| 1.00Jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of MSERW pipe of following dia meters confirming to BIS 3183-2007, steel grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). | ||||||
| 1.01 | 250 mm dia MSERW pipe at various RDs | 22 | Joint | 1,920 ₹42,240 | 2,000 ₹44,000 | 2,100 ₹46,200 |
| 2.00Providing and refixing cast Iron Gate sluice valve (Flanaged) Confirming to IS 14846:2000 | ||||||
| 2.01 | 50 mm dia | 3 | Each | 17,500 ₹52,500 | 18,000 ₹54,000 | 18,500 ₹55,500 |
| 2.02 | 50 mm dia | 3 | Each | 21,300 ₹63,900 | 22,000 ₹66,000 | 23,000 ₹69,000 |
Tender Value
₹1.4 L
EMD Value
₹2,838
Closing Date
2 Jul 2026, 5:00 pmClosed
Executive Engineer
JS Division Dharampur Bharari
Restoration of rain damages to LWSS Tourkhola and multi villages in Sandhole Distt Mandi HP SH Jointing of rising main at various points 250 mm
2026_HPIPH_137326_1
3569-3618 Dated 23-06-2026
Open Tender
Civil Works
30 days
Dharampur
Please refer Tender documents.
7 documents required · 7 mandatory
₹350
Executive Engineer
₹2,838
10 Jul 2026
23 Jun 2026
3 Jul 2026
23 Jun 2026
2 Jul 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of MSERW pipe of following dia meters confirming to BIS 3183-2007, steel grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately). | |||||
| 1.01 | 250 mm dia MSERW pipe at various RDs | 22 | Joint | 100 | ₹2,200 |
| 2Providing and refixing cast Iron Gate sluice valve (Flanaged) Confirming to IS 14846:2000 | |||||
| 2.01 | 50 mm dia | 3 | Each | 100 | ₹300 |
| 2.02 | 50 mm dia | 3 | Each | 100 | ₹300 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Form6.pdf
Tender Documents • 0.79 MB
Form8.pdf
Tender Documents • 1.28 MB
BOQ_203235.xls
BOQ • 0.27 MB
TC.pdf
Tender Documents • 0.16 MB
Download all tender documents and submit your bid