| 1 | L1₹11.7 LAccepted-AOC VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹11.7 L | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND REASONABLE |
| 2 | L2₹12.1 L+₹34,364.40 (2.93%)Rejected-Finance HOUSE NO 413 MAGADH COLONY SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | ₹12.1 L+₹34,364.40 (2.93%) | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
| 3 | L3₹12.5 L+₹73,158.60 (6.23%)Rejected-Finance | ₹12.5 L+₹73,158.60 (6.23%) | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
| 4 | L4₹12.7 L+₹90,567.40 (7.71%)Rejected-Finance Q 49 NEAR DEOGHAR COLLEGE MAIN GATE PO PS DEOGHAR JH 814112 | DEOGHAR | DEOGHAR | JHARKHAND | 814112 | ₹12.7 L+₹90,567.40 (7.71%) | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
2 Dec 2023, 6:00 pmClosed
GARRISON ENGINEER
GE RAMGARH CANTT
REPAIR TO WATER PROOFING SUNKEN FLOOR, REPLACEMENT OF INTERNAL WATER SUPPLY PIPE LINE AND SANITARY FITTINGS IN MD AND OTM ACCN AT SRC, MH, STN HQ, MDC AT RAMGARH CANTT
2023_MES_626812_1
8300/3199/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH
₹34,000
Yes
6 Jan 2024
4 Nov 2023
9 Dec 2023
4 Nov 2023
2 Dec 2023
18 Nov 2023
Amount
M&L for demolition of cement concrete (un reinforced) in ground floor, terrazo tiles floor & paving of exceeding 15cm thickness (above or below ground level ) by mechanical tools and removing excavated material outside of MoD land, complete all as directed by Engr-in-Charge.
M&L for PCC (1:5:10) type E-2 (using 40mm graded brick aggregate ) as in sunken portion, sub base,etc complete all as specified and directed.
M&L for 10 mm thick plastering in cement mortar 1:3 on concrete / brick surfaces mixed with water proofing compound as per manufacturer instructions, finished, even and smooth without using extra cement over roof / sunken slab /wall complete all as specified and directed. Note:Water proofing compound will be measured and paid seprerately under respective item of "BoQ".
M & L for 30 mm thick plain cement concrete 1:2:4 ,type B-0 (using 12.5mm graded crushed stone aggregate) mixed with integral water proofing chemical compound, mixed in proportion 200 milli litre per 50 Kg of cement as in padding, benching, sunken portion etc., on roof surface for correcting/making proper slope on roof, etc.,complete all as specified and directed.
S & F for 150 micron thick polythene film pasted with help of adhesive shall be provided over treatment complete all as specifed & as directed.
S &F in repair 50mm bore tubes light grade galvanised with all fittings laid in floor as in spout pipe, etc complete all as specified .
Supply only water proofing compound ISI marked. complete all as specified and directed.
M & L for application of water proofing treatment of sunken portion of WCs ,bath room etc., to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying two coat of Shalimar supercreten/Nitobond/Dr Fixit of make as approved in technical instructions. (c) Fosroc's complast X421 IC@ 130ml per bag of cement including a bonding coat of Fosroc's Nitto bond AR cement slurry /STP No. 1 liquid @200 ml per bag complete (d) This treatment shall be allowed to air curefor four hours followed with water tightness by ponding for 72 hours and rectify defect,if any till elimination of defects.
Taking down PVC chowkhats or frames with shutter (without taking off shutter from the frames) of any description not exceeding 1.5 Sqm each, complete all as specified and directed by Engineer-in-Charge .
S & F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by Engineer-in-Charge.
S & F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS framed shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement complete all as fixing in the frame at site as per specification and drawing complete all as specified and as directed.
S & F 100mm size butt hinges medium weight cold rolled stainless steel (SS) complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed.
S&F 150 mm aluminium alloy handles of extruted section type, anodised complete all as specified & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L coloured ceramic glazed tiles 350 x250 x 7mm / 450 x 350 x 7 mm thick as in vertical surface such as dado/skirting etc over & including 10 mm thick rendering in CM 1:4, set & jointed in neat cement slurry & pointed in white or coloured cement slurry & pointed in white or coloured cement complete all as specified and directed.
M&L for joint free non skid coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc., over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
M&L for coloured non digital paver Vetrified exterior floor tiles 10 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar (1:6) etc complete all as specified & directed.
Taking up or down steel tubing and connections of 15 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed.
Taking up or down steel tubing and connections of 20 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F for GI water tubing medium grade, ISI marked, galvanised, 20 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for brick walls and making good the surface in cement mortar 1:3 complete all as specified & directed.
S&F vitreous China WC squatting pan " Orissa Pattern" of size 580 mm X 440 mm white with integral foot rest including cast iron "P" or "S" trap, front or back inlet and making connection to trap & to flushing cistern complete including taking down existing pan & making good disturbed surface complete all as specified & directed
S&F in repair vitreous China wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat cover including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. Note : Plastic seat cover shall be measured separately as Supply only as considered under respective items.
Supply only plastic water closet seat closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S & F in repair vitreous China wash basin, any colour, flat back size 550 mm X 400 mm including 32mm brass chromium plated waste coupling , 32 mm bore PVC waste pipe, chromium plated Grating including cutting for & pinning in ends of bracket or errecting bracket & PCC 1:2:4 ,type B-1(using 20 mm graded crushed stone aggregate) for embedding brackets & making good disturbed surface with CM 1:3 complete all as specified and directed.
S & F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including all standard accessories such as inlet ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed.
S & F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed
S & F in repair wall mounted PVC cabinet mirror of size 450 mm x 350mm as approved by GE complete all as specified and directed
S&F in repair aluminium anodised towel rail , 20 mm dia ,D-type 600 mm long with bracket between flanges fixed with and including chromium plated brass screw & wooden /plastic cleats complete set all as specified and directed.
S&F in repairs15mm dia pillar tap cost copper alloy fancy type long body with capstan heads chromium plated screwed down high pressure with or without letered "Hot or Cold" high pressure with long screwed shanks & fly nuts screwed for iron pipe etc complete all as specified and directed
S & F in repair angle stop valve of 15mm bore, chromium plated fancy type screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and directed.
S & F in repair, 15mm bore bib taps ( weight not less than 400 gm) cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
S & F in repairs brass chromium plated shower rose with swivel joints, 125 mm size in square with chromium plated long shank arm including fixing to steel pipe or union complete all as specifed & as directed.
S & F in repair for PVC connection pipe of 15 mm dia and 45 cm long to WHB and flushing cistern complete all as specified and directed.
S&F rotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/ vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 25 mm bore GI nipple and 20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) including taking down of existing tank complete all as specified and directed.
S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/ vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 25 mm bore GI nipple and 20 mm bore ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms) including taking down of existing tank complete all as specified and directed.
S&F in repair for Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as specified and directed .
S&F in repair for Gun-metal, globe or gate valves 15mm, with iron wheel head, screwed both ends for iron pipe etc comlete all as specified and directed .
Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off from site etc complete all as specified and directed.
M&L for Brick work with sub class bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement.
M&L for preparation of newly plaster surface of wall and applying two coats of cement base paint over a coat of alkali primer including necessary scaffolding complete all as specified & as directed.
Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc & removing the debris from the premises upto 500 m from the MOD land complete all as specified and directed.
Taking down complete existing roof /parapet treatment any thickness including plastering, tiles ,leaping plaster of any thickness cuting & up rooting tree roots/Vegitable growth & removing the debris from the premises upto 500 m from the MOD land including cleaning/ washing down and keeping surfaces clean complete all as specified and as directed.
M & L for cutting 75 mm wide and 65 deep in brick wall/PCC block/RCC surface any location shaping horizontal face groove filled with PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) with and including chemical compound mixed in proportion 200 mili litre per 50 Kg of cement or as per manufacturer's instructions laid when concrete is still green, complete all as specified and as directed. Note:Water proofing compound will be measured and paid seprerately under respective item of "BoQ".
M & L for brushing neat cement slurry (@ 3 Kg of cement per Sqm) for bonding of old concrete surface to new concrete, complete all as specified and as directed.
M & L for plain cement concrete 1:2:4 ,type B-0 (using 12.5mm graded crushed stone aggregate) mixed with integral water proofing chemical compound, mixed in proportion 200 milli litre per 50 Kg of cement as in padding, benching, sunken portion etc., on roof surface for correcting/making proper slope on roof, etc.,complete all as specified and directed .(Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
M&L Rendering 10 mm thick in cement mortar 1:4 on concrete / brick surfaces with liquid water proofing compound @ 200 ml/50 kg per bag of cement or as per manufacturar instruction finished even and smooth without using extra cement over roof / sunken slab /wall complete all as specified and directed (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
M & L for application of water proofing treatment using APP modified roof membrane over non accessible/non approachable RCC roof slab /chajjah/canopy /parapet wall( horizontal /vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying approved bituminous based primer( conforming to IS: 3384-1995) @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface & hot blown grade bitumen 85/25softning point 115 degree C @ 1.2 Kg/Sqm over primer . (c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 150 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP modified polymeric membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Applying two coat of bituminious based Aluminium Paint @ 0.3 Kg /Sqm over APP Membrane.
M & L for application of water proofing treatment using APP modified roof membrane over accessible/ approachable RCC roof slab( horizontal /vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying approved bituminous based primer( conforming to IS: 3384-1995) @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface & hot blown grade bitumen 85/25 softning point 115 degree C @ 1.2 Kg/Sqm over primer . (c) Laying not less than 3mm thick APP (Atactic polypropylene Polymer modified prefabricated membrane) modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gms/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 150 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP modified polymeric membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.
M & L for machine pressed cement concrete tiles 25cmX25cm X 22mm thick/ 30 cm x 30 cm x 22 mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigment ,laid over and including 15mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittins,heads,shoes,bends,swan-necks,etc including removing from site complete all as specified and directed.
S & F for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
S & F for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
S&F PVC (SWR) bends 110 mm bore of any radius complete all as specified & directed.
S&F PVC (SWR) bends 75 mm bore of any radius complete all as specified & directed.
S&F PVC (SWR) junction single (single-T) equal or unequal 110mm bore provided with access door complete all as specified & directed.
S&F PVC (SWR) junction single (single-T) equal or unequal 75mm bore provided with access door complete all as specified & directed.
S&F 110 mm bore PVC (SWR) vent cowl complete all as specified & directed..
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement with chromium plated grating with or without hole including taking down existing trap complete all as specified and directed.
S & F 110 mm dia PVC(SWR) WC connector with lip ring, complete all as directed and as specified.
M/S CHAUHAN CONSTRUCTION
M/S PARAS NATH SINGH
simplex infra project
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .