Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | ₹17.4 L | L1 | Accepted-AOC Accept |
| 2 | L2₹19.1 L+₹1.7 L (9.99%)Rejected-AOC | ₹19.1 L+₹1.7 L (9.99%) | L2 | Rejected-AOC Reject |
| 3 | L3₹19.5 L+₹2.1 L (12.0%)Rejected-AOC | ₹19.5 L+₹2.1 L (12.0%) | L3 | Rejected-AOC Reject |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | H.N.SINGH AND COMPANY L3 | VISHAVJEET SINGH L2 | JASPREET SINGH L1 |
|---|---|---|---|---|---|---|
| 1.00 | Transportation of Rig along-with allied accessories etc.complete including erection and levelling at site through all kind of roads,approaches field etc.in all leads and lifts upto site of work complete in all respect as per the direction of the Engineer in charge. | 1 | No. | 20,000 ₹20,000 Lowest | 22,000 ₹22,000 | 20,000 ₹20,000 Lowest |
| 2.00 | Earth work in foundation for digging Tube-well in all kindes of soils including dewatering shoring strutting from ground level upto 5 metres including disposing excavated soil in all leads and lifts complete in all respect as per the direction of the Engineer in charge. | 5 | Metres | 4,000 ₹20,000 Lowest | 4,500 ₹22,500 | 6,000 ₹30,000 |
| 3.00Drilling of bore as per specifications laid down in IS-2800-1991(Part-I) with uptodate ammendments,if any;with Percussion Rig or combination drilling Rig starting with 650-600mm.dia M.S.Pipe reduced to 450-400mm.dia M.S.pipe confirming to IS-4270-2001 with uptodate ammendments,if any in all kinds of soils,boulders,rocks, collapsible strata,saturated soil, artesian conditions including the cost of all consumables,stores, water, fuel, lubricants and other accessories etc.complete in all respect as per the direction of the Engineer in charge.. | ||||||
| 3.01 | Drilling and lowering of M.S.casing pipes 650-600mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 0 to 30 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 25 | Metres | 6,000 ₹1,50,000 Lowest | 6,800 ₹1,70,000 | 6,000 ₹1,50,000 Lowest |
| 3.02 | Drilling and lowering of M.S.casing pipes 600-550mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 30 Metres to 60 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 30 | Metres | 7,000 ₹2,10,000 | 7,200 ₹2,16,000 | 6,000 ₹1,80,000 Lowest |
| 3.03 | Drilling and lowering of M.S.casing pipes 550-500mm. Dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 60 Metres to 90 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 30 | Metres | 8,000 ₹2,40,000 | 7,600 ₹2,28,000 | 7,000 ₹2,10,000 Lowest |
| 3.04 | Drilling and lowering of M.S.casing pipes 500-450mm.dia confirming to IS-4270-2001 with uptodate amme dments if any of suitable sizes as mentioned above from 90 to 125 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 35 | Metres | 9,000 ₹3,15,000 | 8,200 ₹2,87,000 | 7,000 ₹2,45,000 Lowest |
| 4.00 | Collection,preservations and display of suitable size sample box with top lid and locking arrangem,ent till handing over of the Tube-Well to the Department complete in all respect as per the direction of the Engineer in charge. | 1 | No. | 1,500 ₹1,500 | 2,500 ₹2,500 | 1,200 ₹1,200 Lowest |
| 5.00 | Supply and lowering of IS-Marked "Electric Resistance Welded Mild Blind Steel Pipe 300mm.nominal size housing, 8mm. thick having outside diametre 323.9mm.screwed and socketted confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length,welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles clamps embedded in foundation etc. including cost of all cuttings,threading and welding of pipes etc.within all leads and lifts as per the direction of the Engineer in charge. | 55 | Metres | 6,800 ₹3,74,000 | 7,000 ₹3,85,000 | 6,500 ₹3,57,500 Lowest |
| 5.01 | Supply and lowering of IS-Marked Electric Resistance Welded Mild Steel slotted pipe 300mm.dia nominal size housing, 8.00mm.thick having outside diametre 323.90mm.(BEVELLED EDGE PLANE ENDED) confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length pipe should have 1600 slots per metre as per IS-8110:1985 of 75x1.57mm.slot size, welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles clamps embedded in foundation etc.including cost of all cuttings, threading and welding of pipes etc.complete in all respect as per the direction of the Engineer in charge. | 10 | Metres | 7,800 ₹78,000 | 7,800 ₹78,000 | 7,200 ₹72,000 Lowest |
Tender Value
₹17.5 L
EMD Value
₹33,760
Closing Date
22 Jun 2026, 11:00 amClosed
Er.Anand Blouria
Jal Shakti Division Nurpur
Drilling, lowering of Assembly and development of 125 Metres Deep at Village Battu Nalla Phase-1st ).
2026_HPIPH_136531_1
EENPREA_1-1071-80 dated 12-06-2026
Open Tender
Civil Works
Item Rate
90 days
Jassur
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
₹33,760
16 Jul 2026
12 Jun 2026
22 Jun 2026
12 Jun 2026
22 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Transportation of Rig along-with allied accessories etc.complete including erection and levelling at site through all kind of roads,approaches field etc.in all leads and lifts upto site of work complete in all respect as per the direction of the Engineer in charge. | 1 | No. | - | - |
| 2 | Earth work in foundation for digging Tube-well in all kindes of soils including dewatering shoring strutting from ground level upto 5 metres including disposing excavated soil in all leads and lifts complete in all respect as per the direction of the Engineer in charge. | 5 | Metres | - | - |
| 3Drilling of bore as per specifications laid down in IS-2800-1991(Part-I) with uptodate ammendments,if any;with Percussion Rig or combination drilling Rig starting with 650-600mm.dia M.S.Pipe reduced to 450-400mm.dia M.S.pipe confirming to IS-4270-2001 with uptodate ammendments,if any in all kinds of soils,boulders,rocks, collapsible strata,saturated soil, artesian conditions including the cost of all consumables,stores, water, fuel, lubricants and other accessories etc.complete in all respect as per the direction of the Engineer in charge.. | |||||
| 3.01 | Drilling and lowering of M.S.casing pipes 650-600mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 0 to 30 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 25 | Metres | - | - |
| 3.02 | Drilling and lowering of M.S.casing pipes 600-550mm.dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 30 Metres to 60 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 30 | Metres | - | - |
| 3.03 | Drilling and lowering of M.S.casing pipes 550-500mm. Dia confirming to IS-4270-2001 with uptodate ammendments, if any of suitable sizes as mentioned above from 60 Metres to 90 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 30 | Metres | - | - |
| 3.04 | Drilling and lowering of M.S.casing pipes 500-450mm.dia confirming to IS-4270-2001 with uptodate amme dments if any of suitable sizes as mentioned above from 90 to 125 Metres below ground level within all leads and lifts as per the direction of the Engineer in charge. | 35 | Metres | - | - |
| 4 | Collection,preservations and display of suitable size sample box with top lid and locking arrangem,ent till handing over of the Tube-Well to the Department complete in all respect as per the direction of the Engineer in charge. | 1 | No. | - | - |
| 5 | Supply and lowering of IS-Marked "Electric Resistance Welded Mild Blind Steel Pipe 300mm.nominal size housing, 8mm. thick having outside diametre 323.9mm.screwed and socketted confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length,welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles clamps embedded in foundation etc. including cost of all cuttings,threading and welding of pipes etc.within all leads and lifts as per the direction of the Engineer in charge. | 55 | Metres | - | - |
| 5.01 | Supply and lowering of IS-Marked Electric Resistance Welded Mild Steel slotted pipe 300mm.dia nominal size housing, 8.00mm.thick having outside diametre 323.90mm.(BEVELLED EDGE PLANE ENDED) confirming to IS-4270-2001 with uptodate ammendments, if any, about 4.00 Metres to 7.00 Metres in length pipe should have 1600 slots per metre as per IS-8110:1985 of 75x1.57mm.slot size, welded without any circumferential joints into bore hole in vertical position including cost of all scaffolding derricks, poles clamps embedded in foundation etc.including cost of all cuttings, threading and welding of pipes etc.complete in all respect as per the direction of the Engineer in charge. | 10 | Metres | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
form06.pdf
Tender Documents • 0.62 MB
termsconditions.pdf
Tender Documents • 0.20 MB
BOQ_202061.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .