Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.7 L+₹509.77 (0.04%)Rejected-AOC LID AND EW SECTION PALLIKKATHODU GRAMA PANCHAYATH | KOTTAYAM | KERALA | 686102 | L2 | Rejected-AOC L2 | |
| 3 | L3₹13.1 L+₹35,052.45 (2.76%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹13.7 L+₹1.0 L (8.21%)Rejected-AOC | L4 | Rejected-AOC L4 |
| Sl No | Description | Qty | Unit | Shajimon Joseph L2 | Roopesh M R L3 | Mohammed Nasim K N L4 | RONY GEORGE L1 |
|---|---|---|---|---|---|---|---|
| 1.00Truss work Roofing - D/Civil Trade Auto Cad Lab in Govt. ITI Ettumanoor | |||||||
| 1.00 | 12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | 436 | sqm | 700 ₹3,05,200 Lowest | 715 ₹3,11,740 | 850 ₹3,70,600 | 850 ₹3,70,600 |
| 1.00 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 2,180.74 | kg | 175 ₹3,81,628.8 Lowest | 196 ₹4,27,424.26 | 200 ₹4,36,147.2 | 180 ₹3,92,532.48 |
| 1.00 | 4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 10.51 | cum | 10,000 ₹1,05,120 | 10,000 ₹1,05,120 | 10,950 ₹1,15,106.4 | 9,000 ₹94,608 Lowest |
| 1.00 | 5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts | 5.76 | sqm | 900 ₹5,184 | 860 ₹4,953.6 | 900 ₹5,184 | 800 ₹4,608 Lowest |
| 1.00 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 1,364 | kg | 175 ₹2,38,700 | 159 ₹2,16,876 | 170 ₹2,31,880 | 150 ₹2,04,600 Lowest |
| 1.01 | 10.19:Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. | 32 | kg | 110 ₹3,520 | 110 ₹3,520 | 100 ₹3,200 Lowest | 110 ₹3,520 |
| 1.01 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | 264.37 | sqm | 200 ₹52,873.6 | 240 ₹63,448.32 | 190 ₹50,229.92 | 130 ₹34,367.84 Lowest |
| 1.01 | 12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm) | 36 | metre | 500 ₹18,000 | 480 ₹17,280 | 425 ₹15,300 Lowest | 450 ₹16,200 |
| 1.01 | OD315700/2025-2026:Providing and fixing PVC Pathy, fittings including fixing the pathy with clamps at 1.00 m spacing. This includes jointing of pathy with one step PVC Solvent cement complete as per direction of Engineer- Charge. At lower end of roofing for collecting rain water and carried to pipe, including cutting chases and making good etc. 110 mm pathy available in Market | 32 | metre | 211 ₹6,752 | 180 ₹5,760 Lowest | 200 ₹6,400 | 200 ₹6,400 |
Tender Value
₹15.3 L
EMD Value
₹38,127
Closing Date
4 Mar 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
the Executive engineer PWD Buildings division Kott
Office of the Executive engineer PWD Buildings division Kottayam
GENERAL-Roofing works and setting up of platform in D/Civil Trade Auto Cad Lab in Govt. ITI Ettumanoor-D/Civil Trade Auto Cad Lab in Govt. ITI Ettumanoor
2026_PWD_840286_1
PWD/BLDG/TR/9884/2022_5_1_1/1
Open Tender
Civil Works - Buildings
Item Wise
120 days
kottayam
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
Yes
₹38,127
Yes
26 Mar 2026
25 Feb 2026
6 Mar 2026
25 Feb 2026
4 Mar 2026
25 Feb 2026
Truss work Roofing - D/Civil Trade Auto Cad Lab in Govt. ITI Ettumanoor
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
4.2.3:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
10.19:Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screwscomplete :Ridges plain (500-600 mm)
OD315700/2025-2026:Providing and fixing PVC Pathy, fittings including fixing the pathy with clamps at 1.00 m spacing. This includes jointing of pathy with one step PVC Solvent cement complete as per direction of Engineer- Charge. At lower end of roofing for collecting rain water and carried to pipe, including cutting chases and making good etc. 110 mm pathy available in Market
OD62504/2025-2026:Engaging man mazdoor for cleaning
Platform and other civil works for Classroom
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD172552/2024-2025:Providing and fixing 18 mm marine plywood or equivalent make paneling 12 mm thick, to frame, backing or studding with screws etc. complete ( Frames, backing or studding to be paid separately) as per the direction of site Engineer-in-charge.
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10.19:Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.98.1:Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
13.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
22.6:Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
sbd.pdf
Tender Documents • 1.63 MB
BOQ_1416494.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .