EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
RMO of Specialized Electrical , Mechanical Services in department of Trade , Taxes, VyaparBhawan,I.P. Estate, New Delhi. (SH-Comprehensive Maintenance of UPS System).
2025_PWD_281881_1
170/EEE/PWDDHC,NDC2025-26
Open Tender
Electrical Works
Works
730 days
New Delhi
Please refer Tender documents.
16 documents required · 16 mandatory
₹0
₹1.4 L
28 Nov 2025
26 Nov 2025
2 Dec 2025
26 Nov 2025
2 Dec 2025
26 Nov 2025
SH-I (RIELLO UPS) Providing comprehensive maintenance of "RIELLO"make, following KVA capacity UPS system consisting of allied equipment’s installed at 1st floor Trade &Tax Building IP Estate New Delhi. (three Phase input & three Phase Out going) including replacement of defective/worn out spare parts such as PCB, IGBT based Diod, Capacitors, relay, cooling fan, indicators, connectors, lugs, wires, switches, fuses, transformer etc.(But excluding batteries) and periodical servicing & preventive maintenance, Routine checking once in a month of the UPS system and attending the break down complaint with in 24 hours after lodging the same and minor repair etc as required, as per terms & condition attached & as per direction of Engineer-in Charge. The scope of work consisting of providing tools and tackles, spares parts, equipments, consumables items required for smooth and uninterrupted working of the complete System etc as required. a) 100 KVA -3 Nos. (1 Job) MATMA45UP470410001,MATMA47UP4728 30003, MAT 47UP472830001 a) 100 KVA UPS For Ist year
b) 100 KVA UPS For IInd year
Supplying and Fixing of following capacity SMF batteries in the existing UPS i/c dismantling and buyback of old batteries, connection, testing and commissioning complete as required. a) 12 V 200 AH (Two Year Warranty)
b) 12 V 18 AH (Two Year Warranty)
Supplying /Installation /Testing and commissioning of 12 V 4.5 AH SMF Batteries in the existing ARD for Lifts i/c dismantling and buyback of old batteries, connection, testing and Commissiong complete i/c One Year Warranty as required.
SH-II (Servo Voltage Stabilizer and Automatic Phase Sequence Corrector) Comprehensive maintenance of following capacity of 3 Phase Servo Voltage Stabilizer of “ELEC” Make installed as per location on monthly basis complete with fortnightly checking, replacement of spare parts/components as per the condition attached including, Servicing, Cleaning, testing, periodical checking(fortnightly) and attending call back service as and when required 40 KVA -9 Nos (1 Job) a) Ist Year
b) IInd Year
Comprehensive maintenance of following capacity of 3 Phase Servo Voltage Stabilizer of “ELEC” Make installed as per location on monthly basis complete with fortnightly checking, replacement of spare parts/components as per the condition attached including, Servicing, Cleaning, testing, periodical checking(fortnightly) and attending call back service as and when required 75 KVA -2 Nos (1 Job) a) Ist Year
b) IInd Year
Comprehensive maintenance of following capacity of 3 Phase Servo Voltage Stabilizer of “ELEC” Make installed as per location on monthly basis complete with fortnightly checking, replacement of spare parts/components as per the condition attached including, Servicing, Cleaning, testing, periodical checking(fortnightly) and attending call back service as and when required 200 KVA -1 Nos (1 Job) a) Ist Year
b) IInd Year
Comprehensive maintenance of following HP Automatic Phase sequence corrector of “ELEC” make installed as per location on monthly basis complete with fortnightly checking, replacement of spare parts/components as per the condition attached including servicing, cleaning, testing, periodical checking (fortnightly) and attending call service as and when required. 40 HP -9 Nos.(1 Job) a) Ist Year
b) IInd Year
Comprehensive maintenance of following HP Automatic Phase sequence corrector of “ELEC” make installed as per location on monthly basis complete with fortnightly checking, replacement of spare parts/components as per the condition attached including servicing, cleaning, testing, periodical checking (fortnightly) and attending call service as and when required. 75 HP -1 Nos.(1 Job) a) Ist Year
b) IInd Year
Comprehensive maintenance of following HP Automatic Phase sequence corrector of “ELEC” make installed as per location on monthly basis complete with fortnightly checking, replacement of spare parts/components as per the condition attached including servicing, cleaning, testing, periodical checking (fortnightly) and attending call service as and when required. 150 HP -1 Nos.(1 Job) a) Ist Year
b) IInd Year
Comprehensive maintenance of following HP Automatic Phase sequence corrector of “ELEC” make installed as per location on monthly basis complete with fortnightly checking, replacement of spare parts/components as per the condition attached including servicing, cleaning, testing, periodical checking (fortnightly) and attending call service as and when required. 215 HP -1 Nos.(1 Job) a) Ist Year
b) IInd Year
Supplying & Filling of Servo transformer Oil for the Existing fill Servo Voltage Stabilizer installed at Trade & Taxes, Vyapar Bhawan, I.P.Estate, New Delhi etc. as reqd.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.24 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.07 MB
BOQ_372431.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .