| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹47.5 L+₹9.0 L (23.3%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹49.9 L+₹11.4 L (29.6%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
15 Sept 2022, 6:00 pmClosed
GE UTILITY AMBALA
GE UTILITY AMBALA CANTT 133001
REPAIR MAINT OF OH CONDUCTOR LT UNDER GROUND CABLE LT PANEL LT POLES AND ALLIED WORKS AT SECTOR A UNDER GE UTILITY AMBALA CANTT
2022_MES_542424_2
CA NO GE U AMB T 25 OF 2022-23
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹92,000
3 Oct 2022
16 Aug 2022
17 Sept 2022
16 Aug 2022
15 Sept 2022
1 Sept 2022
16 Aug 2022 - 22 Aug 2022
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and as directed by Engineer-in-Charge.
All as per Ser Item No 1.00 here in before but exceeding 1.5 mtr deep but not exc 3.0mtr deep.
M & L sand cushioning with layer of sand 80mm thick before laying of cable and 150 mm thick after laying of cable, in trenches complete all as specified and as directed.
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in vertical direction to cable as cable protection complete all as specified and as directed.
All as per Item Ser No 4.00 here in before but except bricks. Note: Old bricks retrieved from item No 19.00 here in after shall be re-used after cleaning and washing.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in pole foundation, coping, stay pits etc including provision of necessary form work to achieve fair finish surfaces, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
BLANK
Supply, erection in replacement of PCC pole 9.0 mtr long in true vertical position 102x172 mm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-charge. Note: Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
Supply, errection in replacement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type SP-31 (9 mtrs long) incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-charge. Note: Earth work and PCC shall be measured and paid separately. (ii) Description as per direction of Engr-in-Charge will be printed on each pole without any extra cost.
Supply and fix in replacement of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 core x 10-50 Sqmm complete all as directed by Engr-in charge.
Supply and fix in replacement of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 core x 70-150 Sqmm complete all as directed by Engr-in charge.
Supply and fix in replacement of indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 core x 185-300 Sqmm complete all as directed by Engr-in charge.
Supply and fix in replacement of straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 core x 70-150 Sqmm complete all as directed by Engr-in charge. Note: Earth work shall be measured and paid separately.
M&L drilling hole of any size manually as per site requirement, drilling for laying pipes under the road for crossing electrical cables complete all as specified and directed by Engr-in-charge. Note: Pipe shall be measured and paid separately.
Disconnecting & taking out defective underground cable of any size and any type from trenches, pole, pipe, floor, wall etc and making serviceable through straight through joints and testing on completion and re-laying the same all as specified and as directed.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 25 sqmm 3.5 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks, Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per Item Ser No 20 here in before but for 3.5 core 35Sqmm.
All as per Item Ser No 20 here in before but for 3.5 core 50 Sqmm.
All as per Item Ser No 20 here in before but for 3.5 core 95 Sqmm.
All as per Item Ser No 20 here in before but for 3.5 core 120 Sqmm.
All as per Item Ser No 20 here in before but for 3.5 core 185 Sqmm.
All as per Item Ser No 20 here in before but for 3.5 core 240 Sqmm.
All as per Item Ser No 20 here in before but for 3.5 core 300 Sqmm.
Supply and fixing stay assembly complete with all accessories, such as stay plate 230X230X6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc. all as per electrical plate No 1 of SSR part 1 and as directed incl taking down old unsv. Note: Excavation, earthwork and PCC work will be measured and paid separately.
M & L in replacement incl dismantling and taking down old cross arms, bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated including provision of two coat of synthatic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L in replacement of shackle type porcelain vitreous white or brown insulator including GI straps, washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm height, 90 mm dia, section of strap 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement of pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm height, 65 mm dia with GI spindle two GI washer and one GI nut complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable ACSR conductor any type/size incl cutting, welding complete all as per direction of Engr-In-Charge.
M&L for aluminium conductor steel reinforced (ACSR) any type as per existing size including fixing, stretching on poles and proper noseling with binding wire and insulator of any size as required at site complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as directed by Engr-in Charge.
Dismantling and taking down old u/s earthing, Material & labour for earthing complete with galvanized steel earth electrode plate of size 600 x 600 x 6 mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 32 x 6mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6), pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge. Note:- Earthing shall be tested after execution. Payment shall only be made after satisfactory result.
Dismantling and taking down old u/s earthing, Material & labour for earthing complete with galvanized steel earth electrode plate of size 600 x 600 x 6 mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4 mm dia by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6), pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge. Note:- Earthing shall be tested after execution. Payment shall only be made after satisfactory result.
Material and labour for fixing in replacement GI tubing 50 mm bore light grade, on poles,on walls, under floors, road crossing, as reqd at site complete all as directed by Engr-in Charge. Note: Clamps, Nut bolts, saddle etc will be measured and paid separately.
All as per Ser Item No 37.00 here in before but 80 mm dia.
Supply and Fixing in replacement MCCB Triple Pole with Neutral (TPN) 400 Amps , 415 Volts, 40 KA ,4 POLE, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole with Neutral (TPN) 250 Amps , 415 Volts, 40 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole with Neutral (TPN) 200 Amps , 415 Volts, 40 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole with Neutral (TPN) 160 Amps, 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suitable spreades all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole with Neutral (TPN) 100 Amps, 415 Volts, 25KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suisuitable spreaders all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole (TP) 400 Amps, 415 Volts, 40 KA, 3 POLE, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole (TP) 250 Amps, 415 Volts, 40 KA, 3 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge. Make Legrend
Supply and Fixing in replacement MCCB Triple Pole (TP) 200 Amps, 415 Volts, 40 KA, 3 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole (TP) 160 Amps, 415 Volts, 25 KA, 3 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge.
Supply and Fixing in replacement MCCB Triple Pole (TP) 100 Amps, 415 Volts, 25 KA ,3 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suitable spreaders all as per direction of Engr-in-Charge.
M&L for detecting of fault in cable of any type with fault locator equipment which is capable to supply electricity from serviceable cable to cable. Note :- (a) The fault which is detected through cable fault locator will only be paid under this item (b) Charges of fault locator and DG set including transportation charges deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single fault and no dealy on this account will be acceptable otherwise penality will levied Rs 500/- per day. (d) Necessary testing of cable after making joint will be deemed to be included in the cost of relevent item. However necessary earth work cable cutting, making Joint will be paid under relevant item.
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4/5 line as per IS complete as per direction of Engr-in-Charge.
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 3 line as per IS complete as per direction of Engr-in-Charge.
Removing LT over head conductor from insulator where ever required and restreching the same without any kink/bend up to premissible sag, binding it on insulator by means of binding wire including fixing line seperator at 3 places where required and directed and testing LT over head line on completion and all as specified and directed(Each Run of line conductor shall be measured & paid separately. Spacer shall be paid seperately)
Taking down unsv existing change over switch, Supply and fixing in replacement off load changeover switches 4 pole 100 Amps, 415 volts, with enclosure complete all as per direction of Engr-in-charge.
Taking down unsv existing change over switch, Supply and fixing in replacement off load changeover switches 4 pole 200 Amps, 415 volts, with enclosure complete all as per direction of Engr-in-charge.
Material and labour for fixing in replacement of steel nuts, bolts, washers of any size required at site incl dismantling old rusted nuts bolts as per direction of Engineer-in-Charge.
Material and labour for fixing aluminium lugs (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm incl dismantling old thimbles of any type.
Material and labour for fixing aluminium lugs (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm incl dismantling old thimbles of any type.
Material and labour for fixing aluminium lugs (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm incl dismantling old thimbles of any type.
M & L for cutting of road/PCC footpath/hard standing/interlocking tiles work including excavation for laying cable/pipe and making good surfaces as per existing specification all as specified.
Material and labour for shifting heavy items / excavating / cleaning areas / clearing site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete, all as specified and as directed.
M&L for Chemical spray (DC> 2-26 having container 415ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricates, displaces and seals out moisture release rusted mechanism cleanse etc.
M& L for painting to LT panel board/LT feeder pillar box up to 0.6 x 0.6 x 0.5 M indoor/out door type of size inner shell & outer shell including angle iron frame by applying two coats of synthetic enamelled paint over a coat of red oxide primer after cleaning of panel board inner shell & outer shell by means of rubbing by sand paper and removing rusted and corrded particles, cleaning with clothes including preparing smooth surface for painting all as specified and as directed.
All as per item No 62 here-in before but of size up to 1.0 x 0.9 x 0.5 M all as specified
All as per item No 62 here-in before but of size up to 1.2 x 0.9x 0.5 M all as specified
All as per item No 62 here-in before but of size up to 2.0 x 1.2 x 0.5 M all as specified
M & L for maintenance of LT feeder pillar /LT panel board, any type and size indoor/outdoor by dismantling, opening and taking down of all incoming and outgoing cables, cutting burnt edge of the cable where ever is required, providing thimble of suitable size required for different size of cable including taking out loop of the cables, cleaning of bus bars by means of rubbing etc and providing PVC sleeves of suitable rating on bus bars maintaining colour code (RYB & N) including replacement of bolts nuts & washers and reconnecting the all incoming and outgoing connections and testing of panels on full load all as specified and as directed.
Labour only for welding of existing unserviceable door hinges of LT feeder pillar/LT panel board indoor/out door type, different size panels at different locations including adjusting the door for smooth opening and closing of the panel boards all as specified and as directed.
Material & Labour for cleaning of steel tubular poles 9 mtrs long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall included the repairing of coping with cement/PCC.
Material & Labour cement based paint of Exterior Emulsion for PCC pole 9 mtr long from top to bottom including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc incl repairing and painting on coping with cement base white paint complete all as directed. Note: (i) The quoted rate deemed to be included marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the repairing of coping with cement/PCC.
Supply and fixing in replacement guard wire Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia under overhead ACSR conductor to provide protection against conductor broken complete all as per direction of Engr-in-Charge. Note: (i) Cost of cross arms, nut, bolts, clamps etc are measured and paid separately.
Material & labour for repairing existing earthing any type incl making & cleaning of earth pit, repair of pits, fixing of new funel , pit cover, painting on pit with cement base white paint complete all as per direction of Engr-in-charge. Note: (i) Cost of funel, pit cover, cement work, PCC work and painting etc incl in quoted rates.
Supply and fixing of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm GI strip complete all as directed by Engr-in-Charge.
M & L for spraying chemical on area to remove unwanted vegitation/grass at various locations as directed by Engr-in-Charge.
Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning outdoor type cubical panel board outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places, and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Copper bus bar of 600 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
Supply and fixing MCCB 400 Amps, 36 KA 4 pole 415 Volts AC, adjustable type, complete all as directed by Engg-in-charge (incoming)-01 Nos.
Supply and fixing MCCB 250 Amp, 415 volt, 4 pole, breaking capacity 25 KA , adjustable type ISI marked all (Outgoing)-01 Nos.
Out going MCCB TPN 160 Amps 25 KA adjustable type - 3 Nos
Out going MCCB TPN 100 Amps 25 KA adjustable type - 2 Nos
Interconnection of MCCBs to Busbar with copper strip of suitable size with PVC insulated colour coded heat shrinkable type sleeves - 1 Job
RYB indication lamp LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos
Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete
Note (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv)The bus bar connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip duly insulated. (v) Cable will be entered in panles through gland. (vi)Cost of marking description on the front door as per direction of Engr-in-Charge is included in quoted rate.
Supply, fabricating, erecting, connecting, testing and commissoning of factory made, CPRI approved,cubical type, outdoor type LT panal board, totally enclosed , dust, weather and vermin proof 1100 Volt grade , 50HZ AC supply made out by 3.15mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing, fully compartmentalised, with IP 65 protection all as conferming to IS 2417 of 1962 complete including the following accessories housed all as specified and as directed.
4 Nos bus bar of equal size made out of copper strip of suitable size with PVC insulated colour coded heat shrinkabale type sleeves, of rating 400 Amps, mounted on non cracking resin type insulators - 01 Job
MCCB, 4 pole, 415 volts, 36 kA, with Fixed Thermal Magnetic release, 250 Amps, - 01 No (Incoming).
Interconnection of MCCBs to Busbar with copper strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Job
MCCB, 4 pole, 415 volts, 25 kA, with fixed thermal magnetic release, Ics = 100% Icu, 63 Amps, -06 Nos (Outgoing).
Protection fuses HRC type of suitable capacity for Panel wiring - 01 Job
Indication lamps R, Y & B - 01 Set
Provisioning of copper tinned cable glands for incoming & Outgoing cables. - 01 Job
Interconnection of metering equipment with PVC insulated unsheathed, single core cables 1100 volts grade of suitable size - 01 Job
Notes- (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv)The bus bar connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip duly insulated. (v) Cable will be entered in panles through gland. (vi)Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate.
M & L fabrication in replacement of old unserviceable outer shell/inner shell cover factory made suitable for different size of panels. feeder pilllar boxes according to site and welding of hinges with outer/inner shell. Provision of locking arrangements for outer/inner shell cover as required at site all as specifieid and as directed.
S & F in replacement of Air circuit Breaker, fixed type, spring operated, manualy operated Triple Pole with Neutral (TPN), 4 Pole, 800 Amps, 415 Volt with Thermal magnetic release, (O/L, S/C, E/F protection & confirming to IEC - 60947-2 & 3 rated breacking capacity / making capacity, 50 KA short time current all as specified and directed.
S & F in replacement of Air circuit Breaker, fixed type, spring operated, manualy operated Triple Pole (TP), 3Pole, 630 Amps, 415 Volt with Thermal magnetic release, (O/L, S/C, E/F protection & confirming to IEC - 60947-2 & 3 rated breaking capacity / making capacity, 50 KA short time current all as specified and directed.
Supply and installation of all in one integrated solar street light 25 Watt compact, aesthetic eco friendly and modern integrated solar street in extruded aluminium housing with high efficiency mono crystaline silicon photo voltaic panel,high efficency SMD LED 6500K having secondary lens optic for street light distribution ,high performance lithium battery, MPPT charge controller and intelligent control module/sensor with higher reliability long service life incl pole upto 4 mtr height for mounting of solar lights,suitable for easy and quick installation including earth work pcc 1:3:6 type C1(using 20mm stone aggregate) complete all as specified an directed.
Material & Labour for spray chemical (Roundup) on area to remove unwanted vegitation/grass at various locations as directed by Engr-in-Charge.
Material & Labour for monitoring the software accessories for metering system installed at MRS including MFM, Elite 444 secure make, software for monitoring with other analytic features, gateway with box and other accessories, including installation charges and annual charges per meter per annum complete all as specified and directed.
Note:- Amount of credit Rs. 134360.00 for retrieved materials mentioned in Schedule of Credit attached in tender documents & in pdf form which will be deducted offline while acceptance of tender.
Raman Electric Trading Co
Esha Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .