Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC MISSION HOSPITAL CHOWK KEDARPUR AMBIKAPUR DIST SURGUJA CG 497001 | SURGUJA | CHHATTISGARH | 497001 | L1 | Accepted-AOC TECHNO COMMERCIALLY ACCEPTED BID | |
| 2 | L2₹48.2 L+₹1.0 L (2.22%)Rejected-Finance MISSION ROAD SUNDERGARH SUNDARGARH ODISHA 770001 | SUNDARGARH | ODISHA | 770001 | L2 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 3 | L3₹49.1 L+₹1.9 L (3.99%)Rejected-Finance | L3 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 4 | L4₹55.3 L+₹8.1 L (17.1%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L4 | Rejected-Finance AS PER TC RECOMMENDATION | |
| 5 | L5₹55.7 L+₹8.5 L (18.0%)Rejected-Finance | L5 | Rejected-Finance AS PER TC RECOMMENDATION |
Tender Value
₹60.5 L
EMD Value
₹75,700
Closing Date
23 Feb 2023, 5:00 pmClosed
SO E AND M
OFFICE OF SO E AND M BASUNDHARA AREA MCL
Supply, installation and commissioning of Street Lighting system along embankment road from Bankibahal chowk to Tumlia chowk (2.7Km) at Kulda OCP, Basundhara Area
2023_MCL_270468_1
MCL/GM/BA/EM/e-Proc/2022-23/28 Date- 08/02/2023
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
BASUNDHARA AREA
AS PER NIT
6 documents required · 6 mandatory
₹75,700
25 Apr 2023
8 Feb 2023
24 Feb 2023
8 Feb 2023
23 Feb 2023
9 Feb 2023
9 Feb 2023 - 16 Feb 2023
Amount
Supply of 9mtrs height Hot Dipped Galvanised Octagonal Street lightning pole having bottom 155 mm A/F, Top 70 mm A/F, Top 70mm A/F, HT Plate 3mm, Base plate 260x260x 16mm
Supply of M24X750MM LONG "J" type foundation bolt along with common templates.
Supply of 01mtr long span pipe 40mm NB "B" CLASS DOUBLE ARM Type heavy duty bracket complete with painting with primer and aluminium paint etc as reqd.
Supply of 250 watt LED pole bracket mounted outdoor type,90-240v,cool white,IP66 Protection,street light fittinng.
Supplying and installation of FEEDER PILLAR panel made from 20 gauge thick CR sheet duly painted /powder coated( 600mm length x 600mm breath 600 mm height) complete with wiring the panel with 10sq mm single core copper conductor cable with following switches and others.(1)63A 4 POLE TPN MCB as incomer. (2)100A 4pole TPN busbar arrangement with 50 x 6mm Copper strip 450mm long complete with insulator nut bolt etc as reqd, (3)Reputed make analog time switch, coil voltage 240V (4) Reputed make 40A 4 POLE NO/NC CONTACTOR (5)Indication lamp R Y B (6) 03NOS 100A isolator as outgoing.
Supplying of 3core1.5sqmm flexible sheathed FRLS copper cable ISI MARK from junctio box to light fitting.
Supplying of 1.1 KV AYFY 4X16 SQMM AL armoured cable with 1100V grade conductivity, annealed stranded aluminium conductor XLPE insulated cores color coated laid up PVC tape inner sheathed and G.I Strip armoured and overall type ST-1 PVC sheathed cable as per IS:7098 PART -1
Supplying of 1.1 KV AYFY 4X50 SQMM AL armoured cable with 1100V grade conductivity, annealed stranded aluminium conductor XLPE insulated cores color coated laid up PVC tape inner sheathed and G.I Strip armoured and overall type ST-1 PVC sheathed cable as per IS:7098 PART -1
Supply of GI pipe 100mm DIA thickness B class ISI MARK (required for road crossing of main cable)
FOR ERECTION AND GROUTING OF POLE) Supply of all materials, labour,T&P and transportation and erection of pole for providing (1)Earth work -0.50x0.50x1.5M SQMT (2)R.C.C -.0.50X0.50X1.5 SQMT (3)Centring and shuttering 4sidex(1.5x0.5),(4) Steel reinforcement structure -vertical with 10mm rod 20x1.5mt and horizontal ring with 8mm rod 7x1.80 mt (5) Holding down bolt 24mm 4x0.85mtrs (6)50x50x6mm MS angle 4nos x0.5mtrs etc complete with centring and shuttering , rod binding,refilling curing as required.(Holding bolt should be Galvanised Iron) as per direction of EIC
Erection of feedeer pillar with stand mounting arrangement from ground along with complete of fencing as per direction of EIC. (The stand should be 01mt height,0.60x0.60 mt length and breadth of 40*40*6mm steel angle iron painting and grouting etc as reqd)
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1kV grade of following size in the existing RCC/ HUMEI METAL pipe as required
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1kV grade of size 4x16 sqmm through HDPE PIPE direct in ground including excavation, sand cushioning,protective covering(Upto 35 35mm) etc as reqd. 50mm,PE 63 HDPE pipes will be supplied by the contractor)
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1kV grade of size 4x50 sqmm through HDPE PIPE direct in ground including excavation, sand cushioning,protective covering (up to 90mm)etc as reqd. 90 mm , PE 100 HDPE pipes will be supplied by the contractor)
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry 'enclosure with cover plate having locking arrangement andwatering pipe of 2.7 meter long( withsuply ang eretion of 25x5 mm GI strip 25 mtr in each earthing) etc. with charcoal/ coke and salt as required. Details of cost for one Set
Supplying and laying 6 SWG G.l. wire at 0.50 meter below ground level for conductorearth electrode, including connection/ termination with Gl thimble etc. as required.Details of cost for 30 Metres
Fixing of LED light fitting 250W , 230V on the 9 Mtr long, Octagonal Pole
Total impact of GST for the purpose of CTC
M/S RAYELEC
DS Associates
M/S LIGHT PALACE
SHIVASAKTI ENGINEERING AND CONSTRUCTION.
MARUTI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .