| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹10.2 LAccepted-AOC 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L-1 | Accepted-AOC Being L1 bidder | |
| 2 | L-2₹11.4 L+₹1.2 L (12.2%)Rejected-Finance PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L-2 | Rejected-Finance Being L 2 | |
| 3 | L-3₹11.4 L+₹1.3 L (12.4%)Rejected-Finance | L-3 | Rejected-Finance Being L 3 | |
| 4 | L-4₹11.5 L+₹1.3 L (13.0%)Rejected-Finance NEAR KRIPAN TCP GATE PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L-4 | Rejected-Finance Being L 4 | |
| 5 | L-5₹12.1 L+₹1.9 L (18.3%)Rejected-Finance | L-5 | Rejected-Finance Being L 5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
14 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri PIN -735232 (West Bengal)
POVISION OF MODIFICATION OF SHELTER BLDG NO T 11 VI WITH CABIN PARTITION UNDER GE NORTH BINNAGURI
2021_MES_442657_1
8701/01/02/2021-22/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
Binnaguri
As per tender documents
8 documents required · 8 mandatory
₹500
GE North Binnaguri
₹50,000
Yes
26 Jun 2021
13 May 2021
16 Jun 2021
13 May 2021
14 Jun 2021
27 May 2021
60 days
Amount
SCHEDULE A CIVIL WORKS Material and labour for false ceiling with GI powder coated frame work and 4 mm thick E board classic design , non asbesto fibre reinforced cement board , Reinforced Designer Board tiles conforming to IS-14862 and ISO-8336 , of approved texture at all height duly suspended ceiling laid on hot dip galvanised iron imposed grid of size 600 mm x 600 mm, T section / Angle section including cutting holes in brick wall and making good surface with cement concrete 1:2:4 type B-0 / 1:3 cement mortar complete all as specifiedand having following details: (a) 27mm x 27 mm angle 0.55 mm thickness, GI powder coated hot dip galvanised plugged at the rate 600mm centre to centre alongwith the perimeter of wall. (b) 25 mm x 25 mm Tee 0.55 mm thickness, GI powder coated hot dip galvanised as main and cross runner suspended with 1.6 mm dia GI wire suspendrs (not exc. 1.20 mtr length) with adjustable clamps and dash true fastners plugged in RCC slab or angle iron runner of slopped roof placed at the rate 600 mm centre to centre alongwith the perimeter of wall. Note: The work shall be carried out as per manufacturer instruction and as directed.
Roughening surfaces of old concrete floor/ verticle surface by picking, sweeping clean and washing down with water to remove dust etc.and prepare the surface to receive tiles including applying 3Kg/Sqm cement slurry complete all as specified and directed.
Material and labour for Non Skid joint free ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. over and including 15 mm thick screeding in CM 1:6 complete all as specified ( screed bed shall not be measured and paid separately).
Suppy and fixed, powder coated anodised aluminium frame of size 100 mm x 44 mm x 1.50 mm thickness made of Square/tubular coated Aluminium section for door with one or more rebates jointing cleat for fixing etc and provision of aluminium door shutter (Single/Double shutter) including necessary jointing cleats glazing clips, rubber gasket aluminium anodised snap beading, nylon wool pile weather strip , screws, hold fast, Aluminium hinges 3Nos, 200mm long handle for each shutter, floor stopper, locking arrangements handle, 12 mm thicness prelaminated particle fixed in panels with aluminium complete all as directed.
Suppy and fixed, powder coated anodised aluminium sections weighing 0.55kg/m imade of Square/tubular Aluminium section for.partition with one or more rebates jointing cleat for fixing etc and necessary jointing cleats clips, rubber gasket aluminium anodised snap beading, screws, hold fast, 12 mm thicness prelaminated particle fixed in panels with aluminium complete all as directed.
Supply and fixed Steel work in rafters, trusses,purlins, post etc. using steel hollow sections conforming to IS-4923-1997 Grade Yst 310 complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 complete all as specified.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint (1st quality) over one coat of red oxide Zinc chrome primer complete all as specified.
ELECTRIFICATION WORKS Material & Labour for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sundn terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be sone through proper size copper/brass thimbles. Where concealing of conduit is not feasible ie on surface of roof etc, conduit shall be fixed on surface with necessary saddles at no extra cost all as specified and as directed for one light / fan point / exhaust point controlled by one 5 Amps one way switch complete all as specified and as directed for light /fan point controlled by one way switch 5/6 amps. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No 8.00 here-in-before but for socket potlet 5/6 Amps point on independent board complete all as specified & as directed.
Material and labour for point wiring complete for one socket outlet 15 Amps point on independent board with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes upto a size of 200 x 300mm and above this size not less than 1.63 mm thick duly painted with aluminum inside and anticorrosive paint outside, concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
Supply and fixed switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supply and fixed socket outlet 2 in 1 , 5 pin , (5/6 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixed socket outlet 2 in 1 , 5 pin , (6 Amps & 16 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixed switch piano flush type, single pole , 15/16 Amps, one way complete all as specified.
Supply & fixed stepped type electronic fan regulator flush type 120/280 Volts ISI marked complete all as specified .
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply and fixed recessed mounted 2' x 2 ' LED luminaire 34 watts for grid ceiling minimumm lumen output 3300 lumen, pre-treated CRCA frame powder coated with diffused Profied protection IP-65 including necessary connection complete all as specified and directed.
Supply and fixing ceiling fan 1200 mm sweep, 230 volts AC 50 Hz, metal body with BEE 5 STAR rating comforming to IS-374-1979 including necessary connection with prewired 3 core flexible multistrand copper cable complete all as specified.
Supply, installing, commissioing and testing , split type Air Conditioner of capacity 2.0 TR with with hermatically sealed unit complete with dual system i.e. Cooling and with PCB and remote operation on (R-410 A refrigerant ), built in air ioniser and plasma filter for better indoor air quality, electric driven , suitable for working on 230 volts, single phase, 50 Hz supply, (5 STAR Rating invertor type all weather) complete including providing required copper piping, insulation etc, cutting of wall, powder coated steel brackets and making good disturbed surface of wall etc and remote operation complete all as specified and directed .
Supply and fixed 5kVA automatic Voltage stabliser automatic boost / buck transformer for low and high voltage with electronic transistorised relay / time relay for two min, single phase, naturally air cooled, indoor type wall mounted, designed to give output voltage 230V + 2.5% at input range between 170 to 250 Volts complete all as specified.
Supply and fixed epoxy powder coated sheet metal enclosures with socket plug top and MCB , Single pole and neautral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 32 Amps, 240 Volts, 'C' series current carrying capacity 10 KA , including necessary connection complete all as specified and directed.
Supplying and fixing 20 mm nominal bore dia, 3mm wall thickness PVC pipes of pressure rating 10 kgf/sqcm fixed with MS flat iron clamp of size 20 x 3mm at every 1.5 m length of pipe with nuts and bolts fixed to pole /walls, complete all as specified and as directed.
Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 4 sqmm conductor for main and one run of 4 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 2 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
L. B. SHARMA
PRAVESH KUMAR
R K AGARWAL
M/S. JAGDISH PRASAD AGARWALA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .