Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 CrAccepted-AOC PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | ₹6.6 Cr Quoted ₹6.7 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹6.8 Cr+₹9.7 L (1.44%)Rejected-AOC | ₹6.8 Cr+₹9.7 L (1.44%) | L2 | Rejected-AOC Reject |
| 3 | L3₹7.8 Cr+₹1.0 Cr (15.4%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | ₹7.8 Cr+₹1.0 Cr (15.4%) | L3 | Rejected-Finance Being Not Lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical No Remark in WLR QE Sep 2022 circulated vide CESC Pune letter No 800020/2/WLR/ S to D/ Sep 2022/48/E8 dated 07 Feb 2023 |
Tender Value
₹7.2 Cr
EMD Value
₹6.8 L
Closing Date
19 Apr 2023, 11:00 amClosed
CE (AF) GANDHINAGAR
LEKAWADA PATIA CHILODA GANDHINAGAR 382042
ADDN/ ALTN/ IMPROVEMENT TO CERTAIN OMQs/ SMQs AT AF STN JODHPUR
2023_MES_585786_1
80319
Open Tender
Civil Works
Item Rate
365 days
GE (AF) NO. 2 JODHPUR
AS PER TENDER DOCUMENTS AND NIT
9 documents required · 9 mandatory
₹3,000
GE (AF) NO. 2 JODHPUR
₹6.8 L
Yes
15 May 2023
14 Mar 2023
20 Apr 2023
14 Mar 2023
19 Apr 2023
4 Apr 2023
20 Mar 2023 - 28 Mar 2023
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.5 sqm each complete all as specified and directed
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each complete all as specified and directed.
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removing from site to store complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site to store complete all as specified and directed.
Dismantling of cast iron or reinforced concrete drain pipe, jointed in cement mortar and taking out of trenches or in vertical position of internal dia 100 mm & less complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing of debris to out side MoD land complete all as specified and directed.
Demolition of cement concrete (reinforced) in any position not otherwise specifically provided for segaration of reinforcement from concrete and removing of debris to out side MoD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing of debris to out side MoD land and rubbish off the premises complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of walls and applying one coat of white wash complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for complete removal of old/ existing treatment by mechanical means from walls and applying one coat of primer and 1 mm wall putty & sanding on plastered surfaces prepatatory to distempering and applying two coats of oil emulsion distemper white or tinted by pump roller applicator complete all as specified and directed.
M&L for preparation of old decorate plastered or unplastered surfaces of walls and applying two coats of oil emulsion distemper white or tinted over a layer of wall putty including removing existing nails, if any, any Nos and filling the disturbed surface/holes making smooth surface complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls applying one coat of cement base paint, white or tinted, complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil emulsion distemper white or tinted including one coat of primer complete all as specified and directed.
M&L for preparation of new decorated plastered or unplastered surfaces of walls applying two coats of cement base paint, white or tinted, all as specified complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described priming with red oxide and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description, over 10 cm in width or girth, not otherwise described priming coat with pink primer and applying two coats of synthetic enamel paint complete all as specified and directed.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded complete all as specified and directed.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete without glazing bars complete all as specified and directed.
M&L powder coated (minimum thickness of powder coating shall be 50 micron) anodised aluminium frame for doors, windows, louver type ventilators with one or more rebate including rotating type fixing arrangement for fixing of louver glass joining cleat for fixing etc complete all as specified and directed.
S&F 35 mm thick factory made , second class hard wood plain framed panelled shutter (two panel) with lock rail and panel of 9 mm BWP commericasl ply or 12 mm veneered particle board with commercial veneering on both face .The size of rail and stile as per IS: 1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35 mm thick factory made , second class hard wood and skeleton shutters open rebated and prepared to receive glass gauze etc (without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 300 mm long aluminium alloy anodized silding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F for 100 mm long butt hinges, medium weight stainless steel complete all as specified and directed.
S&F aluminium handles, cast type, anodized, of size 150mm complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F 300 mm, mild steel, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F floor door stopper, with 150 mm long cover plate, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
S&F in repairs aluminium handles, cast type, anodized, of size 150mm complete all as specified and directed.
S&F in repairs 300 mm long aluminium alloy anodized silding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in repairs 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed.
Welding in repairs exc 2.5 cm & n exc 5 cm in length & thickness of metal n.exc 6 mm complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&Fin repair 25 mm dia stainless steel SS Grade-304, 1mm thick curtain rod with and including stainless steel fixing brackets and fancy type end caps, stops rollers etc complete all as specified and directed.
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones complete all as specified and directed.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads supplied with shutters in square n.exc. 0.5 sqm in each pane complete all as specified and directed.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed.
S&F in repair CP tubular towel rail, 20 mm dia, D type, 60 cm long between flanges and complete all as specified and directed.
S&F in repair CP grating 100 mm dia all as specified and complete all as specified and directed.
S&F in repair glass corner shelf (set of three) fixed with and including chromium plated brass screws and wooden/plastic cleats and complete all as specified and directed.
S&F in repairs stainless steel plate rack 0.56mm thick of standard pattern of size 900x750x250 mm fixed in position complete all as specified and directed.
S&F in repairs stainless steel plate rack 0.56mm thick of standard pattern of size 750x600x250 mm fixed in position complete all as specified and directed.
S&F 18/19 mm thick , prelaminated particle board ISI marked interior grade pelaminated both sides with decorative choice laminations , fixed with screws to timber frame work for doors , partition on wall in cup board/ kitchen cabinets etc in shelves partition and shelves of built in cup board almirah book case toilet boxes racks pelmets etc and similar works complete all as specified and directed.
S&F continuous (piano) hinges mild steel bright finish or electro galavanized width of flaps (when open ) 30 mm complete all as specified and directed.
S&F 40 mm dia cupboard knobs of fixed with nut screw and washers of mild steel bright finished complete all as specified and directed.
S&F ball catches with 8 mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and directed.
M&L for second class hardwood plain fillets of sectional area n exc 3 sq cm square ,rectangular or triangular in section clean sawn bull nosed splayed chamfered or rounded on one edge or face secured with nails or brads complete all as specified and directed.
S&F in repairs 15 mm bore bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs, 15 mm bore stop valve, fancy type, chromium plated with long shank and cup , screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F 15 mm bore stop valve, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs 20 mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
S&F in repair brass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs brass chromium plated health faucet of 15 mm bore complete all as specified and directed.
S&F in repairs brass chromium plated center hole basin mixer of 15 mm bore without popup waste system, complete all as specified and directed.
S&F in repairs brass chromium plated sink mixer of 15mm bore with regular spout w/m, complete all as specified and directed.
S&F in repairs brass chromium plated wall mixer of 15mm bore with bend (Provision for O H Shower) complete all as specified and directed.
S&F in repairs PVC connection 15 mm size with nuts of length 450 mm complete all as specified and directed.
S&F in repairs stainless steel toilet paper holder fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe PVC connection 15 mm size with nuts of length 450 mm.complete all as specified and directed.
S&F in repairs, EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified and complete all as specified and directed
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including PVC 'P' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish and complete all as specified and directed
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed
S&F in repairs single mirror bath room cabinet moulded body and framed (made from strong and fine quality ABS plastic ) with hinged door of size 16 " x 12 " x 6 " white or ivory colour fixed on wall with appropriate rawl plugs complete all as specified and directed. Make : Prayag/Polytuff.
S&F in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
S&F in repair sink with drainage board made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915 mm x 460 mm, bowl size 410mm x 330 mm x 160 mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified and directed.
S&F in repair sink made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495 mm x 420 mm, bowl size 410mm x 330 mm x 160 mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified and directed.
S&F in repairs 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms) complete all as specified and directed.
S&F in repairs 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore plastic ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms) complete all as specified and directed.
Cutting chases stone concrete blocks pinning in making good to facing where required and pointing in CM 1:3 to ends or edge of landings steps cills sunshades shelves lintels etc and cutting chases for conealed water tuibing making good not exceeding 10 cm girth for stone walls complete all as specified and directed.
Refixing old steel tubing, 20mm bore, and connections with new or old position (Walls, ceiling, floors, etc.) Note :- Steel tubes obtained from respective item of BOQ (Taking up) shall be used under this item complete all as specified and directed.
Supply and laying 15mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls (concealed type) and ceilings or laid in floors complete all as specified and directed.
Supply and laying 20 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors complete all as specified and directed.
S&F PVC (SWR) gully traps of size 125/110 mm,setting and jointing with solvent cement and complete and complete all as specified and directed.
S&F in repair for PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floorscomplete all as specified and directed.
S&F in repair for PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed in walls complete all as specified and directed.
S&F in repair for PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repair for PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints but fixed in walls complete all as specified and directed.
S&F in repair for PVC (SWR), junction single, (Single T) with door 110 mm dia equal or unequal complete all as specified and directed.
All as per item No.85 ,but 75 mm dia complete all as specified and directed.
S&F in repair for PVC (SWR) door bends 110 mm dia complete all as specified and directed.
All as per item No.87,but 75 mm dia complete all as specified and directed.
S&F in repair for PVC (SWR) Cowl 110 mm dia complete all as specified and directed.
S&F in repair for PVC (SWR), 75mm dia of floor trap, with grating including jointing with solvent cement and complete and complete all as specified and directed.
Wire brushing and cleaning top surfaces of tarrace or cement concrete including dismantling existing old roof treatment and junction of parapets and removing debris to out side MoD land complete all as specified and directed.
M&L for screed bed 10 mm thick on concrete surface in cement mortar (1:4) finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and directed. Note:- WPC will be measured & Paid separately
Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg/Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane reinforced non-woven polyester, weight not less than 3.50 Kg/Sqm and sealing all the over laps 100 mm in length side and 100 mm in width side of membranes laid with torch application complete complete all as specified and directed.
Supply only integral water proofing compound ISI marked complete all as specified and directed.
M&L for water proofing treatment of sunken floor of WCs bathroom etc by applying of the following specifiaction:-(i) Cleaning of sunken floor surface with mechanical means i.e wire brush/air blower etc and remove all loose/unsound material dirt dust etc. (ii)Applying cement slurry mixed with acrylic based polymer modified cementious composite compund coating Hydroproof Xtra of FOSROC /Equivalent of Dr Fixit of Pidilite industries Ltd in the ratio 1:2:4 (one part of acrylic polymer : two part of water and four partof cement) (iiii) First layer of cement slurry @0.444 kg /sqm mixed with acrylic based modified cementious composite compund @0.222 litre/sqm and allow it to air dry for 4 hour. (iv) Second layer of cement slurry @0.222 kg /sqm mixed with acrylic based dified cementious composite compound @0.111 litre/sqm and allow it to air dry for 4 hour followed with water curing for 48 hours (v) 200 micron thick polythene film shall be pasted with help of adhesive over treatment . Note:- Joints of WC/Trap/Soil waste shall be prperly sealed with sealing compund . Testing of all traps and joints and sunken slab shall be done as per IS-1742 before filling and tiling work complete all as specified and directed.
M&L for plain cement conrete 1:5:10 type E-2 (using 20 mm graded broken bricks aggregate ) as in foundation and mass concrete complet all as specified and complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors complete all as specified and directed.
Supply and laying 32 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors complete all as specified and directed.
M&L for joint free non skid ceramic tiles (edge cut), coloured, 7 to 8 mm thick (square/ rectangular) in floors etc. area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for joint free (edge cut) glazed ceramic tiles, coloured, 450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone or brick masonry surfaces complete all as specified and directed.
M&L for joint free (edge cut) light coloured vitrfifed cermaic tiles double charged, 10 mm thick (square/ rectangular) area of each tiles not less than 0.36 sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1;6 complete all as specified and directed.
All as per item no. 101 above but on vertical surfaces such as dados skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfacesas complete all as specified and directed.
M&L for joint free (edge cut) non skid ceramic tiles, coloured, 7 to 8 mm thick (square/ rectangular) in floors and skirting etc. (square/rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20 -25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigmenst to match the shade of the slab including rubbing and polishing complete including 15 mm screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L for kota-stone slab 15 mm thick in riser of steps skirting dado and pillar & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfaces complete all as specified and directed.
M&L for PCC block masonary with solid blocks exc 10 cm in width 1:3:6 Type C1 using 20 mm graded aggregate and setting in cement moratr 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for granite (of any type ) tiles/ slab 20 mm thick machine cut as in cooking platform over and including 15 mm thickscreed bed in CM 1:6 jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and complete all as specified and directed.
M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection finished surface even and fair without using extra cement all as specified and complete all as specified and directed.
Cutting holes in brick/ stone/ block walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required exc half brick but not exc one brick complete all as specified and directed.
M&L for rolled mild steel framed work as in door or gates of angle or other section with gusset plate rails braces etc complet drilled for fixing of steel sheeting or other covering . Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings 9 exclusive of steel sheeting or other covering running rails and guides ) and hanging also fastening and fixing complete grade Fe-290 (Gde E-165) complete all as specified and directed.
M&L for MS plain black sheet 1.00 mm in wall cladding steel gate and similar work cut to size holes punched includinground headed screws clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angles etc as required complete all as required complete all as specified and directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4.00mm dia galvanised iron or steel wire complete all as specified and directed.
M&L for anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
S&F figured glass pin head type 4 mm thick, fixed as louvers in ventilators supplied square n.exc. 0.5 sqm in each pane complete all as specified and directed.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc for 125 X60 mm complete & fixing also as specified supplied and fixed and complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm complete all as specified and directed.
Demoliton of reinforced cement concrete of any description for roofs, floor (Other than ground floor), beams, staicases, landing, chajjas and similar work and removing debris to out side MoD land complete all as specified and directed.
M&L RCC Nominal mix type B 1, 1:2:4 (using 20 mm graded aggregate) for slabs supported on walls, beams and colimns in floor, roofs, landings, balconies, deck slab and in shelves and the like complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent shape required, including cranking , bending, hooking, spirally etc and binding with MS wire 0.9mm dia annealed complete all as specified and directed.
S&F mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs for rough finished surfaces of concrete such as roof slabs, floor slabs, landing and similar work: not exc 200 mm thick (horizental or sloping) complete all as specified and directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cill, concrete railings, opening in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC /PCC bands in walls, horizental or sloping and similar work exc 10 cm but n.exc 20 cm wide for rough finished complete all as specified and directed.
M&L 2nd class hard wood as in plain solid straight chowkats and frames wrought framed rebated on the solid rounded or chemferred put to gather with glue pinned at joints complete all as specified and directed.
M&L for surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard /dense solil complete all a sspecified and as directed
M&L for 75 mm thick plain cement concrete type-C-2, 1:3:6 (using 40mm graded stone aggregate) complete all as specified & directed.
M&L for providing and laying 60 mm thick factory made chamefered edge cement concrete paver block of M-35 grade with approved colour design & pattern as in footpath parks lawns drive ways or lighttraffic parking etc of required strength thickness & size shape made by table vibratory method using PU mould laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand comapcting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator filling the joints with sand and cutting of paver blocks as per required size and pattern finishing and sweeping extra sand complete all as specified and directed.
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces/ walls/ floors etc.
M&L for channel or grooves cutting upto a depth of 2.5 cm and width not exc 15cm into brick/ concrete/ stone masonary walls, with or without re-inforcement and trimming surface as required, including concealing PVC conduit 20/25mm dia with required accessories (like junction boxes/ bends etc) and plastering in 1:4 CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing surface of wall surface complete all as specified and directed. Note : Rate of PVC conduit deemed to be included in the quoted rate.
M&L for point wiring with 1.5 Sqmm, multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLS cable for phase and neutral, icluding 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor single core FRLS cable as earth continuity conductor (in green color) connected to common earth dolly, drawnin surface/ concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following :- Note : (i) Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. (ii) Cutting into chases required for concealing heavy duty (HMS Grade) PVC conduits and making good to damaged surface shall be measured and paid separately under relavant item.
One light/ fan point controlled by one switch one way.
One light point controlled by two Nos 5 Amps switch two way.
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independent board.
One bell point controlled by one switch 5 Amps bell push.
All same as per item Ser No.131 here-in-above but wiring using 2.5 Sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLS cable, inlcuding 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor single core FRLS cable as earth continuity conductor (in green color) connected to common earth dolly for 6pin, 15/16 Amps socket outlet on independant board.
All same as per item Ser No.131 here-in-above but wiring using 4.0 Sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLS cable, inlcuding 4.0Sqmm PVC insulated unsheathed multistranded copper conductor single core FRLS cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/ Geysers.
Supply and fix modular switch single pole one way, 6A, 230 volt one module complete all as specified and as directed.
Supply and fix modular switch single pole two way, 6A, 230 volt one module complete all as specified and as directed.
Supply and fix modular switch single pole one way, 16A, 230 volt one module complete all as specified and as directed.
Supply and fix socket modular 6A, 2/3 pin combined two module complete all as specified and as directed.
Supply and fix socket modular 6A & 16A, 2/3 pin combined two module complete all as specified and as directed.
Supply and fix bell Push modular single pole one way, 6A, 230 volt one module complete all as specified and as directed.
Supply and fix stepped type electronic fan regulator, socket size, flush type 230V AC complete all as specified and as directed.
Supply and fix ceiling rose surface bakelite 65 x 50 mm three terminal complete all as specified and as directed.
Supply and fix Lamp holder insulated PVC/ Poly carbonate/ bakelite body, fixed on PVC round or squre box using necessary screw & gutti complete all as specified and as directed.
Supply and fix electronic Bell Bul-Bul music, 230 Volt, single phase complete all as specified and as directed.
Taking down carefully ceiling fan/ Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades, stacking carefully at site for reuse of serviceable fans complete all as specified and as directed.
Taking down carefully geyser by disconnecting electrical connections & water connection unsecrewing from position, stacking carefully at site for reuse of serviceable geyser complete all as specified and as directed.
Taking down carefully Energy meters by disconnecting electrical connections, stacking carefully at site for reuse of serviceable meters or deposit to Store if new meter provided against replacement complete all as specified and as directed.
Fixing only light fittings any type, connecting up with twin core PVC insulated and PVC sheathed flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. Note : Serviceable light fittings taken down against item No. 129 shall be used at site as directed by Engr-in-Charge.
Suppply and fixing LED light fitting wall/ roof mounted, Aluminium housing, 1 x 20 watt inlcuding LED tube with driver compelte suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 Watt + 10%, surge protection of minimum 2KV power factor should be more that 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and as directed.
Suppply and fixing LED light fitting wall/ roof mounted, Aluminium housing, 1 x 9/10 watt inlcuding LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 Watt + 10%, surge protection of minimum 2KV power factor should be more that 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and as directed.
S&F Building security light fitting, with pressure die cast aluminimu housing, suitable for 25W LED, complete pre-wired, including suitable bracket for fixing light on wall or any indicated locatiion complete all as specified and as directed as per Havells Cat No. ENDURAPEARLSL25W or equivalent model approved mekes.
S&F LED light fitting 1 x 10W bulkhead luminaries including inbuild LED light driver perfect interior and exterier application connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
M&L for cutting holes 300mm diameter for preaparing opening through wall for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall complete all as specified and directed.
Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.50 Sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified and directed. Note : Fan taken down against item No. 144 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleaning of dust etc, the same shall be included in the quoted rate).
Fixing only and exhaust fan 300mm sweep, steel/ PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using, flexible three core 0.5 Sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/ connector to fan complete all as specified and directed, Note : Exhaust Fan/ wall fans taken down against item No. 144 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleaning of dust etc, the same shall be included in the quoted rate).
Fixing only and connecting electric meters upto 100 Amps with necessary incomming and outgoing copper cable using suitable size copper alloy thimbles/ lugs and numbering of connected married accomodation number complete all as specified and directed. Note : Serviceable meter taken down against item No. 146 shall be used for refixing.
Supply and fix eletronic meters tamper proof LCD display with polycarbonate cover three phase, 415V, 10-100 Amps, Accuracy Class-I, 50Hz, conforming to IS-13779, IP-54 protection, with parameters to show date, time, current reading, load, power factor, voltage and KWH reading complete all as specified and as directed (for OMQs only).
Installation only Electric storage type water heater (Geysers) 25/50 Ltr capacity with standard fixing accessories including suitable size wall fastener bolts & nuts, gutties etc complete all as specified and directed. Note : Taken down serviceable geyser against item No. 145 shall be used after cleaning and necessary repairs.
Supply and fix energy efficient (BEE 5 Star rating) electrical geyser, 25 Ltr capacity 230 V, AC, Single phase power input 2000w, standing loss in kWh 24 (hours) 45°C 0.511 KW h steel body white/ half white, superior polymer/ glasslin coating steel inner tank with minimum & bar pressure rating, energy saving, insitu PUF insulated, with all in built safety accessories like thermostate/ automatic thermal cut out with ON/ OFF / CUT out indicators all pre-wired and advanced 3 level safety including accessories like thermostat, pressurer release valve/ presure reducing valve, non return valve, connecting HOT & COLD steel braided PVC heavy duty pipe with brass ferrule fitting for HOT and COLD water connections fixed as per manufacturers recommendation, making necessary connection & testing on completion complete all as specified and directed. Note : Quoted rates deems to be inclusive cost of wall fasteners required for hoisting geysers. Any defect during warranty period shall be rectified by contractor from original manufacturer. All warranty card duly ink signed/ stamped from distributer shall be handed over to MES on completion.
S&F Exhaust fan 300mm sweep, copper wounded, four blade, metal body, BEE approved/ ISI marked, air delivery shall not be less than 230 CFM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 Volt, single phase, 50 cycle per second, AC supply and connecting up using flexible core wire using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position ass recommended by manufacturer complete all as specified and directed.
M & L submain wiring with two runs of 2.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduits heavy duty grade ISI marked 20 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories and one run of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor including taking down old unserviceable submain wiring complete all as specified and directed. Note : 2 runs of 2.5 sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit complete all as specified and directed.
M & L submain wiring with two runs of 6.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduits heavy duty grade ISI marked 25 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories and one run of 6.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor including taking down old unserviceable submain wiring complete all as specified and directed. Note : 2 runs of 6.0 sqmm copper cable & 1 run of 6.0 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit complete all as specified and directed.
M & L submain wiring with Four runs of 6.0 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVC conduits heavy duty grade ISI marked 32 mm dia (External) with wall thickness not less than 1.8 mm with conduit accessories and Two run of 6.0 Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable as earth conductor including taking down old unserviceable submain wiring complete all as specified and directed. Note : 4 runs of 6.0 sqmm copper cable & 2 run of 6.0 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit complete all as specified and directed.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 16 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completon complete including taking out old unserviceable sheet metal enclosures all as directed.
Supply and replace sheet metal enclosures distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old unserviceable sheet metal enclosures complete all as specified and directed.
Supply and replace sheet metal enclosures distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old unserviceable sheet metal enclosures complete all as specified and directed.
Supply and fix sheet metal enclosure distribution board TPN, 415 Volts, 4 way Horizontal/ vertical type as per site requirement double door type, 200 Amps rated neutral copper bus bar for housing MCBs, blank plates and including provision for fixing TPN MCB as incommer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification complete including taking out old complete all as specified and directed.
M&L for MCB TPN/FP, 63 Amps 415 Volts, 10 KA 'B' curve rupturing capacity providing in DB complete including connection & testing complete all as specified and directed.
Supply and fixing of RCCB 2 pole SPN as per IS-12640-1, IEC 61008-1 with rated sensitivity of 32A, 30 milli Amp for protecton against earth leakage current for domestic use to fix in MCB DB complete along with necessary accessories complete all as specified and directed.
M&L for MCB single pole, 6-32 Amps 240 Volts, 10 KA rupturing capacity providing in DB complete including connection & testing complete all as specified and directed.
Supply, installations, testing and commissioning factory made indoor cubical type panel box for fixing energy meter, 4 each separate compartment for each energy meter, frabricated using 2.0mm thick MS sheet, duly provided with 8mm thick flame proof backelite/ hylem sheet for mounting Energy meters in each compartment, and provision pre-wiring and fixing of incomming and outgoing control MCCB/ MCBs, each meter comapartent shall provided with front opening hinged door with internal or external locking arrangement. MS box duly painted with two coats of powder coated semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 100 Amps 4 Pole as incommer and vertical or horizontal copper busbar chamber for taking cinnection to incommer MCB of each meter by using 10 Sqmm, PVC insulated multistranded copper conduction wire single core in proper color codes complete all as specified and directed including fixing fo following items : (a) MCCB 100 Amps, 4 Pole, 16 KA, (Ics=100% of Icu)- as incommer. (b) Copper Busbar 200 Amps duly sleev insulated for set of 3 Phase, 4 wire system - 01 Set. (c) 2 runs of PVC insulated single core multistraded FRLS grade copper wire for connection from busbar to input supply of Each energy meter by using necessary copper alloy lugs/ thimbles. (d) MCB SPN 63 Amps on each meter incomming pre-wired - 4 Nos (One incomming each meter) (e) MCB SPN 40 Amps on each meter outgoing pre-wired - 4 Nos (One outgoing on each meter) (f) LED Indicator lamp (R, Y, B) - Set of Three. Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter box on wall surface and re-fixing energy meters & making all incomming and outgoing electrical connections with existing input cable and outgoing wires.
Supply, installations, testing and commissioning CPRI approved factory made indoor cubical type panel box for fixing energy meter, 6 each separate compartment for each energy meter, frabricated using 2.0mm thick MS sheet, duly provided with 8mm thick flame proof backelite/ hylem sheet for mounting Energy meters in each compartment, and provision pre-wiring and fixing of incomming and outgoing control MCCB/ MCBs, each meter comapartent shall provided with front opening hinged door with internal or external locking arrangement. MS box duly painted with two coats of powder coated semense gray paint over a coat of red oxide primer. The meter box shall designed and fabricated for fixing 01 x MCCB 160 Amps 4 Pole as incommer and vertical or horizontal copper busbar chamber for taking cinnection to incommer MCB of each meter by using 10 Sqmm, PVC insulated multistranded copper conduction wire single core in proper color codes complete all as specified and directed including fixing fo following items :- (a) MCCB 160 Amps, 4 Pole, 16 KA, (Ics=100% of Icu)- as incommer. (b) Copper Busbar 200 Amps duly sleev insulated for set of 3 Phase, 4 wire system - 01 Set. (c) 2 runs of PVC insulated single core multistraded FRLS grade copper wire for connection from busbar to input supply of Each energy meter by using necessary copper alloy lugs/ thimbles. (d) MCB SPN 63 Amps on each meter incomming pre-wired - 6 Nos (One incomming each meter) (e) MCB SPN 40 Amps on each meter outgoing pre-wired - 6 Nos (One outgoing on each meter) (f) LED Indicator lamp (R, Y, B) - Set of Three. Note : Quoted rate includes the cost of all necessary clamp, wall fasters for fixing meter box on wall surface and re-fixing energy meters & making all incomming and outgoing electrical connections with existing input cable and outgoing wires.
M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete including concealed PVC conduit 20mm dia from TV Socket to dish antena on roof of building complete all as specified as directed.
Earthing complete with galvanised steel earth plate 600x600x6 mm burried directly in ground vertically to adepth not lesst than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including GI earth lead 4mm dia by means of nuts ,bolts , washers etc made of and connected to test point and earth dolly as all shown in electrical plate No 3 of SSR Part -I 2009 and specified or indicated including necessary excavation and earth work in any type of strata PCC (1:3:6) TYPE C-1 in chamber ,pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 ,reinforced with welded steel wire fabric or XPM jali ( weight not less than 4.00 kg/ sqm with cast iron frame ,funnel with wire mesh ,20 mm bore medium grade GI watering pipe ,lugs ,15 mm bore medium grade GI protection pipe ,testing on completion complete all as specified and directed Note : (i) Position/ location of PCC chamber shall be constructed as directed by GE/ AGE. (ii) The unit rate deemed to be included earthing lead & protection pipe upto 7.5 mtr top of earth plate.
Supply and laying/ fixing GI pipe 15mm dia, light grade for proctection of GI earth wire 4.00mm dia complete all as specified and directed. Note : Quoted rate shall be deemed to be include cost of GI saddle used for fixing GI pipe on wall by using screw and guttis not exceeding distance 0.6Mtr.
NOTE: Amount of credit of Rs. 1041239.00for retrieved materials is mentioned in schedule of credit on Srl Page No. 30(R) of tender documents in pdf form which will be deducted offline while acceptance of tender.
BABU LAL PARIHAR
ABHOG INFRASTRUCTURE PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .