Loading…
Loading…
Tender ID
Tender Value
₹25 L
EMD Value
₹20,000
Closing Date
19 Feb 2026, 6:00 pmClosed
Ex.Eng (O&M) Valsad Rural Division
Tender for Erection & Maintenance and Labor works for Laying, testing & commissioning of 11/22 KV underground / Overhead XLPE cable (XLPE cable to be supplied by DGVCL), with cable End termination & straight through jointing kits (to be supplied by contractor) for Various feeder under jurisdiction of Dungri sub division under Valsad Rural Division under All Scheme.
275486
DGVCL/VALSAD-R DO/E-TENDER/2025-26/112
Open
Miscellaneous Works
Works
Valsad
8 documents required · 8 mandatory
₹1,180
Yes
DGVCL, Payable @ Valsad
₹20,000
Yes
11 Feb 2026
11 Feb 2026
11 Feb 2026
19 Feb 2026
11 Feb 2026
Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE
INCLUDING FIXING OF CROSS ARMS, CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD,
INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS AND NUMBERING
COMPLETE WITH COST OF PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG
INCLUDING EXCAVATION OF PIT AND REFILLING
OF EARTH, FIXING OFCROSS ARMS, TOP FITTING
CLAMPS ANTI-CLIMBING DEVICES, INSULATORS
2 9926000002 ETC. COMPLETE AND PAINTING OF FABRICATED No.
MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLES OF 9 TO 11 METERS
INCLUDING EXCAVATION OF PIT AND REFILLING
OF EARTH, FIXING OFCROSS ARMS, TOP FITTING
CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLE, FABRICATED
MATERIALS USED ON THE POLEAND NUMBERING
WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR
RAILWAY CROSSING ON BG/MG/NG LINE FOR
0.400/11/22KV OVERHEAD LINES I.E INCLUDING
EXCAVATION OF PIT & REFILLING OF EARTH,
FIXING CROSS ARMS, TOP FITTING
CLAMPS,ANTI-CLIMBING DEVICES DANGER
BOARD, INSULATORS ETC. COMPLETE AND
PAINTING OF STEEL POLES, FABRICATED
MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
5 9926000005 DANGER BOARDS,INSULATORS ETC.COMPLETE No.
AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF
TO 11 METERS.STEEL POLE INCLUDING
EXCAVATION OF PITS & REFILLING OFEARTH,
FIXING OF CHANNELS, SUPPORTING ANGLES,
CLAMPS,ANTI-CLIMBING DEVICES DANGER
BOARDS, INSULATORS ETC.COMPLETE &
PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH, HG FUSES OF 8 MTRS
200 KG PSC POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH,FIXING OF
CHANNELS SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES, DANGER BOARDS,
INSULATORS,DOFUSES ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDINGOF ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES, 9 TO
METERS STEEL POLES INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, FIXING
OFCHANNEL, SUPPORTING ANGLES, CLAMPS,
ANTI-CLIMBING DEVICES , DANGER BOARDS,
INSULATORS, ETC. COMPLETE AND PAINTING OF
POLES FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 8 METER,200KG PSC
POLE METERS POLES INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE, FIXING
9 9926000009 OF CHANNELS, SUPPORTING ANGLES,BRACINGS No.
CROSS ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USEDON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH
MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL
POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE,
10 9926000010 FIXINGOF CHANNELS SUPPORTING ANGLES, No.
BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING
DEVICES, DANGER BOARDS,CONDUCTOR AND
CABLE WIRING ETC. COMPLETE AND PAINTING
OF POLES FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTIONS OF
GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING EXCAVATION
OF PITS & REFILLING OF EARTH AS PER
STANDARD SPECIFICATION WITH STAY CLAMPS,
STAY WIRE, ANCHOR ROD, TURN BUCKLE,
EYEBOLT, GUY INSULATOR, CEMENT CONCRETE
BLOCK ETC. BUT EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING
COST OF CEMENT SAND METAL (1:2:4) AND
12 9926000012 WATER ETC. AS PER STANDARD CMT
SPECIFICATION.(cement Should be 53 grade)
used for Concreting.
ERECTION OF COIL TYPE EARTHING INCLUDING
COST OF COAL,SALT ETC. BUT WITHOUT COST
OF GI WIRE AS PER STANDARD
SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING
INCLUDINGCOST OF COAL SALT ETC. BUT
14 9926000014 WITHOUT COST OF PIPE/GIPLATE GI WIRE AS No.
PER STANDARD SPECIFICATION.(20kg solt+20kg
ERECTION OF STREET LIGHT FIXTURE COMPLETE
WITH CLAMPS, BRASS NIPPLE, BRASS HOLDER
15 9926000015 TECK WOOD BUSH,REFLECTORS FUSE, WIRING No.
ETC. AS PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
STRINGING OF(30mm2)ACSR/34MM@,55MM2
AAA CONDUCTOR for ALL TYPE OF CONDUCTOR
16 9926000016 (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT
LINES INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING
BINDING JUMPERING ETC.
PROVIDING SINGLE PHASE SERVICE
CONNECTION WITH PVC 2.5/4MM2 TWIN CORE
CABLE FROM TERMINAL POLE TO METERING
18 9926000018 POINT INCLUDING FIXING OF METER WITH No.
METER EARTHING COMPLETE WORK AS PER
STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE
CONNECTION WITH PVC 4MM2/10MM2 FOUR
CORE CABLE FROM TERMINAL POLE TO
19 9926000019 METERING POINT INCLUDING FIXING OF METER No.
WITH METER EARTHING COMPLETE WORK AS
PER STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT IN
HARD ROCK AREA FOR ERECTION OF POLE/ GUY
ETC. AS PER STANDARD SPECIFICATION OVER &
ABOVE NORMAL COST COVERED AGAINST
EXCAVATION OF PIT UNDER NORMAL SOIL FOR
ERECTION OF POLE,GUY, DOUBLE POLE
STRUCTURE EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON ROAD/
PROVIDING GUARDING OF LT LINES ON
ROAD/RAIL CROSSING.
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR
25 9926000025 ROAD CROSSING,HT LINE CROSSING AND No.
TELEPHONE LINE CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH
HG FUSES,TRANSFORMERS, LIGHTENING
ARRESTOR, DISTRIBUTION BOX. ON 8 METERS
200 KGAND PSC POLE INCLUDING EXCAVATION
OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING
OF CHANNELS, SUPPORTING ANGLES,BRACINGS
CROSS ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRUCTURES WITH
MOUNTING OFAB SWITCH , HG
FUSES,TRANSFORMERS, LIGHTENINGARRESTOR,
DISTRIBUTION BOX. ON 9 to 11 METERS RSJ
POLE INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING
27 9926000027 OF CHANNELS, SUPPORTING ANGLES,BRACINGS No.
CROSS ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
ERECTION OF PSC POLES OF 10 *270 KG
INCLUDING EXCAVATION OF PIT AND REFILLING
OF EARTH, FIXING OF CROSS ARMS, TOP
FITTING CLAMPS ANTI-CLIMBING DEVICES,
28 9926000028 INSULATORS ETC. COMPLETE AND PAINTING OF No.
FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 270 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS, SUPPORTING
ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
29 9926000029 DANGER BOARDS,INSULATORS ETC.COMPLETE No.
AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC ONE
CONDUCTOR FOR 11/22KV & LT LINES COND
INCLUDING FIXING OFINSULATORS, BINDING PER
JUMPERING ETC. KM
STRINGING OF DOG CONDUCTOR FOR 11/22KV
31 9926000031 & HT LINES INCLUDING FIXING OF INSULATORS,
BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES WITH
MOUNTING OF AB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 10 METERS
KGAND PSC POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE, FIXING
32 9926000032 OF CHANNELS, SUPPORTING ANGLES,BRACINGS No.
CROSS ARMS CLAMPS, ANTI-CLIMBING
DEVICES,DANGER BOARDS, CONDUCTOR AND
CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8
MTR PSC POLE) (WITH TRANSFORMER) WITH
CREDITING OF FABRICATION & TRANSFORMER
AT STORE & STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALLING OF TRANSFORMER CENTRE (8
MTR PSC POLE) (WITHOUT TRANSFORMER) WITH
36 9926000036 CREDITING OF FABRICATION AT STORE & No.
STACKING OF POLE SAFELY ON ROAD SIDE OR
CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25
SQ MM INCLUDING FITTING OF ALL ACESSARIES
I.E. SPECIAL DESIGN SUSPENSION / TENSION
CLAMP, FIXING OF CROSS ARM, LT SHACKLE
37 9926000037 INSULATOR ETC. FOR FIXING OF MESSENGER KM
WIRE AND TO PROVIDE SERVICE CONNECTION
ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF
MESSENGER WIRE AND TO PROVIDE SERVICE
CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E.
SPECIAL DESIGN SUSPENSION / TENSION CLAMP,
39 9926000039 FIXING OF CROSS ARM, BINDING TO PIN KM
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED & DIRECTED
BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95
SQ MM INCLUDING FITTING OF ALL ACESSARIES
I.E. SPECIAL DESIGN SUSPENSION / TENSION
40 9926000040 CLAMP, FIXING OF CROSS ARM, BINDING TO PIN KM
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ
MM+ 35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION /
TENSION CLAMP, FIXING OF CROSS ARM, LT
SHACKLE INSULATOR ETC. FOR FIXING OF
41 9926000041 MESSENGER WIRE AND TO PROVIDE SERVICE KM
CONNECTION ON AERIAL BUNCH CABLE BY
INSULATED PIERCEING CONNECTORS THROUGH
SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN
DISMENTALING OF RSJ (9/11 METER) POLE AND
CREDITING THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITHOUT
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF POLE
SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITH TRANSFORMER)
44 9926000044 WITH CREDITING OF FABRICATION AT STORE No.
AND STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80
SQ MM AND CREDITING FITTING OF ALL
ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM
+95 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM +
1*25 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
48 9926000048 DISMENTALING OF LT ABC OF 3*50 SQ MM KM
+1*25 SQ MM+1*35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO DEPARTMENTAL
DISMENTALING OF LT ABC OF 2*50 SQ MM
49 9926000049 +1*25 SQ MM+ 35 SQ MM AND CREDITING KM
FITTING OF ALL ACESSARIES TO DEPARTMENTAL
RESTRINGING OF ALL TYPE OF CONDUCTOR ONE
(EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT COND
LINES INCLUDING FIXING OF INSULATORS, PER
BINDING JUMPERING ETC. KM
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV COND
HT LINES INCLUDING , BINDING JUMPERING ETC. PER
LABOUR CHARGE FOR THE INSTALLATION OF
52 9926000052 NEW DTR METER. (METER WILL BE PROVIDED BY No.
LABOUR CHARGE FOR THE REPLACEMENT OF DTR
METER AND OLD METER SHOULD BE CREDITED
TO SDN STORE. (METER WILL BE PROVIDED BY
LABOUR CHARGE FOR PROVIDING CT COIL FOR
54 9926000054 DTR METER CONNECTION. (CT COIL WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT COIL
FOR DTR METER CONNECTION AND OLD CT PER
SHOULD BE CREDITED TO SDN STORE. (CT COIL CT
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR
METER (MMB WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR
57 9926000057 METER BOX. (METER WILL BE PROVIDED BY No.
PROVIDING / REPLACEMENT OF 1.5 SQ MM
58 9926000058 CORE COPPER CABLE 3.5 METER (CABLE TO BE No.
PROVIDED BY AGENCY)
LABOUR CHARGE FOR PER
PROVIDING/RECONNECTION OF TERMINAL TERMI
CONNECTION WITH PROPER SIZE OF LUGS. NATIO
(LUGS COST IS BORNE BY AGENCY) N
LABOUR CHARGE FOR THE SPOT READING OF
DTR METER WITH DETAIL SURVEY OF DEFECT IF
ANY. A DULY SIGN COPY BY SURVEYOR PERSON
OF AGENCY IN PRO-FORMA REPORT SHOULD BE PER
SUBMITTED TO SDN OFFICE.(* ONLY IF ALL DTR
PARAMETER OF VOLTAGE, CURRENT & LOAD AS
SHOWN IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF
DTR METER WITH DETAIL SURVEY OF DEFECT IF
ANY. A DULY SIGN COPY BY SURVEYOR PERSON
61 9926000061 OF AGENCY IN PRO-FORMA REPORT SHOULD BE
SUBMITTED TO SDN OFFICE. (DULY FILL PER-
FORMA IN FAULT CONDITION IN WHICH
READING PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING
METER BOX, PROVIDING & FIXING OF 1.5SQ MM
SINGLE STRAND 10 CORE ARMOURED COPPER
CABLE (3.5METER), TERMINATION IN METER &
COIL ETC.(METER, METER BOX, C.T./P.T. COIL
WILL BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING
METER BOX, TERMINATION IN METER & COIL
63 9926000063 ETC. (WITHOUT 10CORE COPPER CABLE) No.
(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance
not more than 0.75 mtr with 6 turns minimum on
XLPE Cable with single strand binding wire
(including cost of binding wire)
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV PER
Resistance) with using 95/120/150 sq.mm long SET
barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of bare
conductor by HT ABC conductor (DO bottom side PER
to transformer) after removal of semi conductor by SET
HT ABC (6 inch both side). HT ABC to be supplied
by DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage
(Pic) Type, Earth Electrodes for HT Feeder Pole
Having 2000 mm Electrode Length as per the
Tender Specifications and Drawing. (All Materials
Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage
(Pic) Type, Earth Electrodes for HT Feeder Pole
Having 3000 mm Electrode Length as per the
Tender Specifications And Drawing. (All Materials
Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip
having hot dip- galvanized-zinc coating of 80-100
microns without any joints or welding. Both the
end of the GI strip should be connected with GI
nut bolts and required fabrication work for giving
separate earthing connections to
69 9926000090 (1) Neutral of the transformer Meter
(2) MS structures of the transformer center
(Approximately 25 meter GI strip per transformer
- as per requirement and instruction of
Engineer in- charge) (All Materials will be supplied
Supply and Installation of uPVC standard make
Pipe of 1.25" diameter for covering GI strip with
UV protected Cable Ties of 550 X 7.6 mm size to
70 9926000092 bind with pole face(Approximately 25 meter uPVC Meter
pipe for GI strip covering per transformer centre -
as per requirement and instruction of Engineer in-
Supply & fixing of upto 33 kV Conducotr sleev for
Busbar to Drop out Fuse and Drop out fuse to
71 9926000093 Transformer H.T. including Busbar (12 mm sleev) Meter
as per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for
Busbar to Drop out Fuse and Drop out fuse to
72 9926000094 Transformer H.T. including Busbar(15 mm sleev) Meter
as per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-
flammable) material with Weather resistant, Non-
73 9926000095 conductive bird guard OD=300 MM, ID=33 MM, NO
Width =1.25 MM, one side cut from ID to OD. (All
Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e.
Re-useable boot (LT Side 1.1 kV) including LT (1.1
kV) insulating taps. All live part at LT side shall be
covered with fixing of LT insulating taps.
75 Nylon Net around Transformer Center
75.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated
75.3 9926000099 material for fitting nylon net shall be provided by Per TC
-::- SCHEDULE – ‘B 2’: FOR MAINTENANCE -::-
The Rates are inclusive of PF and Exclusive of GST
-::- SCHEDULE – ‘B 2’: FOR MAINTENANCE -::-
Item Code Details of works Unit FY 2024-25
(A) LINE MAINTENANCE
1 9924000001 Cutting of Tree branches surrounding HT/LT line
Replacement of old jumpers & providing new
2 9924000002 double jumpers with 8" binding [D Type] & No.
capsuling with PVC pipe etc
3 9924000005 Support pole for Stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per
pole in costle area with cleaning .
6 9924000008 Pin binding of conductor LT shakel insulator No.
Replacement of one/both disc.insulator at strain
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Refixing of V cross Arm No.
Replacement of V cross Arm (With Transportation
11 9924000013 Refixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting &
jumpering(ONE DO FUSE)
Numbering of pole with paint by preparing back
15 9924000017 ground of one color and have lettering(height 3" * No.
width 0.5") using stencil
16 9924000018 Fixing of MMB(1PH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (1ph.) meter for Urban area No.
19 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with
letter size height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with
letter size height 40mm* width 8mm)
Replacement of deteriorated Single phase Service
Fixing of new dist. Box with complete wiring
including clamps,nut bolts etc.
Reparing of guarding involving reshaping of
bearer wire cross lacing binding etc.
Painting of steel fabricated material of RSJ DO DP
structure with paint
Painting of steel fabricated material of RSJ pole
26 9924000028 mounted transformer double pole structure with No.
Painting of steel fabricated material of RSJ single
pole with paint
painting of steel fabricated material of PSC Single
pole (HT line) with paint
painting of steel fabricated material of PSC DO DP
double pole with paint
painting of steel fabricated material of PSC
30 9924000032 double pole at pole mounted transformer with No.
31 9924000033 Providing line seperater single phase No.
32 9924000034 Providing line seperater three phase No.
Replacement / Providing of stay insulator along
with adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist.
34 9924000036 Box with new up to 100KVA capacity & crediting No.
Replacement of deteriorated /providing LT dist.
35 9924000037 Box with new above 100KVA capacity & crediting No.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
Converting pin point to Shackle point including locatio
dismentaling & restringing etc. n
replacement of 11KV Pin insulator with providing
new double pin binding
replacement of 22KV Pin insulator by new 11kv
40 9924000042 pin insulator with spares & providing new double No.
Providing 11kv double disc insulators with binding
Replacement of existing 11kv conductor (all size) Cond/K
with new double pin binding M
Plumbing of PSC Pole with straightening at pin
Plumbing of PSC Pole with straightening at
Plumbing of tilted DP structure (PSC/RSJ/STP)
with refilling of stone Murrum etc.
Providing new 11kv AB /GO switch with
46 9924000049 fabrication and insulated colour code jumper, Set
binding, lugs etc
Replacement of old 11kv AB /GO switch with
providing new insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line per
with using PVC reel insulators etc pole
Labour charges for replacement /providing of
49 9924000053 MMB & service with all accessories for three phase No.
Labour charges for replacement /providing of
50 9924000054 MMB & service with all accessories for single No.
phase connection
Dismentalling of existing Dist.X'mer center(RSJ
51 9924000055 /STP POLE) 25/63/100/200 KVA with all No.
fabrication & creditig the old material to store
52 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No.
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole
& crediting to S/dn (1 ph.)
Dismentaling & removing of service line from pole
& crediting to S/dn (3 ph.)
Reconnection of service line complete with PVC
Reconnection of service line complete with PVC
Providing spiral type earthing by G.I. NO 8(weight
2kg -5mtr in length) with salt and coal 10kg each,
including pvc rigid pipe 20mm dia( 1.5mtr length)
to pass exposed part of G.I. wire at consumer
end with all materials, earth resistance should be
less than 2 ohms
Providing and fixing of signle core 1.5 sq mm
single strand copper insulated cable with cable
nail clip for spiral type earthing at consumer end.
The end of G.I. no 8 is to be connected by
connector with copper cable of which other end per
shall be connected to the earth terminal of meter meter
box. This item shall be used in location where
there is more distance between earth terminal
and earthing terminal of meter. (All materials
supplied by contractor)
9924000065 Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ
MM including fitting of all accessories i.e. special
design suspension / tension clamp, fixing of cross
arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling
charge of existing bare conductor and crediting in
to store & dismantling of service line from LT bare
conductor and to provide service connection on
Aerial Bunch Cable by insulated piercing
connectors through service connection box
complete as required & directed by Engineer in
9924000066 Stringing of LT ABC of 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM including fitting of all
accessories i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle
insulator etc. for fixing of messenger wire and
63 inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismantling
of service line from LT bare conductor and to
provide service connection on Aerial Bunch Cable
by insulated piercing connectors through service
connection box complete as required & directed
by Engineer in Charge.
9924000067 Stringing of 11KV ABC of 3*95 SQ MM +80 SQ
MM including fitting of all accessories i.e. special
design suspension / tension clamp, fixing of cross
arm, binding to pin insulator, preparing shackle
point, jumpers etc. and inclusive of dismantling
charge of existing bare conductor and crediting in
to store complete as required & directed by
Engineer in Charge.
9924000068 Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ
MM including fitting of all accessories i.e. special
design suspension / tension clamp, fixing of cross
arm, binding to pin insulator, preparing shackle
point, jumpers etc. and inclusive of dismantling
charge of existing bare conductor and crediting in
to store complete as required & directed by
Engineer in Charge
9924000069 Stringing of LT ABC of 2*50 SQ MM +1*25 SQ
MM+ 35 SQ MM including fitting of all accessories
i.e. special design suspension / tension clamp,
fixing of cross arm, LT shackle insulator etc. for
fixing of messenger wire and inclusive of
dismantling charge of existing bare conductor and
crediting in to store & dismantling of service line
from LT bare conductor and to provide service
connection on Aerial Bunch Cable by insulated
piercing connectors through service connection
box complete as required & directed by Engineer
Supply and fixing of suspension clamp to hold the
-::- SCHEDULE – ‘B 3’: FOR Underground -::-
LABOUR RATE FOR UNDERGROUND CABLE WORK (WITHOUT GST)
Item Code Description Unit FY 2024-25
Labour charge for excavation of cable
trench of 400mm width x 1200mm
depth, in any type of soil for laying of
1 9925000001 cable of size up to 240 mm2 (For Meter
additional cable 200 mm additional
width shall be considered i.e. half
trench length is to be considered)
Labour charge for excavation of cable
trench of 600mm width x 1200mm
depth, in any type of soil for laying of
2 9925000002 cable of size up to 240 mm2 (For Meter
additional cable 200 mm additional
width shall be considered i.e. half
trench length is to be considered)
Labour charge for excavation of cable
trench of 400mm width x 1500mm
depth, in any type of soil for laying of
3 9925000003 cable of size up to 240 mm2 (For Meter
additional cable 200 mm additional
width shall be considered i.e. half
trench length is to be considered)
Labour charge for laying of 11kV /
kV XLPE Cable of size up to
mm2 & preparation of sand layer
100mm thick, in the cable trench &
covering the cable with 150 mm dia
(Inner), thickness 25 mm,
meter long RCC half round muffs and
providing and fixing of 4inch width
4 9925000004 yellow colour polyethylene tape with Meter
printing "CAUTION ELECTRIC CABLE
BELOW" at 0.75 m depth from ground
surface after laying cable in trench.
This will provide indication that electric
cable is passing underground so as to
protect cable from mechnical injuries,
refilling the same, as per Instruction of
Engineer in Charge (EIC).
Labour charge for horizontal drilling
using Auger machine without
damage to surface road at max
mtrs depth & putting of 6.11 kg/cm2
class-4,Green color, 110mm O.D.
8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision)
and BIS certification and laying of
11KV/22KV XLPE cable of size up to
240 mm2 in HDPE pipe, as per Site
Condition (excluding cost of pipe). The
detail map obtained from HDD
machine and excell sheet(hard and
soft copy) indicating the respective
depth and distance from adjacent
landmark for each segment for HDD is
must required to be submitted. HDD to
be carried out at depth 1.5 mtrs to
mtrs as per site conditions and as per
instruction of EIC.
Labour charge for horizontal drilling
manually without damage to surface
road at max 2.0 mtrs depth & putting
of 6.11 kg/cm2 , class-4,Green color,
110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984-
1987(3rd revision) and BIS
certification and laying of 11KV/22KV
6 9925000006 XLPE cable of size up to 240 mm2 Meter
size, as per Site Condition (excluding
cost of pipe). The detail map and
excell sheet(hard and soft copy)
indicating the respective depth and
distance from adjacent landmark for
each segment of cable to be
submitted. Drilling to be carried out at
depth Minimum 1.2 mtrs to 2.0 mtrs
as per site conditions as per
instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5 mm thickness
H.D.P.E. pipe confirms to IS
and BIS certification for laying of
underground 11KV / 22KV XLPE cable
up to 240 mm2 size.
Labour work for RCC concreting on
disputed location and repairing of
damage portion of road crossing for
the work carried out for roads crossing
as well as concreting & muffing of
ploes including all materials (1:2:4)
Providing & fixing concrete stone route
marker of 300 mm width x 150 mm
thick x 650 mm height embedded
in earth at least 300 mm below &
mm above ground level respectively at
distance approx 50 meters along the
length of cable. The RCC concreting
(1:2:4)(all necessary maeterials will be
in bidder's scope) of route marker is to
be carried out 300 mm width x
mm thick x 300 mm below ground
level as per instruction of EIC. The
route marker should be with name of
company with approved yellow colour-
DGVCL. The distance from marker to
cable and cable depth with feeder
name etc., marked with arrow sign is
to be painted on it.The route marker is
to be fixed at location near to any
fixed permanent location (not
necessary to fix exact on top of cable)
as per instruction of EIC.
Erection of D.P. (double pole)
structure using 9 / 11 Mtr. RSJ
pole with cable connection
arrangement along with fitting of
10 9925000010 necessary fabrication for 11KV cable No.
including excavation of pit & refilling of
earth as per instruction of EIC.
(Exclusive of concreting & muffing of
Erection of Single pole structure
using 9 / 11 Mtr RSJ pole with
cable connection arrangement along
with fitting ofnecessary fabrication for
11KV/22 KV cable including excavation
of pit & refilling of earth as per
instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of D.P. (double pole)
structure using 8.0 Mtr. PSC pole
with cable connection arrangement
along with fitting of necessary
fabrication for 11KV cable including
excavation of pit & refilling of earth as
per instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of Single pole structure
using 8.0 Mtr PSC pole with cable
connection arrangement along with
fitting ofnecessary fabrication for
11KV/22 KV cable including excavation
of pit & refilling of earth as per
instruction of EIC. (Exclusive of
concreting & muffing of poles)
Labour charge for erecting of 11kV /
22 kV XLPE cable of size up to
mm2 on DP Structure with fixing
14 9925000014 of 02 Nos polymer cleats on top Per Job
and middle part.Polymer cleats, nut
bolts etc. fixing material to be
provided by contractor.
Providing & fixing of 6.11kg/cm2
class-4,Green color, 110mm O.D.
8.5mm thickness H.D.P.E. pipe
confirms to IS 4984 and BIS
certification on the erected DP
structure for the mechanical
protection of cable by inserting the
15 9925000015 cable inside HDPE pipe. The HDPE Per Job
pipe shall be erected in such a way
that 300mm shall be below the ground
level and the rest 2700 mm shall be
supported on the DP Structure with
01 No Polymer cleat.All materials
including polymer cleat and Nut bolt
to be provided by contractor.
Providing and fixing of pipe type
earthing from 80 mm dia class-B GI
pipe with pit to be filled with salt &
coke and construction of chamber as
per DGVCL Drg. No. dg /100 for DP
and cable. The earthing pit should be
joined with cable by G.I. strip of size
1” width & 2 mm thick. All material GI
pipe, Coke, Salt etc will be supplied by
Supply & fixing of heat shrink
type end terminations (outdoor)
17 9925000017 for upto 11kV 3C x 185 mm2 size No.
XLPE cable as per DGVCL technical
Supply & fixing of heat & shrinkable
end terminations (outdoor) for
18 9925000018 upto 22 kV 3C x 185 mm2 size XLPE No.
cable as per DGVCL technical
Supply & fixing of heat shrink type
end terminations (indoor) for
19 9925000019 upto 11kV 3C x 185 mm2 size XLPE No.
cable as per DGVCL technical
Supply & fixing of heat & shrinkable
end terminations (indoor) for
20 9925000020 upto 22 kV 3C x 185 mm2 size No.
XLPE cable as per DGVCL technical
Supply & fixing of heat shrinkable
straight through joint for upto
21 9925000021 11kV 3C x 185 mm2 size XLPE No.
cableas per DGVCL technical
Supply & fixing of heat shrinkable
straight through joint type for
22 9925000022 upto 22kV 3C x 185 mm2 size XLPE No.
cable as per DGVCL technical
Labour charge for excavation of
2100mm long x 1200mm wide x
mm deep joint pits for installation of
11kV / 22kV Straight through
joints as per instruction of engineer-
in-charge & covering the cable with
150 mm dia (Outer), thickness
mm, 1.0 meter long RCC half round
muffs & refilling same as per
instruction of EIC .
Providing and fixing of insulating bus
bar, made from 11KV/22KV XLPE
cable after removal of semi conducting
layer and applying of PVC heat
shrinkable anti-tracking core insulating
tubing (1.1KV), on both end terminal
using Aluminium long barrel heavy
duty up to 240 sq mm lugs,
Aluminium bus connector. Taping with
PG- clamp for bus conductor as per
drawing and as per instruction of EIC.
The Alluminium lugs and PG clamp
shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE
cable will be in scope of DGVCL while
all other materials will be in bidder's
Testing of cable at various points
and commissioning the feeder as per
25 9925000025 instruction of engineer-in-charge.Test No.
result shall be submitted by contractor
Preparation and submission of 6 (six)
copies, of complete layout
drawings with GIS mapping as per
actual cable routing showing road
crossing, HDPE pipe sleeving, jointing
locations, markers etc.
Providing and fixing of Sign Board at
junction point Made out of 2 mm
aluminium sheet size 750x300 mm
(2.5 x 1ft) rectangle, as per design,
pre treated with phosphate process
and acid etching coated with one coat
of epoxy primer and two coats of best
quality paints, refloctrorised with Hi-
Intensity retro – reflective sheeting as
per the latest and frame fabricated
from suitable size iron angle. The Sign
Board is to be fixed on the base
prepared from channel and bracing
angles which is grouted by means of
cement concreting of 1:2:4 for size of
300 mm dia x 800 mm height (500
mm to be grouted in ground). The
details to be displayed on sign board
will be given by In-charge Engineer.(a)
Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board
(Danger Board) on Distribution
Transformer Centers
Made out of 2mm aluminum sheet size
300x300mm (1x1ft) as per design,
pretreated with phosphate process
and acid etching coated with one coat
of epoxy primer and two coats of best
quality paints, reflectorized with Hi-
Intensity retro-reflective sheeting as
per the latest and frame fabricated
from suitable size iron angle. The Sign
Board (Danger Board is to be fixed at
the location as per instruction of In-
charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminum tag of
size 250 mm (L) x 75 mm (W) from
mm aluminum sheet along with
mm Dia aluminum binding wire for
fixing of aluminum tag near end
29 9925000029 termination joint at DP structure for No.
identifying the cable. The details of
feeder i.e. 11 / 22 KV with feeder
name should be punched on the tag
by letter punch of size 16 mm as per
instruction of In-charge Engineer.
Supply & fixing of heat shrink type
end terminations (outdoor) for
11kV 3C x 240 mm2 size XLPE cable
as per DGVCL technical specification
Supply & fixing of heat & shrinkable
end terminations (outdoor) for
kV 3C x 240 mm2 size XLPE cable as
per DGVCL technical specification)
Supply & fixing of heat shrink type
end terminations (indoor) for 11kV
3C x 240 mm2 size XLPE cable as
per DGVCL technical specification)
Supply & fixing of heat & shrinkable
end terminations (indoor) for
kV 3C x 240 mm2 size XLPE cable as
per DGVCL technical specification
Supply & fixing of heat shrinkable
straight through joint for 11kV 3C
x 240 mm2 size XLPE cable as per
DGVCL technical specification.
Supply & fixing of heat shrinkable
straight through joint type for
22kV 3C x 240 mm2 size XLPE cable
as per DGVCL technical specification
Installation, Testing and
commissioning of 11 KV,630 A SCADA
Compatible, RRL type- 3 Way RMU
36 9925000038 including Two numbers of earthings as No.
per Drawing (material is in bidder's
scope) and as per DGVCL Technical
Installation, Testing and
commissioning of 11 KV,630 A SCADA
Compatible, RRLL type- 4 Way RMU
37 9925000039 including Two numbers of earthings as No.
per Drawing (material is in bidder's
scope) and as per DGVCL Technical
Installation, Testing and
commissioning of 22KV,630 A SCADA
Compatible, RRL type-3 Way, RMU
38 9925000040 including Two numbers of earthings as No.
per Drawing (material is in bidder's
scope) and as per DGVCL Technical
Installation, Testing and
commissioning of 22KV,630 A SCADA
Compatible, RRLL type-4 Way, RMU
39 9925000041 including Two numbers of earthings as No.
per Drawing (material is in bidder's
scope) and as per DGVCL Technical
Construction of plinth for 11KV,
RRL type- 3 Way (i.e. Two numbers
of Isolator & One number of Breaker)
40 9925000042 Ring Main Unit as per DGVCL's No.
technical specification mentioned in
drawing no: Drg. 11kv-01. All required
material will be supplied by contractor.
Construction of plinth for 11KV,
RRLL type- 4 Way (i.e. Two
numbers of Isolator & Two number of
Breaker) Ring Main Unit as per
DGVCL's technical specification
mentioned in drawing no: Drg. 11kv-
02. All required material will be
supplied by contractor.
Construction of plinth for 22KV,
RRL type- 3 Way (i.e. Two numbers
of Isolator & One number of Breaker)
42 9925000044 Ring Main Unit as per DGVCL's No.
technical specification mentioned in
drawing no: Drg. 22kv-01. All required
material will be supplied by contractor.
Construction of plinth for 22KV,
RRLL type- 4 Way (i.e. Two
numbers of Isolator & Two number of
Breaker) Ring Main Unit as per
DGVCL's technical specification
mentioned in drawing no: Drg. 22kv-
02. All required material will be
supplied by contractor.
Modifications e.g. Providing and fixing
of Terminal protectors i.e. Re-use able
boot (HT Side 11/22KV, LT Side
1.1KV) including 11/22 KV insulating
taps and L.T.(1.1 KV) insulating taps
,Busbar, Tapping from Bus Bar
(11/22 KV XLPE cable) through P.G.
Clamp for H.T. Jumper to D.O. Fuse to
bushings of Transformer Center,
providing & Fixing of jumper and
44 9925000046 providing & fixing of Heat Shrinkable No.
Anti Tracking Core Insulating Tubing
(Insulation Level 11/22 KV) in H.T.
jumper , Clamping arrangement of
cable support frame on both side of
existing Over Head type Distribution
Transformer to utilize in Under Ground
cable network as per drawing & as per
instruction of Engineer in charge. All
live parts i.e. PG-Clamp, connections
of D.O. fuses, HT bushings etc. shall
be covered with fixing of 11/22 KV HT
insulating tapes. (11/22 KV XLPE cable
will be in scope of DGVCL while all
other materials will be in bidder's
Laying of any size of 11/ 22 KV XLPE
45 9925000047 /PILC Cable in readymade trench or in
Labor charges for Lying of O/H XLPE
cable pole to pole
Supply of 150 mm Dia (Inner),
47 9925000064 thickness 25 mm, 1.0-meter long RCC No.
half round pipe
Total of schedule B1, B2& B3
(+)_______%Above, (-)_______%Below, Rate to
Net Total of Schedule ‘B1, B2& B3:
Amount in Words: (Twenty-Five Lacs Only)
1. Whatever Steel Material removed after replacement should be credited to Store.
2. The rates are inclusive of PF & Work Contract Tax & excluding of GST.
3. Contractor has to carry out work under Dungri Sub-Division under Valsad-Rural
4. DGVCL will provide 1ph & 3ph LT Ariel Bunch Cable 11/22kv HT ABC with necessary
accessories to the contractor.
5. The rates are inclusive of dismantling charges of existing bare conductor and crediting
in to store & dismantling of service lines from LT bare conductor and to provide service
connections on ABC by insulated pierce connectors through service connection box.
6. The contractor has to collect all the required materials from DGVCL store as well as
credit the dismantled material to the DGVCL store at their cost.
7. DGVCL will provide key material like M.S. materials, ABC/Bare conductors, PSC/RSJ
Poles, Insulators, Fabricated materials etc. to the contractor.
8. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding
rods confirming to the relevant ISI specification and as directed by Engineer in charge.
9. Necessary electricity connection for fabricated items shall be provided by DGVCL on
payment of required charge for connection & electricity bill of the same shall be paid by
10. All the rates are inclusive of PF and Exclusive of GST applicable time to time.
11. All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ
poles & steel fabricated materials of RSJ/PSC poles is must.
(b) Two coats of approved ISI mark red oxide (primer) are to be properly painted
for the RSJ poles & steel fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent
quality silver paint) are to be properly painted on to the RSJ poles & steel fabricated
materials of RSJ/PSC poles.
Executive Engineer (O&M)
DGVCL Valsad Rural Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Schedule A.pdf
2. Bid Document.pdf
4. Detail Technical Specification.pdf
Amend an Arbitration Clause.pdf
GENERAL TERMS and CONDITIONS.pdf
Letter to All DISCOMs for Ratified Common UG Tender Conditions.pdf
Notice Inviting Tender.pdf
Schedule-B.pdf
TECHNICAL BID.pdf
TECHNICAL SPECIFICATIONS FOR THE WORK.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .