Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L1 | Accepted-AOC Accepted being lowest quoted. | |
| 2 | L2₹17.0 L+₹3.5 L (25.8%)Rejected-AOC | L2 | Rejected-AOC Not accepted since higher rated quoted | |
| 3 | L3₹17.2 L+₹3.7 L (27.2%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L3 | Rejected-AOC Not accepted since higher rated quoted | |
| 4 | L4₹17.5 L+₹4.0 L (29.2%)Rejected-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-AOC Not accepted since higher rated quoted | |
| 5 | L5₹17.6 L+₹4.1 L (30.5%)Rejected-AOC | L5 | Rejected-AOC Not accepted since higher rated quoted |
Tender Value
₹16.9 L
EMD Value
₹33,800
Closing Date
8 Jun 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR MAINTENANCE REPLACEMENT OF ELECTRIC WIRING WITH FITTINGS AND FIXTURES SUB MAIN WIRING DBS WITH EARTHING IN OTM ACCN AT MIL STN GANDHINAGAR
2020_MES_344104_1
GE(A)/GNR/TOKEN/09 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹33,800
Yes
8 Sept 2020
12 May 2020
10 Jun 2020
12 May 2020
8 Jun 2020
26 May 2020
12 May 2020 - 25 May 2020
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One light point controlled by two, 2- way switches.
(c) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
(d) One multi pin 5 Amps, socket outlet on Independent board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F, in repair, lamp holder, PVC/Polycarbonate, with back plate suitable for batten fittings complete all as specified and directed
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed as per make of Anchor/Vinay /Havells..
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, switch flush type 5 Amps, single pole, two ways complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, socket outlet, 2 in 1, 3 pin, 15 Amps and 5 Amps flush type complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, socket outlet, 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, in repair, MCB single pole, 6 to 32 Amp 240 volts with 'B' curve, fixed in sheet metal board including connecting complete all as specified and directed. Makes of Havells/Legrand/Schneider.
S&F, in repair, MCB single pole and neutral, 40 Amps, 240 volts with 'B' curve, fixed in sheet metal board including connecting complete all as specified and directed. Makes of Havells/Legrand/Schneider.
S&F, in repair, MCCB, triple pole and neutral, 25 KA, 63 Amps, 415 Volts including connecting complete all as specified and directed. Makes of Havells/Legrand/Schneider.
S&F, in repairs, sheet metal distribution board, SPN, 12 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, in repairs, sheet metal distribution board, SPN, 8 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, in replacement, ceiling fan regulators, Electronic type, AC, 230 Volts complete all as specified and directed.
S&F, in repair, LED light fitting, batten type, housed in extruded from powder coated aluminium, 20 watt connecting with flexible three core copper conductor cable of suitable size and testing complete all as specified and directed as per Make of Wipro/Havells/Bajaj.
S&F, in repair, LED light fitting, batten type, 10 watt connecting with flexible three core copper conductor cable of suitable size and testing complete all as specified and directed as per Make of Wipro/Havells/Bajaj.
S&F, in repair, LED bulk head, 10 watt connecting with flexible three core copper conductor cable of suitable size and testing complete all as specified and directed as per Make of Havells/Bajaj/Crompton.
S&F, in repair, LED fittings, ceiling mounted recessed 2 x 2 luminaire 36 watt and glare free soft illumination complete all as specified and directed as per Make of Wipro/Havells/Bajaj.
S&F, in repair, LED Post top lantern made of cast aluminium with decorative opal poly carbonate diffuser with protection IP-65 with 40 W LED (Warm white) complete with electrical connections. Make : Bajaj/Havells/Wipro
S&F, in repair, LED type, building security light fittings, IP-66 protection, 25W, Pressure die cast aluminium housing with toughned glass & individual LED's with secondary optics including taking out old unsv fitting of any type complete all as specified and directed as per Make of Havells/Bajaj/Eveready.
S & F, in repair, Distribution Board Power line VTPN, 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, including 4 pole MCCB 63 Amps rating for incoming supply and including 12 Nos single pole MCBs 6 Amp to 32 Amp for outgoing supply complete all as specified and directed as per make of Havells/Legrand/Schneider.
S&F, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC conduit of 32mm size including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 2.5 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: (i) 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length. (ii) Rates quoted shall be inclusive of cutting wall for concelling conduit and making good the same in cement mortal 1:3.
TRIMURTHI ENTERPRISES
Electricals India
Badri Electricals
Singh Engineer And Contractor
Ramdev and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .