Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.3 Cr
EMD Value
₹2.2 L
Closing Date
11 Apr 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
14 conditions · 3 needing a document upload
10.2.Financial Eligibility Criteria:- The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
10.1 Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre- defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling
2.13.02 Similar Nature of Work means-: "Execution of any 1500 V DC or 25 KV AC OHE work"
3 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Care in Submission of Tenders: (a) (i)Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all-inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer. (a)(ii)Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt.& as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. (a)(iii)The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the Contractor. The Contractor shall be responsible for deposition of applicable GST to the concerned authority. (a)(iv)In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority. (b)When work is tendered for by a firm or company, the tender shall be signed by the individual legally authorized to enter into commitments on their behalf. (c)The Railway will not be bound by any power of attorney granted by the tenderer or by changes in the composition of the firm made subsequent to the execution of the contract. It may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the Contractor. (a)(v) Contractor shall be liable to pay/refund the amount collected as GST to the Indian Railways along with interest and penalties, if any imposed by the authorities, in case GST input tax credit of Indian Railways is denied/rejected by the tax authorities due to reasons mentioned below but not limited to: Wrong/incorrect invoices is sued by Contractor; No-filing of GST returns; Non-payment of GST collected from Indian Railways to the authorities; Any other non- compliance done by Contractor; General Indemnity: Contractor hereby agrees to indemnify and hold harmless the Indian Railways from and against any and all losses, including loss on account of Input Tax Credit and all losses incurred by the Indian Railways relating to or arising out of or in connection with any actual or threatened claim, legal action, proceedings, prosecution or inquiry by or against the Indian Railways arising out, directly or indirectly, of failure by the contractor to comply with the provisions of GST and related laws, or based upon or arising from any failure by the Contractor. Retention Money: Any payment liable to be paid by Indian Railways to contractor against the goods or services or both supplied by such contractor to Indian Railways shall be kept on hold in case supplier makes any non-compliance of any of the GST
Design, Supply, Erection & Testing of 25 KV AC OHE system and general services work in connection with "Y" connectivity between Sabarmati A to Asarva of ADI Division of Western Railway.
EL-C-ADI-TRD-GS-44R-24-25
EL-C-ADI-TRD-GS-44R-24-25
Open
Works - General
12 Months
Ahmedabad, Gujarat
₹0
₹2.2 L
11 Apr 2025
11 Mar 2025
229 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,31,49,958.5 | ||
| — | 160.00 | — | — | ||
| Concrete for foundation and plinth in all type of soil incl. hard/ rocky soil (incl. excavation and supply of all materials viz., sand, cement, and ballast etc.) | — | — | — | 9,51,680 | |
| — | 2.00 | — | — | ||
| Reinforced Concrete for foundation and cable trench | — | — | — | 17,896 | |
| — | 24.00 | — | — | ||
| Supply of rolled or fabricated and galvanized traction mast, TTC, Portal with boom and AT masts, Feeder mast etc. | — | — | — | 26,01,960 | |
| — | 8.00 | — | — | ||
| Supply of fabricated and galvanized steel works other than traction mast, TTC, portals etc. (SPS) | — | — | — | 8,72,280 | |
| — | 60.00 | — | — | ||
| Supply of single cantilever assembly complete with insulator for OHE and inside the tunnel | — | — | — | 12,37,620 | |
| — | 30.00 | — | — | ||
| Supply of pull-off arrangement for OHE | — | — | — | 3,17,700 | |
| — | 20.00 | — | — | ||
| Supply of guy rod assembly | — | — | — | 1,70,140 | |
| — | 10.00 | — | — | ||
| Supply of regulating equipment 3 pulley type complete with all accessories including counter weight assembly and SS wire rope for OHE. | — | — | — | 5,46,900 | |
| — | 100.00 | — | — | ||
| Supply of all types of GI bonds (40 X 6 mm) | — | — | — | 1,05,800 | |
| — | 10.00 | — | — | ||
| Supply of Earth electrode- 3 Mtr | — | — | — | 41,750 | |
| — | 4.00 | — | — | ||
| Supply of 25KV single pole, 1600A isolator | — | — | — | 3,16,824 | |
| — | 30.00 | — | — | ||
| Supply of materials for termination of double conductor (including supply of 9 t cut-in insulator) of overhead equipment. | — | — | — | 3,39,090 | |
| — | 20.00 | — | — | ||
| Supply of materials for termination of single conductor with 9 t cut-in insulator | — | — | — | 1,34,360 | |
| — | 8.00 | — | — | ||
| Supply of section insulator assembly including core and cut-in insulator | — | — | — | 4,04,640 | |
| — | 8.00 | — | — | ||
| Supply of 25KV solid core cut-in insulator | — | — | — | 66,040 | |
| — | 8.00 | — | — | ||
| Supply of 25KV solid core suspension insulator | — | — | — | 69,808 | |
| — | 8.00 | — | — | ||
| Supply of 25KV post insulator | — | — | — | 65,920 | |
| — | 2.00 | — | — | ||
| Supply of overhead equipment excluding catenary & contact wire. Scope includes supply of number plates & various types of caution & other boards including shock treatment chart etc. | — | — | — | 6,13,726 | |
| — | 10.00 | — | — | ||
| Supply, installation , Testing & commossioning of Catenary wire splice Over & above as required for item D1 | — | — | — | 4,500 | |
| — | 10.00 | — | — | ||
| Supply, installation , Testing & commossioning of Contact wire splice over & above as required for item D1 | — | — | — | 11,560 | |
| — | 2.00 | — | — | ||
| Preparation all drawing and design for overhead equipment including LOP, SED, CSD, Bonding Plan etc. | — | — | — | 30,764 | |
| — | 24.00 | — | — | ||
| Erection of rolled or fabricated and galvanized traction mast and auxiliary transformer masts, TTC and portals | — | — | — | 1,62,864 | |
| — | 8.00 | — | — | ||
| Erection of fabricated and galvanized steel works other than traction mast (SPS) | — | — | — | 53,352 | |
| — | 60.00 | — | — | ||
| Erection of single cantilever assembly complete with insulator for OHE and inside the tunnel | — | — | — | 97,560 | |
| — | 30.00 | — | — | ||
| Erection of pull-off arrangement for OHE | — | — | — | 37,110 | |
| — | 20.00 | — | — | ||
| Erection of guy rod assembly | — | — | — | 29,800 | |
| — | 10.00 | — | — | ||
| Erection of regulating equipment 3 pulley type complete with all accessories and adjustment of the same | — | — | — | 60,650 | |
| — | 100.00 | — | — | ||
| Erection of all types of GI bonds | — | — | — | 26,600 | |
| — | 10.00 | — | — | ||
| Erection of Earth electrode- 3mtr | — | — | — | 15,130 | |
| — | 4.00 | — | — | ||
| Erection of 25KV single pole isolator without earth contact assembly | — | — | — | 18,272 | |
| — | 30.00 | — | — | ||
| Erection of materials for termination of Single/double conductor (including supply of cut-in insulator) of overhead equipment. | — | — | — | 43,050 | |
| — | 20.00 | — | — | ||
| Erection of anti-creep with 9T insulator over & above as incl. in E34 | — | — | — | 77,720 | |
| — | 8.00 | — | — | ||
| Erection of section insulator assembly including core and cut-in insulator | — | — | — | 47,576 | |
| — | 8.00 | — | — | ||
| Erection 25KV solid core cut-in insulator | — | — | — | 7,264 | |
| — | 8.00 | — | — | ||
| Erection of 25KV solid core suspension insulator | — | — | — | 8,504 | |
| — | 8.00 | — | — | ||
| Erection of 25KV Post/Support insulator | — | — | — | 6,792 | |
| — | 2.00 | — | — | ||
| Erection of overhead equipment, including catenary, false catenary, contact, jumper and dropper wires, fixing of number plates & various type of boards | — | — | — | 1,28,216 | |
| — | 100.00 | — | — | ||
| Erection of 150 sqmm copper feeder wire. | — | — | — | 3,300 | |
| — | 100.00 | — | — | ||
| Transfer of OHE from one support to another and adjustment of droppers | — | — | — | 4,76,300 | |
| — | 0.50 | — | — | ||
| Dismantling & removal of OHE complete with cantelever, droppers, contact & catenary wire etc. | — | — | — | 18,436.5 | |
| — | 4.00 | — | — | ||
| Dismantling & removal of Isolator complete | — | — | — | 13,740 | |
| — | 4.00 | — | — | ||
| Dismantling & removal of Mast, portal, TTC & other small part steel | — | — | — | 27,748 | |
| — | 40.00 | — | — | ||
| Breaking of concrete foundation of Masts, portals & TTC | — | — | — | 1,06,160 | |
| — | 20.00 | — | — | ||
| Dismantling & removal of Guy rod assembly | — | — | — | 25,540 | |
| — | 12.00 | — | — | ||
| Transportation of Railway supply materials from Railways depots to work site OR Transportation of Released material from work site to Railway depot. | — | — | — | 60,240 | |
| — | 1.00 | — | — | ||
| Work under Power Block:Any erection work as per schedule done under power and /or Traffic block is subject to have extra rate @ 30%. | — | — | — | 4,47,505 | |
| — | 1.00 | — | — | ||
| Pull lift machine 3 tonne pulling capacity and 3 tonne lifting capacity Make Tracel Tirfer India Pvt Ltd or similar | — | — | — | 28,011 | |
| — | 1.00 | — | — | ||
| Pull lift machine 5.2 tonne pulling capacity and 3.2 tonne lifting capacity Make Tracel Tirfer India Pvt Ltd or similar | — | — | — | 27,781 | |
| — | 1.00 | — | — | ||
| Pull lift machine 1.5 tonne pulling capacity and 2 tonne lifting capacity Make Tracel Tirfer India Pvt Ltd or similar | — | — | — | 17,127 | |
| — | 1.00 | — | — | ||
| Earthing discharge rod complete. | — | — | — | 11,503 | |
| — | 1.00 | — | — | ||
| Aluminium straight ladder (9.3 m) with hook on top. | — | — | — | 15,924 | |
| — | 1.00 | — | — | ||
| Aluminium folding ladder (11 m) with hook on top. | — | — | — | 47,709 | |
| — | 1.00 | — | — | ||
| Portable electric drill machine21mm, single phase 230 Volt ( for drilling rails for bonding). | — | — | — | 7,792 | |
| — | 1.00 | — | — | ||
| Contact wire cutter 36". | — | — | — | 6,042 | |
| — | 1.00 | — | — | ||
| Dropper wire cutter 12". | — | — | — | 5,275 | |
| — | 1.00 | — | — | ||
| Single sleeve pully block 3 1/2" x 1/2" groove steel. | — | — | — | 8,272 | |
| — | 1.00 | — | — | ||
| Contact wire twist cum bender 6" | — | — | — | 1,993 | |
| — | 1.00 | — | — | ||
| Steel sling 1m long, eye at each end 19 mm dia. | — | — | — | 996 | |
| — | 1.00 | — | — | ||
| Steel sling 2m long, eye at each end 19 mm dia. | — | — | — | 1,177 | |
| — | 1.00 | — | — | ||
| Steel sling 3m long, eye at each end 19 mm dia. | — | — | — | 1,384 | |
| — | 1.00 | — | — | ||
| Steel sling 4m long, eye at each end 19 mm dia. | — | — | — | 1,738 | |
| — | 1.00 | — | — | ||
| Steel sling 5m long, eye at each end 19 mm dia. | — | — | — | 5,145 | |
| — | 1.00 | — | — | ||
| Fabric metric tape 30 mtr long 15 mm wide each. | — | — | — | 927 | |
| — | 1.00 | — | — | ||
| Engineering ratchet with socket set | — | — | — | 5,393 | |
| — | 1.00 | — | — | ||
| Digital Earth tester (0-20/200/2000) with complete accessories, Make - MOTWANE or equivalant | — | — | — | 7,757 | |
| — | 1.00 | — | — | ||
| Screw driver set consisting of 6", 8", !2", 16" & 18" | — | — | — | 1,879 | |
| — | 1.00 | — | — | ||
| Insulated cutting plier (12") & (8") | — | — | — | 648 | |
| — | 1.00 | — | — | ||
| Sprit level (12") & (6") | — | — | — | 7,301 | |
| — | 1.00 | — | — | ||
| Tensometer IDT-10 Ton capacity. | — | — | — | 23,973 | |
| — | 1.00 | — | — | ||
| Hydraulic crimping tool. | — | — | — | 20,379 | |
| — | 1.00 | — | — | ||
| Bench grinder (Double end pedeswtal) Motor driven. | — | — | — | 42,666 | |
| — | 1.00 | — | — | ||
| 50W LED flood light IP65 rating | — | — | — | 2,183 | |
| — | 1.00 | — | — | ||
| Syren covering distance one kilometer (Electric). | — | — | — | 9,104 | |
| — | 1.00 | — | — | ||
| High Beam (Range 1 km) rechargeable 15W LED torch | — | — | — | 4,376 | |
| — | 1.00 | — | — | ||
| D' Spanner double ended 24 sizes in a set of 12 pieces Gedore make or equivalent | — | — | — | 2,217 | |
| — | 1.00 | — | — | ||
| Ring spanner double ended 24 sizes in a set of 12 pieces Gedore make or any other substantially equipment make. | — | — | — | 5,086 | |
| — | 60.00 | — | — | ||
| Providing temporary lighting & accomodation arrangment during night working and TWO by portable type 2 to 5 KVA DG Set on hiring basis comlete with fuel,oil, acessories and all material. | — | — | — | 5,75,520 | |
| — | 2.00 | — | — | ||
| Preparation documents, SWR, App G, Display Notice boards, key box , paper for EIG & CRS. | — | — | — | 10,926 | |
| — | 25.00 | — | — | ||
| Tree Trimming for OHE section | — | — | — | 10,925 | |
| — | 1.00 | — | — | ||
| Supply, transportation, installation, testing & commissioning of lighting MDB consisting Incoming 1x125A MCCB and outgoing 2x63A, 4-pole MCB , 2 x40 A DP MCB & 10 x 16 A DP MCB. | — | — | — | 25,869 | |
| — | 1.00 | — | — | ||
| Supply installation, Testing & commissioning of 250A feeder pillar. | — | — | — | 16,660 | |
| — | 2.00 | — | — | ||
| Supply, transportation, installation, testing & Commissioning of SDB Switch board consisting- Incoming 2 x 63 A 4-pole MCB & Out going -10 x 16-20 A DP MCB . | — | — | — | 14,282 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing & commissioning of Distribution board having incoming-32 A DP MCB and outgoing- 6 x16A SP MCB. | — | — | — | 1,871 | |
| — | 650.00 | — | — | ||
| Digging of cable trench 450 x 1000 mm & refilling as per Specification. | — | — | — | 46,150 | |
| — | 130.00 | — | — | ||
| Digging of cable trench 450 x 1000 mm in RCC/PCC/hard soil. | — | — | — | 46,280 | |
| — | 1300.00 | — | — | ||
| Transportation, Laying,Installation , terminating, testing and commissioning of HT/LT cable of sizes 4x10 sqmm to 4x 300 sqmm in existing trench, pipe or on structure. | — | — | — | 33,800 | |
| — | 13.00 | — | — | ||
| Supply, installation, testing & Commissioning of LT /HTcable route marker. | — | — | — | 1,963 | |
| — | 650.00 | — | — | ||
| Supply and laying of RCC half round pipe 100 mm ID & 1 mtr length. | — | — | — | 32,500 | |
| — | 60.00 | — | — | ||
| Supply,installation, testing & commissioning of HDPE Pipe 110 mm Nominal Dia as per IS -4984-1995. | — | — | — | 28,980 | |
| — | 60.00 | — | — | ||
| Laying of HDPE/GI pipe by Push through Method under track/Road. | — | — | — | 25,560 | |
| — | 22.00 | — | — | ||
| Supply,installation, testing & commissioning of 5mtr long hot dip galvanised octagonal poles with 130 mm bottom & 70 mm top made up of 3mm thick steel sheet along with base plate of size 200x200x12mm with foundation. | — | — | — | 2,23,960 | |
| — | 23.00 | — | — | ||
| Supply, installation, testing & commissioning of 45 system watt LEDstreet light fitting. | — | — | — | 1,32,664 | |
| — | 18.00 | — | — | ||
| Supply, installation, testing & commissioning of surface wiring of light, fan and call bell point with modular switch by 3 nos. 1.5 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC casing caping and accessories. | — | — | — | 7,308 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing & commissioning of surface wiring of plug point 6 Amps with modular switch on same board by 3 nos. 1.5 sq mm FRLS PVC insulated copper conductor multi- strand single core in PVC casing caping and accessories | — | — | — | 720 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing & commissioning of surface wiring of modular plug point 16/6 Amps with modular switch on separate board by 3 nos. 4.0 sq mm FRLS PVC insulated copper conductor multi-strand single core in PVC casing caping and accessories. | — | — | — | 930 | |
| — | 40.00 | — | — | ||
| Supply, erection, testing & commissioning of surface wiring of sub-main from board to board and room to room with 3 nos. 2.5 sq mm FRLS PVC copper conductor, multi-strand single core in PVC casing caping and accessories. | — | — | — | 2,640 | |
| — | 10.00 | — | — | ||
| Supply, erection, testing & commissioning of surface wiring of sub-main from board to board and room to room with 3 nos.4.0 sq mm FRLS PVC copper conductor, multi-strand single core in PVC casing caping and accessories. | — | — | — | 950 | |
| — | 2.00 | — | — | ||
| Supply,installation, testing and commissioning of ceiling fans including hooks, clamps, nuts & bolts etc. | — | — | — | 3,238 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing & commissioning of serface type modular electronic fan regulator. | — | — | — | 876 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing & commissioning of 10/20 W LED bulk head fitting with 230 Volt AC operated. | — | — | — | 7,806 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of concealed 100W modular fan regulator. | — | — | — | 876 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of exhaust fan complete with all accessories. | — | — | — | 1,644 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing & commissioning of 1x (18-20) W LED tube fittings . | — | — | — | 12,890 | |
| — | 6.00 | — | — | ||
| Supply,installation, testing & commissioning of Pipe earthing. | — | — | — | 15,588 | |
| — | 530.00 | — | — | ||
| Supply,installation, testing & commissioning of 8 SWG G.I. earth Wire. | — | — | — | 9,540 | |
| — | 30.00 | — | — | ||
| Supply and providing 50 mm dia UPVC Pipe. | — | — | — | 4,560 | |
| — | 28.00 | — | — | ||
| Excavation of all kind of soil (except Rock) and filling back the excavated earth as per Specification. | — | — | — | 3,640 | |
| — | 20.00 | — | — | ||
| Excavation of Hard soil (Stone/Rock/RCC) and filling back the excavated earth as per Specification. | — | — | — | 16,860 | |
| — | 10.00 | — | — | ||
| Dismantling & stacking of Rail /Tubular pole with removal of O/H lines | — | — | — | 5,910 | |
| — | 1.00 | — | — | ||
| Dismentaling of FL mast | — | — | — | 16,641 | |
| — | 1.00 | — | — | ||
| "Laptop for operation of maintenance equipment and rawing(AutoCAD), Specification: Core i5 ,Windows 10/11, 8GB, RAM, 1TB HDD/SDD, 4GB ,Graphics, preferred. Model: HP Pavilion 15- dk2100TX (48U95PA#ACJ) or similar. Prior approval of DYCEE/C/ADI is mandatory for make,Model etc." | — | — | — | 77,000 | |
| — | 1.00 | — | — | ||
| Providing FL Mast 20 mtrs | — | — | — | 2,26,346 | |
| — | 1.00 | — | — | ||
| Foundation for FL mast. | — | — | — | 50,772 | |
| — | 12.00 | — | — | ||
| Supply, installation, testing & commissioninog of LED Light Flood light fitting 250 W on high mast and other location, complete with all accessories. | — | — | — | 2,13,168 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .