Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.3 L+₹5,796 (0.63%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹9.5 L+₹27,366 (2.96%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹9.6 L+₹35,054 (3.80%)Rejected-Finance 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L4 | Rejected-Finance Not being L1 |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
15 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) Navy Jamnagar
INS Valsura Jamnagar - 361150
Addition/ alteration and Improvement to Squash Court (Bldg P-58) at INS Valsura, Jamnagar
2023_MES_595352_1
8661/VAL/E8
Open Tender
Civil Works
Item Rate
90 days
GE (I) Navy Jamnagar
Please refer tender document
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹19,400
Yes
11 Jul 2023
13 May 2023
17 Jun 2023
13 May 2023
15 Jun 2023
29 May 2023
13 May 2023 - 20 May 2023
Amount
M&L for flooring with factory made Klin Seasoned Maple wood surface board finished with 20mm thick, 50 to 85mm width and in random length in tongue and groove shape, the edges of the boards will have a finger lock groove and the bottom side with air pass groove confirming WSF guidelines, including new maple wood battens & polishing to matching with existing floor including fixing finishing the surface all as per manufacturer's instructions and to the entire satisfaction of Engineer-in-Charge including dismantling of damaged / unserviceable any type of squash court wooden flooring complete all as specified & as directed. Make: Asian Flooring India Pvt Ltd, M/s Go Sportz Global Infratech Pvt Ltd, M/s HARO Sports or equivalent as approved by GE. Note : Net plan floor area shall be measured for payment purpose and quoted rate shall deemed to be inclusive of this aspect.
M&L for preparation of old unpolished surface of Squash Court floor including rubbing and cleaning and applying two coats of polish as per specification and WSF guidelines complete all as specified and as directed.
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
M&L for 12mm thick Hard Plaster for Squash Court with high impact resistance, flat & true predictable rebound surfaces complying to the requirement of WSF (Approved by World Squash Federation) applied as per manufacturer's instructions complete all as directed.
S&F 600mmx600mm grid type false ceiling with white powder coated GI sheets 0.4 mm thick includig fasteners, suspenders etc fixed as per manufacturer's instructions and best trade practice with & including disconnecting & taking down carefully existing serviceable wiring/light fittings/fixtures etc and finally re-fixing the same to its original position or different locations including testing on completion as ordered complete all as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished fair and even complete all as specified and as directed.
M&L for plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified & as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of Matt finish emulsion paint over a coat of primer over play area complete all as specified & as directed.
M&L for preparation of old or undecorated plastered surfaces of walls and applying two coats of Matt finish emulsion paint over a coat of primer over play area complete all as specified & as directed.
S&F 2mm thick Sound Board (Tin) of 480mm Standard height and 6400mm length fixed in not more than two parts (3200mm each) to tin of Squash court fixed as per international squash court norms to the entire satisfaction of Engineer-in-Charge.
M&L for post construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litres per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same to match with the existing finish complete all as specified and as directed.
M&L for tape/game line marking in flooring and wall of squash court with approved quality material as used for marking international standard squash court complete all as directed.
M&L for 12mm thick toughned Glass in Back Wall system of Squash Court consisting of panels of size as ordered including one door of size exc 1.5 Sqm but not exc 3 Sqm made out of 12mm thick toughned glass fixed in between panels with all fittings/hardware/locking arrangement as required complete all as directed.
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer complete all as specified & as directed.
Dismantling of Plain or corrugated sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls, fixed with self tapping screws complete all as specified & as directed. Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc
M&L for two coats of 1st quality synthetic enemal paint of approved tint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surfaces complete all as directed.
S&F Mild steel framed bracket of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary, gusset plates, rivering etc. conforming to Fe.290 (Gde E-165), complete all as specified & as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F stainless steel (Grade-304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dah fasteners, stainless steel bolts etc, of required size for gate with suitable arrangement as per approval of Engineer-in-Charge. (for payment purpose only weight of stainless steel members shall be considered exclusing accessories such as nuts, bolts, faterners etc).
M&L for welded steel wire fabric weight not exceeding 4 Kg per sqm cut to size made to shape as ordered & fixed to wood or steel members complete all as specified and as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutter/ louvered ventilator, fixed/ sliding type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws etc. complete all as specified and as directed. Note: Glass shall be measured and paid for seperately.
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sheet metal box, terminal plates with all accessories, concealed MS box/ PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
Taking down existing light fitting of any type & fixed in any position and S&F new 22/24 W ultra slim recess/surface mounted LED light fitting suitable for mounting with Armstrong/ Grid ceiling, white powder coated Aluminium housing and full mounted acrylic diffuser, the CCT should be 6500K, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
Taking down flood light fittings of any type and wattage and depositing the same to AGE E/M Store Yard complete all as directed.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed. Make: Legrand Cat No. 4085 87 to 4085 95 or equivalent in makes mentioned in Appendix 'B' here-in-after.
M/s. Jayant G Rampariya
KRISHNA ENGINEERING
1R K Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .