF DD OF RS 500.00 IN FAVOUR OF GE WEST BAREILLY FROM ANY NATIONALISED OR SCHEDULED BANK SCANNED COPY OF REGISTRATION
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹92,000
Yes
2 Jun 2020
22 Apr 2020
18 May 2020
22 Apr 2020
13 May 2020
30 Apr 2020
22 Apr 2020 - 30 Apr 2020
Amount
Maintenance and complete overhauling of L.T , Oil circuit breaker of existing make/ type/model/capacity including disassembling of operating mechanism parts, well cleaning with petrol and CRC-226 and replacing unserviceable parts, and accessories, oiling / greasing of moving parts includng reassembling fine setting of mechanism removing of oil tank well cleaning and decarbonization of arc control pot fixed and moving contacts ,hinges contacts and repacement of unserviceable parts insulating oil and reassembling and making OCB in perfect operation in manual and electrical mode including well cleaning the complete panel board, main busbar, carbonizing all joints,busbar CTs, metal parts and checking of tripping system of L.T circuit breaker . Note:- Spare parts required to make OCB functional will be measure and paid separately under respective items.
LED type indicator lamp assembly Red colour
LED type indicator lamp assembly yellow colour
LED type indicator lamp assembly blue colour
Moving Contact as per existing size
Fixed Contact block Assly as per existing size.
Tripping coil
Bushing with complete set of stud
Finger as per existing
Ampere meter analog as per existing ratio
Bakalite sheet for bushing
M & L fabrication of MS busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6mm dixed on porcelain insulators TPN type out door weather/vermin proof with both way opening duly provided with neoprene rubber gasket along the doors openings pedestal type duly painted powder coated on CRCA steel sheet encloser 3.15mm thick with one No incommer MCCB 250 Amp 35 KA complete all as sepcified and directed incl making connection /thimbles etc complete.
All as per srl item No 02 here-in-before but of size 600 mm x 600 mm x 400 mm and without MCCB
M&L for preparing old painted surface of panel board by cleaning removing of the old paint by scrathing with wire brush/sand paper etc and including denting/patching of broken/rusted surfaces etc and apply two coat of synthetic enamel paint by spray painting on inside/outside surface of panel,all as specified and directed by Engr-in- charge.
M&L for fabrication of door/surfaces of LT panel indoor/outdoor as per existing size / thickness/shape and fitted in the panel with door handle, formed gasket around doors, lock insets, earthing strips, door stay, hinges etc. including two coat of synthetic enamel paint by spray painting on inside/outside surface of panel,all as specified and directed by Engr-in- charge.
Repair to LT panel of any size in different location with arc/gas welding with replacement of hinges and place the door in original position, replacement of door locks and replacement of indicator lamp (1 set) etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in replacement copper bus bar in the panel of existing size and capacity for phase and neutral with heat shrinkable including PVCsleeves in different colour codes for phase indication all as per directed by Engr-in-charge
All as per item No 7 Above but aluminium bus bar
S & F in replacement LED type phase indication lamp of Red /blue/Green colour for phase indication in existing panels complete all as specified and directed by Engr-in-charge
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x60cmx6mm thick burried directly in ground vertically ( to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x 6 mm size with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 3 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and dirfected by Engineer-in-charge
Taking down u/s MCCB 4 pole 630 Amp 415 Volt and S & F in replacement MCCB 415 Volts 4 pole 630 Amps 50 Hz 50 KA of existing make model and type alongwith spreader terminal with adjustable thermal setting including lugs/thimbles of suitable size in existing panels complete all as specified and directed by Engr-in-Charge Note : Necessary addition /altration required to adjust MCCB in the panel shall be done by the contractor and no extra payment will be made to the contractor
All as per Item No.12 above but of MCCB 500 Amps 4 pole 50 Hz 415 V with rupturing capacity 50 KA
All as per Item No.12 above but of MCCB 400 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA
All as per Item No.12 above but of MCCB 315 Amps 4 pole 50 Hz 415 V with rupturing capacity 36 KA
All as per Item No.12 above but of MCCB 250 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA
All as per Item No.12 above but of MCCB 200 Amps 4 pole 50 Hz 415 V with rupturing capacity 25 KA
All as per Item No.12 above but of MCCB 125 Amps 4 pole 50 Hz 415 V with rupturing capacity 16 KA
All as per Item No.12 above but of MCCB 100 Amps 4 pole 50 Hz 415 V with rupturing capacity 16 KA
Taking down u/s MCB TPN 63 Amp and S&F in repair, MCBs triple Pole and neutral 63 Amp, 415 Volts 10 KA complete all as specified and directed by Engineer-in-charge
Taking down u/s MCB TPN 100 Amp and S&F in repair, MCBs triple Pole and neutral 100 Amp, 415 Volts 10 KA complete all as specified and directed by Engineer-in-charge
Taking down u/s MCB SPN 32 to 40 Amp and S&F in repair, MCBs single Pole and neutral 32 to 40 Amp, 230 Volts 10 KA complete all as specified and directed by Engineer-in-charge
Taking down and S&F in repair off load change over switch three phase, Four pole with enclosure capacity 100 Amps with side handle operated complete all as specified and directed by Engineer-in-charge
ditto ----- all as per item No. 23 above but 125 Amps
ditto ----- all as per item No. 23 above but 160 Amps
ditto ----- all as per item No. 23 above but 200 Amps
ditto ----- all as per item No. 23 above but 250 Amps
ditto ----- all as per item No. 23 above but 315 Amps
S&F in repair on load change over switch three phase, Four pole capacity 100 Amps with front handle operated complete all as specified and directed by Engineer-in-charge
ditto ----- all as per item No. 29 above but 125 Amps
ditto ----- all as per item No. 29 above but 200 Amps
ditto ----- all as per item No. 29 above but 250 Amps
Dismantalling of old unsv LT feeder pillar box after disconnecting of all electrical connection and good disturbed surfaces with clearing the site
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 2000 x 2000 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA steel sheet including duly painted powder coated and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel.Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-Location: FAFA QTRS
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 500 Amp 50KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As Incoming) – 01 No.
MCCB 100 Amp 16KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 08 Nos.
LED Indicating lamp assembly R,Y,B Phase – 06 Set
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 2000 x 2000 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel.Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-Location: supply depot
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 315 Amp 35KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As Incoming) – 01 No.
MCCB 100 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 06 Nos.
MCB SPN 63 Amp 10 KA-01 Nos
MCB SPN 32 Amp 10 KA-04 Nos
LED Indicating lamp assembly R,Y,B Phase – 06 Set
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 2000 x 2000 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel.Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-Location: PH No.32
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 400 Amp 35KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As Incoming) – 01 No.
MCCB 250 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos.
MCCB 100 Amp 16KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos.
LED Indicating lamp assembly R,Y,B Phase – 06 Set
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 2000 x 2000 x 2000mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel. Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-Location: PH No.12
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 400 Amp 35KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As Incoming) – 01 No.
MCCB 250 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos.
MCCB 200 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos.
MCCB 100 Amp 16KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 01 Nos.
LED Indicating lamp assembly R,Y,B Phase – 06 Set
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 2000 x 2000 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel. Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-Location: JLA Cook house
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 250 Amp 35KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As Incoming) – 01 No.
MCCB 200 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 01 Nos.
MCCB 100 Amp 16KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos.
LED Indicating lamp assembly R,Y,B Phase – 06 Set
Supply,installing,commissioning and testing of LT feeder pillar outdoor type of size 1500 x 1200 x 450mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thickCRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel. Including dismantling/ disconnection of old rusted LT panels with accessories. The drawing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-Location: JLA Near Mandir
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 400 Amp 35KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As Incoming) – 01 No.
MCCB 250 Amp 25KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 02 Nos.
MCCB 100 Amp 16KA, 4 pole, 415 volts 50 Hz adj thermal & magnetic setting (As out going) – 01 Nos.
LED Indicating lamp assembly R,Y,B Phase – 06 Set
Supply and installing commissioning and testing of LT feeder pillar outdoor type of size 2000 x 2000 x 600mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel.Including dismantling/ disconnection of old rusted LT panels with accessories. The draing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-Location : Fafa qtrs
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 315 Amp 35KA, 4 pole, 415 volts 50 Hz fixed thermal & magnetic setting (As in comming) – 01 Nos.
MCCB 100 Amp ,4 pole, 415 volts (As out going)-06 Nos
LED Indicating lamp assembly R,Y,B Phase – 01 Set
Supply and installing commissioning and testing of LT feeder pillar outdoor type of size 1500 x 1000 x 450mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 50x50x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted oxide and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel.Including dismantling/ disconnection of old rusted LT panels with accessories. The draing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-JRC MAP
Insulated epoxy coated high conductivity aluminium bus bar 630 Amps (Size 60mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 315 Amp 35KA, 4 pole, 415 volts 50 Hz fixed thermal & magnetic setting (As in comming) – 01 Nos.
MCCB 100 Amp ,4 pole, 415 volts 16 KA (As out going)-07 Nos
LED Indicating lamp assembly R,Y,B Phase – 01 Set
Supply and installing commissioning and testing of LT feeder pillar outdoor type of size 1200 x 1000 x 450mm CPRI certified factory made cubical type weather and vermin proof fixed on and including ventilation and louvers arrangement PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundation of required/suitable size and as directed at site with angle iron frame of size 40x40x6mm, 3 phase 4 wire 415 volts 50 HZ fabricated out of 3.15 mm thick CRCA sheet steel including duly powder coated painted and keeping adequate working space inside of the box (outer width of the box not less than 45cm and gap between bus bar not less than one inch) and double door handle including locking arrangement wih 1 No pad lock of 65mm as directed before manufacturing the panel.Including dismantling/ disconnection of old rusted LT panels with accessories. The draing of the feeder pillar box will be approved by Engr-in-Charge and the same have the following electric controls :-JRC MAP street light
Insulated epoxy coated high conductivity aluminium bus bar 400 Amps (Size 50mmx6mm thick) for phase and neutral complete all as specified and directed.
MCCB 250 Amp 35KA, 4 pole, 415 volts 50 Hz fixed thermal & magnetic setting (As in comming) – 01 Nos.
MCB TPN 100 Amp ,4 pole, 415 volts (As out going)-12 Nos
LED Indicating lamp assembly R,Y,B Phase – 01 Set
Clearing away all grass vegetation ,saplings, shrubs, brush wood undergrowth roots and trees not exceeding 30 CM girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance soft/loose soil and getting out complete all as specified.
M&L Repairs & overhauling to LT ACBs of any capacity(400 A to 2000 A) of any make by removing out the breaker from the respective panels after taking proper electric shut down & disconnecting the breaker, checking it thoroughly for the defects & tripping system of the ACB and rectifing them, lubrication of moving contacts, overhauling of the ACB, replacement of wornout minor spares like springs, washers, levers, nuts & bolts etc reassembling , re-installation ,testing & commissioning of ACB complete all as directed by Engineer-in- charge
Note :Cost of lubricants, cleaning agents, testing tools and minor spares shall be deemed to be including in quoted rates
Supply and fixing of Moving Arcing contacts and adjust the contact pressure of LT ACB of any make any capacity
Supply and fixing of fixed Arcing contact and adjust the contact pressure of LT ACB of any make any capacity
M&L for replacement of main shaft assembly with crank & cam spacer of 1250 Amps 3 pole LT ACB of existing make & model and testing for proper operation complete all as directed by Engineer-in-charge
M&L for replacement of main shaft assembly with crank & cam spacer of 800 Amps 3 pole LT ACB of existing make & model and testing for proper operation complete all as directed by Engineer-in-charge
M&L for replacement of Trip coil of LT ACB of any make any capacity all as specified and directed by Engr-in-charge
Supply and fixing Air break gang operated triple pole mechnically operated mounted on HT insulators and galvanised steel frame with operating rod of 25 mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt , 50 HZ supply incl 12 insulator and drop out fuse carrier element.
M&L for servicing and greasing GOD (gang operated air break switch) 200 Amps triple pole 11 KV including replacement of the following U/S parts :-
ACSR Jumper with RYB, PVC sleaves 1.5 m to 2.0 m long – 03 Nos
Brass connector brackets with bolts, nuts etc - 3 sets
Copper lugs of suitable size
Supply and spreading 20mm stone aggregate for loose filling in sub station around structure, two pole, four pole complete all as specified & directed.
Notes:-
M/S HINA ELECTRICALS
The Electrical Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .