Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹13.6 L+₹1,347 (0.10%)Rejected-AOC ALAPPUZHA | ALAPPUZHA | KERALA | 686534 | L2 | Rejected-AOC Second lowest | |
| 3 | L3₹13.9 L+₹29,280 (2.15%)Rejected-Finance | L3 | Rejected-Finance Third lowest |
Tender Value
Refer Docs
EMD Value
₹34,185
Closing Date
11 Apr 2023, 4:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
O/o the Assistant Executive Engineer PWD Electrical Sub Division Idukki Painavu
DEPOSIT-Civil station Idukki-Replacement of existing damaged UPS batteries in various sections of District collectorate idukki.-General Electrical Work
2023_PWD_570082_1
PWD/BLDG/TR/17938/2022_6_1_1/1
Open Tender
Electrical Works
Item Rate
40 days
Idukki
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,015
₹34,185
27 Apr 2023
31 Mar 2023
13 Apr 2023
31 Mar 2023
11 Apr 2023
31 Mar 2023
Amount
Replacement of damaged lead acid batteries.
OD137249/2022-2023:Supply, installation, testing and commissioning of new 12V 100 AH C10 rated SMF lead acid battery with 3 years on site warranty for existing UPS systems and replacement of existing old faulty SMF lead acid battery. ( Exide/Hykon make)
OD268273/2022-2023:Supply, installation, testing and commissioning of new 12V 40 AH C10 rated SMF lead acid battery with 3 years on site warranty for existing UPS systems and replacement of existing old SMF lead acid battery. ( Exide/Hykon make)
OD146993/2022-2023:Providing and connecting the suitable ampere rated interconnection cable including socket for 100 Ah battery and applying petroleum jelly at the joint of battery terminal and cable as required.
4.1.2:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
OD283579/2022-2023:Supply and installation of Clean agent Fire Extinguisher 6 Kgs. Capacity ceiling mounted type suitable for below ceiling built in 1 piece with body and bottom. Mild Steel Body owith pressure gauge, refillable device and safety release device, Brass valve suitable for B and C Classes of Fire complete with Charge of HFC Blend A, It is a blend of Hydro Fluoro carbon and organic detossificant essence P 26. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal. The Extinguisher as per IS:15683-2006 with ISI Mark.
4.1.3:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness
4.3.4:Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
OD283536/2022-2023:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), Suitable for AC + Pulsating DC (Type A) + Harmonics, having a sensitivity current 30/100/300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps ( L&T make Type Adi./ other equivalent make )
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Angel electricals
SHIJU M.T
Bidder Name
SHIJU M.T
All Star Electricals
Angel electricals
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_841511.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .