Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC 296 N 183 2 JOGEN GANGULY STREET MONIRAMPUR BARRACKPORE DIST 24 PARGANAS N KOLKATA 700 120 W B | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.7 L+₹1.3 L (3.85%)Rejected-Finance | L2 | Rejected-Finance Rejected due to higher rate from L1 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
14 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIRS AND MAINTENANCE OF SUMMER APPLIANCES AND ITS CONNECTED ITEMS AT BARRACKPORE UNDER GE AF BARRACKPORE
2023_MES_596123_4
8444/BKP/AF OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF Barrackpore
Class-D,
Category-c(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹56,000
Yes
29 Sept 2023
19 Aug 2023
16 Sept 2023
19 Aug 2023
14 Sept 2023
26 Aug 2023
Amount
Material and labour for servicing / cleaning to window type Air conditioner 1.5 Ton complete with air blower , cleaning of condenser / evaporator coil Units with Air Blower & then wet servicing of Condenser / Evaporator coil units with washing soda etc, checking of complete wiring , tightening of loose wire connections with proper Lugs / Clips. Proper setting of thermostat & other Electrical / Refrigerant controls, cleaning of air filter , reinstallation & testing for proper functioning / cooling effect complete all as specified and directed.
All as per item No 1.00 here in before but for window type Air Conditioner 1 Ton and -ditto-.
All as per item No 1.00 here in before but for Window type Air Conditioner 2 Ton and -ditto-.
Supply and fix in repair reciprocating / rotary compressor seal unit of suitable capacity/model in the unit properly for 1.5 TR window type AC ISI marked complete all as specified and directed.
All as per item No 4.00 here-in-before but 2 TR and -ditto-.
Supply and fix in repair hermetic type compressor seal unit of suitable capacity/model for 1.5 TR window type AC ISI marked complete all as specified and directed.
All as per item No 6.00 here-in-before but 2 TR and -ditto-.
Supply and fix in repair suitable capacity/model condensing coil unit copper for window type AC 1.00 Ton capacity ISI marked complete all as specified and directed.
All as per item No 8.00 here-in-before but 1.5 Ton and -ditto-.
All as per item No 8.00 here-in-before but 2.00 Ton and -ditto-.
Supply and fix in repair blower motor including fan blade, capacitor complete suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacity 1/8 HP, 220 Volts, complete single phase, ISI marked all as specified and directed.
Supply and fix in repair copper cooling coil unit for window type AC of any type ISI marked complete all as specified and directed.
Supply and fix in repair starting capacitor 80/100 Mfd 230 V AC for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair running capacitor 36/45/50 MFD 230 V for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair overload protection coil 230 Volts for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair Relay suitable for window type AC 1.0 Ton/1.5 Ton/2.0 Ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair potential relay for window type AC 1.0/1.5/2.0 Ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair thermostat suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair capillary tube and strainer for window type AC of 1.0 ton/1.5 ton/2.0 ton capacity complete all as specified and directed.
Supply and fix in repair operation knob for window type AC 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed.
Taking out complete unserviceable wiring for AC window type 1.0 ton/1.5 ton/2.0 ton capacity and rewiring with suitable size multi stranded copper cable including testing, checking etc complete all as specified and directed.
Supply and fix in repair PVC air filter for window type AC of 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair capacitor for blower motor suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair fan blade for blower motor suitable for window type AC 1.0 ton/1.5 ton/2.0 ton capacity complete all as specified and directed.
Supply and fix in repair fan blade for window type AC of any capacity complete all as specified and directed.
Supply and fix in repair front grill for window type AC 1.0 ton/1.5 ton/2.0 ton capacity complete all as specified and directed.
Supply and fix in repair swinging/oscillation motor with louvers as per existing make for window type AC 1.0 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair PCB for control unit for window type AC 1.00 ton / 1.50 ton /2.00 ton capacity as per existing make or ISI marked complete all as specified and directed.
Supply and fix in repair bearing/bush for blower and fan motor of capacity 1.0/1.5/2.0 TR complete all as specified and directed.
Material and labour for servicing of split type Air conditioner 1.5 Ton cleaning of Split type AC indoor / outdoor unit complete with air blower , cleaning of Condenser / Evaporator Coil Units with air Blower & then wet servicing of Condenser Coil Units with washing soda etc, checking of complete wiring , tightening of loose wire connections with proper Lugs / clips. Proper setting of thermostat & other Electrical / Refrigerant controls, cleaning of air filter , reinstallation & testing for proper functioning / cooling effect complete all as specified and directed.
All as per item No 30.00 here in before but for Split type Air Conditioner 2.0 Ton and -ditto-.
All as per item No 30.00 here in before but for Split type Air Conditioner 1.0 Ton and -ditto-.
Supply and fix in repair new compressor seal unit of suitable capacity/model in the unit properly for 1.0 Ton split type AC ISI marked complete all as specified and directed.
All as per item No 33.00 here-in-before but 1.5 Ton and -ditto-.
All as per item No 33.00 here-in-before but 2 Ton and -ditto-.
Supply and fix in repair condensing coil unit for split type AC 1.0 Ton capacity all as specified and directed.
All as per item No 36.00 here-in-before but 1.5 Ton and -ditto-.
All as per item No 36.00 here-in-before but 2 Ton and -ditto-.
Supply and fix in repair capillary tube and strainer for split AC of 1.00 ton/1.5 ton/2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair evaporator cooling coil unit for split type AC of any type ISI marked complete all as specified and directed.
Supply and fix in repair starting capacitor 80/100 Mfd 230 Volts AC for split type AC 1.0 / 1.5 / 2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair running capacitor 36/45/50 Mfd 230 Volts for split type AC 1.0 / 1.5 / 2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair overload protection coil 230 Volts AC for split type AC 1.0 / 1.5 / 2.0 ton capacities ISI marked complete all as specified and directed.
Supply and fix in repair relay suitable for split type AC 1.0 / 1.5 / 2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair copper pipe 5/8" / 1/2" / 3/8" / 1/4" dia (as per existing one) for connection to indoor and out door unit, ISI marked complete all as specified and directed.
Supply and fix in repair PVC insulated PVC sheathed 1.5 Sqmm, 3 core copper cable 1100 Volts complete all as specified and directed.
Supply and fix in repair PVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts complete all as specified and directed.
Supply and fix in repair PVC insulated PVC sheathed 4.0 Sqmm, 3 core copper cable 1100 Volts complete all as specified and directed.
Supply and fix in repair swinging motor with louvers as per existing, ISI marked complete all as specified and directed.
Supply and fix in repair blower motor including fan blade, capacitor complete (indoor unit/out door unit) for split type AC 1.5 ton / 2.0 ton capacity 220 volts, single phase ISI marked complete all as specified and directed.
Supply and fix in repair fan blade for blower motor suitable for split AC 1.5 ton / 2.0 ton capacity complete all as specified and directed.
Supply and fix in repair fan blade for outdoor unit of split type AC of any capacity complete all as specified and directed.
Supply and fix in repair LCD / LED display unit for split type AC 1.5 / 2.0 ton capacity ISI marked complete all as specified and directed.
Supply and fix in repair PVC air filter for AC split type 1.5 / 2.0 ton capacity complete all as specified and directed.
Supply and fix in repair PCB for control unit for split type AC 1.5 / 2.0 ton capacity as per existing make of ISI marked complete all as specified and directed.
Supply and fix in repair PCB for control unit for inverter split type AC 1.5 / 2.0 ton capacity as per existing make of ISI marked complete all as specified and directed.
Supply and fix in repair bearing/bush for blower and fan motor of capacity 1.0/1.5/2.0 Ton complete all as specified and directed.
Material and labour for dismantling of storage type water cooler of 80ltr capacity in various location, shifting to MES Yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet by welding/brazing with suitable new sheet metal) by spraying enamel paint and marking/sticking a sticker mentioning the MES No and reassembling, testing, checking and shifted to existing location, fixing the same by nut, bolt, angle iron structure and masonry work complete all as specified directed. NOTE: The spare parts shall be measured & paid separately as supply only rates under respective items. Rates for fixing of spares parts under relevant item shall be included in this item.
Supply only compressor sealed unit of existing model in the unit properly for storage type water cooler of 80 ltr capacity ISI marked complete all as specified and directed.
Supply only blower motor including fan blade, capacitor complete suitable for 80 ltrs capacity, 220 volts, single phase ISI marked complete all as specified and directed.
Material and labour for servicing of water cooler, cleaning of water cooler 40/80 Ltrs complete with blower, cleaning of condenser coil by blower and the wet servicing of condenser of coil with washing soda etc. Checking of complete wiring , tightening of loose wire connections with proper Lugs / clips. Renewal of defective wiring and connector terminal , proper setting of the thermostat and other electrical / Refrigerant controls and refixing the water cooler at place & testing for proper functioning / cooling effect complete all as specified and directed.
Supply and fix in repair capillary tube and strainer for storage type water cooler of any capacity ISI marked complete all as specified and directed.
Supply and fix in repair overload protection coil 230 volts for water cooler of any capacity ISI marked complete all as specified and directed.
Supply and fix in repair relay suitable for water cooler of any capacity ISI marked complete all as specified and directed.
Supply and fix in repair thermostat suitable for water cooler of any capacity ISI marked complete all as specified and directed.
Supply and fix in repair running capacitor 40/50/60 Mfd suitable for water cooler of capacity 80/150 ltrs ISI marked complete all as specified and directed.
Supply and fix in repair starting capacitor 80/100 Mfd 230 volts AC for water cooler capacity 80 / 150 ltrs ISI marked complete all as specified and directed.
Supply and fix in repair capacitor 4/6/10 Mfd 230 volts, single phase AC for blower motor of water cooler ISI marked complete all as specified and directed.
Supply and fix in repair push type water tap made of CP brass suitable for water cooler capacity 80/150 ltrs capacity complete all as specified and directed.
Supply and fix in repair 600 mm long PVC connector complete all as specified and directed.
Supply and fix in repair CP angular stop cock,15mm dia, with wall flange complete all as specified and directed.
Supply and fix in repair CP bib cock, 15mm dia, with wall flange complete all as specified and directed.
Supply and fix in repair fan blade for water cooler of any capacity complete all as specified and directed.
Taking down complete unserviceable internal wiring of, water cooler, refrigerator of any capacity and rewiring the same with 2.5 Sqmm size multi stranded copper cable including testing checking etc complete all as specified and directed.
Supply and fix in repair drain tray made out of stainless steel for water cooler of any capacity complete all as specified and directed.
Supply and fix in repair head cover gasket for water cooler of any capacity complete all as specified and directed.
Supply and fix in repair drain pipe /water pipe flexible type 20 mm of dia for water cooler/Split/Winwod type AC of any capacity complete all as specified and directed.
Material and labour for dismantling of storage type refrigerator upto 390 ltr capacity in various location, shifting it to MES yard for repair/replacement of unserviceable spares and painting the outer body (including replacement of corroded sheet by welding/brazing with suitable new sheet metal) by spraying enamel paint and marking/sticker mentioning the MES No, reassembling, testing, checking and shifted to existing location including masonry work complete all as specified and directed. NOTE: The spare parts shall be measured and paid separately as supply only rate under respective items. Rates for fixing of spare parts shall deemed to be included in this item.
Supply only compressor seal unit of upto 198 ltr capacity / model in the unit properly for domestic refrigerator of any type ISI marked complete all as specified and directed.
Supply only compressor seal unit of 199 to 390 ltr capacity / model in the unit properly for domestic refrigerator of any type ISI marked complete all as specified and directed.
Suplly and fix in repair capillary tube and stainer for any type and capacity of domestic refrigerator ISI marked complete all as specified and directed.
Suplly and fix in repair cooling coil unit for domestic refrigerator of any type ISI marked complete all as specified and directed.
Suplly and fix in repair timer of existing type for domestic refrigerator ISI marked complete all as specified and directed.
Suplly and fix in repair relay for domestic refrigerator of any type complete all as specified and directed.
Suplly and fix in repair thermostat for domestic refrigerator of any type ISI marked complete all as specified and directed.
Taking out complete unserviceable wiring for domestic refrigerator upto 390 ltr capacity and rewiring with suitable size multi stranded copper cable including testing , checking etc complete all as specified and directed.
Material and labour for repair / servicing / overhauling of deep freezer 200 to 450 ltr capacity including cleaning of freezing chamber, chemical wash of packed condenser coil unit and cooling coil, befiting of solenoid switches and relays, replacing of condenser coil, cooling coil, compressor sealed unit, repaing of wiring, dismantling and assembling of chiller box complete all as specified and directed. NOTE: The spare parts shall be measured and paid separately as supply only rates under respective items. Rate for fixing of spare parts under relevant item shall be included in this item.
Supply only copper compressor sealed unit suitable for 220 ltr deep freezer complete all as specified and directed.
Supply only copper compressor sealed unit suitable for 450 ltr deep freezer complete all as specified and directed.
Supply only copper condenser coil suitable for 220 ltr deep freezer complete all as specified and directed.
Supply only copper condenser coil suitable for 450 ltr deep freezer complete all as specified and directed.
Suplly and fix in repair CP angular valve of size 1/2" suitable for split type AC complete all as specified and directed.
Suplly and fix in repair CP angular valve of size ¼" suitable for split type AC complete all as specified and directed.
Suplly and fix in repair CP angular valve of size 5/8" suitable for split type AC complete all as specified and directed.
Supply and fix in repair single pole and neutral (DP) enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V, 20 Amps "C" series complete all as specified and directed. Make:- LEGRAND Cat No 5078 11 or equivalent model of SCHNEIDER / SEIMENS / HAGER / L&T.
Supply and fix Remote control for window type AC of Samsung make of 1.0 TR/1.5 TR/2 TR complete all as specified and directed.
Supply and Fix Remote control for split type AC of LG make of 1.0TR/1.5 TR/2 TR complete all as specified and directed.
Removing the unserviceable voltage stablizer of 1KVA capacity, 1 Phase, 230V, 50Hz from position , open the outer covers, remove the burntout windings from the transformer , rewinding the superanamaled copper windings wire , insulate properly , setting/ testing of buck / boost relay, assemble back & fixing in its original position including testing for proper functioning complete all as specified and directed.
All as per item No 98.00 here-in-before but 2KVA capacity, 1 Phase, 230V, 50Hz and -ditto-.
All as per item No 98.00 here-in-before but 5KVA capacity, 1 Phase, 230V, 50Hz and -ditto-.
Repair / maintenance of voltage stablizer of 1 to 5 KVA capacity from its position, open the outer covers, overhauling the complete unit by cleaning & replacement of minor spares such as fuse, diodes, carbon bushes, internal electric wiring and electronic accessories complete all as specified and directed. Note: Spares such as Voltmeter, Ammeter, MCB, toggle switch, PCB board and relays shall be measured and paid seperately under respective items as supply only.
Supply only voltmeter single phase up to 250 Volt range complete all as specified and directed.
Supply only Ammeter single phase upto 40 Amps range complete all as specified and directed.
Supply only over load protection relay for capacity 1KVA to 5KVA voltage stablizer complete all as specified and directed.
Supply only PCB for capacity 1KVA to 5KVA voltage stablizer complete all as specified and directed.
Supply only switch knob for up & down for capacity 1KVA to 5KVA voltage stablizer complete all as specified and directed.
Material and labour for shifting of serviceable window type AC of any capacity from one location to another location complete all as specified and directed. Note : Cost for spares such as fast nut and stand shall be included in quoted rates.
Material and labour for shifting of serviceable split type AC of any capacity from one location to another location complete all as specified and directed. Note : Cost for spares such as fast nut and stand shall be included in quoted rates.
Supply and fix in repair split AC mounting bracket stand uitable for 1./1.5/2.0 Ton AC complete all as specified and directed.
Material and labour for repair to PCB control unit of window type AC 1.0/1.5/2.0 TR duly servicing and replacing integrated circuit and other devices and refixing the same complete all as specified and directed
Material and labour for repair to PCB control unit of split type AC 1.0/1.5/2.0 TR duly servicing and replacing integrated circuit and other devices and refixing the same complete all as specified and directed
Material and labour for providing black foam insulation of adequate thickness over copper tubing of any size complete all as specified and directed.
Supply and fix in repair single stage high pressure vaccum pump of capacity 50 ltr/min with aluminium alloy casting, oil grain plug with a bottle of vaccum oil complete all as specified and directed.
Supply and fix in repair water proof AC washer high pressure machine having 130 PSI pressure, 230V with adjustable spray level for rinse and wash, wear resistive and rust proof metal handle complete all as specified and directed.
Labour only for charging refrigerant gas M-22/R-22/R-138/R-32/R-410A/134A/HYDRO CARBON in the system of window type AC/ split AC/ water cooler/ domestic refrigerator of any capacity / size complete all as specified and directed. Note : The refrigerant gas M-22/R-22 /R-32/R-410A / 134A/HYDRO CARBON shall be measured and paid separately as ‘supply gas only’ under respective items.
Supply only refrigerant gas M-22/R-22/R-32/R-410A complete all as specified and directed.
Supply only refrigerant gas 134A complete all as specified and directed.
Supply only refrigerant gas HYDRO CARBON complete all as specified and directed.
Supply only LPG cane gas of 900 ml capacity for welding and brazing including welding stick of condensing coil unit complete all as specified and as directed.
CHANDRA CONSTRUCTION AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .