Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94.5 LAccepted-AOC | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹10.7 L+₹70,939.50 (7.07%)Rejected-AOC | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹12.2 L+₹2.1 L (21.3%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹16.0 L+₹5.9 L (59.0%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L4 | Rejected-AOC Quoted L4 |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
23 Aug 2021, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
REPAIR TO ELECTRICAL WIRING AND FITTING INCLUDING GEYSER ETC, EARTHING INFRASTRUCTURE AND ALLIED WORKS AT AF STN HIGHGROUND UNDER GE (AF) CHANDIGARH
2021_MES_462904_1
GE (AF)/CHD/T-20/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
High Ground
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹29,800
Yes
19 Dec 2021
26 Jul 2021
25 Aug 2021
26 Jul 2021
23 Aug 2021
9 Aug 2021
26 Jul 2021 - 2 Aug 2021
Amount
Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in and including 20mm dia nonmetallic rigid PVC conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. NOTE: (a).The quoted rates includes the cutting chasis for conduit and sunken boxes.
All as per item No.2 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2 here-in-before but point wiring for one 5Amps socket outlet point on d same board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No.2 here-in-before but point wiring using 4sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Point wiring PVC insulated unsheathed multistranded copper conductor FR cable using two single core 1.5 Sq.mm (nominal area) in the existing conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified.
All as per item No. 7 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 7 here-in-before but point wiring for one 5Amps socket outlet point on d same board controlled by one single pole, one way switch complete all as specified.
All as per item No. 7 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push complete all as specified.
All as per item No. 7 here-in-before but point wiring for one light point controlled by two single pole, two ways switch complete all as specified.
All as per item No. 7 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 7 here-in-before but point wiring using 4sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
S & F Switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified.
S & F Switch Bell push, flush type, single pole, one way,, 230volts complete all as specified.
S & F Switch piano, flush type, single pole, two way, 5 Amp 230voltscomplete all as specified.
S & F Switch piano, flush type, single pole, one way, 15 Amp 230volts complete all as specified.
S & F Socket outlet multipurpose 3 pin, 5 Amp and 2 pin 5 Amp, flush type, complete all as specified.
S & F Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified.
S & F Ceiling rose, two to three terminals, PVC/ isolated body, complete all as specified.
S & F Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified.
S & F Fan regulator electronic, socket type, suitable for 1200mm /1400mm sweep ceiling fan, with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified.
Supply and fixing Sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp ‘B’ curve, 10 kA, including taking out old unserviceable complete all as specified.
Supply and fixing Sheet metal enclosure (DB) single phase & neutral, double door 4 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
All as per item No. 24 here-in-before but DB 8waycomplete all as specified.
All as per item No. 24 here-in-before but DB 12waycomplete all as specified.
Supply and fixing Sheet metal distribution board TPN, with double door,4 way, 415 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
All as per item No.27 here-in-before but DB 8waycomplete all as specified.
S & F MCB DB, TP & N, vertical Loadline, 8 ways, double door, with provision for MCCB, having IP-43 protection complete all as specified.
S & F MCCB, TP, 100 Amps, 415 Volt, having breaking capacity 10 kA, fixed thermal & fixed magnetic setting, Ics=100% of Icu including taking down old MCCB complete all as specified.
S & F MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
S & F MCB 32/40 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
S & F MCB 32/ 40 Amp, 230 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
S & F MCB 6 to 32/40 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
M & L sub main wiring with 2 runs of 2.5 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor including PVC casing & caping of suitable size and provision of one run 1.5 sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete all as specified. Note :- 2 Runs of 2.5 Sqmm wire and one run of 1.5 Sqmm with PVC casing & caping shall be measured as one unit .
M & L sub main wiring with 2 runs of 4 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor including PVC casing & caping of suitable size and provision of one run 2.5 sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete all as specified. Note :- 2 Runs of 4 Sqmm wire and one run of 2.5 Sqmm with PVC casing & caping shall be measured as one unit .
M & L Sub main wiring with two single core 10.0 Sq.mm (nominal area) PVC insulated and unsheathed cables with stranded copper FR conductor in existing conduit including one run of continuous PVC insulated FR copper stranded cable of wiring size 6.0 Sq.mm for earth continuity , connected to earth dolly inclusive of all accessories complete all as specified. Notes :- (i) 2 runs of 10 Sq.mm main cable + 1 run of 6.0 Sq.mm earth cable considered as 1 Running Metre.
All as per item No. 37 here-in-before but using 2 single 6Sqmm as main & 1 single core 4Sqmm as earth wire complete all as specified.
All as per item No. 37 here-in-before but using 2 single 4Sqmm as main & 1 single core 2.5Sqmm as earth wire complete all as specified.
All as per item No. 37 here-in-before but using 2 single 2.5Sqmm as main & 1 single core 1.5Sqmm as earth wire complete all as specified.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 3mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI wire 4mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 5 of SSR-2009 (Part-I).
Taking up / down water heater (Geyser) of capacity 50/35/25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connection and hot and cold water connection, and including transportation to the contractor 's workshop/at site for repair and vice - versa, , general cleaning/overhauling, cleaning and discaling the tank and assembly with suitable detergent and making fully serviceable and fixing back in same location / position or new location all as directed. Note :- (a) Repairing of any parts except the work mentioned in item will be maasured and paid seperatelly. (b) Replacement of any un serviceable parts required for making the geyser serviceable will be measured and paid seperatelly under "supply only" No extra payment will be allowed for replacing these items, as the same is deemed to be included in relevant item
Supply only Stainless steel inner tank suitable for 25 ltrs Geyser of any make / shape /holes for fixing geyser assembly.
All as per item No 43 herein before but for 35 ltrs.
All as per item No 43 herein before but for 50 ltrs.
Supply only bottom base assembly of copper 9/8 holes type suitable for 35/25 ltrs capacity geyser all as directed.
All as per item No 46 here-in- before but for 50 ltrs capacity geyser .
Supply only heating element 1000/1500/2000 watts capacity of any shape /type with rubber gasket . Make :- Ditz, Dass pass
Supply only heating element 3000W suitable for solar water geyser all as specified and directed by engineer in charge
Supply only Thermostat suitable to adjust the temperature from 0º C to 80º C all as directed. Make :- Ditz, Dass Pass
Supply only Neon indicator lamp of any shape / size / colour all as directed.
Supply only PVC insulated, sheathed 3 core flexible cable of size 2.5Sqmm all as directed.
Supply only Safety plug any type.
Supply & fixing non return valve 15mm bore cast copper alloy suitablwe for geyser complete all as specified and as direceted
Supply only Rubber gasket of thickness 5 mm for geyser assembly of 08 holes / 09 holes all as specified.
Supply only Bottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape all as directed.
Supply anly 3 pin plug top 15 Amps, bakelite suitable for 230/240 volts AC supply all as directed.
Supply only Outer MS sheet complete including top and bottom suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG all as directed.
Supply only CP connection 15mm bore 450mm long in any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as directed .
M/L for spray painting of geyser outer body of any make / size by applying one coat of synthetic enamel white paint over the existing paint including cleaning and preparation of surfac complete all as specified
Disconnecting & taking down complete ceiling fan with blade of any make 1200 mm / 1400 mm sweep from fan hook/ fan box, transporting to local workshop/contractors godown , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s providing paper insulation (cuff / strip type) replacing u/s / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts , bolts, earthing , screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running and connecting cable and depositing in E/M yard complete all as directed by Engr in charge Note: Bush, bearing, capacitor, and canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid for separately.
Supply only capacitor 2.50 MFD, 230 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only capacitor 3.15 MFD, 230 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed.
Supply only bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only PVC Canopy suitable for ceiling fan of 1200 / 1400 mm sweep set of two complete all as directed.
Supply only PVC insulated flexible 3 core, 1.5 sqmm size copper conductor cable of size 1.5 sqmm copper conductor including taking out the old unserviceable PVC flexible wire complete all as specified all as specified and directed by Engineer in Charge.
Supply & fixing for Mild Steel Down Rod of suitable dia , 45 Cms long white or coloured, compatible to existing ceiling fans of 1200mm or 1400 mm sweep including taking out old unserviceable down rod from the fan complete all as specified and as directed by the Engineer–in-charge. Down-Rod shall be of make of existing fan or as approved by the GE.
Disconnecting and taking down ceiling fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of minor parts such as washer, split pins/ blade screw etc and defective parts, if any, and refixing the ceiling fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account.
Spray painting of ceiling fan 1200/1400 mm sweep and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler complete all as directed by Engr-in-charge.
Disconnecting & taking down (burnt) exhaust fan of any make 300mm sweep transporting to local workshop, opening, cutting and taking out complete copper winding , cleaning with kerosene oil / diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff /strip type) replacing u/s / missing spare (bush, bearing , capacity etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR , speedy and noiseless running and depositing in E/M yard Note: Bush bearing capacitor shall be measured and paid for separately.
All as per serial item No. 74 here-in-before but exhaust fan 450 mm sweep.
Taking down old and Supply and fix in repair capacitor 4 MFD, 230 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400mm sweep complete all as directed.
Disconnecting and taking down exhaust fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of defective parts, if any, and refixing the exhaust fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing shall be paid on this account.
Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed.
M&L for spray painting of Exhaust fan and testing at site full load with super enamelled heat resistant synthetic white paint duly filling the cavities with filler complete all as directed by Engr-in-charge. (Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts and sockets will be measured and paid separately).
Collecting unserviceable (burnt) table / cabin fan of any make and sweep up to 450 mm from Internal Elect Section, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel / terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturers, varnishing and heating the winding including providing paper insulation (cuff / strip type), replacing unserviceable / missing spares (bush, bearing, capacitor etc), fixing the stator in rotor properly aligned and reassembling ensuring right DOR, speedy and noiseless running and depositing in E/M Yard for further issue to the user.
Supply only ionization smoke detector all as specified and directed by Engineer in charge .Make Siemens or equivalent in performance in Bosch/Schneider/ABB as approved by GE.
Supply only battery maintanence free 12V 7 AH all as specified and directed by Engineer in charge.Make Exide /Amron/Amco
Supply only battery maintanence free 12V 28 AH all as specified and directed by Engineer in charge. Make Exide /Amron/Amco
Supply only Zone cord for fire alarm system all as specified and directed by Engineer in charge. Make:Siemens/Bosch/Adward/Noti Fire
Periodical maint to Fire alarm systems installed in three technica buildings (two loop system ) of make Siemens including replacement of faulty service parts of fire alarm system ( Fire alarm controll pannel ) The alarm function of controlls of controll and indicating eqpt (controll Pannel) will be checked by operation of trigger of each zone.All fault indicator and their circuits shall be checked by stimulation of fault condition (SMOKE DETECTOR ) Smoke detector shall be cleaned periodically so as to remove dust or dirt that accumulates on them due to local ambiant condition at least each detectors is cleaned twise in a month, MANNUAL CALL POINTS HOOTERS: All mannual call points will be operated twise a month by removing glass cover or by actual braking go glass so as to ensuare that system is capable of operation under alarm conditions and all hooters give proper sound, RESPONSE INDICTORS All detctectors which are placed in side a cabin or room will be tested by indicating the particular detetor.So as to ensuare the proper working of response indicator . WIRING AND CABLES : A visual inspection will be made so that structure or occupancy changes do not damage cables and sitting of trigger divice (mannual call points ,smoke detectors and heat detectors Note: All major items will be paid and measured seperatily
Atternding comptaints of internal elect supply,including locating and rectification of fault and ensuring the compete serviceablity with replacement of defective/unserviceable components such as switches ,sockets,lamp,holder ,ceiling rose of any type ,DBs,MCB main switches service wires/cables etc and other accessories and per site requirement . the deffective items shall be measured and paid for separetly under respective items here-in-after or issued from MES store yard free for fixing only (if not availeble in this CA) Note:-(a) Rate are inclusive of taking down and refixing of under related item only. (b) Any Nos of complaint attended at one place/one qtr under one job card will be considered as one job. (c) Emergent compaint will be attended in 02 Hour. (d) Contractor shall be employ one team consisting of one electrician ITI passed and one helper to attend the complaints. (e) Contractor or his representative will report to JE E/M daily at 0900 Hrs on all working days at the complaint cell and collect the compaints slip.After completion of job all complaints slip will be deposited back to complaint cell by 1700 Hrs. (f) Any T&P reqd for rectificaytion of complaints will be provided by the contractor. the rate of T&P deemed to be included in quoted rate.
Supply only , LED Decorative box type batten fitting 1x20W,including LED tube rod retrofit type 20W, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1. Sq. mm from ceiling roseto connector block, including taking down old unserviceable surface mounted fitting of any wattage and type, complete all as specified and directed by Engineer-in-Charge. Make: Havells cat equivalent in WIPRO/PHILLIPS/CROMPTON
Supply only Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver 9W including taking down old unserviciable surface mounted fitting of any watage and type complete all as specified and directed by Engineer in Charge Make :Havells /Crompton/Wipro
Supply only wall mounted fittings with ABS housing and clear polycarbonate cover including LED bulb 15watts complete and provision of flexible copper 3core cable 0.5Sqmm from connector/ ceiling rose to fitting all as specified and directed Make : Havell's /equivalent HPL code HPL81410(CW) /Bajaj/philip
Supply only Ultra modern designed architectural LED luminaire 36W which provides soft-light and glare free symmetrical illumination suitable for Armstrong/Grid ceiling Cat no VENUSNEOHE2X2PLR36WLED8XXS of Havells or its equilant in Cromptorn/ HPL
Supply only Recess mounted downlighter LED 12W with pressure die-cast aluminium heat sink & PC diffuser in white powder including taking down old light fitting complete Cat no INTEGRANEODLR12WLED857S of Havells or its equilant in Crompton/HPL coated finish with integrated driver.
Supply only Switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified.
Supply only Switch Bell push, flush type, single pole, one way,, 230volts complete all as specified.
Supply only Switch piano, flush type, single pole, two way, 5 Amp 230voltscomplete all as specified.
Supply only Switch piano, flush type, single pole, one way, 15 Amp 230volts complete all as specified.
Supply only Socket outlet multipurpose 3 pin, 5 Amp and 2 pin 5 Amp, flush type, complete all as specified.
Supply only Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified.
Supply only Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified.
Supply only Fan regulator electronic, socket type, suitable for 1200mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified.
Supply only PVC angualr holder suitable for 230V AC all as specified and directed
Supply only MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
Supply only MCB 32/40 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified.
Supply only MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
Supply only MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
Supply only MCB 32/ 40 Amp, 230 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
Supply only MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified.
Supply & Fix in replacement of electronic energy meter with LCD display 10-60A ,complete all as specified and directed by Engineer-in-Charge. Make L&T Cat no WM101BC7DLO or equivalent in performance in Secure Meters/GE/Legrand as approved by GE. Note : Old meter will be deposited to AGE E/M yard
Supply & Fix in replacement of electronic energy meter with LCD display 5-30A ,complete all as specified and directed by Engineer-in-Charge.Make L&T Cat no WM101BC5DL0 of L& T or equivalent in performance in Secure Meters/GE/Legrand as approved by GE. Note : Old meter will be deposited to AGE E/M yard
S & F in replacement of electronic energy meter 10-60A 3Ph 4 wire kWh direct reading L& T.Make L&T Cat no WM101BC5DL0 of L& T or equivalent in performance in Secure Meters/GE/Legrand as approved by GE. Note : Old meter will be deposited to AGE E/M yard
Material and labour, earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32mmx6mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed.
M & L for chemical earthing using mixture of Magnesium sulphate(MgSO4)100kg,common Salat 200 Kg and charcol 300 Kg complete with copper earthing plate 90Cmx60Cmx5mm complete burried on ground vertically to a depth not less than 3.5 M below the ground level with top edge of the plate at a depth not less than 2.5 meter below ground level and mixture shuld be filled 15 cm above top edge of earth plate to active result not less than one ohm resistance ,including copper strip 25x4mm size by means of brass bolts,nuts,check nuts and washeres and brazing of copper earth strip protected by galvonised steel pipe 40mm bore light grade connected to main switch board or any othe electrical switch board or any othe electrical equipment all as shown in electrcal plate no 3 of SSR part I and including necessory excavation ,earth work in any type of soil and earth pit should be refill with black cotten /clay soil ,20mm medium grade water GI pipe for watering ,funnel with wire mesh ,PCC (1:2:4)type B1 reinforced with XPM of weight not less than 4 kg/Sqm and MS frame etc all as specified and directed by Engineer in charge
Material & labour in replacement for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25 x 4 mm galvanised iron strip, complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductions above ground complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 20 x 3 mm copper strip , complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement for test point made out of GI strip 50x6mm, 200 mm long brass nut bolts - 2 Nos and 12mm dia GI nut bolts 40mm long- 03 Nos complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement for test point made out of copper strip 32x6mm, 200 mm long brass nut bolts - 2 Nos and 12mm dia GI nut bolts 40mm long- 03 Nos complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement for air termination, single pointed aluminium rod 12 mm dia and 300 mm long fixed to GI pipe bracket complete all as specified and directed by Engineer-in-Charge.
Material & labour in replacement for air termination, single pointed copper rod 12 mm dia and 300 mm long fixed to GI pipe bracket complete all as specified and directed by Engineer-in-Charge.
Suppy & Fixing/laying in repair galvanised, steel ( GI) , medium grade, ISI marked, 40mm bore with all fittings for fixing air termination rod complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 Type C-I using 20mm graded agrgate for PCC of size 0.3x0.3x0.25 cube with for mounting GI pipe 40mm dia
M & L for PCC chamber in PCC (1:2:4) type B-1 including RCC cover for earth pits , complete all as specified and directed by Engineer in charge
Note:- Amount of credit of Rs. 40206.00 for retrieved materials is mentioned in Schedule of Credit Page No 114 & 115 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Arun enterprises
R D Bansal
HARISH SALES CORPORATION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .