CHIEF GENERAL MANAGER, ORDNANCE FACTORY CHANDA
ORDNANCE FACTORY CHANDA
REPAIRS/REPLACEMENT TO EARTH PITS FOR LIGHTING PROTECTION AND STATIC EARTHING SYSTEM OF EXPLOSIVE PROCESS AND STORAGE BUILDINGS IN FILLING UNITS INSIDE FACTORY.
2026_MIL_276111_1
OFCH/EO/08 OF 2026-2027
Open Tender
Electrical Works
Works
270 days
ORDNANCE FACTORY CHANDA
AS PER ATTACHED TENDER DOCUMENTS
10 documents required · 10 mandatory
₹0
₹97,600
Yes
18 Jun 2026
30 Apr 2026
22 May 2026
30 Apr 2026
21 May 2026
30 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Cat (A) -Items to be supply and fixing | |||||
| 1.01 | Excavation n.exc.1.5 meter wide and 2.4 meter depth in soft loose soil and getting out etc. for earth pit of L.P.& S.E system complete as per the direction of Engineer-In-charge. | 411.35 | Cum | - | - |
| 1.02 | Excavation n.exc.1.5 meter wide and 1.5 meter depth in soft loose soil and getting out etc. for connecting G.I strips & Earth pit Markers of L.P.& S.E system complete as per the direction of Engineer-In-charge. | 303.73 | Cum | - | - |
| 1.03 | Demolition of cement concrete in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) of any description, all as per the direction of Engineer-In-Charge. | 24.78 | Cum | - | - |
| 1.04 | S & F, Earthing complete with GI earth plate electrode 600X600x6 mm thick buried directly in ground vertical to a depth not less than 2.25 meter below normal ground level, using G.I. Strip of 25X4 mm as a Earthing lead complete as per Electrical plate No. 05 of MES SSR part –I ,complete as per the direction of Engineer-In-charge. | 236 | Each Set | - | - |
| 1.05 | S&F, of GI steel tubes of medium grade of 40 mm bore for protection of G I strip complete as per the direction of Engineer In-charge. | 660.8 | Meter | - | - |
| 1.06 | S & F, of GI steel tubes of medium grade of 20 mm bore, 1.8 meter long with funnels for provision of water pipe as per the direction of Engineer-In-charge. | 424.8 | Meter | - | - |
| 1.07 | S & F of GI Strip 25 X 4 mm for main earthing lead for providing earthing connection from earth pit to test point of L.P/ static Earthing system, complete as per the direction of Engineer-In-charge. | 4,956 | Meter | - | - |
| 1.08 | Returning, filling in including spreading, levelling and well ramming in layers of excavated soft loose soil in earth pit & trenches and making good disturbed surface, complete as per the direction of Engineer-In-charge. | 651.36 | Cum | - | - |
| 1.09 | Supply and fixing aluminium strip 25X3.15 mm with saddles and screw for down conductor of L.P. & SE system complete as per the direction of Engineer-In-charge. | 236 | Meter | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.65 MB
AnnexureD.pdf
Tender Documents • 0.25 MB
AnnexureC.pdf
Tender Documents • 0.26 MB
AnnexureB.pdf
Tender Documents • 0.14 MB
AnnexureA.pdf
Tender Documents • 0.17 MB
BOQ_322479.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .