Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC 4 28 VIVEK NAGAR KOLKATA 700075 | KOLKATA | KOLKATA | WEST BENGAL | 700075 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.2 L+₹4,040 (0.97%)Rejected-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L2 | Rejected-Finance L2 | |
| 3 | L3₹4.4 L+₹25,443 (6.11%)Rejected-Finance 51 1A NILKANTHA CHATTERJEE STREET BELGHARIA KOLKATA 700056 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700056 | L3 | Rejected-Finance L3 | |
| 4 | L4₹4.6 L+₹42,310 (10.2%)Rejected-Finance 28 A CHANDRA MASTER ROAD BARRACKPORE NORTH 24 PARGANAS WEST BENGAL 700122 | BARRACKPORE | NORTH 24 PARGANAS | WEST BENGAL | 700122 | L4 | Rejected-Finance L4 | |
| 5 | L5₹4.7 L+₹49,588 (11.9%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹10,950
Closing Date
12 Dec 2020, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
O/o The EE_KNED, PWDte, P-5, CIT Road, 2nd Floor, Moulali,Kolkata-700 014.
Proposed construction of building (Block-E) in the Campus of Hiralal Mazumdar Memorial College for Women at Dakshineswar------E.I. Works.
2020_WBPWD_307231_1
WBPWD/EE/KNED/NIT-21 of 2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Hiralal Mazumdar Memorial College for Women.
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,950
19 Jan 2021
2 Dec 2020
14 Dec 2020
6 Dec 2020
12 Dec 2020
6 Dec 2020
120 days
Amount
SITC of indoor type cubical panel box fabricated from 3mm thick sheet with standing top portion of size 900(H) X 1200(W) X400 (D) mm with 4nos angle iron leg with single locking arrangement with lock & keys, air vent on side face comprising of thefollowing electrical equipments and making necy. connection and painting by phosphatised powder coated paint as per direction of EIC. The box should be comprising of the following accessories: INCOMING : - 1) S&F 415V, 315 A TPN SFU ---1 no. as incoming 2) S& F 315 A Fuse Link --- 3 nos 3) S&F R,Y,B Indication lamp ----3 nos 4) S&F 6A SP 10KA Control MCB ---- 3 nos 5) S&F Neutral Link ---- 1 nos OUTGOING : - 1) S&F 415 V, 100 A TPN SFU --- 1 nos 2) S&F 100 A Fuse Link ----- 3nos 3) S&F Indication lamp -----3 nos 4) S&F Neutral Link ----- 1 nos 1) S&F 415 V, 160 A TPN SFU --- 2 nos 2) S&F 160 A Fuse Link ----- 6nos 3) S&F Indication lamp -----6 nos 4) S&F Neutral Link ----- 2 nos
BUSBAR ARRANGEMENT : - 1) S&F 415V, 315A ,Copper busbar Chamber 40x6 (for Phase & neutral)-1no 2) S&F 32A, 4P, MCB--1no 3) S &F 315 A measuring ammeter, 415 V measuring voltmeter with necy. arrengement 4) S&F RYB indication lamp --- 3 nos The complete arrangement must be wired by suitable size PVC insulated Cu wire with suitable sockets/lugs.7 with suitable arrangement) Cable Alley:- Cable alley will be side of outgoing main switch. Each dimension- 900mm(H)x200 mm(W)x 400 mm (D)---1 nos. Allocation- Under the stair case of "E" building. (Make- L&T/ Havells/ Standard/SIEMENS)
Supplying and fixing double door Vertical 4 way 415V, 160A VTPN DB with MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING-Supplying and fixing 415 V,160A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection.....1 nos. OUTGOING-Supplying and fixing 415 V,40A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection......4 nos (Make- Legrand/Havels/L&T) For light load.
Supplying and fixing 6 way 415V, 40 A double door HTPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING-Supplying and fixing four pole 415 V, 40A MCB Isolator on din rail of existing DBs and necessary connection......1 nos. SP. OUTGOING- Supplying and fixing 240V,6-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection......18 nos (Make- Legrand/Havels/L&T) For light load.
Supplying and fixing (2+8 Way) double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMEING-Supplying and fixing 240V, 40A DP MCB Isolator on din rail of existing DBs and necessary connection......1 nos. OUTGOING- Supplying and fixing 240 V, 6-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.........8 nos (Make- Legrand/Havels/L&T)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish.2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. Avarage Run-9 mtrs
Do-Do-Do……. ON Board
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Supply & Fixing 240 V, (6A+6A) Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, (16 A+6A) Modular type plug socket (Brand approved by EIC) with 16A Modular type switch and 6A Modular type Switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying & Fixing 240V,2 nos 6A 5 pin modular type plug socket with 2 nos 6A modular type switch(Brand approve by EIC),1 nos 15A,3pin modular type plug socket with -1 nos, 15 A modular type switch. With 1 nos 32A SP MCB (C curve) and indicator without plug top on 2 row 12 module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connection PVC cu wire and earth continuty wire etc.(Computer Board)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), with plug top(with indicator) and switch, on existing GI Modular type switch board and making necy. connections with PVC Cu wire and earth continuity wire etc.( For AC connection)
Supply and Laying 4 core 185 sqmm cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish at an average depth of 100 mm in floor/pavement/wall etc. Allocation:- CESC to Panel (Make-Havels/ KEI/Mescab/Plaza)
Supply and laying of 4 core 185 sqmm cable in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables and Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
(i) For 4 core 185 sqmm cable
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC (For power plug)
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC (For AC)
3x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC (For VTPNDB to HTPNDB)
3x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC (For panel to VTPNDB)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
Do-do-do---For---10.0 sqmm copper wire
Do-do-do---For---6.0 sqmm copper wire
Do-do-do---For---4.0 sqmm copper wire
Do-do-do---For---2.5 sqmm copper wire
Do-do-do---For---1.5 sqmm copper wire
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)
(i) 19mm dia 3mm thick Polythene Pipe
(ii) 25mm dia 3mm thick Polythene Pipe
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
(i) 19mm dia 3mm thick Polythene Pipe
(ii) 25mm dia 3mm thick Polythene Pipe
Supply and Fixing ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint with RC fan clamp making necessary connection as required by 2x1.5 sqmm flexible copper wire. 1200 mm sweep high speed celing fan Allocation- For class room. (Make- Crompton/ Orient/ Havells/Usha)
Supply and Fixing of Double LED light fitting with S & F 2 no. 18W LED tube of Aluminium Heat Sink body with inbuild driver and necessary accessories, suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. (Make- Surya/Philips/Crompton/Havells)
Excavation of soil for installation of Earth Electrode and filling & ramming. (i) For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. (By ISI-Medium GI pipe/TATA)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. (i) No. 4 SWG
Prava Enterprise
M/S T AND D ENGINEERING WORKS
M/S SEN ELECTRICAL WORKS
Electromech Engineers Co-Operative Society Ltd.
NEW INDIA ELECTRICAL AND ENGINEERING WORKS
stage.html
html • 0.06 MB
technical_576376.pdf
PDF • 0.56 MB
techsummary_576376.pdf
PDF • 0.56 MB
finance_576376.pdf
PDF • 0.56 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_576376.pdf
PDF • 0.42 MB
NIT_21_DB_ENTERPRISE.pdf
PDF • 0.41 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .