Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.3 L+₹1.9 L (25.1%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance NOT BEING L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
24 Jun 2024, 6:00 pmClosed
AGE I R AND D KOCHI
AGE I R AND D KOCHI, THRIKKAKARA,KAKKANAD, KOCHI 682021
REPAIR MAINTENANCE OF HT LT UG CABLE ALONG WITH CONNECTED WORKS AT TECHNICAL AREA OF NPOL KOCHI
2024_MES_655489_1
8284E8AGERDK
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
kakkanad
As per tender doucuments
6 documents required · 6 mandatory
₹500
Yes
AGE I R AND D KOCHI
₹19,000
Yes
25 Apr 2025
22 May 2024
26 Jun 2024
22 May 2024
24 Jun 2024
5 Jun 2024
Amount
M & L for XLPE insulated, screened , PVC bedded, galvanise steel strip or wire armoured, electric power cables (Heavy duty) with aluminium conductor, 11000 Volts (Earthed) grade cross sectional area 120 Sqmm 3 core in trenches/fixed on wall with supporting insulator/saddles etc all as specified and directed.
M & L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 Volts grade, in trenches/fixed on wall with supporting insulators/saddles etc for following size complete.
95 sqmm 3.5 core
70 Sq mm 3.5 Core
50 Sq mm 3.5 Core
35 Sqmm 3.5 Core
25 Sq mm 3.5 Core
10 Sq mm 4 Core
Material and labour for heat shrinkable HT, 11 KV , outdoor type, cable end joint 120-185 sq mm 3 core suitable for 11 KV, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed,
Material and labour for heat shrinkable HT, 11 KV , indoor type, cable end joint 120-185 sq mm 3 core suitable for 11 KV, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed.
Material and labour for heat shrinkable LT, 1100 volt grade, outdoor type, cable end joint suitable for 1100 Volt grade, 3 Phase, AC, 50 Hz, , XLPE Cable including jointing materials complete including taking down old end joints all as specified and as directed for following size.
50-120 sq mm 3.5 core
150-240 Sq.mm 3.5 core
300-400 Sq.mm 3.5 core
Supply and lay in trenches/fixed on wall GI tubing light grade with necessary fittings such as bend, tee, elbow etc complete for the following sizes for protection of LT UG cable.
80 mm bore
50 mm bore
Excavation in trenches not exceeding 1.5 mtr deep and 1.5 mtr width as in Hard dense soil soil complete all as specified. Note: NO JCB Excavation is permitted for earth work.
Returning filling incl leveling watering and well ramming in layer not exceeding 25 cm thick complete all as specified
Removal of surface soil to a distance n.exc 50 m and deposited where directed at a level n. exc 1.5 m above the starting point complete
S & L for riddled earth /sand for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable complete ( Note: Punned thickness shall be taken for measurement)
M & L for laying un-reinforced precast concrete cable cover, class HVP, type -1 with size 300 mm x 180 mm x 40 mm all as directed by Engr-in-Charge.
M & L for laying LV unreinforced precast concrete cable cover but Type 2, flat, size 300mm x 180mm x 40mm directed by Engineer-in-Charge.
M & L for road cutting /removing the hard Standing/Cutting floor inside the Substaion /E/M Installations / Path for laying of cables of any size complete all as specified.
M & L for PCC 1:4:8 Type D2 (40 mm graded aggregate) complete for making good to the excavated portion of Road/Hard Standing at road crossing etc complete.
Supply and fix water proof junction box made from SMC sheet readymade of size 168 X 253 X 115 mm with aluminium bus bar of 150 Amp capacity for RYB and neutral fixed inside the junction box with necessary supporting insulators fixed on hylem sheet /Insulating sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assembly fixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts, and connecting cables from junction box to fittings complete all as directed by Engineer-in-Charge.
Supply and fix MCB DB TPN 4 way IP 43 protection ,double door , concealed on wall and making good to disturbed surface so as to match with existing complete all as specified and as directed by Engineer-in -Charge. Make : Legrand /L & T /Havell's.
Supply & Fix VTPN DB withMCCB incomer ,Metal double door,415 V, three phase,6 way ready to use DBs provided with Neutral Bar, Mechanical Impact Strength IK 09 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for MCCB's upto 125Amp as I/C (Frame 1) and MCBs (TP/DP/SP) as outgoing, IP 43 protection, module Optium F2+6+6+6, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including connection of incomming & out going cables using suitable size lugs and glands complete all as specified and directed. ( Main DBs for Each floors)
Supply and fix in replacement MCB 240 V 50 Hz AC 10 KA , of following rating with necessary lugs for incomming and outgong connections fixed on DB / Enclosure /Panel Boards after taking down the existing MCB of any make/ rating : Make : Legrand / L & T /Havell's
MCB SP 6 to 32 Amp, 'C' curve.
MCB DP 32 Amp, 'C' Curve
Supply and fix MCB 40-100 Amp , 4 Pole, 10 KA, 'C' Curve complete all as specified and as directed by Engineer-in -Charge Make: Legrand /L & T /Havell's
S & F MCCB 4 pole 100-125 Amp 16 KA complete all as specified and as directed by Engineer-in -Charge Make: Legrand /L & T /Havell's
S&F in repair LED indicators (colours red/ yellow/ blue/ white/ green) complete all as specified and as directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 32x6 mm GI strip means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected or indicated including testing on completion incl necessary excavation, earth work, pcc pit, RCC cover ,funnel with watering pipe 20mm bore light grade, GI protection pipe 40 mm bore light grade complete all as specified and as directed by the Engineer - in - Charge. Note: No JCB excavation permitted inside the E/M installation
M& L for HT cable route indicator for underground cable indication
M& L for LT cable route indicator for underground cable indication
Supply and lay double wall corrugated (DWC) HDPE pipe 63mm bore, as per IS-14930 including couplers and bend for cable protection laid in trenches etc complete all as specified and as directed by Engineer-in-Charge. Make : TELEREX 450N or equivalent as approved by GE
WELTRONENGINEERINGSERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .