| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAdmitted-Finance | ₹3.9 L | L1 | Admitted-Finance |
| 2 | L2₹3.9 L+₹1,274.62 (0.32%)Admitted-Finance | ₹3.9 L+₹1,274.62 (0.32%) | L2 | Admitted-Finance |
| 3 | L3₹4.0 L+₹3,234 (0.82%)Admitted-Finance | ₹4.0 L+₹3,234 (0.82%) | L3 | Admitted-Finance |
| 4 | L4₹4.0 L+₹3,325 (0.85%)Admitted-Finance | ₹4.0 L+₹3,325 (0.85%) | L4 | Admitted-Finance |
| 5 | L5₹4.0 L+₹4,621.98 (1.18%)Admitted-Finance | ₹4.0 L+₹4,621.98 (1.18%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Anna Traders and Construction L2 | MADINA ENTERPRISES L3 | MS SHRADDHA CONST AND ENGG WORKS L1 | M/s GOURY ENTERPRISES L5 | JAI MATA DI TRADERS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.01 | Supply & installation of submersible pump set suitable for 6” dia bore well running with 3 phase 415 + 10% volts 50 C/s 2900 RPM having discharging capacity 8.5 LPS against total head of 102 meters no of stages 25 with Noryl/G.M impeller complete set. | 1 | P/ set | 50,730.5 ₹50,730.5 | 48,200 ₹48,200 | 48,000 ₹48,000 Lowest | 48,368.7 ₹48,368.7 | 48,205 ₹48,205 |
| 1.02 | Cost towards S/F 2” dia UPVC Column pipe ISI mark or Reputed make | 1 | P/ft. | 54.73 ₹54.73 | 52 ₹52 | 50 ₹50 Lowest | 52.18 ₹52.18 | 53 ₹53 |
| 1.03 | Cost towards flushing of high yield T/W (150 mtrs) through rig machine including all labour tools and tackles. | 1 | P/job | 42,310.5 ₹42,310.5 | 40,200 ₹40,200 | 40,000 ₹40,000 Lowest | 40,340.7 ₹40,340.7 | 40,201 ₹40,201 |
| 1.04 | Supplying triple spur type 3 tonne Capacity chain pulley block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift tested to 50% over load as per IS 332 carrying ISI mark. | 1 | 1 No | 30,259.38 ₹30,259.38 | 28,750 ₹28,750 | 28,500 ₹28,500 Lowest | 28,850.62 ₹28,850.62 | 28,751 ₹28,751 |
| 1.05 | Supply & installation of submersible pump set suitable for 6” dia bore well running with 3 phase 415 + 10% volts 50 C/S 2900 RPM having discharging capacity 3600 GPH against total head of 60 meters with noryl/G.M Impeller consists of following accessories:-
(a) 2 ½” dia G.I column pipe 200’(10’ long both end threaded one end fitted socket and other end covered plastic)
(b) 3 Core flat copper cable 4 mm2 -1 coil
(c) M.S Clamp 2 ½ dia- 2 Pairs
(d) C.I.D.F sluice valve 2 ½” dia- 1 no.
(e) C.I.D.F reflex valve 2 ½” dia- 1 No. | 1 | P/set | 1,32,194 ₹1,32,194 | 1,25,600 ₹1,25,600 | 1,25,000 ₹1,25,000 Lowest | 1,26,039.6 ₹1,26,039.6 | 1,25,605 ₹1,25,605 |
| 1.06 | Cost towards renovation of light wiring in out side pump chamber & inside switch room by doing short point light wiring 4 point long point light wiring 4 points,100 watt street light complete set-36 Watt CFL- 4 Nos. etc all including labour charges all complete. | 1 | P/job | 17,103.13 ₹17,103.13 | 16,250 ₹16,250 | 16,100 ₹16,100 Lowest | 16,306.88 ₹16,306.88 | 16,255 ₹16,255 |
| 1.07 | Supplying & making tripod (14x65 mm C.I pipe) for hanging chain pulley block. | 1 | P/job | 2,526 ₹2,526 Lowest | 24,000 ₹24,000 | 23,800 ₹23,800 | 24,084 ₹24,084 | 24,002 ₹24,002 |
| 1.08 | Cost of repairing of 3 H.P submersible pump by changing and fitting new s.s pump shaft as per sample changing its 3 nos. G.M impeller changing 5 Nos. G.M bush locking key and reassembly its pump all complete. | 1 | P/job | 8,420 ₹8,420 | 8,000 ₹8,000 | 7,900 ₹7,900 Lowest | 8,028 ₹8,028 | 8,001 ₹8,001 |
| 1.09 | Cost towards rewinding of 3 H.P sub. motor (3 phase 415+ 10% volts 50 C/S 2900 RPM) by supplying PVC insulated water proof copper wire as per size required changing and fitting thrust plate-1 No. G.M bearing bushed for top and bottom and fitting rotor into stator after completion of rewinding work testing the motor on load at side all complete. | 1 | P/job | 14,314 ₹14,314 | 13,600 ₹13,600 | 13,500 ₹13,500 Lowest | 13,647.6 ₹13,647.6 | 13,605 ₹13,605 |
| 1.10 | supplying & laying 7/16 copper cable ISI mark. | 1 | P/mtr | 218.92 ₹218.92 | 208 ₹208 | 205 ₹205 Lowest | 208.73 ₹208.73 | 210 ₹210 |
Tender Value
Refer Docs
Closing Date
11 Aug 2026, 2:00 pmClosed
EE, D.W and S. Mechanical Division Jamshedpur
Office of the EE, D.W and S. Mechanical Division Jamshedpur
e-quotations are invited for Annual R M Estimate of Govt. Building water Supply for MGM Campus, Dimna P/P from reputed Manufacturers, Authorized Dealers, Registered departmental contractor having valid G.S.T.I.N for respective items
2026_DWSD_116775_1
e-Quotation No. 02/2026-27
Open Tender
Repair and Maintenance Services
Item Rate
365 days
Jamshedpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
13 Aug 2026
4 Aug 2026
12 Aug 2026
4 Aug 2026
11 Aug 2026
4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply & installation of submersible pump set suitable for 6” dia bore well running with 3 phase 415 + 10% volts 50 C/s 2900 RPM having discharging capacity 8.5 LPS against total head of 102 meters no of stages 25 with Noryl/G.M impeller complete set. | - | P/ set | 1.25 | - |
| 1.02 | Cost towards S/F 2” dia UPVC Column pipe ISI mark or Reputed make | - | P/ft. | 2.25 | - |
| 1.03 | Cost towards flushing of high yield T/W (150 mtrs) through rig machine including all labour tools and tackles. | - | P/job | 3.25 | - |
| 1.04 | Supplying triple spur type 3 tonne Capacity chain pulley block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift tested to 50% over load as per IS 332 carrying ISI mark. | - | 1 No | 4.25 | - |
| 1.05 | Supply & installation of submersible pump set suitable for 6” dia bore well running with 3 phase 415 + 10% volts 50 C/S 2900 RPM having discharging capacity 3600 GPH against total head of 60 meters with noryl/G.M Impeller consists of following accessories:-
(a) 2 ½” dia G.I column pipe 200’(10’ long both end threaded one end fitted socket and other end covered plastic)
(b) 3 Core flat copper cable 4 mm2 -1 coil
(c) M.S Clamp 2 ½ dia- 2 Pairs
(d) C.I.D.F sluice valve 2 ½” dia- 1 no.
(e) C.I.D.F reflex valve 2 ½” dia- 1 No. | - | P/set | 5.25 | - |
| 1.06 | Cost towards renovation of light wiring in out side pump chamber & inside switch room by doing short point light wiring 4 point long point light wiring 4 points,100 watt street light complete set-36 Watt CFL- 4 Nos. etc all including labour charges all complete. | - | P/job | 6.25 | - |
| 1.07 | Supplying & making tripod (14x65 mm C.I pipe) for hanging chain pulley block. | - | P/job | 7.25 | - |
| 1.08 | Cost of repairing of 3 H.P submersible pump by changing and fitting new s.s pump shaft as per sample changing its 3 nos. G.M impeller changing 5 Nos. G.M bush locking key and reassembly its pump all complete. | - | P/job | 8.25 | - |
| 1.09 | Cost towards rewinding of 3 H.P sub. motor (3 phase 415+ 10% volts 50 C/S 2900 RPM) by supplying PVC insulated water proof copper wire as per size required changing and fitting thrust plate-1 No. G.M bearing bushed for top and bottom and fitting rotor into stator after completion of rewinding work testing the motor on load at side all complete. | - | P/job | 9.25 | - |
| 1.1 | supplying & laying 7/16 copper cable ISI mark. | - | P/mtr | 10.25 | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
BOQ2.pdf
Tender Documents • 0.08 MB
BOQ_157884.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .