Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹19.0 L+₹1.7 L (9.62%)Rejected-Finance 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹21.4 L+₹4.0 L (23.4%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹22.3 L+₹5.0 L (28.9%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹24.4 L+₹7.1 L (40.8%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
2 Dec 2021, 6:00 pmClosed
GE (AF) Phalodi
GE (AF) Phalodi
REPAIR / MAINT OF LT CABLE, PANEL BOARD AND CONNECTED ITEMS AT AF STN PHALODI.
2021_MES_486479_1
8372/A/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Phalodi
Class D Cat b(i)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹60,000
Yes
4 Jan 2022
5 Nov 2021
4 Dec 2021
5 Nov 2021
2 Dec 2021
19 Nov 2021
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for laying underground cable in soft/losse soil complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for laying underground cable in hard and dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supplying and laying reinforced precast concrete cable cover, class EHV, with peak, Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
Disconnecting and Taking out of old LT armored PVC cables from trenches of any size/core/any voltage grade from trenches for replacement all as directed.
M & L for XLPE screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)with stranded aluminum conductor, 1100 volts grade, earth type cross sectional area 16 Sqmm 4 core LT UG cable laid in trenches/through pipe/fixed along pole or in duct with necessary angle iron support,clamp,nut bolts etc. complete all as specified and directed.
All as per item No. 8 above but size of cable 25 sqmm 3.5 core
All as per item No. 8 above but size of cable 35 sqmm 3.5 core
All as per item No. 8 above but size of cable 50 sqmm 3.5 core
All as per item No. 8 above but size of cable 95 sqmm 3.5 core
All as per item No. 8 above but size of cable 120 sqmm 3.5 core
All as per item No. 8 above but size of cable 150 sqmm 3.5 core
All as per item No. 8 above but size of cable 185 sqmm 3.5 core
Supply and replace aluminium cable lug in repair of size of cable lug 25 sqmm complete all as specified and directed.
All as per item No. 16 but size of cable lug 35 sqmm
All as per item No. 16 but size of cable lug 50 sqmm
All as per item No. 16 but size of cable lug 70 sqmm
All as per item No. 16 but size of cable lug 95 sqmm
All as per item No. 16 but size of cable lug 120 sqmm
All as per item No. 16 but size of cable lug 150 sqmm
All as per item No. 16 but size of cable lug 185 sqmm
All as per item No. 16 but size of cable lug 240 sqmm
All as per item No. 16 but size of cable lug 300 sqmm
Supply and replace aluminium crimping connectors in repair of size of crimping connectors 25 sqmm complete all as specified and directed.
All as per item No. 26 but size of crimping connectors 35 sqmm
All as per item No. 26 but size of crimping connectors 50 sqmm
All as per item No. 26 but size of crimping connectors 70 sqmm
All as per item No. 26 but size of crimping connectors 95 sqmm
All as per item No. 26 but size of crimping connectors 120 sqmm
All as per item No. 26 but size of crimping connectors 150 sqmm
All as per item No. 26 but size of crimping connectors 185 sqmm
All as per item No. 26 but size of crimping connectors 240 sqmm
All as per item No. 26 but size of crimping connectors 300 sqmm
Cutting of road / hardstanding upto a size not exceeding 20 cms in width and not exceeding 60 cms in depth for laying of LT UG cable protection piep line making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type C1 complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in repair of LT panel foundation complete all as specified and directed.
M&L for making of surface for painting duly scrubing the existing paint and apply of two coats of existing synthetic enamel paint over a coat of red oxide primer for LT panel board/Feeder piller box of any size/type at various location complete all as specified and directed.
M&L for repairs to Outdoor/Indoor type LT panel Board of any capacity/size by repalcing pitted portion not excedding 1.0 sqm with suitable gauge of MS sheet,welding work,replacement of unservicable door Hinges and locking arrangement complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB three pole 63 Amps, 16 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB three pole 125 Amps, 16 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 63 Amps, 16 KA rating,Ics=75% Icu ,415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 125 Amps, 16 KA rating,Ics=75% Icu ,415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 160 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 200 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 250 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 400 Amps, 36 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 500 Amps, 50 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair Adjustable thrmal & Adjuatable magnetic setting MCCB Four pole 630 Amps, 50 KA rating, 415 volts AC complete all as specified and directed.
S & F in repair MCB Four pole 100 Amps, 415 volts AC complete all as specified and directed.
S & F in repair LT Cable jointing kit for straight through and heat shrink type joint complete with jointing material and accessories suitable for 70 to 150 sqmm XLPE armoured aluminium conductor cable including cutting and removing existing unserviceable joint, excavation near 2/4 pole structure / HT Panel board / Transformer and taking out loop cable from trench and refilling the trench with excavated material acomplete all as specified and directed.
S & F in repair LT Cable jointing kit for straight through and heat shrink type joint complete with jointing material and accessories suitable for 185 to 300 sqmm XLPE armoured aluminium conductor cable including cutting and removing existing unserviceable joint, excavation near 2/4 pole structure / HT Panel board / Transformer and taking out loop cable from trench and refilling the trench with excavated material complete all as specified and directed.
S & F in repair of volt meter 0 --500 volt digital type square 96 sq mm AE/ENERCON lamp accurracy glass complete all as specified and directed.
S & F in repair of Ammeter 0 --200 Amp digital type square 96 sq mm AE /ENERCON lamp accurracy glass complete all as specified and directed.
S & F in repair LED batton fitting 1 x20 Watt, 220 V decorative box type with driver 4" complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed.
S & F in repair C T coil suitable for Amp meter 100 /5 Amp complete all as specified and directed.
S & F in repair indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing all as specified and directed.
Mahaveer Traders
M/S SOLANKI GENERAL SUPPLIERS
L C ASSOCIATES
SANJOLI CONSTRUCTION COMPANY
Beenu Co. Company
Shri Electrical Enterprises
M/S HARIOM CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .