AGM P and P
ASSISTANT GENERAL MANAGER PROJECTS AND PLANNING PD ADMINISTRATION
RENOVATION OF INTERNAL ELECTRIFICATION WORKS FOR CISF CANTEEN AND BARRACKS FACT UDYOGAMANDAL 2025 26
2026_FACT_893048_1
3017/2025-2026/E32814
Open Tender
Miscellaneous Works
Item Rate
365 days
UDYOGAMANDAL
ATTACHED IN TERMS AND CONDITIONS
6 documents required · 6 mandatory
₹0
₹12,000
Yes
9 Jan 2026
9 Jan 2026
31 Jan 2026
9 Jan 2026
30 Jan 2026
9 Jan 2026
RENOVATION OF INTERNAL ELECTRIFICATION WORKS FOR CISF CANTEEN AND BARRACKS FACT UDYOGAMANDAL 2025-26.
Supply, Erection, termination and connection / servicing of Horizontal double door 4 way, Three phase 415 Volts MCB Lighting DB, having the following specifications: 1) 40 A Four pole isolator - 1 No. 2) 40 A Four pole RCCB with sensitivity of 30mA -1No. 3) 6 A single pole B type MCB- 8 Nos. 4) 16 A single pole B type MCB - 4 Nos. Any remaining module spaces should be covered by dummy plates. DB shall be mounted on suitable MS angle frame (25 x 25x 6). The frame shall be applied with one coat of epoxy primer followed by two coats of epoxy finish paint and properly fixed on wall by the contractor. The incoming and outgoing cables including earth wires in DB shall be glanded / terminated and connected using suitable cable lugs /clamps /ties. All Required structural items, DB with Four Pole Isolator/RCCB/MCBs, flexible glands, suitable pvc pipes etc, shall be in the scope of the contractor. (Including the cementing and finishing of the wall after fixing of the DB) Approved makes for DB and MCBs:- Legrand/Hager/Honeywell/Lauritz Knudsen/Schneider/abb.
Supply, Erection, termination and connection / servicing of Horizontal double door 12 way, Single phase , 230 Volts MCB Lighting DB, having the following specifications: 1) 40 A Double pole isolator - 1 No. 2) 40 A Double pole RCCB with sensitivity of 30mA -1 No. 3) 6 A single pole B type MCB- 6 Nos. Any remaining module spaces should be covered by dummy plates. DB shall be mounted on suitable MS angle frame (25 x 25x 6). The frame shall be applied with one coat of epoxy primer followed by two coats of epoxy finish paint and properly fixed on wall by the contractor. The incoming and outgoing cables including earth wires in DB shall be glanded / terminated and connected using suitable cable lugs /clamps /ties. All Required structural items, DB with DP isolator/ RCCB/MCBs, flexible glands, suitable pvc pipes etc, shall be in the scope of the contractor. (Including the cementing and finishing of the wall after fixing of the DB) Approved makes for DB and MCBs:- Legrand / Hager / Honeywell / Abb /Lauritz Knudsen/Schneider/.
Open pipe Point wiring with individual control For 16 A power sockets and 16 A DP switch for ACs, using Flexible copper cables 2.5 sqmm for control and neutral connection through pvc conduits not less than 20 mm using metal saddles with spacing not exceed 50 cm as per relevant drawings or instructions from FACT Engineer in Charge. The work shall include wiring along roof / beam / column / ceiling using clamps and drawing wires as required. Preparation and fixing of modular switch boards, switches, cover plates, dummy plates, Etc drawing of 1.5 sq mm earth wires of flexible copper wire of green color for body earthing of metal clad items, connecting, testing and commissioning. For wire length greater than 10 m shall be considered as one and half point. All the materials for this Work shall be in the Scope of the contractor. If additional power sockets are required in same Switch Boards that shall be considered as half point. Pipe shall be of medium ISI marked. Approved Make : Wire : Polycab/ RR Kabel/ Kei / Finolex of FR/FR-LSHS Type Switch ,Sockets, Regulators etc : Legrand-Myrius/ Honeywell-Horizon /Schneider-Unica Pure/ L&T- Entice.
Supply and installation of BLDC ceiling fans (1200mm) regulator type. Supply of all materials required for the work shall under the scope of the contractor. The specifications of the ceiling fan is such that its service value should be higher than 5.5 CMM/Watts. (Refer BEE Guide Line For service value and Star Ratings). Approved Make :- Luker /Crompton / Usha / Orient.
Supply, fabrication and installation of extensible downrod for ceiling fan of length 700 mm and dia of inner 12 mm using suitable MS pipe of gauge 14. The downrod shall be painted with the same colour as that of supplied ceiling fan.
Supply and Installation of of 20 W LED tube fittings with required clamps/fastners. All materials such as LED Fittings, clamps and fastners, etc. required for this work are in the scope of the contractor.Light output shall be white in colour. Approved Make : Luker /Havells /Philips/Syska.
Erection of earth electrodes, earth cable laying 2 runs of 1 x 16 sq.mm Aluminium PVC cable, from earthing pit to corresponding 3 phase/ single phase DB, clamping, connection and commissioning of maintenance free copper bonded earthing systems of DB-at suitable locations.Installation of earthing system as per the specified condition mentioned above and supply of all required materials for this work such as maintenance free copper bonded earthing system approved by Kerala State Electrical Inspectorate, comprising of 3 m long, dia not less than 17 mm earth electrode of low carbon steel with 250 micron copper bonding on outer surface with associated items like environment friendly carbon based back fill compound, hardware, clamps, binding wires, connection lugs, anticorrosive paint, bituman, Sand, cement, Bricks and required length of 1 x 16 sq.mm flexible Al PVC cable etc as required for this work shall be in the scope of the contractor.
Supply of 6A Modular Switches as spares for the work specified in Schedule No-3. (Brand and type of switches should be exactly same as the switches used for the work specified in Schedule No -3)
Supply of 6A Modular Sockets as spares for the work specified in Schedule No- 3. (Brand and type of sockets should be exactly same as the sockets used for the work specified in Schedule No -3)
Supply of Modular step type regulators as spares for the work specified in Schedule No-3. (Brand and type of Regulators should be exactly same as the Regulators used for the work specified in Schedule No -3)
Supply and installation of Angle Batten Holders for Rooms , Bathrooms. All material required for the work including the Angle Batten Shall be supplied by the Contractor.
Supply of 16A Modular Switches as spares for the work specified in Schedule No -4. (Brand and type of switches should be exactly same as the switches used for the work specified in Schedule No -4)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
comp32814.pdf
Additional Documents • 0.29 MB
STC32814.pdf
Tender Documents • 13.61 MB
BOQ_938669.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .