Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹41.0 L+₹11.6 L (39.2%)Rejected-Finance | L2 | Rejected-Finance Not Meeting eligibility criteria | |
| 3 | L3₹41.9 L+₹12.4 L (42.1%)Rejected-Finance RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | L3 | Rejected-Finance Not Meeting eligibility criteria | |
| 4 | L4₹44.8 L+₹15.3 L (52.1%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L4 | Rejected-Finance Not Meeting eligibility criteria |
Tender Value
₹55.6 L
EMD Value
₹1.1 L
Closing Date
28 Dec 2022, 6:20 pmClosed
Shri T Rajasekharam,IDSE
HQ Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
REPAIRS REPLACEMENT AND IMPROVEMENT TO HT OVERHEAD LINE UNDERGRAOUND CABLE GOD TRANSFORMERS VCB s AND RMU AND ALLIED WORKS IN WEST AREA UNDER GE DEHU ROAD
2022_MES_566624_1
85036/DR/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Dehu Road
Please ref tender documents
7 documents required · 7 mandatory
₹1,000
Garrison Engineer Dehu Road
₹1.1 L
8 Mar 2023
1 Dec 2022
29 Dec 2022
1 Dec 2022
28 Dec 2022
16 Dec 2022
1 Dec 2022 - 21 Dec 2022
Amount
Excavation in trenchesin Soft / loose soil not exc 1.5m wide and not exc 1.5 m in depth for laying cable,erection of poles,stay and pipe line,complete allas directed.
Excavation in trenchesin Hard / dense soil not exc 1.5m wide and not exc 1.5 m in depth for laying cable,erection of poles,stay and pipe line,complete allas directed.
Excavation in trenchesin soft/disintegrated soil not exc 1.5m wide and not exc 1.5 m in depth for laying cable,erection of poles,stay and pipe line,complete allas directed.
Excavation in trenchesin Hard Rock soil not exc 1.5m wide and not exc 1.5 m in depth for laying cable,erection of poles,stay and pipe line,complete allas directed.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
Taking up the un reinforced precast concrete cable cover of any type from the existing trenches all as specified and directed by Engineer -in-Charge.
Supply and laying un reinforced precast concrete cable cover class HT, type-I, flat size 300 mm x 180 mm x 40 mm laid in trenches all as specified and directed by Engineer -in-Charge.
Laying only un reinforced precast concrete cable cover as obtained from item no 7.00 here n before of class HT, type-I, flat size 300 mm x 180 mm x 40 mm laid in trenches.
Supply, spreading in trenches sand cushioning with dry and cleover and under the cable for protection of cable,complete all as directed(Punned thickness shall be measured for payment)Note: Thickness of sand cushioning shall be measured after punning and consolidating of sand.
Taking out old unserviceable underground cable HT/LT,PVC insulated, PVC sheathed armored heavy duty aluminum conductor form pole, wall and trenches etc after disconnecting complet all as directed.
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 70 sq. mm.Make :- Havells/ Polycab/ Gloster
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 95 sq. mm.Make :- Havells/ Polycab/ Gloster
Supply and laying XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 120 sq. mm.Make :- Havells/ Polycab/ Gloster
Relaying HT cable 11000/22000 volt grade of any size any type as obtaing from item no-11 here in before all as directed.
Relaying LT cable 1100 volt of any size any type as obtaing from item no-11 here in before all as directed.
Taking out unserviceable pipe ,supply and laying GI pipe medium grade 80 mm dia for protection of cable all as directed.Make: TATA,Jindal,Indian Tube company
Taking out unserviceable pipe ,supply and laying GI pipe medium grade 100 mm dia for protection of cable all as directed.Make: TATA,Jindal,Indian Tube company
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm to 95 sqmm.
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm.
Taking out the unserviceable Cable joint,supply and fixing Cable jointing kit for 22 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm
Taking out the unserviceable Cable joint,supplu and fixing Cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm
Taking down unserviceable Aluminium cable lug 120/185 sqmm and supply with fixing the same all as directed.Make:-Dewel,M-Seal
Taking down unserviceable Aluminium cable lug 95 sqmm and supply with fixing the same all as directed.Make:-Dewel,M-Seal
Taking down unserviceable Aluminium cable lug 70 sqmm and supply with fixing the same all as directed.Make:-Dewel,M-Seal
Dismantling and taking out old unserviceable steel tubular pole of any size and type after breaking PCC, incl necessary earth work and removing from site complete all as directed.
Dismantling and removing ACSR conductor of any type from pole after disconnecting all connection on insulator etc all as directed.
Dismantling cross arms of MS channel or angle iron section etc complete and setting aside for reuse/replacement with in 50 mtr all as directed.
Dismantling stay assy incl demolition of concrete,stay strand and keeping aside for reuse/replacement all as directed.
Dismantling the insulators of any type/size/voltage.Testing with magar and keeping aside serviceable insulator for refixing all as directed.Note: Refixing/Replacement of new items measured and paid in respective seperate items.
Supply & Erect Steel sewaged tubular poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified of type 410 SP-55 (11.0 Mtrs Long) including Painting with two coats of aluminium paint over a coat of red oxide primer complete after preparation of steel surfaces and writing letters / Numbers not more than 10 cm high by Black paint all as directed.. .
Supply & fixing ACSR conductor of any type and Size incl binding, on insulator all as directed
Restringing/Fxing only ACSR conductor of any type and Size incl binding wire, retrived from item here in before cpmplete all as specified and as directed by engineer in charge.
supply and fixing stay assembly complete with 16mm dia stay Rod and accessories as shown in Electrical plate No-1(loop type Insulator, stay clamps, excavation and Concrete measured separately) complete all as specified and as directed
Supply and fix galvanized stay strand 7/2.24 mm all as specified and directed.
Fixing only retrieved serviceable cross arms, bracing, support, clamps ,retrived from item here in before cpmplete all as specified and as directed by engineer in charge.
Supply and fix cross arms, bracing, support, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shapes or size including one primer coat, one under coat and one finishing coat all as directed.
Supply and fix pin type insulator, Polymetric/poreceline , vitreous, white/brown including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut 150 mm height 150 mm dia 11000 volt grade all as specified.
Fixing only serviceable pin type insulator, pin type insulator any type and size obtained against item here in before complete all as specified and as directed by engineer in charge.
Supply and fix loop type insulator, Polymetric, proceline white/brown with over all dimension 90 x 140 mm clearance of hole 25.5 mm all as specified and directed.
Supply and fix disc type insulator Polymetric/ poreceline vitreous,/Polymetric 145 mm height and 255 mm dia ball and socket type white/brown of 11000 volt grad all as specified .
Fixing only serviceable disc type insulator any type and size, obtained against item here in before complete all as specified and as directed by engineer in charge.
Supply & Fixing lightening arrester for out door use, station class H.T. 11000 Volt grade 10 KA complete all as specified and directed.Make:Oblum,BHEL,CG
Taking down unserviceableGOD,and supply and fixing Triple pole, mechanically operated mounted on insulator and steel frame, with operating mechanisum worked from ground level GOD 11 KV heavy duty, for current rating 400 amps all as directed.Make:Pactil,Jaipuria,HEI
M & L for DO fuse single pole 11000 volt grade up to 25 Amps complete all as specified and as directed by engineer in charge.
M & L for DO fuse single pole 11000 volt grade up to 25-50 Amps complete all as specified and as directed by engineer in charge.
Taking down unserviceable danger notic board,Supply and FixingDanger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, forHT, 25x20cm size
Taking down unserviceable connector supply and fixing Vice type connectors consisting of two brass plates,and two steel bolts and nuts for 2 conductors of qual or unequal sizes, for non-tension connections 'including treatment of connector and ACSR conductor suitable size 10 to 13 mm with conducting jelly all as directed.
Painting of HT Electrical pole of any height including cross arm, clamp etc with two coats of aluminium paint over a coat of red oxide primer complete after preparation of steel surfaces and writing letters / Numbers not more than 10 cm high by Black paint all as directed.
M&L for earthing complete with galvanised Steel earth plate electrode of size 600x600x6mm thick burried directly in ground with (earth pit not less than 2.25mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire of size 4.0 mm dia by means of nuts, bolts, check nuts, washers of galvanised Iron or Steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion all complete.
Supply and fix earth strip of size 25 x 4 mm galvanised iron strip fixed to wall/over head reservoir on batten or recess or chases or buried inground or drawn in conduit /pipe fixed on poles insulated as per Engr-in-Charge.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe ofrequired size all as specified and directed by Eng in Charge. Note:- Item rate include necessary excavation on both sides of road.
Cutting & trimming of tree trunks/ branches having grith not more than 50 mm, falling on or likely to fall on LT over head electrical line for clearence of 3.0 meter on ground from the nearest conductor/pole /earth etc .& disposal of unservicable materials to distance not exc.50 mtrs .& clearing of site all as directed by Engr -in-Charge. Note:- The distance between two poles is measured as one span.
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
M & L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
S&F in repair GI Wire 4 mm dia fixed on LT/HT Poles
Taking down and Supply and fixing insulating rubber mating chequare plate made out having electrical resistance of size 1000mmx2000mm with thickness 20mm suitable for use 22 KV working voltage,dielectric strength 40 kv with working temperature up to 50 degree centrigate complet all as directed.
M & L to find out fault location in 11000 V /415 V UG Cable of any size by using cable fault locator directed by all as specified and directed by Eng in charge. Note:-Contractor must bring cable fault locator at site within 24 hours of intimation otherwise recovery @ Rs 1000/Hr will be charged after 24 hours.
Material & labour for cable route indicator made out of Aluminium plate 80 MM dia, 6 mm thick & fixed over M.S angle iron of size 30 x 30 x 6 mm, 60 cm in length duly painted with Synthetic enamel BLUE paint suitable for LT cable all as specified & including embedded in PCC (1:3:6) type C1 of size 30 x 30 x 20 cm in ground complete all as specified.
Taking down the old transformer oil and testing the TRANSFORMER OIL CLASSIFICATIONS* with the following from NABL accord test lab (i)ACIDITY OR NEUTRALISATION NUMBER(NN) (ii) INTERFACIAL TENSION(IFT).(iii) IFT-NN Relationship and other test complet all as directed.
Disconnections the HTand LT connection 0f 11/0.44 KV step down outdoor typeTransformer of capacity 50KVA TO 250 KVA. and transportation to workshop Opening the top cover and taking out the core and drain out the unserviceable oil.Discalling the oil tank, removing all sludge and acide cleaningalso. Removing the all sladge,carbon ,acid from the core and coil,dry the coil and heatvarnishing the same.Decarbonizing the all connected parts.Filling new transformar oil,refixing the top cover,top up the transformer oil and dehydration and filteration the oil upto dielectric strength 30 KV,and testing, including painting with two coat of synthetic enamel paint complete including reinstallation in original position and reconnection all as directed.Note: (i) Cost of Material and labour, for various parts will be paid seperately under respective items of Sch-"A".However cost of labour towards dismelting,assembling ,tools and lifting arrangement,transportation is deemed to be including in this items.Cost of sundry items viz cover bolt,plug cap,screws,washer,air release plug etc deemed to be included in quoted rate.(ii)New oil to be measured and paid in respective items seperately..(iii) Testing and commissioning of transformer after repair and submitting of test report with satisfactory result to be submittted.
Serviceaing and maintanence 22/0.44 KV step down outdoor typeTransformer of capacity 500 KVA after necessary disconnections the HT connection at site .Opening the top cover and repairing the Leckage,replace the silica gel,Decarbonizing the all connected parts,refixing the top cover,top up the transformer oil and dehydration and filteration the oil upto dielectric strength 30 KV,and testing, including painting with two coat of synthetic enamel paint complete all as directed.Note: (i) Cost of Material and labour, for various parts will be paid seperately under respective items of Sch-"A".However cost of labour towards dismelting,assembling,Joint inspection and identifyin the fault,tools and lifting arrangement,transportation is deemed to be including in this items.Cost of sundry items viz cover bolt,plug cap,screws,washer,air release plug etc deemed to be included in quoted rate.(ii)Filtration/centrifuging of old transformer oil to be measured and paid seperately.(iii) Addition/Replacement of Transformer oil if required will be measured and paid seperately.(iv) Testing and commissioning of transformer after repair and submitting of test report with satisfactory result to be submittted.
All as item no 67 here in before but step down transformer 11/0.44KV of capacity 400 KVA.
All as item no 67 here in before but step down transformer 11/0.44KV of capacity 250 KVA.
All as item no 67 here in before but step down transformer 11/0.44KV of capacity 160 KVA.
All as item no 67 here in before but step down transformer 11/0.44KV of capacity 100 KVA.
All as item no 67 here in before but step down transformer 11/0.44KV of capacity 50 to 75 KVA.
Supply only breather assembly of approved make filled with silica gel suitable for transformer of capacityupto 500 KVA Volt Distribution transformer.
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 250 KVA to 500KVA.
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 100 KVA to 160KVA.
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 50 KVA to 75 KVA.
Supply only brass spindle for terminal on LT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 250 KVA to 500KVA.
Supply only brass spindle for terminal on LT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 100 KVA to 160KVA.
Supply only brass spindle for terminal on LT side threaded complete with nut, washers etc of suitable dia for transformer of capaicty 50 KVA to 75 KVA.
Supply only ceramic bushing and Gasket on LT side of transformer of capacitie 250 KVA to 500 KVA 22/11/0.44 KV Distribution transformer (Make : Mysore Potteries/BHEL/ :-
Supply only ceramic bushing and Gasket on LT side of transformer of capacitie 50 KVA to 160 KVA 11/0.44 KV Distribution transformer (Make : Mysore Potteries/BHEL/ :-
Supply only ceramic bushing and Gasket on HT side of transformer of capacitie 250 KVA to 500 KVA 22/11/0.44 KV Distribution transformer (Make : Mysore Potteries/BHEL/ :-
Supply only ceramic bushing and Gasket on HT side of transformer of capacitie 50 KVA to 160 KVA 11/0.44 KV Distribution transformer (Make : Mysore Potteries/BHEL/ :-
Supply and fixing in replacement of complete gasket (Cock sheet) 6 mm thick complete of capacity of 250Kva to 500 Kva transformer including conical rubber bush:-
Supply and fixing in replacement of complete gasket (Cock sheet) 6 mm thick complete of capacity of 50 KVA to 160 KVA transformer including conical rubber bush:-
M&L for on load filtration/configuration/desludging(in situ) of old carbonized insulating oil(Transformer Oil), filled in transformers under service(Both the power and distribution type) of various capacities and rating outdoor type(22/11KV,22/0.44KV,11/0.44 KV) located and installed at different places under GE Dehu Road area by means of filtration plant(Machine), electric motor driven to improve the dielectric strength up to 66 KV including filling/topping up insulating oil and mentaining data of fil on transformer.Note:(i) Testing of di-electric strength of insulating oil befor and after filtration shall be carried out in presence of e-in charge/GE.(ii) T&P /Labour required for filtration testing shall be arranged by the contractor at his own cost.(iii)New Transformer oil topped shall be measured and paid seperately.
Supply Transformer oil in pack container complet all as directed
Disconnecting all in coming and outgoing cables, removing the transformer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractor's workshop, carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and out going cables by properly crimping using lugs of suitable size taping the bushes / bus bars, using insulation tape and testing complete of capacity up to 500 kva all as directed . Note:- (i) Rate including allinsulating material for winding coil (ii)Gasket set, LT/HT side ceramic bushing, spindle for HT/LT side , rewinding,dehydration of oil shall be measured and paid separately in respective items.(iii)Testing of Transformer in workshop complet.
Supply and winding of 22/11//0.433 KVHV coils,using new copper wire/strip of proper size injcluding insulating materials (double insulation)as per existing size of core of transformer complete incl heating , varnishing all as directed .
Supply and winding of 22/11//0.433 KV LV coils,using new copper wire/strip of proper size injcluding insulating materials (double insulation)as per existing size of core of transformer complete incl heating , varnishing all as directed .
Supply the following items for servecing /repairing the HT 22 KV VCB for Indicator LED Lamp,(Read,Yellow,and Orange)110 V,AC,for HT 22 KV VCB Make - L&T
Closing Coil,110V,DC,suitable for HT 22 KV VCB Make - Siemens
Shunt trip coil on,24V ,DC,suitable for HT 22 KV VCB Make - Siemens
Control Fuse ,HRC,2/4/6 Amp,suitable for HT 22 KV VCB Make - L&T
Motor cutoff switch,suitable for HT 22 KV VCB Make - Siemens
HT Tape
Monoplast Tape
Digital volt meter 96x96mm,0-500V,Aux supply 110V,AC,suitable for HT 22 KV VCB Make - Siemens
Digital Ammeter Make - Conzerve DM - 3258 /DM 3310 suitable for HT 22 K V VCB
Auxilary switch on block magnet,suitable for HT 22 KV VCB Make - Siemens
Male &Femal Spout assembly,suitable for HT 22 KV VCB Make - Siemens
CT for VCB,suitable for HT 22 KV VCB Make - Siemens
Over Current realy suitable for HT 22 KV VCB Make - Siemens ERL Modle No - PC:05821,In 4/5 Amp , frquency - 50 Hz , Vx - 43-280V DC/110V AC
Master trip relay suitable for HT 22 K V VCB Make - ERL /EASUN REYOLLE operating voltage -110 Volt DC .
Digital VAF meter , EM 6400 suitable for HT 22 K V VCB
Contact arm assembly from HT 22kV VCB suitable for Siemens braker
Star Electrical
Shri Sai Electricals
Rama Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .