SITC of 09 Mtr. - Octagonal Poles with 90w (90 Watt IP 66) LED fitting, Cetralized Lighting load Energy Saver System Panel & accessories considering 25 Mtr. Distance between two poles @ Panoli Estate. (Single Side Installation) Two-year maintenance guarantee period.
267326
04/2025-26 TENDER SR. NO.02
Open
Electrical - Lighting and luminaries
Works
Bharuch
1 document required · 0 mandatory · 1 optional
₹4,248
Yes
Chief Officer, Notified Area GIDC, Panoli
₹1.6 L
Yes
20 Jan 2026
20 Jan 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
Name SITC of 09 Mtr. - Octagonal Poles with 90 (90 Watt IP 66) LED fitting, Cetralized Lighting load Energy
Of Saver System Panel & accessories Considering 25 Mtr. Distance between two poles @ Panoli Estate. (Single
Work Side Installation) Two-year maintenance guarantee period.
QTY. DESCRIPTION OF ITEM UNIT RATE/ Total Amount
QTY. DESCRIPTION OF ITEM UNIT RATE/ Total Amount
Supplying and erecting approved make Octagonal pole made from
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
1 388 35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and No. 15705.50
arrangement for cable termination to be erected on suitable
foundation (included). (iii) Add Extra for PU base primer and PU
Paint on pole.-(H) 9 Mtr. Long 70 mm Top X 155 mm bottom dia,
3 mm thickness with 260mmX260mmX16mm base plate, 4-M
Bolts and 750mm long J-Bolt.Approx Pole weight 97 kg
Providing M-150 / 1:2:4 cement concrete foundation & 70 % PCC
from bottom including excavation for the pole of size 60 x 60 x
cms. Deep in below ground level with plinth of 45 cms x 45 cms(or
45 cms dia x 45 cms) high upper ground level with necessary
2 388 curing and finishing in approved manner.( for 9 & 10). Construction No. 1652.36
of RCC Foundation for Octogonal pole suitable for 9 Mtr Hight
pole with J type bolts erection etc complete, foundation design
given by Agency and design by approved structure consultant, and
as per details specification and as per directed by engineer in
Providing & erecting ISI marked Double pole 6 A to 32 A switch
suitable to operate on 240 V, A. C. supply and having overload &
short circuit triping element and breaking capacity 10 kA
conforming to IS: 8828/ 1996 with mounting clamp with nuts, bolts
3 388 & washers suitable for erection on pole with cable clamps & earth No. 326.23
bolt.,for lighting Load (B Curve) in existing box (Cat-III) with
Backelite connector strip 4 way-2 nos/8 way -01 No (incoming &
out going cablewith stud type terminals suitable for 4C X 16 Sq mm
Cable on existing board - (1 No. Per St. Lght Pole)
P & F of Solderless Crimping Type Aluminium Lugs (4 Nos. per
termination) conforming to IS suitable for 1 x 4.0 Core x 16 Sq.
MM PVC Insulated Aluminium Armoured cablewith high pressure
tool &l complete erected with insulating materials for each
termination. - (2 Nos. Termination Per St. Light Pole & 16 nos.
termination per Energy Saver System )
SITC of funnel type pipe earthing having 150 cms Long and
cms dia. Medium Class Galvanised iron pipe with coupling and
buch burried in specially prepared earth pit with salt & charcoal
5 388 complete with necessary double 8 SWG hot deep galvanised iron No. 602.97
strip earth wire - 0.8 Kg (2 x 3.5 Mtr. = 7Mtr.) laid upto bolt fitted
in pole for earthing . (Earthing at each poles) as per drawing - (1 Job
Per St. Light Pole)
SITC of Decorative Single Arm Bracket consisting of Light Class
M. S. pipe of 4.2 cms outside dia.complete with suitable M.S.
sleeve tubing of approx. 45 cms length and suitable for 76.5 mm /80
mm, Galvemizing 85 microns Per kg brackets weight or require size
pole top having suficient fastners fior fixing the brackets and having
suitable rise as per site condition as directed and spread of 1 mtr.
6 388 with suitable welded stiffner reducer and lock nut complete Hot Dip No. 614.08
Galvanized suitable for side entry fitting brackets, as per site
condition and as per drawing / directed by Engineer Incharge. - (1
No. Per St. Light Pole)-Sleeve dia 88.9mm x 3.25mm 6.5 kg/mtr
mtr length,Arm dia 42mm x 3.2mm 3.1 kg/mtr, Single arm, 1 mtr
5.9 kg, 1.5 mtr 7.4kg, 2.0 mtr 9.0 kg, Galvemizing 85 microns,
Tube, labour- galvenizing-Fastners , caps approx per bracket,
Supplying and erecting LED street light fittings with High power
White LEDs wattage of 1Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses with company mark/name engraved or
embossed 90 to 300 V,Power Factor more than 0.95, THD < 10 %,
CCT 5000 K to 5700K, Uniformity ratio >0.45, Luminaire
efficiency> 85 lumens/watt . LED driver efficiency > 85 %.
CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/
BridgeLux (U.S.A.) make LED used for luminaire. ( Each fittings
required LM-79 & LM-80 certificates)-(1 No. of (90 Watt IP 66)
Luminaire equivalent to 150 W HPSV (100 Lumens/Watt) fitting
per streetlight pole, Surge-4K) (Cat- III) as per site condition and as
per drawing/ directed by Engineer Incharge. - (1 No. Per St. Light
Supplying and erecting Flexible PVC insulated multi strand multi
core 1.1 kv grade ISI marked copper wires of following size to be
8 3878 erected as directed. (h) 2.50 Sq.mm 3 core round PVC sheathed (9 Rmt. 137.36
Mtr. per St. Light Fitting x 1 No. St. Light Fitting = 9 Mtr.)
Providing, laying, testing & commissioning of 1 x 4.0 Core x 16 Sq.
MM, XLPE (IS: 7098 (i) - 88), ISI Mark, Armoured,
Multistranded, Aluminium Conductor suitable for 1.1 kV grade to
9 11247 be laid 90 Cms under ground or to be laid on wall with necessary Rmt. 153.52
clamps or in existing cable trench/ pipe at road crossing or on floor
and making the ground as per original. - For Streetlight between two
poles & Service Connections.
Providing & laying of approved make 50 MM Nominal OD
Doubled Walled Corrugated Pipes (DWC) of polyethylene
(conforming to IS 14930 - II) with necessary connecting accessories
like coupler, Tee, L - Bow, etc. of same material at required depth
10 11247 (90 cms) including excavation for laying of cable below ground/ Rmt. 219.17
road surface for enclosing cable and back filling the same to make
ground as per original & as per instruction of Engineer Incharge -
for Streelight Cable of 1 x 4 core x 16 Sq. MM and Service cable of
1 x 4 core x 16 Sq. MM.
Providing & laying approved make Double walled corrugated pipes
(DWC) of polyethylene(conforming to IS 14930 II )with necessary
11 500 connecting accessories of same material at required depth in Rmt. 95.95
existing trench for laying of cable. below ground / road surface for
enclosing cable-(C))90 mm outer dia
SITC of Centralized Lighting Load Energy Saver System CCMS
having 15 kVA or suitable rating with a provision of CCMS
independent compartment for fixing of Three Phase Energy Meter
of concern power supply authority & 63 A MCB andsuitable for
direct switching of load upto 5 kVA per phase and having Magnetic
Amplifier Technology, -Ve Feed back, current controlled, Coil
12 8 Based, Rugged Contruction, Extra Switch gear Capacity, Micro No. 71508.00
Controller based, 7 time zones programming, Astronomical Timer
for Automatic on/off of lighting load depanding upon the weather
conditions, User friendly diagnosis, level setting as per process
need, Phase independent redundancy, CRCA Poweder coated
elegant panel, Computer interface software, THD (Harmonics)
introduced by LES System shall Nil, Lumen drop should not exceed
Providing & 1erecting
Four Polesaving
Inductive Load (C Curve) of 63 A (Cat - III) with ISI marked
having overload & short circuit triping element and breaking
capacity 10 kA conforming to IS: 8828/
Supplying & erecting FUNNEL type earthing having 60 cms x
60cms x0.315 cms 300600 mm x 600 mm x 3.15 mm thk. Copper
earth plate burried in specifically prepared earth pit 3 mtr. below
ground with 40 Kg. Charcoal and 40 Kg. salt with alternate layers of
charcoal & salt, 20 mm dia Medium Class G. I. Pipe with funnel
with a wire mesh for watering & bricks massanary block, C. I. cover
complete as per para 7.3 of IS : 3043 with necessary length of
double galvenised copper earth wire no. 6 SWG - bolted with lugs
Drilling theandroad
covered in 12 mm
& Gate dia. breaking
witout G. I. pipe -the
15 500 surface(Asphalt)for laying of cable for feeding power supply by Mtr 452.48
making up to 100 mm bore dia of hole at both end complete.
Painting the number and words for inventory Identification on
erected fittings / equipment’s or Such accessories as may required
with good quality of enamelled paint as directed by engineer in
Dismentaling the existing underground cable without damaging it
17 3500 with glands, cable and box including refelling the trench up to Mtr. 10.10
ground level and making coils complete to be placed at different
Dismentaling the existing pole above 6 mtr. Height with brackets,
clamps, insulator, stay from the cemenet concrete foundation and
making the site clear by reflling the pits with excavated materials
and bringing it to the ground level.
Transpotation of dismentaling pole and bracket by trolly & tractor
19 388 per/pole 50.50
at filter plant.
Supplying & erecting power contactor for time switch complete
erected as per direction Cat III [D] 4 pole 440V 40 Amp.
Making trench in Hard Murrum / Tar Road of suitable width of
cm or required depth for laying any size of cable or locating the
fault all over the run and back filling the same and making the
surface as normal ground. Up to 25 mm2 Cable
- Total Amount (Rs.)
- Total Amount (Rs.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender DTP.pdf
Schedule SITC B.pdf
B1 Agreement - Part 1.pdf
B1 Agreement - Part 2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .