Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 Cr+₹22,319.88 (0.15%)Admitted-Finance | ₹1.5 Cr+₹22,319.88 (0.15%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Gee Sab Electricals L1 | Bhat Electrical and Mechanical Works L2 |
|---|---|---|---|---|---|
| 1.0033 KV LINE | |||||
| 2.00 | Supply & Erection of 11 Mtr long ST Poles 410 SP-56 complete along with pit excavation and 1/6 th of pole embedded in soil as per relevant REC standards. | 152 | Nos | 37,786 ₹57,43,472 | 36,000 ₹54,72,000 Lowest |
| 3.00 | Providing, Erection and fixing of GI V cross arm with Top bracket including clamps, braces & washers as per relevant Standards | 2,600 | Kg | 200 ₹5,20,000 Lowest | 200 ₹5,20,000 Lowest |
| 4.00 | Providing, Erection and fixing of GI Channel cross arm including clamps, braces & washers as per relevant Standards | 2,640 | Kg | 200 ₹5,28,000 Lowest | 200 ₹5,28,000 Lowest |
| 5.00 | Supply, Laying, Stringing and binding of 0.1 ACSR Conductor with jumpering at tension points as per relevant standards. | 24.72 | km | 1,79,786 ₹44,44,309.92 | 1,67,000 ₹41,28,240 Lowest |
| 6.00 | Heavy duty Pressure di-cast aluminium 630A PG-clamps suitable for 0.1 ACSR Conductor | 60 | Nos | 50 ₹3,000 Lowest | 200 ₹12,000 |
| 7.00 | Providing and fixing of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards | 384 | Nos | 700 ₹2,68,800 | 650 ₹2,49,600 Lowest |
| 8.00 | Providing and fixing of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards complete with suitable tension fittings | 144 | Nos | 900 ₹1,29,600 Lowest | 1,050 ₹1,51,200 |
| 9.00 | Providing and fixing of G.I. Nuts & bolts as per relevant REC standards. | 200 | kg | 200 ₹40,000 Lowest | 200 ₹40,000 Lowest |
| 10.00 | Providing and fitting of danger plates on each pole as per relevant standards | 128 | Nos | 100 ₹12,800 Lowest | 250 ₹32,000 |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
15 Jun 2026, 6:00 pmClosed
EXECUTIVE ENGINEER STD-IV, JPDCL KALAKOTE
OFFICE OF EX. ENGINEER STD-IV, JPDCL KALAKOTE
Supply, Erection Testing, Commissioning of 33 KV line and 33kv Line Bay for newly under construction Receiving station Badhal Gali.
2026_PDD_310163_1
STD-IV/JPDCL/08 of 2026-27
Open Tender
Electrical Works
Turn-key
Kalakote
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
Executive Engineer Sub Transmission Div-iv Kalakot
₹2.9 L
22 Jun 2026
18 May 2026
16 Jun 2026
18 May 2026
15 Jun 2026
18 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 33 KV LINE | - | - | - | - |
| 2 | Supply & Erection of 11 Mtr long ST Poles 410 SP-56 complete along with pit excavation and 1/6 th of pole embedded in soil as per relevant REC standards. | 152 | Nos | - | - |
| 3 | Providing, Erection and fixing of GI V cross arm with Top bracket including clamps, braces & washers as per relevant Standards | 2,600 | Kg | - | - |
| 4 | Providing, Erection and fixing of GI Channel cross arm including clamps, braces & washers as per relevant Standards | 2,640 | Kg | - | - |
| 5 | Supply, Laying, Stringing and binding of 0.1 ACSR Conductor with jumpering at tension points as per relevant standards. | 24.72 | km | - | - |
| 6 | Heavy duty Pressure di-cast aluminium 630A PG-clamps suitable for 0.1 ACSR Conductor | 60 | Nos | - | - |
| 7 | Providing and fixing of 33 kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards | 384 | Nos | - | - |
| 8 | Providing and fixing of 33 kV Polymeric composite Disc Insulator 36KV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm as per relevant Standards complete with suitable tension fittings | 144 | Nos | - | - |
| 9 | Providing and fixing of G.I. Nuts & bolts as per relevant REC standards. | 200 | kg | - | - |
| 10 | Providing and fitting of danger plates on each pole as per relevant standards | 128 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
Tendernotice_2.pdf
PDF • 18.44 MB
Tendernotice_3.pdf
PDF • 1.18 MB
BOQ_1003682.xls
BOQ • 0.23 MB
Date_Extensionsd.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .