Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.5 LAccepted-AOC COLLEGE CHOWMUHANI JIRANIA WEST TRIPURA | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹72.2 L+₹3.7 L (5.46%)Rejected-AOC JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L2 | Rejected-AOC 2nd Lowest | |
| 3 | L3₹73.7 L+₹5.2 L (7.60%)Rejected-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L3 | Rejected-AOC 3rd Lowest | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical JATANBARI KARBOK GOMATI TRIPURA | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹86.8 L
EMD Value
₹1.7 L
Closing Date
30 Sept 2021, 5:00 pmClosed
Dy. GM, ED-II
Office of the AGM, ED-II, Bordowali,Agartala
Refer to NIT
2021_POWER_22504_1
DGM/ED-II/TSECL/2021-22/05
Open Tender
Electrical Works
Works
180 days
ESD-III, Bordowali
Refer to Bid documents
6 documents required · 6 mandatory
₹2,000
₹1.7 L
EC-I, Agartala
27 Jan 2022
4 Sept 2021
1 Oct 2021
4 Sept 2021
30 Sept 2021
18 Sept 2021
4 Sept 2021 - 15 Sept 2021
18 Sept 2021
Amount
Supply
Design, Engineering, manufacturing, handling, transportation, insurance and supply of 9.0Mtr Long Steel Tubelar Pole conforming to ISS:2713(P-I&II)/1980 as amended up-to-date and other relevant IS with up-to-date amendments with base plate and as per technical specification of bid documents.
0.30Mtr. Long Cross-arm (made of 75x40x40x6mm Channel)
1.20Mtr. Long Cross-arm (made of 75x40x40x6mm Channel)
2.80Mtr. Long Cross-arm (made of 75x40x40x6mm Channel)
Supply of Polymer Pin Insulator of 45kN, 11KV, suitable for 3 Phase, 50 Hz effectively earthed 11KV Overhead Line.
Design, Engineering, manufacturing, handling, transportation, insurance and supply of outdoor type Triple pole (3 phase), 12 KV, 600 Amp. Manually gang operated, air brake switch, 3 post vertical type shall confirming IS: 9920/1981 (part-I to IV), IS: 2633 & IS: 2544/1973 with latest amendment if any
Supply of 9KV, 5KA single pole, metal oxide gapless surge type Polymeric LA suitable for nominal system voltage of 11kv, 3-phase, 50hz AC supply, creepage distance 600mm, conforming to ISS:3070/1985.
Supply of ACSR Conductor(6/1/2.59mm dia)
Supply of 8SWG, GI Wire, 8SWG
Supply of perforated heavy duty, 40mm dia, 2.5Mtr Long GI Pipe
Supply of 60Kg Salt & 55Kg Charcoal ( For 1 Pit).
Supply of MS Clamp for Cross-arm, made of 50X6 mm MS Flat
Supply of Machine made MS Nut & Bolts (Assorted Size) as per work requirement.
Supply & fixing of Lugs, 120sqmm
Design, Engineering, manufacturing, handling, transportation, insurance and supply of 3 Phase, 3-core, 120 Sq.mm. XLPE insulation screened Aluminium Conductor Power Cable for 11 KV UG line as per IS 7098/II/1985 and latest amendments
Design, Engineering, manufacturing, handling, transportation, insurance and supply of 110 mm outer diameter HDPE pipe (PE- 100 grade) of working pressure 6 kgf/ sq.cm. having minimum wall thickness 6.5 to 7.3 mm. (PN-8, SDR-17)
Design, Engineering, manufacturing, handling, transportation, insurance and supply of 100 mm dia best quality heavy duty GI Pipe as per ISS 1239 of different length as per requirement of engineering.
Erection
Erection of 7.0mtrs,8mtrs & 9mtrs length of Steel Tubular POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Erection of M.S.Channel Cross-Arm,0.3 to 1.2 Mtr. Long75 x40 x 40 x 6 mm (Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 1.3 to 2.8 Mtr . Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of 11 KV Pin insulator along with Pin.
Laying & Stringing of 1 KM (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including hoisting & binding etc. Complete as required.
Erection of 9KV,5KA single pole metal oxide gapless type LA , including necessary connection complete as per technical specification
Erection of 11 KV 400 Amp. GOS unit set of three nos. including necessary connection complete asper technical specification.(Excluding the cost of back clamp.Nuts & Bolts)
Earthing with G. I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (excluding supply of G.l.Pipe, Salt & Charcoal, Gi wire, nuts &bolts, etc. as required)
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode
Febrication of Cross-Arms by MS Channel/MS Angle as per specification
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Trench Size: Width-350mm, Hieght-1200mm Sand(couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks Upto 120 sq. mm
Manually digging /drilling horizontally or diagonali direction for road crossing I Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI pipe direct into the earth at a depth of minimum 11OOmm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering ln Charge
HDD digging /drilling horizontally or diagonali direction for road crossing I Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI pipe direct into the earth at a depth of minimum 11OOmm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering ln Charge
Laying of one number PVC insulated and PV sheathed XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of all size in the GI Pipe/HDPE for riser including tieup of Pipe with pole by the help MS Flat Clamp (excluding cost of Clamp and Nut&Bolts) as required Up to 400 sq. mm
Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : Up to 150sqmm
Coiling of excess Single/3core/3~ Core, upto to 400sqmm, HV/MV, XLPE insulated, armoured power Cable direct into earth including excavation of earth upto a depth of 1500mm (Size pit should be 2250mmX2250mm or as per site requirement.) including 1st class brick protection of two layer flat brick soling , 300 mm. Fine sand (Local quary) for cushioning/bed and refilling and ramming the excavated soil as per direction of Engineer in charge.
Providing of Pre-cast cement concretecable identification route marker (1 cement: 2 coarse sand 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1: 3( 1 cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, ELECTRIC POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colourjapan paint. (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 :3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits.
Supply & Laying of 250mm wide and 1 OOmicrons thick(HDDPE/LLDPE) pre-warning Yellow colour tape. The warning tape shall be printed in RED letter (in English as well as Bengali) as "COUTION: TSECL, ELECTRIC POWER CABLE" and to be placed at about 500mm depth from ground level along the cable route.
Gouting of ST pole /Stay set with CC of ratio 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size)complete with excavation , riffiling of earth, ramming along with centering & shuttering as reqd. @ 0.273 Cum per ST pole & 0.119Cum per stay set as per TSECL specification.
KAJAL DAS
ADHIR DEBNATH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .