Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
24 Apr 2025, 3:00 pmClosed
DIRECTOR VECC
VECC , 1/AF , BIDHAN NAGAR , KOLKATA-700064
Providing electrical power connection to Server room at Rajarhat Campus, VECC, Kolkata.
2025_VECC_855967_1
VECC/MEG/ES/NIT/25-26/B-15/757 DT 07/04/25
Open Tender
Electrical Works
Item Rate
90 days
Rajarhat Campus, VECC, Kolkata.
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹26,000
30 May 2025
9 Apr 2025
25 Apr 2025
10 Apr 2025
24 Apr 2025
14 Apr 2025
10 Apr 2025 - 14 Apr 2025
Amount
Wiring for fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as reqd.
Supply & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed PVC conduit as required.
5 X 2.5 sq. mm
7 X 2.5 sq. mm
Supplying and fixing metal box of 180mm X 100mm X 60 mm deep nominal size on surface or in recesses with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supply, Installation, testing and commissioning of pre-wired, 2 Nos. 18 Watt LED Batten tube light fittings, with all accessories, including supplying and fixing of 2 Nos. ball and socket arrangement, 2 nos down rod of each 20mm dia X 1.6 mm thick steel conduit upto 2000 mm length, painting and wiring, connection with 2.5 Mtrs of 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire FRLS PVC insulated, copper conductor, single core flexible cable etc. as required as per direction of EIC and attached technical specification.
Supply, Installation, testing and commissioning of 1200 mm celling fan, including wiring the down rod of 2000 mm length GI pipe, 15mm dia, heavy gauge with 2.5 Mtrs of 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire FRLS PVC insulated, copper conductor, single core flexible cable etc. as required as per direction of EIC and attached technical specification.
Supply and fixing of M.S. Fan clamp of 16 mm dia., M.S. bar, bent to shape with hooked ends at MS plate and fixing it to the RCC beams/ celing with 4 Nos of 6mm anchor nut bolt, including painting the exposed portion, as required.
Supply,Installation, testing and commissioning of 450 mm sweep exhaust fan in the existing opening, including making good the damage, with supply and fixing metal louvers/shutters completed with frame for the exaust fan as required as per direction of EIC and attached technical specification.
Making hole for installation of exhaust fan of size 450 mm sweep by demolishing brick work manually/ mechanical means including disposal of debris within 50 mtrs lead and making good the wall by plastering, painting etc. as required.
Supply,Installation, testing and commissioning of 600 mm sweep wall mounted air circulator as per direction of EIC and attached technical specification.
Supply and fixing of 63 A four pole, 415 volt 10 KA, C curve, MCB with metal enclosure, cable end box complete with connections, testing and commissioning etc. as required.
Supplying and fixing three pole and neutral MCB DB with 40A FP MCB, 40A 100mA FP RCCB as incomer and 2 x 20A SP MCB, 10 x 16A SP MCB 240V C-curve, cable end box complete with connections, terminations etc as required as per direction of EIC.
Supplying and fixing three pole and neutral MCB DB with 63A FP MCB, 63A 100mA FP RCCB as incomer and 4 x 40A TP MCB, 415V C-curve, 1 x 25A SP MCB, 11 x 16A SP MCB 240V C-curve, cable end box complete with connections, terminations etc as required as per direction of EIC.
Supply, installation, testing and commissioning of 100 Watt LED flood light as per direction of EIC and attached technical specification.
Supply, laying, testing & commissioning of 1.1 KV grade, stranded copper conductor, XLPE insulated, inner sheath of PVC, GI armored, outer sheath of FRLS PVC fixed on wall/column/slab with saddle & all fixing accessories, etc as per direction of EIC of the work.
4 core 10 Sq. mm.
3 core 2.5 sq.mm
Supply, laying, glanding, termination, testing & commissioning of 50 Sq.mm 1.1 KV grade, PVC insulated, single core, stranded flexible copper conductor cable fixed on wall/column/slab/under ground with saddle & all fixing accessories, etc as per direction of EIC of the work.
Supply and end termination of 1.1 KV grade, stranded copper conductor, XLPE insulated, inner sheath of PVC, GI armored, outer sheath of FRLS PVC by gland and lugs as per direction of EIC of the work.
4 core 10 Sq. mm.
3 core 2.5 sq.mm
Supply and installation of light Junction box on wall as per direction of EIC and attached technical specification.
Supply and installation of light control box with contactor, MCB, Timer, toggle switch, terminal blocks etc.as per direction of EIC and attached technical specification.
Supply, installation, testing and commissioning of 1.0 HP submersible pump & level sensor on existing pit with laying and termination of 5 Mtrs. cable suitable for 1.0 HP submersible pump, laying and fixing of 5 Mtrs. suitable PVC pipe for water outlet from pump as direction of EIC of the work and attached technical specification..
Making of a pit of 300mm x 300mm x 150mm in the existing RCC cable trench with inside plastering & finishing for placement of 1.0 HP submersible pump inside the pit as per direction of EIC of the work..
Supply, installation, testing and commissioning of DOL starer suitable for automatic operation of 1.0 HP submersible pump with level sensor as per direction of EIC of the work.
Supply, fabrication, painting with one coat primer and two coats of enamel paint and fixing of 09 Nos. of flood light support structures with suitable anchor fastners as per direction of EIC of the work.
Supply, installation, testing and commissioning of G I plate type Earthing system as per attached drawing No: VECC/ES/01 and direction of EIC of the work.
Supply installation testing and commissioning of 20 KVA UPS unit with battery back up as per attached technical specification. & direction of EIC of the work.
S.D.ENTERPRISE (BID ID -3204479)
Shahi Electric Engineering Co. Pvt. Ltd. (BID ID -3206032)
S S ENTERPRISE (BID ID -3204661)
Satabdi Engineering company (BID ID -3205077)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .