Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹40.6 L+₹3.3 L (8.83%)Rejected-AOC OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹41.9 L+₹4.5 L (12.1%)Rejected-AOC | L3 | Rejected-AOC Rejected being higher bidder | |
| 4 | L4₹42.9 L+₹5.6 L (15.0%)Rejected-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L4 | Rejected-AOC Rejected being higher bidder | |
| 5 | L5₹43.3 L+₹5.9 L (15.9%)Rejected-AOC 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹46.6 L
EMD Value
₹87,260
Closing Date
30 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF JODHPUR
GE AF JODHPUR
ADDITION ALTERATION OF BUILDING P-70 OF SU UNDER GE AF JODHPUR
2024_MES_635741_1
8616/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JODHPUR
₹87,260
Yes
24 Feb 2024
4 Jan 2024
1 Feb 2024
4 Jan 2024
30 Jan 2024
18 Jan 2024
Amount
Demolition of brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for walling of squared rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
M&L 40mm thick Damp proof course to horizontal or vertical surfaces in cement concrete 1:2:4, type B-0 including necessary formwork complete all as specified and directed.
M&L for precast cement concrete block masonry of blocks exc 10 cm thick, built in PCC 1:3:6 type C-1 using 20mm graded stone aggregate, set and jointed in CM 1:6 in walling complete all as specified and directed.
M&L for reinforcement cement concrete type M-25 design mix (using 20mm graded stone aggregate) as beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
M&L for mild steel TMT bars 5mm to 10 mm dia and over, cut to length, bent to shape required, including cranking as in stirupps, spacers, binders etc and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation, sub base, filling and mass concrete complete all as specified and directed.
Excavation in trenches n.exc 1.5M wide and n.exc 1.5M in depth for foundation, man holes etc in soft/ loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specification and directed by Engr-in-charge.
Removing excavated soil/material outside MD land and depositing at a place outside MD land identified by the contracor at his own cost complete all as specified and as directed.
M&L for rendering 15mm thick in CM 1:4 on concrete surface including finish even and smooth surfaces without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on concrete surface including finish even and smooth surfaces without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of exterior weather proof water base emulsion paint ( white or tinted) as per approved shade/colour including cleaning of windows, doors, internal fittings & any other surfaces by removing splashes / spots after finishing the job complete all as specified and directed. Note:- Quoted rate shall be deemed to be included for work in buildings/structure of any height.
M&L for preparing newly plastered or unplastered surfaces and applying two coats of OBD over and including one coat of primer including cleaning of windows, doors, internal fittings & any other surfaces by removing splashes / spots after finishing the job complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick laid over and including cement screed 15mm thick in cement mortor 1:6 laid & jointed with grey cement slury mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L machine cut kota stone 20-25mm thick laid over and including 15 cm thick cement plaster in cement mortor 1:4 on skirting, dado, riser of steps & pillars jointed with grey cement slury mixed with pigment to match the shade of the stone including rubbing and polishing complete all as specified and directed.
M&L for hardcore of stone boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 ( using 40 mm graded stone aggregate) as in sub base of flooring complete all as specified and directed.
M&L 25mm thick PCC 1:2:4 type B-1 ( using 20 mm graded stone aggregate) as in sub base for tiles in floors complete all as specified and directed.
Demolition of cement concrete in ground floor & paving n exc 15 cm thick below or above ground level and removing debris outside MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including CM bedding but not backing removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling any type of roof sheets plain or corrugated (AC/CGI) including taking outside MoD land complete all as specified and directed.
M&L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
S&F anodised aluminium snap grid frame work (600mm X 600 mm) for false ceiling complete all as specified and directed.
S&F 8 mm thick exposed metal frame ceiling with fire retardant calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid complete all as specified and directed by Engr-in-Charge. (Note : Frame work for ceiling shall be measured and paid separately.)
S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
S&F aluminium powder coated (thikness of powder coating is 50 micron) aluminium frame for doors , windows, ventilators, partion wall with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F aluminium powder coated door shutters of any colour (Thickness of powder coating not less than 50 micron), aluminium sections weighing 0.55kg/m incl necessary joining cleat glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, aluminium snap beading screws complete all as specified and directed.
S&F plain sheet glass 5 mm thick, ordinary quality and glazing with oil putty or wooden beads supplied with shutters in square exc. 0.5 sqm in each pane complete all as specified and directed.
S&F aluminium (die cast) body door closer hydraulically regulated, designation No 1, universal type suitable for door shutters upto 700 mm in width and of of wt not more than 35 kg complete all as specified and directed.
S&F double action floor spring hydraulically regulated made up of of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Taking down cement plaster on stone masonary walls including racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F rolled mild steel roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde- E- 250) Quality-A complete all as specified and directed.
M&L for erection and fixing only Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.
Taking down old existing roof treatment (APP membrane) and removing debris outside MD land complete all as specified and as directed.
M&L for cleaning of roof slab/chajja with sweeping with brooms, removing all loose materials complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete of any type description and in any position complete all as specified and directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified.
M&L for brushing neat cement slurry with 3kg of cement per sqm complete all as specified.
M&L for 10mm thick plastering in cm 1:3 on green concrete roof surfaces with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing compound ISI Marked.
M&L for applying APP modified membrane, minimum 3 mm thick, (it shall be taken upto height of minimum 300mm through a fillet or 75mmx75mm and shall be inserted inside a groove cut in the parapet and fixed. If the height of parapet is 300mm or less, membrane shall be taken till top of the parapet and finished after covering the top surface to the parapet. For RCC inverted beam the whole beam shall be covered with membrane irrespective of the depth. In case of roof projection, the membrane shall be taken 50mm on the reverse side of roof at the edges) with non-woven polyster reinforcement/mat (centre core) with thermal insulation with white mineral gravel finish on upper side of membrane laid by torch application method with overlaps 100mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.
M&L for providing cement concrete 1:2:4 Type B0 using 12.5 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site complete all as specified & directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube with one or more rebates & fixing in opening as per specification & drawing complete all as specified and directed.
Material & labour for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in bed blocks etc for embedding hold fasts complete all as specified and directed by Engineer-in-Charge.
S&F factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile:), with 2,4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face, with wood free EPS, fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F stainless steel butt hinges, medium weight of size 125 mm complete all as specified and directed.
S&F 100 mm long stainless steel barrel tower bolts (ISI Marked) complete all as specified and directed.
S&F stainless steel handles, fabricated type of size 150 mm (ISI Marked) complete all as specified and directed.
S&F pressed steel frames of size 105X60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike plate, etc., complete all as specified and directed.
S&F flush shutters, 30mm thick solid core construction, with block board core and plywood face panels with 0.90 mm thick decorative laminate type 1 on both side of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer instructions complete all as specified and directed.
S&F 300 mm long stainless steel sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet and fixing bolts and sliding bolts of stainless steel (ISI Marked) complete all as specified and directed.
S&F 150 mm long stainless steel barrel tower bolts (ISI Marked) complete all as specified and directed.
S&F stainless steel handles, fabricated type of size 150 mm (ISI Marked) complete all as specified and directed.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as specified and directed.
Taking down window shutter of area exc 1 sqm and n exc 2 sqm each complete all as specified & directed by the Engineer-in-Charge.
S&F factory made Steel windows 1.25 mm thick box type (primer coated) ERW hollow P sections of size 60mm X 25mm including grill using 10 sqmm bar double riveted both gaze and glass shutter comprised gauged glazed skelton shutters ERW section 50mm X 20mm and 1mm thick with two openable leafs consisting 2 nos sash bar of T section 20mm X 3mm complete welded to frame with one vertical mullion of ERW box type T section of size 60mm X 25mm and 1.25 mm thick including cutting holes and making good dismantled portion in PCC 1:2:4 type B1 four numbers of each window including following fittings welded to frame shutter :- (a) Hold fast, 150 mm long of 12mmX3mm made to shape 04 nos per window (b) handle of Z section 20mmX25mm, 100 mm long -per leaf (c) Mild steel tower bolt 150mm long - 02 Nos per leaf (d) Z section 20mmX25mm, 100 mm long stopper -01 nos per leaf (e) Cleat 55mm long of hollow square 15mm X20mmX63mm welded to hinge -01 Nos per Leaf (f) MS pintal hinges of size 75mmX12mm- 02 Nos per leaf including stainless steel wire cloth, 0.25mm to 0.36mm nominal dia of wire and average width of aperture 1.40mm to 2mm and fixed with aluminium wire staples and glass pan 3mm thick fixed with MS pin and oil putty including two coats of synthetic enamel paint complete all as specified and directed. NOTE :- (i) During fixing of window surface shall be make good in plumb with existing finishes like cement plaster, similiar wall tile, floor tile etc and as per site requirement.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over and including a coat of red oxide or zinc chrome primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc and applying two coat of oil bound distemper white or tinted over and including a coat of white putty in patches as required all as specified and as directed by Engineer-in-Charge.
M&L for complete removel of old existing tretment of wall surfaces and repair, stopping nails marks by applying white cement base putty in patches as required and applying one coat of exterior weather proof water base emulsion paint ( white or tinted) as per approved shade/coloured on walls complete all as specified and directed. Note:- Quoted rate shall be deemed to be included for work in buildings/structure of any height.
Taking down carefully copper/aluminium point wiring light, fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for one light/ fan/Exhaust fan point controlled by one switch/regulator using approved colour coding as per IS (Red , Black and Green for single phase circuits), with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and including sunken type metal boxes suitable for modular switches and including modular plates for fixing of switches, sockets and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distempered match with original colour complete all as specified and directed by Engineer-in-charge.
All as per item 69 No above but for One 3 pin 5 amps socket outlet on independent board with other switch.
All as per item 69 No above but for one 3 pin 5 amps socket outlet on the same board with other switch.
All as per item No 69 above but with 2.5 Sq mm copper conductor multistraned pvc insulated and unshethed cable for Independent one 3 pin 15 Amps socket outlet and including 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire.
S&F modular switches 6 amps single pole one way complete all as specified and directed.
S&F modular socket outlet 6 amps 5 pin combine 2 Module complete all as specified and directed.
S&F modular switches 16 A single pole one way, 1 Module complete all as specified and directed.
S&F modular socket 6-16 A 2/3 pin combined 2 Module complete all as specified and directed.
S&F step type fan Speed regulator 5 steps, 120W-2 Module complete all as specified and directed.
M&L for sub main wiring with 2 run of 4.0 Sqmm cable multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked suitable size (not less than 20 mm dia) alongwith fittings and accessories all fixed concealed on wall and also including one run of 4.0 sqmm cable for earth wire as earth continuity conductor complete including taking down existing sub main wiring all as specified and directed by Engineer in charge. (Note : 2 runs of main cable one run of earth wire and one run of PVC pipe will be measured as an one run).
All as per Item No 78 above but 2 run of 10 Sqmm cable and one run of 10 sqmm cable for earth wire fixed on surface of wall.
S&F MCB 5 to 32 Amps SP 10 KA, 240V 'C' Series complete all as specified and directed.
S&F MCB 40 to 63 Amps SPN 10 KA,240V 'C' Series complete all as specified and directed.
Supply and fixing ceiling rose polycarbonate ,isolated body 65 X 50 mm 2 to 3 terminal complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 240V including one MCB 20 amps complete all as specified and directed.
S&F and testing of factory made MCB DB SPN 8 way 240 volt with double door, IP - 43 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
S&F and testing of factory made of MCB DB SPN 12 way 240 volt with double door, IP - 43 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m deep below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete including taking out existing earthing all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe protection pipe. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply and fixing LED lights fitting 1x 20W, 4 feet,220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note:- The old U/S ceiling fan should by deposited to MES store yard by contractor.
Supply and fix in replacement exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed. Note:- The old U/S exhaust fan should by deposited to MES store yard by contractor.
S&F MCCB, 125 Amps, 3 pole,16 KA, 415 volt with fixed thermal maganetic release all as specified and directed by Engineer-in- Charge.
Supply & fixing sheet metal enclosure vertical MCB DB TPN 06 ways, IP 43, with 200 amps rated bus bar 415 Volts suitable for 125 Amps TPN 4 Pole MCCB 36 KA as incomer, double door with magnetic locking system complete all as specified & directed by the Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/ gradients/ slopes for foundations/laying of cable including taking out existing cable and cable protection cover etc. complete all as specified and directed. Note :- Excavation shall be carried out manually all as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.
Material & labour for sand cushioning for LT cable with tibba sand one layer of 80mm thickness before laying of cable and other layer of 150 mm thickness after laying of cable and punning down to 180mm to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note- Punned thickness only shall be measured and paid.
Material and labour for stone slab/patti, 40 to 50mm thick, rough dressed, Jodhpur stone slab cover in trenches for protection of cables, 25cm to 35cm wide and 80 cm long, laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Supply, assemble, erection and fixing of GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 26 Gauge complete all as specified and directed.
S&F supply diffusers/grilles/louvers of powder coated aluminium volume control dampers complete all as specified & directed by the Engineer-in-Charge.
Harsh Enterprises
Savitri Enterprises
VIKAS CONSTRUCTION CO.
RISING ELECTRICALS
Keystone Constructionare
M/S BUDHRAM BISHNOI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .