| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | L1 | Accepted-AOC Agreement executed by Suresh T on 22.2.2022 | |
| 2 | L2₹3.7 L+₹47,304 (14.7%)Rejected-AOC | L2 | Rejected-AOC Agreement executed by Suresh T on 22.2.2022, hence 2nd lowest EMD may be released |
Tender Value
₹4.1 L
EMD Value
₹6,200
Closing Date
20 Dec 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Thiruvananthapuram Corporation 695033
Providing electrification in the class rooms and converting SP connections to 3 phase ate HA LPS Vizhinjam in Harbour Ward City Corporation Thiruvananthapuram.
2021_LSGD_460189_1
EE(C)/OWNFUND TENDER/2021-22 (8)
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹900
Yes
₹6,200
Yes
4 Apr 2022
13 Dec 2021
22 Dec 2021
13 Dec 2021
20 Dec 2021
13 Dec 2021
60 days
Amount
(90.2.1.1)Supply and wiring points according to IS 732-1989 using rigid PVC ivory Conduit of minimum size 20mm conforming to IS 9537 Part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade including providing switch board main and continuous earthing with 1.5 sqmm green coloured FR wire required quantity of copper earth socket, brass bolt and nuit crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories)
(90.2.1.1) Single control light point with 6A, 3Plate ceiling rose
(90.2.1.3 ) Single controll light point with out ceiling rose.
(90.2.1.4) Single control ceiling fan point with 6 A.3 plate ceiling rose and with socket typed electronic regulator.
(90.2.1.6) Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
90.3.18.1. Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. 25 mm dia with HG company fabricated clamps
90.4.8. Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
(MR1183) 36/40 W 4000 lumen LED, IP66 street light fittings with Aluminium housing stove enameled CRCA sheet, Steel reflector cover, acrylic cover complete with THD <10%, power factor>0.98, RoHS complaint duly wired up for use on 230 V ac supply
90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture
90.4.1 Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required
90.4.5.2 Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
1200 mm sweep (Category B) 5 star rated.
(90.6.4.2) Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 1.00 sq mm 2 run
90.6.4.12 1.50 sqmm 2 run
90.6.4.13 1.50 sqmm 3 run
90.6.4.14 1.50 sqmm 4 run
90.6.4.22 2.50 sqmm 2 run
(90.6.4.32) 4.00 sq mm 4 run
(90.6.4.44) 6.00 sq mm 4 run
90.12.1.40. Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).
4 core 10 sq mm
90.12.7.40 .Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
4 core 10 sq mm
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 sq mm
1.27.5. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 Amp switch.
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
1.27.3. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
2.8.6 Supplying and fixing following pre wired TP &N MCB distribution board of seet sheet for 415 Volts on surface /recess complete with loose wire box, terminal connectorers for all incoming and outgoing circuits duly pre wired with suitable size FRLS PVC insulated copper conductor upto terminal blocks, tinned copper bus bar neutral link earth bar detachable gland plates interconnections powder painted including earthing etc. as required (but without MCB/RCCB/Isolator) 6 way (4+8) Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel MCB distribution board 415 volts,on surface/recess, complete with tinned copper bus bar, common neutral link, earth bar, din barfor interconnections, powder painted including earthing etc. as required. (but without MCB/RCCB/Isolator) 4 way (4+18) double door
2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
2.15.3.Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
2.10.2 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supply , conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20 mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS 305 mm sweep 1400 rpm Heavy duty exhaust fan working on 230 V AC
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and providing the following size of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required.
300 X 300 X 6 mm cast iron gully trap with covering
Supply and providing test joint for the earthing system using 2 Nos. of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required
2x25x3 mm GI Strip
Supply and providing earth lead from the test joint to the earth electrode using following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm GI strip
Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc as required.
2.00 mm copper conductor (14 SWG)
3.15 mm cipper conductor (10 SWG)
Supply and laying bare copper conductors of the following sizes laid 0.6 m below ground level including excating trench of suitable size and refilling etc. as required. (in ordinary soil)
3.15 mm copper conductor (10 SWG)
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 600 x 300 x214 mm
S & F switch disconnector unit (isolator) complete with handle assmebly, door inter lock and padlocking arrangement of the following ratings.
or Supply and fixing the following accessories in the existing meter board and giving connections etc.
63 A 415V DIN type fuse base.
63 A 415V Backelite fuse fittings
32 A 415 V2 way neutral link mounted on DMC/SMC base
Amount remitted to KSEB for obtaining power supply (actual amount will be reimpersed on productionof original receipts)
SYNERGY POWER TECH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_658590.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .