Loading…
Loading…
Tender Value
₹5.8 L
EMD Value
₹11,700
Closing Date
21 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
EL/MTC
3 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor has to submit a copy of valid Electrical Contractor License for carrying out installation work of voltage class involved, issued by any State/Central Government along with a supervisor competency certificate as per Regulation 29 of the Central Electricity Authority (Measure relating to Safety and Electric Supply) Regulation 2010 or latest as per Rules 45 of the Indian Electricity Rules 1956 along with the tender documents, failing which the offer is liable to be rejected.
Electrical arrangement for Proposed RPF Post in Workshop RCF Kapurthala.
RCF-EL-MTC-94-ET-26-27~RCF
RCF-EL-MTC-94-ET-26-27
Open
Works - General
90 Days
Kapurthala, Punjab
₹0
₹11,700
26 Sept 2026
26 Sept 2026
7 Oct 2026
43 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 5,84,438.6 | ||
| — | 12.00 | — | — | ||
| Supply, fixing testing and commissioning of 4 ft long 18/20 watt LED batten type tube light, light appearance white suitable for 230 v 50hz. As per Explanatory Note. | — | — | — | 2,400 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing andcommissioning of 1200mm BLDC ceiling fan As per Explanatory Note. | — | — | — | 8,800 | |
| — | 1.00 | — | — | ||
| Supply, fixing, testing and commissioning of Steel body, floor standing Desert cooler. The nominal air capacity is 4000 cubic meter per hour. As per Explanatory Note. | — | — | — | 5,870 | |
| — | 10.00 | — | — | ||
| Supply ,wiring ,testing ,fixing and commissioning of 6 Amp. plug point wiring with 2x2.5Sqmm 1100volt grade multistranded Copper wire conforming to IS 694-2010 from SPN DB with 2x4 Sqmm copper wire conforming to IS 694-2010and 1 Sqmm PVC insulated copper wire green colour as earth wire to be laid in existing conduit. Also Supply, fixing ,testing and commissioning of 5 pin socket and 6amp.240volt switch socket modular type with modular face plate and grid plate ISI marked to be fixed on suitable GI recess /PVC BOX /Flush wall box. 6amp 1 way switch on suitable GI recess/PVC box/flush wall box .All points to be connected with earth wire. Also keep loop to 150 mm long on every end point circuit and point wiring. Make: CPL, SSk, L&T, Anchor, Havells. Standard, Hager Only. As per Explanatory Note. | — | — | — | 4,000 | |
| — | 4.00 | — | — | ||
| Supply , wiring, testing , fixing and commissioning of 6 pin 16 amp plug point wiring with 2x4 sqmm 1100 volt grade multistranded copper wire conforming to IS 694-2010 and 1 Sqmm PVC insulated copper wire to be laid in existing conduit. As per Explanatory Note | — | — | — | 1,960 | |
| — | 200.00 | — | — | ||
| Supply & providing of MS conduit pipe of 16 SWG 25mm dia ISI marked of mentioned makes only, including bends ,elbows and jn box (conduit pipe shall be clamped at every one meter distance with saddling on ceiling/wall of the area). As per Explanatory Note. | — | — | — | 12,000 | |
| — | 4.00 | — | — | ||
| Supply, fixing testing and commissioning of ventilation fan with grill size 12" FRP body and grill suitable for single phase 230 V AC 50 Hz supply As per Explanatory Note. | — | — | — | 5,200 | |
| — | 20.00 | — | — | ||
| Supply , wiring ,testing & commissioning of L/F Point wiring with 2x2.5Sqmm 1100 volt grade multistranded Copper wire conforming to IS 694-2010 and 1 Sqmm PVC insulated copper wire green colour as earth wire to be laid in existing conduit. Also Supply , fixing ,testing and commissioning of modular face plate and grid plate as required at site 5/6amp 1 way modular switch on suitable GI recess/PVC box/flush wall box .All points to be connected with earth wire. Also keep loop to 150 mm long on every end point circuit and point wiring.. Make: CPL, SSk, L&T, Anchor, Havels, Hager, Schneider, KEI, Rallison Only. As per Explanatory Note. | — | — | — | 9,000 | |
| — | 1.00 | — | — | ||
| Supply installation testing and commissioning of 12 way double door DB As per Explanatory Note. | — | — | — | 1,794.6 | |
| — | 1.00 | — | — | ||
| Supply & Fixing of 63 Amp TPN MCB with complete wiring and connection in existing MCB Box. Make Indoasian, Havelles, L&T, Legrand As per Explanatory Note. | — | — | — | 1,032 | |
| — | 1.00 | — | — | ||
| Supply & Fixing of SPN 32 Amp.MCB In existing MCB Box.Make Indoasian, Havelles, L&T, Legrand. As per Explanatory Note. | — | — | — | 150 | |
| — | 6.00 | — | — | ||
| Supply & Fixing of SPN 16Amp.MCB In existing MCB Box.Make Indoasian, Havelles, L&T, Legrand. As per Explanatory Note. | — | — | — | 900 | |
| — | 500.00 | — | — | ||
| Supply, Laying & fixing o f XLPE insulated PVC outer Sheathed aluminum conductor armoured cable Size 4x25Sqmm suitable for working voltage upto and including 1100 volts conforming to IS: 7098Part-1 )-1988. With amendment number 1&2 &3 reaffirmed 2005.As per Explanatory Note. | — | — | — | 99,700 | |
| — | 4.00 | — | — | ||
| Supplying & making cable End termination of 4x25Sq.mm Aluminium Armoured PVC/XLPE cable. all material required including double compression brass gland , nuts, bolts, PVC tape crimping lugs etc. complete as required for following sizes of aluminum conductor cables. Make as mentioned only. As per Explanatory Note. | — | — | — | 440 | |
| — | 100.00 | — | — | ||
| Supply, wiring, testing and commissioning of light points with 2x4sq.mm multi stranded copper conductor, conforming to IS -694-1990, with 1sqmm green multi stranded copper wire as earth). As per Explanatory Note. | — | — | — | 12,000 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of 16 m motorized high mast system including foundation with its accessories as per specification and approved make As per Explanatory Note. | — | — | — | 1,98,418 | |
| — | 18.00 | — | — | ||
| Supply, erection, testing and commissioning of whether proof LED flood light 190/200W luminaries complete IP rating 65 system efficiency (IM/W) 100 colour temperature (K) 5700, CRI 70, housing LM6M high pressure die cast aluminum covered glass mounting wall/bracket: make Phillips, crompton, havells As per Explanatory Note. | — | — | — | 1,15,200 | |
| — | 1.00 | — | — | ||
| Supply, installation, commissioning of floor mounted outdoor feeder post for high mast SDB As per Explanatory Note. | — | — | — | 18,634 | |
| — | 2.00 | — | — | ||
| Supply, testing and commissioning of earthing station with 600 x 600 x 6 mm thick GI plate earth electrode as per IS : 3043-1987, by breaking of RCC floor, to achieve resistance less than 2 ohm in ground As per Explanatory Note. | — | — | — | 19,940 | |
| — | 500.00 | — | — | ||
| Supply & Laying of 8 SWG GI earth wire with proper thimbling. As per Explanatory Note. | — | — | — | 7,000 | |
| — | 500.00 | — | — | ||
| Excavation and Laying of cable trench under road/RCC/Rly line crossing/Pavement area for laying of cable 1 meter deep and 400 mm wide including repair the same. As per Explanatory Note. | — | — | — | 60,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
rpftender_0001-converted.pdf Tender
ATTACHMENT
rpftender_0001-converted.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .