Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹3,308
Closing Date
29 Aug 2026, 2:05 pm6d left
ASSISTANT ENGINEER, SSESD PWD
57/2 DH ROAD, KOLKATA-700023
Repairing and renovation of electrical installations of Hall Room and Server Room at NIC, 3rd Floor, 3 ,Commissariat Road , Hastings, Kolkata - 700022.
2026_WBPWD_5019068_1
WBPWD/AE/SSESD/e-NIT 02 OF 2026-27
Open Tender
ELECTRICAL WORKS ORG
Percentage
Kolakta
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,308
O/O AE SSESD PWD
18 Aug 2026
18 Aug 2026
31 Aug 2026
18 Aug 2026
29 Aug 2026
20 Aug 2026
19 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. | |||||
| 1.01 | Group B (DSR (E&M) 2025 ,Page -2/1.8.2) | 35 | Points | - | - |
| 2Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. | |||||
| 2.01 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (DSR (E&M) 2025 ,Page -3/1.14.1) | 100 | Mtrs | - | - |
| 2.02 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (DSR (E&M) 2025 ,Page -3/1.14.2) | 100 | Mtrs | - | - |
| 3Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt (Make: Signify / LT / Wipro or as approved by EIC) | |||||
| 3.01 | Twin fittings along with S/F of 2 no. 18-22 Watt LED lamps as per specification | 35 | set | - | - |
| 4 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. [DSR-(E&M) 2025 , Page -9,1.42] | 35 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
BOQ_5090780.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].