RequiredOEM Authorization Certificate Bid to RA enabled Yes Ultrasound Scanning Machine ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Standards Product certification - * Certification number and date - * Confirmity to Manufacturer's Certification ISO 9001 & ISO 13485 * Confirmity to Performance and safety standards specific to the device IEC 60601-2-37 or equivalent BIS * 1/9 Performance Parameters Scope of supply General-purpose ultrasonic scanning systems provide two- dimensional (2-D) B- mode images of soft tissues without subjecting patients to ionizing radiation. It intends to primarily for abdominal
Requiredobstetric/gynecologic (OB/GYN)
Requiredsmall-parts
Requiredand vascular imaging * UMDNS Code and names(Hint: This is for indicating the relevant universal medical devices nomenclature for the category of product ) "Scanning Systems
RequiredUltrasonic
RequiredAbdominal [16-241] Scanning Systems
RequiredUltrasonic
RequiredGeneral-Purpose [15-976] Scanning Systems
RequiredUltrasonic
RequiredObstetric/Gynecologic [15-657] Scanning Systems
RequiredUltrasonic
RequiredSmall-Parts [18-052] Scanning Systems
RequiredUltrasonic
RequiredVascular [15-957]" * Types of Probes & Features Applications- Abdomen
Requiredabdominal vascular
Requiredurology
RequiredOB/GYN
Requiredneonatal brain
Requiredsmall parts (breast
Requiredthyroid
Requiredscrotal
Requiredprostate
RequiredMSK) Yes * Flat linear array 5-10 MHz (±2) * Convex array 2.5-5 MHz (±2) * Microconvex array Yes Yes Or higher Volume Convex Probe Yes Yes Or higher Volume Linear Probe No Yes
RequiredNo Or higher Volume TV Probe Yes Yes
RequiredNo Or higher E- Breast Elastography Yes Yes Or higher E- Thyroid Elastography Yes Yes Or higher Liver Elastography No Yes
RequiredNo Or higher Intraoperative Probe No Yes
RequiredNo Or higher Gel Warmer Yes Yes Or higher Dedicated 3-D/4-D Yes Yes Or higher Scan Modes B-mode Yes * 2/9 M-mode Yes * Contrast harmonic imaging with angio mode Yes Yes Or higher Tissue harmonic imaging mode Yes * Provision of Harmonic imaging in Linear Probes Yes * Color Doppler imaging (CDI) Yes * Color Doppler 3-D/4-D option Yes * Power Doppler imaging (PDI) Yes * Power Doppler 3-D/4-D option Yes * Continuous wave Yes * Pulsed wave Yes * Duplex mode Yes * Triplex mode Yes * Tissue Doppler imaging Yes * Contrast-enhanced ultrasound (CEUS) option Yes Yes Or higher Tissue synchronization
Requiredtissue velocity Yes Yes Or higher Gain control in two dimensions for additional level of flexibility for image quality control Yes * "Provision for higher resolution " Real time high frequency 2D * Probes supplied shall be in latest generation bandwidth Yes * Provision for higher sensitivity for low frequency doppler in all probes No Yes
RequiredNo Or higher Number of Channels in color doppler system 50000 or more (If channels are being designated as digital channels) 50000 or more (If channels are being designated as digital channels) 3/9 Live 3 D imaging in color doppler system Yes Yes Or higher Colour Doppler system with all application packages
RequiredQuad loop for serial studies with high frame rate revies
Requiredharmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval Yes Yes Or higher Number of grey shades for sharp contrast resolutions in db 256 or more * High-definition acoustic zoom provision for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate Yes * Colour Flow Imaging Optin Yes * Provision of Tissue Colorization (B- Colour) for improved contrast resolution Yes Yes Or higher All application packages should be inbuilt into the system Yes * Cine Loop Features Yes Yes Or higher Cine Loop Memory in MB 500 * Frame grabber facility for post analysis Yes Yes Or higher Facility of Various maps for pre and post processing Yes * User defined system and application presets for multi-user department Yes * Number of transducer/probe 4 4 4/9 ports System should be capable of generating real time live 3- D images Yes Yes Contrast agent imaging Yes Yes Or higher Color Doppler system with all applications package
Requiredquad loop for serial studies with high frame rate
Requiredharmonic imaging capability in all modes and digital storage and retrieval Yes * IMAGE DISPLAY AND PROCESSING DICOM 3 COMPLIANT Yes Yes Or higher Adjustable transmit focus Yes * Automated B-mode (2-D) image Yes Yes Or higher Automated CDI image optimization Yes Yes Or higher Automated PW Doppler image optimization Yes Yes Or higher Dynamic receive focus Yes * Grayscale levels 256 * Image magnification (zoom) Yes * Real-time image Yes * Frozen image Yes * Touch Screen Yes Yes Or higher Monitor shall have high- resolution Yes * "Provision of Tilt and Swivel monitor should be able to view in all angles and all light conditions" Yes * Monitor display size
Requiredcm (in) 54.6 (21.5) LCD with handle 54.6 (21.5) LCD with handle Split screen Twin View Twin View Single/dual monitors Dual (image display and touch panel) Dual (image display and touch panel) Depth
Requiredcm ≥30 (11.8) * Pre processing Yes * 5/9 Post processing Yes * Selectable dynamic range Yes * Spectrum analyzer Yes * DIGITAL IMAGE STORAGE Yes * Cine loop playback Yes * Max number frames 1000 * Digital storage hard drive
RequiredGB 500 * Speckle-tracking strain and strain rate Yes * Exam protocols Yes * Automated Yes * Digital calipers Yes * Exam presets Yes * Customizable presets Yes * On-screen annotation Yes * DVD/CD Writer Yes Yes Or higher Flash Memory Yes * USB connector Yes * "Facility for high definition digital acquisition
Requiredreview and editing of complete patient studies" Yes * Type of processor i7 or latest i7 or latest RAM capacity of PC in GB (hint: In caase PC not provided put zero) ≥ 4 ≥ 4 Processor speed in GHZ ≥ 3 ≥ 3 Frame Grabber incorporated Yes Yes Or higher Connectivity between USG and PC Yes Yes Or higher PC with all software inclusive interfaced with USG machine Yes Yes Or higher laser Color printer provided with computer for reporting Yes Yes Or higher 6/9 Inkjet printer provided with computer for reporting Yes Yes Or higher CD/DVD Produced should be playable on any system Yes Yes Or higher Glossy Colour Print Paper supplied NA 500 sheets
Required1000 sheets
RequiredNA Dicom Interfacability Dicom to PACS Yes Yes Or higher Interfacability Dicom to RIS Yes Yes Or higher USG sytem supplied should be upgradable to next generation system on site Yes * Power Requirements Power input
RequiredVAC 220-240VAC
Required50Hz fitted with Indian plug * Resettable over current breaker shall be fitted for protection Yes Yes Or higher Power backup UPS UPS Back up time in minutes 30 30 Suitable Servo Controlled Stabilizer CVT should be provided Yes Yes Or higher Miscellaneous Parameters Warranty in years 3 3 Number of installations of the USG machines in Central/State/PSU Govt Hospitals( Note: Seller should supply a performace certificate of the device to the buyer if demanded after placement of order) More than 3 More than 3 User/Technical/Mainten ance manuals to be supplied in English in hard and soft copy Yes * Demonstration of equipment and training to be provided after completing supplies & Yes * 7/9 Installation before acceptance The Principal Manufacturer must have direct Presence/approved service center In India Yes * Copies of reports and certifications to be furnished to buyer on demand at time of supplies Yes * Certificate from the principal that spare parts will be available for next 10 years shall be provided at the time of supplies Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents