Loading…
Loading…
Tender Value
₹26.2 L
EMD Value
₹27,000
Closing Date
9 Apr 2026, 6:00 pmClosed
Executive Engineer, Panchayat R & B Division, Vadodara
Construction of Ayurvedic Hospital at Kandari Village Ta.Karjan Dist. Vadodara under 15th Nanapunch 10 percent Jilla Kaksha Grant (2025-26)
291196
35 of 2025-2026
Open
Civil - All
Works
Vadodara
5 documents required · 5 mandatory
₹1,500
Yes
Executive Engineer, Panchayat (R&B) Division, Vadodara
₹27,000
Yes
28 Mar 2026
28 Mar 2026
28 Mar 2026
9 Apr 2026
28 Mar 2026
Name Of Work :- Construction of Ayurvedic Hospital at Kandari Village
Ta.Karjan Dist. Vadodara under 15th Nanapunch 10% Jilla Kaksha
Grant (2025-26)
1 All works shall be carried out as per latest MORTH Specification Booklet and other specification
of Division as directed.
2 All Rates quoted include clearance of site (prior commencement of work and at its close) in all
respects and hold good for work under all conditions, site moisture, weather etc.
3 The contractor shall exhibit a board as per Government Circular No. Vernacular TNC/1090/24/S
dated 05.03.2011 with details specifications and details of works and amount involved at site at
his own cost as directed by Engineer-in-charge.
4 Testing of material shall be done as per statement attached with specification. The material should
be tested in GERI or Private laboratory approved by Govt. of Gujarat. Bill for testing charges
should be paid by Executive Engineer and computed after deducting the cost of materials to be
supplied by the Govt. and shall be recovered from the contractor's running bill as per Govt., R&B
Department No. TNC-1085/(4)/C dtd 20-12-91.
5 1.00 % of Construction cost shall be deducted form Bill. Amount of Contract as per the Building
and other Construction worker's welfare cess Act - 1996 (Labour & Employment Department
Letter No. CWA - 2004 - 1831 - M (3). Dt. 9-12-05, Notification of Labour & Employment
Department Dtd. 03-01-05 and Labour & Employment Department letter No. CWA / 2004-841-
6 In all R.C.C. items in rate analysis, standard cement consumption has been taken as per Govt. GR,
PRC-10/2017/Cement Consumption/16/C, Dtd. 11/05/2017 as stated in SOR therefore in RCC
items where there is a change as per actual mix design the cost of difference of cement
consumption shall be deducted from the rate of original item at the rate of input rate mentioned in
7 Bidders are advised to visit the site & make himself / themself aware of the scope & specification
of the work to be done & of conditions and other factors bearing on the execution of the work
before on line submission of his / their bids. Once the bid is finalized, under no circumstances
arguments for crust deficiency / additional / altered works will be heard until & unless Engineer in
charge deem so. Engineer in charge shall have right to reject & decision of Engineer in charge
shall be final & binding.
8 If found necessary, contractor will be intimated for negotiation. He will be intimated maximum
three times within validity period for negotiation. If contractor does not respond in time, his
earnest money will be forfeited and his tender will be rejected. Paneltative action will be taken on
such contractor.
Name Of Work :- Construction of Ayurvedic Hospital at Kandari Village Ta.Karjan Dist. Vadodara
under 15th Nanapunch 10% Jilla Kaksha Grant (2025-26)
Taluka :Karjan District : Vadodara
INDEX OF SPECIFICATION
Applicable Separate Road
Tender Specification booklet attached
Discription of item as per schedule "B" of the tender.
Item No reference
Item No. Pg No.
1 Excavation for foundation up to 1.5 M Depth including sorting out and stacking of Attached Separetely
useful materials and disposing of the excavated stuff up to 50 meter lead (A) Loose or
2 Excavation for foundation 1.5 M to 3 M Depth including sorting out and stacking of Attached Separetely
useful materials and disposing of the excavated stuff up to 50 meter lead (B) Loose or
3 Providing and laying cement concrete 1:3:6 (1 Cement : 3 coarse sand :6 crushed stone Attached Separetely
aggregates 40 mm nominal size) and curing complete excluding cost of form work in(A)
Foundation and plinth (more than 10 ton)
4 Providing and laying Cement Concrete 1 : 3 : 6 ( 1 Cement : 3 Coarse Sand : 6 Crushed Attached Separetely
stone aggregates 20 mm nominal size ) and curing complete including cost of form work
in ( a ) Wall Caps / Copings)
5 Provinding and Laying controlled cement concrete M-250 including finising smooth Attached Separetely
with curing complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in foundations, footings, base of columns
and mass concrete.
6 Provinding and Laying controlled cement concrete M-250 including finising smooth Attached Separetely
with curing complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in columns up to plinth.
7 Provinding and Laying controlled cement concrete M-200 including finising smooth Attached Separetely
with curing complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in columns having any cross sectional area
8 Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- crushed Attached Separetely
broken stone aggregates 40 mm nominal size) and curing complete including cost of
New Ply formwork in (A) Dummy column
9 Provinding and Laying controlled cement concrete M-200 including finising smooth Attached Separetely
with curing complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Plinth Beam having any cross sectional
10 Provinding and Laying controlled cement concrete M-200 including finising smooth Attached Separetely
with curing complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Beam having any cross sectional area
11 Providing and laying controlled cement concrete M-200 and curing complete including Attached Separetely
the cost of formwork but excluding the cost of reinforcement for reinforced concrete
work in Grid Slab.
12 Providing and laying controlled cement concrete M-200 and curing complete including Attached Separetely
the cost of formwork and excluding the cost of reinforcement for reinforced concrete
13 Providing and laying controlled cement concrete M-200 and curing complete including Attached Separetely
the cost of formwork and excluding the cost of reinforcement for reinforced concrete
work in Lintel and sill
14 Filling available excavated earth (excluding rock) in trenches. plinth, sides of Attached Separetely
foundations etc. in layers not exceeding 20 cm. in depth consolidating each deposited
layer by ramming and watering.
15 Filling in foundation and plinth with Murrum or selected soil in layers of 20cm thickness Attached Separetely
including watering ramming and consolidating etc. complete
Applicable Separate Road
Tender Specification booklet attached
Discription of item as per schedule "B" of the tender.
Item No reference
Item No. Pg No.
16 Providing TMT bar FE 500D reinforcement for R.C.C. work including, bending, Attached Separetely
Binding and placeing in position complete up to foor two level
17 Half Brick masonry in common burnt clay building brick having crushing strength not Attached Separetely
less than 35 kg/sq. cm. in cement mortar 1:4(1 Cement : 4 coarser sand) in foundation
and plinth (B) Conventional
18 Brick work using common burnt clay building brick having crushing strength not less Attached Separetely
than 35 kg/sq. cm. in foundation and plinth in cement mortar 1:6(1 Cement : 6 fine sand)
(B) Conventional
19 Providing 15mm thick cement plaster in single coat on Rough (Similar) side of single or Attached Separetely
half brick walls for interior plastering and finished even and smooth in finishing with a
floating coat of neat cement slurry (ii) Cement mortar 1:4 (1-cement :4-sand), including
labour and material etc. complete as directed by engineer in-charge.
20 Providing 10 mm thick cement plaster in Single coat on fair side Brick/Concrete walls Attached Separetely
for interior plastering on ceiling and soffits of stair upto floor two level finished even
and smooth and finishishing with floating coat of neat cement slurry & Providing 10 mm
x 10 mm Groove at junction of Structural member (1) Cement Mortar 1:3 (1 Cement :
21 20 mm thick Sand faced cement plaster on wall upto height 10 mts.above ground level Attached Separetely
consisting of 12 mm thick backing coat of C.M 1:3 (1 cement : 3 sand )and 8 mm thick
finishing coat of C.M 1 : 1(1 cement : 1 Sand) etc. complete.
22 Applying two coats of putty & two coats of primer of approved brand and manufacture Attached Separetely
on new wall surface to give an even shade including thoroughly brushing the surface
free from mortar dropping and other foreign matter and sand papered smooth.
23 Applying two coats of primer of approved brand and manufacture on new wall surface Attached Separetely
to give an even shade including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered smooth.
24 Wall painting two coats with plastic emulsion paint of approved brand and manufacturer Attached Separetely
on wall surfaces to give an even shade including thorougly brushing the surface free
from mortar & other foreign matter and sand papered smooth
25 Wall painting (two coats) with plastic emulsion paint of approved brand and Attached Separetely
manufacture on undecorated ceilings and sloping roofs surface to give an even shade
including thoroughly brushing the surface free from mortar droppings and other foreign
matter and sand papered smooth.
26 Finishing wall with weather proof exterior emulsion paint (two coats) on wall surface Attached Separetely
including primer to give an required shape even shade after thoroughly brushing the
surface to remove all dirt, and remains of loose powdered materials. Etc. complete
27 Providing and laying Polished Kota stone slab flooring over 20mm (Average) thick base Attached Separetely
of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement
slurry mixed with pigment to match the shade of slab including rubbing and polishing
etc. complete. (A) 30mm thick
28 Providing and laying polished kota stone slab 25mm thick in risers of steps, skirting Attached Separetely
Dado and pillars laid on 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and
jointed with gray cement slurry mixed with pigment to match the shade of slab including
rubbing and polishing etc. complete.
29 P & L 24" x 24" Vitrified tiles 8 mm thick tile flooring over 20mm (average) base of Attached Separetely
cement mortar 1:6 (1 Cement: 6 Coarse Sand) on new surface or fixing on existing
flooring by adhesive material includung dismentaling of existing flooring & jointed with
color cement slurry includung finished with flush pointing & cleaning the surface etc.
complet for light shade (up to 10 ton)
30 Providing and laying ceramic tiles 6 mm thick in Skerting,risers of Steps & dedo laid Attached Separetely
on bed of 12mm thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) and jointed with
white cement slurry (up to 10 ton)
Applicable Separate Road
Tender Specification booklet attached
Discription of item as per schedule "B" of the tender.
Item No reference
Item No. Pg No.
31 Providing and laying white Glazed tiles 6 mm thick in Skerting,risers of Steps & dedo laid on Attached Separetely
bed of 12mm thick Cement Mortar 1:3 (1 Cement: 3Coarse Sand) and jointed with white cement
slurry (up to 10 ton)
32 Providing and fixing 38mm thick water proof flush door solid core double shutter on Attached Separetely
granite stone with 1mm thick laminated sheet on both side of the shutter having
teakwood lipping edge patti of 38 mm x 25.4 mm on all edges withMelamine Polish
matching shade of laminate with Magnetic catcher triple strip vertical type(1 No), Brass
tower bolt (barrel type) 150x10 mm(1 No), Godrej Classic Keyless Cylindrical Lock
5805 (1 No) with necessary SS fixtures and fastenings etc. complete as directed by
Engineer-in-charge.
33 Providing and fixing window having extrueded aluminium coloure anodized section frame main Attached Separetely
outer size 63.50 xz 38.10 x 1.95mm ( of Jindal section no 4605,@ wt.1.094 kg/rmt) horizonteal
Two track member size 60.85 mm x 31.75 mm x 1.20mm (of jindal section no: 8637 @wt. of
0.695 Kg/mt ) vertical member of size 61.85mm x 31.75 mm x 1.30 mm (of jindal section no :
8785 @ wt. of 0.659 kg/mt ) with sliding shutters of horizontal member size 40 mm x 18 mm x
1.29 mm ( of jindal section no: 8949 @ wt of 0.459 kg/mt ) veriucal member of size 40 mm x
mm x 1.29 mm (of jindal section no: 8947 @ wt. of 0.459 kg/mt /section 8948, @ wt.
kg/mt ) with 5 mm thick transparent bronze colour tinted float galss with powder coated
aluminium fittings and fixturres and transparent silcon sealant falss fixing to frame as per details
etc.complete for window.
34 Providing and fixing standared extruded of alluminium section of size 63mm x 38.10mm x Attached Separetely
1.2mm @ Wt. 0.643 Kg/mt with colour anodized alluminium frame for ventilation with 5 mm
thick frosted glass as details etc complete for Ventilation
35 Providing and laying Granite stone (15 to 18 mm. thick) slab single piece laid in sill Attached Separetely
and jambs of doors frame laid on 10 mm. thick cement mortar 1:3 (1 cement : 3 coarse
sand) and jointed with grey cement slurry including removing plaster and making good
same and rubbing and polishing etc. complete.
36 Providing and laying Marble Slab stone 25mm thick double polished approved quality Attached Separetely
incl. full moulded round front edge fixed in wall as table top for wash basin and jointed
with white cement slurry including rubbing and polishing etc. complete
37 Providing and laying chequered precast cement concrete tiles 22mm thick with Attached Separetely
aggregate of sizes upto 6mm in floors, treads of steps and landings on 20mm thick bed
of C.M. 1:6 (1-cement : 6-sand) or L.M. 1:1.5(1-Lime putty : 1.5 coarse sand) joint with
neat cement slurry with pigments to match the shade of the tiles.
38 Providing and fixing M.S. plain grills of required pattern to M.S. flats of windows etc. Attached Separetely
with M.S. flats at required spacing and frame round, square or round bar, with round
headed bolts and nuts or by screws plain grill with one coat of red lead paint & two
coats on new steel and other metal surface with enamel paint, brushing, interior to give
an even shade including cleaning the surface an even shade including cleaning the
surface of all dirt, dust and other foreign matter.
39 Providing and fixing 1 meter height post and pipe railing including 3 coats of painting to Attached Separetely
steel works complete. As Approved by engineer Incharge
40 Providing and laying broken chine mosaic flooring for terrace using 12 mm to Attached Separetely
20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope
and to be tempered to bring mortar creme out upto surface using white cement
including rounding off junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid etc. as directed.
Applicable Separate Road
Tender Specification booklet attached
Discription of item as per schedule "B" of the tender.
Item No reference
Item No. Pg No.
41 Providing and fixing wash down water closet wall hung (European type, W.C. Pan) with Attached Separetely
integral P or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1-
Cement : 1-fine sand) (A) vitreous China Pattern :(i) in white colour, including plastic
seat and cover for wash down water closer with C.P. brass hinges and rubber buffers,
Providing and fixing G.I. inlet connection for flush pipe with W.C. Pan, Providing and
fixing 32mm dual flow metropole valve including concealed body with exposed shutoff
provision and round flange of approved quality including fixing in pipe line etc.
complete and providing and fixing Health Faucet Heavy duty having pipe length of
rmt with hook with fitting etc. complete as directed by engineer in-charge. (Cera,
Hindware, Plumber make)
42 Providing and fixing PVC SWR Nahni Trap IS 14735 for drain with jali of the Attached Separetely
following nominal diameter of self cleansing design with C.I. scread down or hinged
grating including the cost of cutting and making good the walls (i) 100 mmr 1:1 (
1cemtn : 1fine sand)
(A) Viterous China
43 Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water Attached Separetely
tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i)
Square mouth traps. (A) 100mm x 100mm size P type.
44 Providing and fixing table top Wash Basin single hole for piller tap and making good Attached Separetely
the same but including fitting (A) Vitreous chaina : (II) Flat back wash basin 550mm x
400mm size in white colour including provinding and fixing C.P. brass waste coupling
of 32mm dia., chromium plated bottle trap with necessary couplings of approved
quality, M. I. fisher union of 32mm dia., C.P brass pillar tap of 15mm dia., PVC
connection pipe from stop cock to pillar tap etc. complete. (Cera, Hindware, Plumber
45 Providing and fixing screw down bib taps of following size. (A) Brass screw down bib Attached Separetely
tap polished bright (ii) 15 mm dia
46 Providing and fixing chromium plated brass half turn flush cock of approved quality Attached Separetely
including fixing in pipe line etc. complete (ii) 25 mm Dia
47 Providing and fixing gun metal check or non return fullway wheel valve (E) 40 mm Dia Attached Separetely
48 Providing and fixing to wall ceiling floor 10.0 kgf/cm2 working pressure polythene Attached Separetely
pipes of the following outside dia low density complete with special flage compression
type fittings, wall clips etc. including making good the wall ceiling and floor (G)
49 Providing and fixing to wall ceiling floor 10.0 kgf/cm2 working pressure polythene Attached Separetely
pipes of the following outside dia low density complete with special flage compression
type fittings, wall clips etc. including making good the wall ceiling and floor (F) 75 mm
50 Providing and fixing to wall, ceiling and floor galvanized Mild steel tubes (Medium Attached Separetely
grade) of the following nominal bore, tube fitting and clamps including making good the
wall ceiling and floor.(F) 40mm
51 Providing, laying and jointing in true line and level 40 mm dia. UPVC pipe (SCH-40) Attached Separetely
line including fittings make or equivalent as approved by engineer-in-charge. Pipes
shallbe fixed on the wall with the help of clamp at every two meter C/C or shall be
concealed as directed including necessary fittings etc. including testing of pipe and
joints and fixing the same with adhesive solvant, including cost of all materials.
52 Providing, laying and jointing in true line and level 25 mm dia. UPVC pipe (SCH-40) Attached Separetely
line including fittings make or equivalent as approved by engineer-in-charge. Pipes
shallbe fixed on the wall with the help of clamp at every two meter C/C or shall be
concealed as directed including necessary fittings etc. including testing of pipe and
joints and fixing the same with adhesive solvant, including cost of all materials.
Applicable Separate Road
Tender Specification booklet attached
Discription of item as per schedule "B" of the tender.
Item No reference
Item No. Pg No.
53 Providing, laying and jointing in true line and level 15 mm dia. UPVC pipe (SCH-40) Attached Separetely
line including fittings make or equivalent as approved by engineer-in-charge. Pipes
shallbe fixed on the wall with the help of clamp at every two meter C/C or shall be
concealed as directed including necessary fittings etc. including testing of pipe and
joints and fixing the same with adhesive solvant, including cost of all materials.
54 Constructing brick masonary for underground C.I Inspection chamber and bends with Attached Separetely
bricks having crushing strength not less then 35 kg/cm2 in c:m 1 :5 FRC cover with
frame (light duty) 445 mm x 610 mm internal dimensions total weight of cover with
frame to be not less than 38 Kg (Wt. Of cover 23 Kg.) and Wt. of frame 15 Kg. R.C.C.
top slab with 1:2:4 mix (1-cement : 2-coarse sand : 4-graded stone aggregate 20 mm
size) foundation concrete 1:5:10 inside plaster 15 mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement on walls and bed concrete etc.
complete. (iii) Inside dimensions 600 mm X 850mm and 450 mm deep for pipe lines
with three or more inlets
55 Providing soakpit of 5.00 cumvolume including excavating sand filling brick bats with Attached Separetely
dry masonary work at top for 5cm height including covering the top with stone including
providing vatas in CM 1:3 with finishing curing etc complete as directed
56 Providing septic tank of inside dimensions as Directed by incharge with brick masonary Attached Separetely
of CM 1:6 the foundation floor with 1:5:10 B.B.C.C. finished with 15 mm C.P. in C.M.
1:4 root cover of R.C.C. slab incl. connection pipe from inlet and outlet etc.comp.
57 Contructing A ground level sump for storage a drinking Water with monoblock motor Attached Separetely
pump set with wooden box cover for motor etc. com.
58 Providing erecting and fixing double coated Syntex or equivalent PVC (ISI) mark water Attached Separetely
tank of required capacity each with all necessary fittings& connection etc. complete on
59 SUPPLY AND INSTALLATION OF ABC - 6 Kg. capacity as per IS Make Pro/ Red Attached Separetely
Bottle FIRE EXTINGUISHER
60 SUPPLY AND INSTALLATION OF Co2 - 4.5 Kg.capacity as per IS Make Pro/ Red Attached Separetely
Bottle FIRE EXTINGUISHER
61 Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block Attached Separetely
60mm thick with grade of concrete M300 pnumatic compressed / vibrated mechanically
and as per approved design Confirming to IS 15658 : 2006 including 35 mm Sand layer
for levelling and filling the joint with sand in proper line and level as per guidlines of
IRC : SP 63-2018 etc. Complete.
62 Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block Attached Separetely
30cm length, 30cm height and 15 cm thick of M 250 grade concret as per approved
design and including excavation for fixing in proper line and level, filling the joint with
C:M 1:3 (1 Cement : 3 fine sand) etc complete
63 Providing & fixing 2 mm thick UPVC shade with necessary MS Hollow section frame Attached Separetely
work with necessary fastening and fittings etc. complete with two coats of automotive
64 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) Attached Electrical
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up Specification Booklet
to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push
& accessories and earth continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame covered with textured/metallic/white
front plate modules erected on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed. , (f) with medium class Rigid
PVC pipe and accessories erected concealed in wall/ceiling completeCat-III [1-2-1]
Applicable Separate Road
Tender Specification booklet attached
Discription of item as per schedule "B" of the tender.
Item No reference
Item No. Pg No.
65 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of Attached Electrical
.ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr Specification Booklet
length, in below type of pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with earth continuity of
following type erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected on / in wall / ceiling as
per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (f) with
medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
completeCat-III [1-2-2]
66 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin socket Attached Electrical
erected on PVC / Metallic/Wooden box, single mounting base frame covered with Specification Booklet
textured/ metallic/ white front plate modules erected on/ in wall/ ceiling with following
type accessories, Cat-III [1-2-4]
67 Providing following type of Modular Type Accessories mounted with pvc / metallic Attached Electrical
box, single mounting base frame covered with textured / metallic front plate , modules Specification Booklet
erected with necessary connection. As desired by Engineer In charge (10) 6/16Amp.
Universal socket Cat.III [1-2-6]
68 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of Attached Electrical
ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr Specification Booklet
length, in below type of pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected with following type of accessories.[II]
For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.(f)
with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling
complete,cat-iii[1-2-3-iii]
69 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked Attached Electrical
stranded Copper conductor wire in following type of pipe to be erected concealed in Specification Booklet
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of following size, (A) With medium
class Rigid PVC pipe and accessories , (b) 2 wire 2.5 sq. mm [1-4-1]
70 Providing and erecting Sheet Steel powder coated MCB distribution board - flush / Attached Electrical
surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS Specification Booklet
8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs. (The
DBs should be used of same company of MCB to be used) suitable for, (A) single phase
incoming and horizontal single phase outgoing(a) single door (IP-30) (iv)12 way[3-11-
71 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having Attached Electrical
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for Specification Booklet
operation on single phase 240 V,50Hz. having characteristic of quick action & tripping
with all advance feature & do not incorporate any electronic component. for following
Max. rating erected as directed, (ii) 40Amps. DP Cat-III [3-12-1]
72 Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to Attached Electrical
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in Specification Booklet
existing box. confirming to IS 8828/1996 with ISI Mark, Cat-III[3-10-1-(B)]
73 Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) Attached Electrical
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having Specification Booklet
following capacity (B) 40 Amp. ,cat-iii,[3-10-3]
74 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked Attached Electrical
stranded Copper conductor wire in following type of pipe to be erected in / on wall / Specification Booklet
ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size, (A) with medium class Rigid PVC pipe and
accessories,(a) 2 wire 4 sq. mm [1-4-2]
Applicable Separate Road
Tender Specification booklet attached
Discription of item as per schedule "B" of the tender.
Item No reference
Item No. Pg No.
75 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt Attached Electrical
assembled on single MCPCB, with housing used as a heat sink shall be made of thick Specification Booklet
sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V,
Power Factor more than 0.95, THD < 15%, CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt ,LED LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.),(A) Tube Light with integral driver,(iii) 18-
20 Wattsconventional 4 feet, Surge-2 KV, IP-20, ,Cat-lll,[2-15-1]
76 Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark Attached Electrical
with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy erected on Specification Booklet
existing hook or clamp with earthing. [Make shall be approved by Engineer in
charge],[5-1-1]
Deputy Executive Engineer Executive Engineer
Panchayat ( R & B) Sub Division Panchayat ( R & B) Division
Karjan Vadodara
Name Of Work :- Construction of Ayurvedic Hospital at Kandari Village Ta.Karjan Dist. Vadodara under 15th Nanapunch 10%
Jilla Kaksha Grant (2025-26)
Taluka :Karjan District : Vadodara
SCHEDULE FOR TESTING OF MATERIALS
For ensuring quality control and workmanship, various tests prescribed below for materials shall be taken at periodical intervals as stipulated below.
The material should be tested in GERI or Private laboratory approved by Govt. of Gujarat. Bill for testing charges should be paid Govt.
Item No. as Brief Description of materials to be Qty. of Unit Prescription of test which Frequency @ which test shall be Total Nos of
per tested. Materials shall be carried out carried out test to be
Schedule 'B' taken
1 Bricks 34150.00 Nos. *Water absorption 1 test @50,000 Bricks
*Strength Comprehensive
2 Kapchi 20 mm Nominal 76.52 Cum *Gradation test 1 to 100 - cum. 1 test
*Impact Value 100 to 500 - cum. 3 test
*Flakiness Index of 500 to 1500 - cum. 5 test
1500 to 5000 - cum. 7 test
3 Cement (OPC 53 grade) 48.800 M.T. *Consistency,Soundness 1 test @ 50.0 M.T. 100 T 2 tests,
*Setting time,Finessness Test 200 T 3 tests, 300 T 4 tests, 500 T 5 tests,
*Compressive Strength. 800 T 6 tests, 1300 T 7 tests & 8 testd for
large consingment.
4 Steel (TMT FE 500 D) 7.71 M.T. *Tensile, (TMT) As per Manual of Quality Control
Yield 1 test/40 tonnes / per category
48. Sch B Ayurvedic hospital @ Kandari Village Ta.Karjan.xls
Item No. as Brief Description of materials to be Qty. of Unit Prescription of test which Frequency @ which test shall be Total Nos of
per tested. Materials shall be carried out carried out test to be
Schedule 'B' taken
5 C.C.Cube Test 1:2:4 *Compressive Strength. 1 to 5 cmt - 1 No
M150 16 to 20 cmt - 3 No
M250 16.00 51 to above - 4 +1 additional sample
for each 50 cu.mt. Or part there of.
Note (1):- In case of excess in quantity. Further more test shall be carried out as per required frequency.
Note (2):- Apart from above listed materials for carrying out various tests during Road / Structure
Construction Works , if any other than above mentioned material/s are to be used during road /
structure construction work then it must be tested as per prevailing criteria of Govt. of Gujarat (R &
B Deptt.) and necessary tests should be carried out as per prevailing norms.
Signature of Contractor. Deputy Executive Engineer Executive Engineer
Panchayat (R & B) Sub Division Panchayat (R & B) Division
Karjan Vadodara
48. Sch B Ayurvedic hospital @ Kandari Village Ta.Karjan.xls
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
48.2 SBD Book Ayurvedic hospi at Karjan Village Ta.Karjan.pdf
48.2 Speci. Const. Aryuvedic Hos. at Kandari Village Ta. Karjan.pdf
48.3 Electrical Tender General and Technical Condition Specificatioin.pdf
BOQ Notes - Index - Test Sch..pdf
BOQ.pdf
GR_to_be_attached_with_DTP_SBD_with_Index[1].pdf
merge drawings.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .